期刊文献+
共找到105篇文章
< 1 2 6 >
每页显示 20 50 100
Fluctuation pressure on a bio-membrane confined within a parabolic potential well 被引量:2
1
作者 L. B. Freund 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2012年第4期1180-1185,共6页
A compliant bio-membrane with a nominally fiat reference configuration is prone to random transverse deflections when placed in water, due primarily to the Brownian motion of the water molecules. On the average, these... A compliant bio-membrane with a nominally fiat reference configuration is prone to random transverse deflections when placed in water, due primarily to the Brownian motion of the water molecules. On the average, these fluctuations result in a state of thermodynamic equilibrium between the entropic energy of the water and the total free en- ergy of the membrane. When the membrane is in close proximity to a parallel surface, that surface restricts the fluctuations of the membrane which, in turn, results in an increase in its free energy. The amount of that increase depends on the degree of confinement, and the resulting gradient in free energy with degree of confinement implies the existence of a confining pressure. In the present study, we assume that the confinement is in the form of a continuous parabolic po- tential well resisting fluctuation. Analysis leads to a closed form expression for the mean pressure resulting from this confinement, and the results are discussed within the broader context of results in this area. In particular, the results provide insights into the roles of membrane stiffness, number of degrees of freedom in the model of the membrane and other system parameters. 展开更多
关键词 Statistical mechanics Membrane fluctuations Parabolic confinement. Confining pressure
下载PDF
Spectrum of turbulent-boundary-layer fluctuation pressure and response of a polyvinylidence fluoride hydrophone
2
作者 GE Huiliang (State Key Lab. of Oceanic Acoustics, Ha-on Applied Acoustic Institute Hanggzhou 310012) HE Zuoyong (Harbin Engineering University Harbin 150001) BAO Xuemei (State Keg Lab. of Oceanic Acoustics, Hangzhou Applied Acoustic Institute Hanggzhou 31 《Chinese Journal of Acoustics》 2001年第2期144-155,共12页
The point power spectrum density and the wavenumber frequency spectrum density of turbulent - boundary- layer fluctuation pressure were measured in water-tunnel by use of a 8 mm hydrophone and a 20-element array, resp... The point power spectrum density and the wavenumber frequency spectrum density of turbulent - boundary- layer fluctuation pressure were measured in water-tunnel by use of a 8 mm hydrophone and a 20-element array, respectively. The non-dimensional representation of measured point power spectrum coincides with the measured results by Bull M. K. et. al. in wind tunnel. The convection peak can be seen clearly in the measured wavenumber frequency spectrum and the convection velocity can be calculated from the location of the convection peak. The response spectrum of a polyvinylidence fluoride (PVDF) hydrophone, which receiving area is 100 mm× 60 nun, was also measured. By comparing it with the response spectrtum of the 8 mm hydrophone, it is shown that the PVDF hyrdophone has a strong wavenumber filtering effect on turbulent - boundary-layer pressure fluctuation. 展开更多
关键词 TBL Spectrum of turbulent-boundary-layer fluctuation pressure and response of a polyvinylidence fluoride hydrophone
原文传递
Unsteady Turbulent Simulation and Pressure Fluctuation Analysis for Centrifugal Pumps 被引量:49
3
作者 YUAN Shouqi NI Yongyan PAN Zhongyong YUAN Jianping 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2009年第1期64-69,共6页
The pressure fluctuation in the flow passage of both impeller and casing is addressed on design condition. The initial conditions for the unsteady turbulent simulation are resulted from the steady calculations, and th... The pressure fluctuation in the flow passage of both impeller and casing is addressed on design condition. The initial conditions for the unsteady turbulent simulation are resulted from the steady calculations, and the three dimensional unsteady turbulent simulation concerning the rotor-stator interaction is executed by a Navier-Stoke solver embedded with k -ε turbulence model and with appropriate moving interface boundary conditions. Detecting points are distributed in the flow passage in different radial and circumferential positions to capture the static pressure fluctuation character for one cycle of the impeller. The time-domain spectrums show that the static pressure curves are periodic and have five peaks and five valleys. With the radius increasing, the pressure fluctuation peak-to-peak values in the impeller are increasing, and reach the maximum value on the interface. In the casing flow passage, those values are about 7% of local static pressure except some ones near the tongue. The values become decreasingly in the diffuser pipe. The frequency spectrums transformed by fast Fourier transform (FFT) show that the dominant frequency is approximate with the blade passing frequency, and the pressure fluctuations in impeller passage have high frequency content while those in casing ones have no such information. 展开更多
