期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Efficacy of spray flushing in the reprocessing of flexible endoscopes:A randomized controlled trial
1
作者 Jiang Du Miao Zhang +5 位作者 Si-Yuan Tao Lian-Song Ye Hui Gong Bing Hu Qiong-Ying Zhang Fu Qiao 《World Journal of Gastroenterology》 SCIE CAS 2024年第31期3680-3688,共9页
BACKGROUND Commonly used cleaning brushes in the reprocessing of flexible endoscopes often cause damage within the working channels.AIM To develop a spray flushing system to achieving effective cleaning of the working... BACKGROUND Commonly used cleaning brushes in the reprocessing of flexible endoscopes often cause damage within the working channels.AIM To develop a spray flushing system to achieving effective cleaning of the working channels while minimizing damage.METHODS This prospective study included 60 used endoscopes and 60 Teflon tubes randomly divided into a control group(n=30)and an experimental group(n=30).The material of Teflon tubes was the same as that of the endoscope working channel.Endoscopes in the control group were manually cleaned using traditional cleaning brushes,while those in the experimental group were cleaned using the newly developed spray flushing system.ATP levels,cleanliness,and microbiological testing of the working channels were measured.Additionally,Teflon tubes in the control group underwent 500 passes with a cleaning brush,while those in the experimental group were subjected to the spray flushing system,and channel damage was evaluated.RESULTS The ATP levels(RLU)in the two groups were 32.5(13-66)and 26(16-40),respectively(P>0.05).Cleanliness scores were 1.5(1-2)and 1(1-2),respectively(P>0.05).Debris was found in 73.3%of the control group,which was significantly higher than 46.7%in the experimental group(P<0.05).Microbiological tests for both groups yielded negative results.Teflon tube damage in the control group was rated at 4(4-5.25),which was significantly higher than in the experimental group 4(3-4)(P<0.01).CONCLUSION The spray flushing system demonstrated superior efficacy in removing debris and resulted in less damage to the endoscope working channels compared with traditional cleaning brushes. 展开更多
关键词 endoscope ATP flexible endoscope DISINFECTION REPROCESSING
下载PDF
Snare-assisted flexible endoscope in trans-gastric endoscopic gallbladder-preserving surgery:A pilot animal study 被引量:1
2
作者 Xian-Wen Guo Yun-Xiao Liang +3 位作者 Peng-Yu Huang Lie-Xin Liang Yi-Qing Zeng Zhen Ding 《World Journal of Gastroenterology》 SCIE CAS 2022年第19期2112-2122,共11页
BACKGROUND Natural orifice transluminal endoscopic surgery(NOTES)gallbladder-preserving surgery by flexible endoscopy is an emerging technology.However,the gallbladder fails to obtain traction and positioning function... BACKGROUND Natural orifice transluminal endoscopic surgery(NOTES)gallbladder-preserving surgery by flexible endoscopy is an emerging technology.However,the gallbladder fails to obtain traction and positioning functions during the operation.AIM To evaluate the feasibility and safety of a new surgical method,“snare-assisted pure NOTES gallbladder-preserving surgery”.METHODS Eight miniature pigs were randomly divided into the experimental group[NOTES gallbladder-preserving surgery using the snare device,snare assisted(SA)]and the control group(NOTES gallbladder-preserving surgery without using the snare device,NC),with four cases in each group.The differences between the two groups of animals in operating time,operating workload,complications,adverse events,white blood cells,and liver function were determined.RESULTS No differences were found in the surgical success rate,gallbladder incision closure,white blood cell count,or liver function between the two groups.The total operating time,gallbladder incision blood loss,gallbladder disorientation time,gallbladder incision closure time,and workload scores on the National Aeronautics and Space Administration-Task Load Index were significantly reduced in the SA group(P<0.05).CONCLUSION These results indicated that snare-assisted pure NOTES gallbladder-preservation surgery using standard endoscopic instruments reduced the difficulty of operation,shortened operation time,and did not increase complications in pigs.A new method for pure NOTES gallbladder-preservation surgery was provided. 展开更多
关键词 SNARE flexible endoscope Endoscopic gallbladder-preserving surgery Natural orifice transluminal endoscopic surgery Transgastric Minimally invasive
下载PDF
A novel flexible endoscope-based transumbilical fenestration of liver cyst 被引量:4
3
作者 CAI Xiu-jun DAI Yi WANG Jian-guo YU Hong LIANG Xiao ZHENG Xue-yong WANG Yi-fan 《Chinese Medical Journal》 SCIE CAS CSCD 2008年第23期2461-2462,共2页
Laparoscopic procedure as a minimally invasive surgery had been introduced into many abdominal surgery. Smaller incisions of the abdominal wall reduce postoperative pain and the risk of wound complications, and provid... Laparoscopic procedure as a minimally invasive surgery had been introduced into many abdominal surgery. Smaller incisions of the abdominal wall reduce postoperative pain and the risk of wound complications, and provide an excellent cosmetic result compared with open surgery. Flexible endoscope-based transgastric, transcolonic, or transvaginal surgery for abdominal exploration, cholecystectomy, appendectomy, and tubal ligation may further reduce the surgical invasion. 展开更多
关键词 liver cyst FENESTRATION flexible endoscope transumbilical
原文传递
New flexible endoscopic controlled stapler technique for the treatment of Zenker's diverticulum:A case series 被引量:2
4
作者 Johanna Wilmsen Robert Baumbach +7 位作者 Dietmar Stüker Vincens Weingart Frank Neser Stefan Karl Golder Christof Pfundstein Ellen Claudia Notzel Thomas Rosch Siegbert Faiss 《World Journal of Gastroenterology》 SCIE CAS 2017年第17期3084-3091,共8页
