In this study, we analyze factors affecting the explosion limits of flammable refrigerants. We conclude that any method used for measuring flammable refrigerant explosion limits has its conditional restrictions. Flamm...In this study, we analyze factors affecting the explosion limits of flammable refrigerants. We conclude that any method used for measuring flammable refrigerant explosion limits has its conditional restrictions. Flammable refrigerants in the atmosphere can also explode under certain conditions, when the concentration is approaching the explosion limits. An experimental study on the explosion limits of six kinds of flammable refrigerants is carried out with a mixture of refrigerant and combustible refrigerant, which has a similar effect to a flame retardant. An experimental apparatus was designed to test the explosion limits of mixtures made from three different nonflammable refrigerants and six different flammable refrigerants. Two practical models were developed to estimate the critical concentration for inhibiting explosion of refrigerant mixtures: one was made up of two flammable components with one nonflammable component, and the second was made up of one flammable component with two nonflammable components.展开更多
Due to its flammable,explosive,and corrosive characteristics,fire,and explosion accidents caused by ammonia leakage occur from time to time.In this work,the concentration distribution of the model was calculated accor...Due to its flammable,explosive,and corrosive characteristics,fire,and explosion accidents caused by ammonia leakage occur from time to time.In this work,the concentration distribution of the model was calculated according to the existing formula of probabilistic risk assessment.Using the revised formulas,the leakage of the ammonia room was quantitatively analyzed,and different state parameters were analyzed to find out the dangerous leakage points of the ammonia refrigeration system.The results of the calculation are that the existence of obstacles in the space will increase the probability of leakage risk.And the greater the leakage time to the lower flammability limit accounts for the total leakage time,the greater the risk probability.Dangerous leakage in ammonia systems mainly occurs in storage tanks and condensers.The data show that the dynamic mass flow of ammonia leakage decreases with time,and the leakage diameter increases with the increase of leakage pressure.At the same time,the leakage mass increases gradually with the leakage aperture near circular.展开更多
文摘In this study, we analyze factors affecting the explosion limits of flammable refrigerants. We conclude that any method used for measuring flammable refrigerant explosion limits has its conditional restrictions. Flammable refrigerants in the atmosphere can also explode under certain conditions, when the concentration is approaching the explosion limits. An experimental study on the explosion limits of six kinds of flammable refrigerants is carried out with a mixture of refrigerant and combustible refrigerant, which has a similar effect to a flame retardant. An experimental apparatus was designed to test the explosion limits of mixtures made from three different nonflammable refrigerants and six different flammable refrigerants. Two practical models were developed to estimate the critical concentration for inhibiting explosion of refrigerant mixtures: one was made up of two flammable components with one nonflammable component, and the second was made up of one flammable component with two nonflammable components.
基金supported by the State Key Program of the National Natural Science Foundation of China(Grant No.51936007)。
文摘Due to its flammable,explosive,and corrosive characteristics,fire,and explosion accidents caused by ammonia leakage occur from time to time.In this work,the concentration distribution of the model was calculated according to the existing formula of probabilistic risk assessment.Using the revised formulas,the leakage of the ammonia room was quantitatively analyzed,and different state parameters were analyzed to find out the dangerous leakage points of the ammonia refrigeration system.The results of the calculation are that the existence of obstacles in the space will increase the probability of leakage risk.And the greater the leakage time to the lower flammability limit accounts for the total leakage time,the greater the risk probability.Dangerous leakage in ammonia systems mainly occurs in storage tanks and condensers.The data show that the dynamic mass flow of ammonia leakage decreases with time,and the leakage diameter increases with the increase of leakage pressure.At the same time,the leakage mass increases gradually with the leakage aperture near circular.