关键词 centrifugal pump rotor-stator interaction unsteady turbulent flow pressure fluctuation
下载PDF
Experimental Study of the Pressure Fluctuations in a Pump Turbine at Large Partial Flow Conditions 被引量:33
4
作者 RAN Hongjuan LUO Xianwu +3 位作者 ZHU Lei ZHANG Yao WANG Xin XU Hongyuan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第6期1205-1209,共5页
Frequent shifts of output and operating mode require a pump turbine with excellent stability. Current researches show that large partial flow conditions in pump mode experience positive-slope phenomena with a large he... Frequent shifts of output and operating mode require a pump turbine with excellent stability. Current researches show that large partial flow conditions in pump mode experience positive-slope phenomena with a large head drop. The pressure fluctuation at the positive slope is crucial to the pump turbine unit safety. The operating instabilities at large partial flow conditions for a pump turbine are analyzed. The hydraulic performance of a model pump turbine is tested with the pressure fluctuations measured at unstable operating points near a positive slope in the performance curve. The hydraulic performance tests show that there are two separated positive-slope regions for the pump turbine, with the flow discharge for the first positive slope from 0.85 to 0.91 times that at the maximum efficiency point. The amplitudes of the pressure fluctuations at these unstable large partial flow conditions near the first positive slope are much larger than those at stable operating condtions. A dominant frequency is measured at 0.2 times the impeller rotational frequency in the flow passage near the impeller exit, which is believed to be induced by the rotating stall in the flow passage of the wicket gates. The test results also show hysteresis with pressure fluctuations when the pump turbine is operated near the first positive slope. The hysteresis creates different pressure fluctuations for those operation points even though their flow rates and heads are similar respectively. The pressure fluctuation characteristics at large partial flow conditions obtained by the present study will be helpful for the safe operation of pumped storage units. 展开更多
关键词 positive slope pressure fluctuation rotating stall pump turbine
下载PDF
Numerical Simulation of Pressure Fluctuations in a Large Francis Turbine Runner 被引量:9
5
作者 WANG Fujun LIAO Cuilin TANG Xuelin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第6期1198-1204,共7页
The pressure fluctuation caused by unsteady flow in runner is one of the main reasons of vibration for a large Francis hydraulic turbine. It directly affects the steady operation of the hydraulic turbine unit. The exi... The pressure fluctuation caused by unsteady flow in runner is one of the main reasons of vibration for a large Francis hydraulic turbine. It directly affects the steady operation of the hydraulic turbine unit. The existing research of the pressure fluctuation in hydraulic turbine mainly focuses on the unsteady flow in draft tube. Accurate distribution of pressure fluctuations inside a runner is not very clear. In this paper, the numerical method for predicting the pressure fluctuations in runner is investigated and the numerical simulation is performed for a large Francis hydraulic turbine. It is proved that the combination of shear-stress transport(SST) k-o) turbulence model and pressure-implicit with splitting of operators(PISO) algorithm could give more reliable prediction of pressure fluctuations in runner. The frequencies of pressure fluctuations in runner are affected by the flow in guide vane and the flow in draft tube The first dominant frequency is significantly determined by the flow in draft tube, especially at part load condition. This frequency is approximately equal to one-third of the runner rotating frequency. The evident second dominant frequency is exactly equal to the guide vane passing frequency. The peak-to-peak amplitudes of pressure fluctuations in runner at small guide vane open angle are larger than that at large open angle at the same operating head. The amplitudes at points on blade pressure surface are generally greater than that on suction surface. The research results could be used to direct the hydraulic design and operation stability improvement of a large Francis hydraulic turbine. 展开更多
关键词 hydraulic turbine RUNNER pressure fluctuation numerical simulation
下载PDF