AIMTo report about the combination and advantages of a stapler-assisted diverticulotomy performed by flexible endoscopy.METHODSFrom November 2014 till December 2015 17 patients (8 female, 9 male, average age 69.8 year... AIMTo report about the combination and advantages of a stapler-assisted diverticulotomy performed by flexible endoscopy.METHODSFrom November 2014 till December 2015 17 patients (8 female, 9 male, average age 69.8 years) with a symptomatic Zenker diverticulum (mean size 3.5 cm) were treated by inserting a new 5 mm fully rotatable surgical stapler (MicroCutter30 Xchange, Cardica Inc.) next to an ultrathin flexible endoscope through an overtube. The Patients were under conscious sedation with the head reclined in left position, the stapler placed centrally and pushed forward to the bottom of the diverticulum. The septum was divided by the staple rows under flexible endoscopic control.RESULTSIn eleven patients (64.7%) the stapler successfully divided the septum completely. Mean procedure time was 21 min, medium size of the septum was 2.8 cm (range 1.5 cm to 4 cm). In four patients the septum was shorter than 3 cm, in seven longer than 3 cm. To divide the septum, averagely 1.3 stapler cartridges were used. Two minor bleedings occurred. Major adverse events like perforation or secondary haemorrhage did not occur. After an average time of two days patients were discharged from the hospital. In 6 patients (35.3%) the stapler failed due to a thick septum or insufficient reclination of the head. Follow up endoscopy was performed after an average of two months in 9 patients; 4 patients (44.4%) were free of symptoms, 5 patients (55.6%) stated an improvement. A relapse of symptoms did not occur.CONCLUSIONFlexible endoscopic Zenker diverticulotomy by using a surgical stapler is a new, safe and efficient treatment modality. A simultaneously tissue opening and occlusion prevents major complications. 展开更多
关键词 Zenker’s diverticulum flexible endoscopic treatment Stapler technique Overtube Surgical stapler
下载PDF
Flexible robotic endoscopy for treating gastrointestinal neoplasms 被引量:1
5
作者 Keiichiro Kume 《World Journal of Gastrointestinal Endoscopy》 2023年第6期434-439,共6页
Therapeutic flexible endoscopic robotic systems have been developed primarily as a platform for endoscopic submucosal dissection(ESD)in the treatment of earlystage gastrointestinal cancer.Since ESD can only be perform... Therapeutic flexible endoscopic robotic systems have been developed primarily as a platform for endoscopic submucosal dissection(ESD)in the treatment of earlystage gastrointestinal cancer.Since ESD can only be performed by highly skilled endoscopists,the goal is to lower the technical hurdles to ESD by introducing a robot.In some cases,such robots have already been used clinically,but they are still in the research and development stage.This paper outlined the current status of development,including a system by the author’s group,and discussed future challenges. 展开更多
关键词 Therapeutic flexible endoscopic robotic systems Endoscopic submucosal dissection Tissue triangulation
下载PDF
Individual flexible endoscopic procedure for treatment of obstruction of fourth ventricle outlet
6
作者 肖庆 《外科研究与新技术》 2011年第3期223-224,共2页
Objective To summarize the indication,method and effect of individual flexible endoscopic procedure for treatment of obstruction of fourth ventricle outlet. Methods The clinical data of 32 cases of obstruction of four... Objective To summarize the indication,method and effect of individual flexible endoscopic procedure for treatment of obstruction of fourth ventricle outlet. Methods The clinical data of 32 cases of obstruction of fourth ventricle outlet treated by individual flexible endoscopic 展开更多
关键词 flexible Individual flexible endoscopic procedure for treatment of obstruction of fourth ventricle outlet
下载PDF
Embryonic natural orifice transluminal endoscopic surgery in the treatment of severe acute pancreatitis complicated by abdominal compartment syndrome 被引量:15
7
作者 Hui-ming Zhu Shao-qing Guo +2 位作者 Xiu-min Liao Li Zhang Li Cai 《World Journal of Emergency Medicine》 CAS 2015年第1期23-28,共6页
BACKGROUND: The study aimed to estimate the value of embryonal natural orifice transluminal endoscopic surgery(ENOTES) in treating severe acute pancreatitis(SAP) complicated with abdominal compartment syndrome(ACS).ME... BACKGROUND: The study aimed to estimate the value of embryonal natural orifice transluminal endoscopic surgery(ENOTES) in treating severe acute pancreatitis(SAP) complicated with abdominal compartment syndrome(ACS).METHODS: The patients, who were randomized into an ENOTES group and an operative group, underwent ENOTES and laparotomy, respectively. The results and complications of the two groups were compared.RESULTS: Enterocinesia was observed earlier in the ENOTES group than in the operative group. Acute Physiology and Chronic Health Evaluation II(APACHE II) score of patients in the ENOTES group was lower than that of the operative group on the 1st, 3rd and 5th post-operative day(P<0.05). The cure rate was 96.87% in the ENOTES group, which was statistically different from 78.12% in the operative group(P<0.05). There were significant differences in complications and mortality between the two groups(P<0.01).CONCLUSION: Compared with surgical decompression, ENOTES associated with flexible endoscope therapy is an effective and minimal invasive procedure with less complications. 展开更多
关键词 Embryonal natural orifi ce transluminal endoscopic surgery flexible endoscope Peritoneal lavage Peritoneal dialysis Severe acute pancreatitis Abdominal compartment syndrome
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部