Impact of Impeller Stagger Angles on Pressure Fluctuation for a Double-Suction Centrifugal Pump 被引量:8
6
作者 Da-Chun Fu Fu-Jun Wang +2 位作者 Pei-Jian Zhou Ruo-Fu Xiao Zhi-Feng Yao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第1期198-211,共14页
Pressure fluctuation may cause high amplitude of vibration of double-suction centrifugal pumps, but the impact of impeller stagger angles is still not well understood. In this paper, pressure fluctuation experiments a... Pressure fluctuation may cause high amplitude of vibration of double-suction centrifugal pumps, but the impact of impeller stagger angles is still not well understood. In this paper, pressure fluctuation experiments are carried out for five impeller configurations with different stagger angles by using the same test rig system. Results show that the stagger angles exert negligible effects on the characteristics of head and efficiency. The distributions of pressure fluctuations are relatively uniform along the suction chamber wall, and the maximum pressure fluctuation amplitude is reached near the suction inlet tongue region. The pressure fluctuation characteristics are affected largely by impeller rotation, whose dominant frequencies include impeller rotation frequency and its harmonic frequencies, and half blade passage frequency. The stagger angle exerts a small effect on the pressure fluctuations in the suction chamber while a great effect on the pressure fluctuation in volute casing, especially on the aspect of decreasing the amplitude on blade passage frequency. Among the tested cases, the distribution of pressure fluctuations in the volute becomes more uniform than the other impeller configurations and the level of pressure fluctuation may be reduced by up to 50% when the impeller stagger angle is close to 24° or 360°.The impeller structure pattern needs to be taken into consideration during the design period, and the halfway staggered impeller is strongly recommended. 展开更多
关键词 Double-suction centrifugal pump Impeller stagger angle pressure fluctuation Frequency spectra analysis
下载PDF
CFD simulation of pressure fluctuation characteristics in the gas-solid fluidized bed:Comparisons with experiments 被引量:3
7
作者 Wang Qingcheng Zhang Kai Gu Hongyan 《Petroleum Science》 SCIE CAS CSCD 2011年第2期211-218,共8页
A simple hydrodynamic model based on two-fluid theory, taking into account the effect of discrete particles on both the gas- and solid-phase momentum equations, was used to numerically investigate the pressure fluctua... A simple hydrodynamic model based on two-fluid theory, taking into account the effect of discrete particles on both the gas- and solid-phase momentum equations, was used to numerically investigate the pressure fluctuation characteristics in a gas-solid fluidized bed with the aid of CFX 4.4, a commercial CFD software package, by adding user-defined Fortran subroutines. Numerical simulations together with typical experimental measurements show that pressure fluctuations originate above the distributor when a gas pulse is injected into the fluidized bed. The pressure above the bubble gradually increases due to the presence of a rising bubble. When the bubble passes through the bed surface, the pressure near the bed surface gradually decreases to a lower value. Moreover, the pressure signals in the bubbling fluidized beds show obviously periodic characteristics. The major frequency of pressure fluctuations at the same vertical position is affected slightly by the operating gas velocity, and the amplitude of pressure fluctuations is related to both the operating gas velocity and the vertical height. In this study, the influence of the operating gas velocity on the pressure wave propagation velocity can be ignored, and only two peak frequencies in the power spectrum of the pressure fluctuations are observed which are associated with the bubble formation above the distributor and its eruption at the bed surface. 展开更多
关键词 Gas-solid fluidized bed CFD simulation experimental measurements propagation ofpressure fluctuations pressure wave velocity pressure fluctuation frequency
下载PDF
Influence of the Axial Position of the Guide Vane on the Fluctuations of Pressure in a Nuclear Pump 被引量:4
8
作者 Xiaorui Cheng Yimeng Jiang +1 位作者 Min Li Shuyan Zhang 《Fluid Dynamics & Materials Processing》 EI 2020年第5期1047-1061,共15页
The influence of the axial mount position of the guide vane on the pressure fluctuation in a nuclear pump(AP1000)is investigated.The characteristics of the three-dimensional flow inside the nuclear pump are analyzed b... The influence of the axial mount position of the guide vane on the pressure fluctuation in a nuclear pump(AP1000)is investigated.The characteristics of the three-dimensional flow inside the nuclear pump are analyzed by means of numerical simulation.Results indicate that when the axial relative distance between the guide vane and the pumping chamber is reduced,in conditions of“small flow,”the efficiency of the pump increases,the pressure inside the pumping chamber decreases,while the losses related to the guide vane grow.Under large flow conditions,as the efficiency of the pump decreases,the losses for the guide vane and the pumping chamber increase.The pressure fluctuation in the annular pumping chamber is basically determined by the rotation frequency and the blade passing frequency.The magnitude of these fluctuations is affected by the guide vane axial position.In particular,the smallest possible amplitude is obtained when the outlet central plane of the guide vane coincides with the outlet axis of the pumping chamber. 展开更多
关键词 Nuclear main pump guide vane axial position pressure fluctuation
下载PDF
Pressure fluctuation signal analysis of pump based on ensemble empirical mode decomposition method 被引量:3
9
作者 Hong PAN Min-sheng BU 《Water Science and Engineering》 EI CAS CSCD 2014年第2期227-235,共9页
Pressure fluctuations, which are inevitable in the operation of pumps, have a strong non-stationary characteristic and contain a great deal of important information representing the operation conditions. With an axial... Pressure fluctuations, which are inevitable in the operation of pumps, have a strong non-stationary characteristic and contain a great deal of important information representing the operation conditions. With an axial-flow pump as an example, a new method for time-frequency analysis based on the ensemble empirical mode decomposition (EEMD) method is proposed for research on the characteristics of pressure fluctuations. First, the pressure fluctuation signals are preprocessed with the empirical mode decomposition (EMD) method, and intrinsic mode functions (IMFs) are extracted. Second, the EEMD method is used to extract more precise decomposition results, and the number of iterations is determined according to the number of IMFs produced by the EMD method. Third, correlation coefficients between IMFs produced by the EMD and EEMD methods and the original signal are calculated, and the most sensitive IMFs are chosen to analyze the frequency spectrum. Finally, the operation conditions of the pump are identified with the frequency features. The results show that, compared with the EMD method, the EEMD method can improve the time-frequency resolution and extract main vibration components from pressure fluctuation signals. 展开更多
关键词 pressure fluctuation ensemble empirical mode decomposition intrinsic modefunction correlation coefficient
下载PDF
Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump 被引量:2
10
作者 Qianqian Li Shiyang Li +2 位作者 Peng Wu Bin Huang Dazhuan Wu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2021年第1期181-198,共18页
Double-suction centrifugal pumps have been applied extensively in many areas,and the significance of pressure fluctuations inside these pumps with large power is becoming increasingly important.In this study,a double-... Double-suction centrifugal pumps have been applied extensively in many areas,and the significance of pressure fluctuations inside these pumps with large power is becoming increasingly important.In this study,a double-suction centrifugal pump with a high-demand for vibration and noise was redesigned by increasing the flow uniformity at the impeller discharge,implemented by combinations of more than two parameters.First,increasing the number of the impeller blades was intended to enhance the bounding effect that the blades imposed on the fluid.Subsequently,increasing the radial gap between the impeller and volute was applied to reduce the rotor-stator interaction.Finally,the staggered arrangement was optimized to weaken the efficacy of the interference superposition.Based on numerical simulation,the steady and unsteady characteristics of the pump models were calculated.From the fluctuation analysis in the frequency domain,the dimensionless pressure fluctuation amplitude at the blade passing frequency and its harmonics,located on the monitoring points in the redesigned pumps(both with larger radial gap),are reduced a lot.Further,in the volute of the model with new impellers staggered at 12°,the average value for the dimensionless pressure fluctuation amplitude decreases to 6%of that in prototype pump.The dimensionless rootmean-square pressure contour on the mid-span of the impeller tends to be more uniform in the redesigned models(both with larger radial gap);similarly,the pressure contour on the mid-section of the volute presents good uniformity in these models,which in turn demonstrating a reduction in the pressure fluctuation intensity.The results reveal the mechanism of pressure fluctuation reduction in a double-suction centrifugal pump,and the results of this study could provide a reference for pressure fluctuation reduction and vibration performance reinforcement of doublesuction centrifugal pumps and other pumps. 展开更多
关键词 Double-suction centrifugal pump pressure fluctuation Flow uniformity Numerical simulation
下载PDF
Elimination of Fuel Pressure Fluctuation and Multi-injection Fuel Mass Deviation of High Pressure Common-rail Fuel Injection System 被引量:8
11
作者 LI Pimao ZHANG Youtong +1 位作者 LI Tieshuan XIE Lizhe 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第2期294-306,共13页
The influence of fuel pressure fluctuation on multi-injection fuel mass deviation has been studied a lot,but the fuel pressure fluctuation at injector inlet is still not eliminated efficiently.In this paper,a new type... The influence of fuel pressure fluctuation on multi-injection fuel mass deviation has been studied a lot,but the fuel pressure fluctuation at injector inlet is still not eliminated efficiently.In this paper,a new type of hydraulic filter consisting of a damping hole and a chamber is developed for elimination of fuel pressure fluctuation and multi-injection fuel mass deviation.Linear model of the improved high pressure common-rail system(HPCRS)including injector,the pipe connecting common-rail with injector and the hydraulic filter is built.Fuel pressure fluctuation at injector inlet,on which frequency domain analysis is conducted through fast Fourier transformation,is acquired at different target pressure and different damping hole diameter experimentally.The linear model is validated and can predict the natural frequencies of the system.Influence of damping hole diameter on fuel pressure fluctuation is analyzed qualitatively based on the linear model,and it can be inferred that an optimal diameter of the damping hole for elimination of fuel pressure fluctuation exists.Fuel pressure fluctuation and fuel mass deviation under different damping hole diameters are measured experimentally,and it is testified that the amplitude of both fuel pressure fluctuation and fuel mass deviation decreases first and then increases with the increasing of damping hole diameter.The amplitude of main injection fuel mass deviation can be reduced by 73%at most under pilot-main injection mode,and the amplitude of post injection fuel mass deviation can be reduced by 92%at most under main-post injection mode.Fuel mass of a single injection increases with the increasing of the damping hole diameter.The hydraulic filter proposed by this research can be potentially used to eliminate fuel pressure fluctuation at injector inlet and improve the stability of HPCRS fuel injection. 展开更多
关键词 high pressure common-rail system pressure fluctuation multi-injection fuel mass deviation hydraulic filter
下载PDF
Time-series analysis of the characteristic pressure fluctuations in a conical fluidized bed with negative pressure 被引量:1
12
作者 Sheng Fang Yanding Wei +2 位作者 Lei Fu Geng Tian Haibin Qu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第4期87-99,共13页
The negative pressure conical fluidized bed is widely used in the pharmaceutical industry.In this study,experiments based on the negative pressure conical fluidized bed are carried out by changing the material mass an... The negative pressure conical fluidized bed is widely used in the pharmaceutical industry.In this study,experiments based on the negative pressure conical fluidized bed are carried out by changing the material mass and particle size.The pressure fluctuation signals are analyzed by the time and the frequency domain methods.A method for absolutely characterizing the degree of the energy concentration at the main frequency is proposed,where the calculation is to divide the original power spectrum by the average signal power.A phenomenon where the gas velocity curve temporarily stops growing is observed when the material mass is light,and the particle size is small.The standard deviation and kurtosis both rapidly change at the minimum fluidization velocity and thus can be used to determine the flow regime,and the variation rule of the kurtosis is independent of both the material mass and particle size.In the initial fluidization stage,the dominant pressure signal comes from the material movement;with the increase in the gas velocity,the power of a 2.5 Hz signal continues to increase.A method of dividing the main frequency by the average cycle frequency can conveniently determine the fluidized state,and a novel concept called stable fluidized zone proposed in this paper can be obtained.Controlling the gas velocity within the stable fluidized zone ensures that the fluidized bed consistently remains in a stable fluidized state. 展开更多
关键词 Conical fluidized bed Negative pressure pressure fluctuation Time-series analysis Characteristic value Fluidized state
下载PDF
Analysis on the Pressure Fluctuation Law of a Hydraulic Exciting System with a Wave-exciter 被引量:1
13
作者 WEI Xiu-ye KOU Zi-ming LU Zi-rong 《International Journal of Plant Engineering and Management》 2011年第4期208-214,共7页
A hydraulic exciting system with a wave exciter has been constructed in order to study the hydraulic vibra- tion law. The system consists of an oil source, wave-exciter and oil cylinder, and is controlled by a wave-ex... A hydraulic exciting system with a wave exciter has been constructed in order to study the hydraulic vibra- tion law. The system consists of an oil source, wave-exciter and oil cylinder, and is controlled by a wave-exciter. The working principle of the hydraulic exciting system and wave exciter has been analyzed, and its excitation process has been illustrated. The law of every pipe's pressure fluctuation of the system is obtained by experiment. The theo- retical analysis and experimental data prove that the pipeline pressure periodically changes and the pipeline pressure fluctuation frequency is independently controlled by the excitation frequency of the wave-exciter. Every pipelinc's pressure wave is produced by system flow fluctuation and water hammer coupling. The pressure fluctuation rules of the system provide a theoretical basis for the study of the associated liberation system. 展开更多
关键词 hydraulic exciting system wave-exciter pressure fluctuation
下载PDF
Impact of intraocular pressure fluctuations on progression of normal tension glaucoma
14
作者 Susanne Hopf Doris Schwantuschke +2 位作者 Irene Schmidtmann Norbert Pfeiffer Esther Maria Hoffmann 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第10期1553-1559,共7页
AIM:To investigate short-and long-term intraocular pressure(IOP)fluctuations and fur ther ocular and demographic parameters as predictors for normal tension glaucoma(NTG)progression.METHODS:This retrospective,longitud... AIM:To investigate short-and long-term intraocular pressure(IOP)fluctuations and fur ther ocular and demographic parameters as predictors for normal tension glaucoma(NTG)progression.METHODS:This retrospective,longitudinal cohort study included 137 eyes of 75 patients with NTG,defined by glaucomatous optic disc or visual field defect with normal IOP(<21 mm Hg),independently from therapy regimen.IOP fluctuation,mean,and maximum were inspected with a mean follow-up of 38 mo[standard deviation(SD)18 mo].Inclusion criteria were the performance of minimum two 48-hour profiles including perimetry,Heidelberg retina tomograph(HRT)imaging,and optic disc photographs.The impact of IOP parameters,myopia,sex,cup-to-disc-ratio,and visual field results on progression of NTG were analyzed using Cox regression models.A sub-group analysis with results from optical coherence tomography(OCT)was performed.RESULTS:IOP fluctuations,average,and maximum were not risk factors for progression in NTG patients,although maximum IOP at the initial IOP profile was higher in eyes with progression than in eyes without progression(P=0.054).The 46/137(33.5%)eyes progressed over the followup period.Overall progression(at least three progression confirmations)occurred in 28/137 eyes(20.4%).Most progressions were detected by perimetry(36/46).Longterm IOP mean over all pressure profiles was 12.8 mm Hg(SD 1.3 mm Hg);IOP fluctuation was 1.4 mm Hg(SD 0.8 mm Hg).The progression-free five-year rate was 58.2%(SD 6.5%).CONCLUSION:Short-and long-term IOP fluctuations do not result in progression of NTG.As functional changes are most likely to happen,NTG should be monitored with visual field testing more often than with other devices. 展开更多
关键词 intraocular pressure intraocular pressure fluctuation glaucoma progression visual field OPTICAL optical coherence tomography
下载PDF
Induction of significant intraocular pressure diurnal fluctuation in rats using a modified technique of microbead occlusion
15
作者 Lin Fu Jimmy Shiu Ming Lai +1 位作者 Amy Cheuk Yin Lo Kendrick Co Shih 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1114-1119,共6页
AIM: To investigate the effect of microbead iridocorneal angle occlusion on intraocular pressure(IOP) diurnal fluctuation in rat eyes. METHODS: Male Dark Agouti(DA) rats, 8-10 week old, were each given a single ... AIM: To investigate the effect of microbead iridocorneal angle occlusion on intraocular pressure(IOP) diurnal fluctuation in rat eyes. METHODS: Male Dark Agouti(DA) rats, 8-10 week old, were each given a single intracameral injection of microbeads, followed by injection of dispersive viscoelastic solution. The right eye served as the experimental eye, while the left eye served as the control. IOP was measured twice daily postoperatively for 3 wk and compared between groups. At the end of 3 wk, the rats were sacrificed and the eyes were harvested for histological analysis and retinal ganglion cell(RGC) counting. RESULTS: After microbead injection, experimental eyes had significantly higher dark time IOP than controls from the second week to the third week [2 nd week: 22.92±1.631 mm Hg(n=5) vs 17.35±0.751 mm Hg(n=5); 3 rd week: 23.59±1.494 mm Hg vs 17.73±0.592 mm Hg(n=5)], while light time IOP was comparable between groups. The fluctuation levels of IOP in the experimental eyes were 7.21±0.398 mm Hg(n=5), 9.50±1.017 mm Hg(n=5) and 10.66±0.894 mm Hg(n=5) from the first week to the third week after injection. Comparatively, they were significantly lower in the control eyes, which were 4.69±0.323 mm Hg(n=5), 2.84±1.122 mm Hg(n=5) and 4.98±0.603 mm Hg(n=5) respectively. However, at the end of 3 wk, the larger fluctuations in IOP in the experimental eyes was not associated with a significant loss of RGCs. CONCLUSION: Microbead occlusion exacerbates diurnal IOP fluctuation in rats. This reported model may serve as a method of investigating the pathological effects of IOP fluctuation. A longer observation period, or repeated injections, may be needed to observe a significant change in RGC density. 展开更多
关键词 microbead occlusion diurnal intraocular pressure fluctuation GLAUCOMA rat
下载PDF
Influence of Plasma Pressure Fluctuation on RF Wave Propagation
16
作者 刘智惟 包为民 +2 位作者 李小平 刘东林 周辉 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第2期131-137,共7页
Pressure fluctuations in the plasma sheath from spacecraft reentry affect radiofrequency(RF) wave propagation.The influence of these fluctuations on wave propagation and wave properties is studied using methods deri... Pressure fluctuations in the plasma sheath from spacecraft reentry affect radiofrequency(RF) wave propagation.The influence of these fluctuations on wave propagation and wave properties is studied using methods derived by synthesizing the compressible turbulent flow theory,plasma theory,and electromagnetic wave theory.We study these influences on wave propagation at GPS and Ka frequencies during typical reentry by adopting stratified modeling.We analyzed the variations in reflection and transmission properties induced by pressure fluctuations.Our results show that,at the GPS frequency,if the waves are not totally reflected then the pressure fluctuations can remarkably affect reflection,transmission,and absorption properties.In extreme situations,the fluctuations can even cause blackout.At the Ka frequency,the influences are obvious when the waves are not totally transmitted.The influences are more pronounced at the GPS frequency than at the Ka frequency.This suggests that the latter can mitigate blackout by reducing both the reflection and the absorption of waves,as well as the influences of plasma fluctuations on wave propagation.Given that communication links with the reentry vehicles are susceptible to plasma pressure fluctuations,the influences on link budgets should be taken into consideration. 展开更多
关键词 plasma sheath pressure fluctuation wave propagation
下载PDF
EXPERIMENTAL STUDY ON INFLUENCE OF SUPPLIED PRESSURE FLUCTUATION ON OUTPUT ARACTERISTIC OF PRESSURE CONTROL SYSTEM OF ROLLING MILL 被引量:1
17
作者 Zhao Jingyi Li Jiutong Wang Yiqun Yanshan University 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 1998年第2期73-79,共7页
The infulence of supplied pressure fluctuation on output accuracy for the electro hydraulic pressure control system of the rolling mill is discussed.Based on the bond graph theory and experimental study,the relations... The infulence of supplied pressure fluctuation on output accuracy for the electro hydraulic pressure control system of the rolling mill is discussed.Based on the bond graph theory and experimental study,the relationship between the variation of system output pressure and the supplied pressure fluctuation and the influence of the system bandwidth on system output pressure are provided.A theoretical base for determining the allowable fluctuation range of pressure and accurate design of constant pressure source system is obtained. 展开更多
关键词 pressure fluctuation pressure control system Bond graph
全文增补中
Postoperative Delirium in Elderly Patients May be Associated with Perioperative Blood Pressure Fluctuations
18
作者 Daxu Peng Qingchen Liu +1 位作者 Xiuyang Cao Guanwen Deng 《Journal of Geriatric Medicine》 2021年第1期6-11,共6页
Postoperative delirium(PD)is a common complication of surgery in elderly patients,but its pathophysiological mechanism remains unclear.In order to clarify the role of intraoperative hypotension and fluctuation of bloo... Postoperative delirium(PD)is a common complication of surgery in elderly patients,but its pathophysiological mechanism remains unclear.In order to clarify the role of intraoperative hypotension and fluctuation of blood pressure in the development of PD,we conducted a follow-up study in elderly patients with intraoperative hypotension and fluctuation of blood pressure.A total of 237 patients underwent hip surgery between July 2018 and September 2019,and 158 patients who were eligible for inclusion were enrolled in the study.One day before the operation,the mentality of patients was evaluated by Mini-mental State Examina­tion(MMSE),and the sex,age,height,and weight of the patients were recorded.Radial artery puncture was performed in all patients before anesthesia,intraoperative SBP,MAP and DBP were recorded,and the surgical events of the patients was recorded.The markers associated with PD(TNF-α,IL-6 and S-100β)were determined before and after surgery.Perioperative delirium(PD)was assessed by the prevailing standard of assessment,Confusion of Consciousness Assessment(CAM).Cognitive assessment was evaluated using the Mini-mental State Examination(MMSE).In addition,the timing and type of delirium were recorded.There were 158 patients which were accorded with the inclusion criteria came into the study.The results of our data showed that delirium occurred in 41 patients(25.9%)during the first week after surgery.In the compar­ison between the PD group and the non-PD group,it was found that the patients with postoperative delirium were older,lower body mass index and higher MMSE score before operation.Intraoperative blood pressure is low,usually more than 30%lower than preoperative blood pressure.The levels of TNF-α,IL-6 and Smur100βwere higher after operation.The increased incidence of postoperative delirium may be related to in­traoperative hypotension and intraoperative blood pressure fluctuation.The pathophysiological mechanism may be that hypotension causes low cerebral perfusion,which in turn causes local inflammation in the brain.In addition,postoperative delirium is also more likely to occur in older patients with lower body mass index. 展开更多
关键词 Perioperative period Blood pressure fluctuation Postoperative delirium
下载PDF
A Unique Modelling Strategy to Dynamically Simulate the Performance of a Lobe Pump for Industrial Applications
19
作者 Deepak Kumar Kanungo Rabiranjan Murmu Harekrushna Sutar 《Advances in Chemical Engineering and Science》 CAS 2024年第2期57-73,共17页
The performance of a newly designed tri-lobe industrial lobe pump of high capacity is simulated by using commercial CFD solver Ansys Fluent. A combination of user-defined-functions and meshing strategies is employed t... The performance of a newly designed tri-lobe industrial lobe pump of high capacity is simulated by using commercial CFD solver Ansys Fluent. A combination of user-defined-functions and meshing strategies is employed to capture the rotation of the lobes. The numerical model is validated by comparing the simulated results with the literature values. The processes of suction, displacement, compression and exhaust are accurately captured in the transient simulation. The fluid pressure value remains in the range of inlet pressure value till the processes of suction and displacement are over. The instantaneous process of compression is accurately captured in the simulation. The movement of a particular working chamber is traced along the gradual degree of lobe’s rotation. At five different degrees of lobe’s rotation, pressure contour plots are reported which clearly shows the pressure values inside the working chamber. Each pressure value inside the working chamber conforms to the particular process in which the working chamber is operating. Finally, the power requirement at the shaft of rotation is estimated from the simulated values. The estimated value of power requirement is 3.61 BHP FHP whereas the same calculated theoretically is 3 BHP FHP. The discrepancy is attributed to the assumption of symmetry of blower along the thickness. 展开更多
关键词 CFD Lobe Pump Moving Dynamic Mesh pressure fluctuation Transient Simulation
下载PDF
Analysis of the relationship between water level fluctuation and seismicity in the Three Gorges Reservoir(China) 被引量:4
20
作者 Lifen Zhang Jinggang Li +3 位作者 Guichun Wei Wulin Liao Qiuliang Wang Chuanfang Xiang 《Geodesy and Geodynamics》 2017年第2期96-102,共7页
The Three Gorges Reservoir is a good site for the further researches on reservoir induced seismicity due to decades' seismic monitoring. After the first water impounding in 2003, seismic activity becomes more frequen... The Three Gorges Reservoir is a good site for the further researches on reservoir induced seismicity due to decades' seismic monitoring. After the first water impounding in 2003, seismic activity becomes more frequent than that before water impoundment. In order to quantitatively study, the relationship between the water level fluctuation and earthquakes in TGR, we introduced statistical methods to attain the goal. First of all, we relocated the earthquakes in TGR region with double difference method and divided the earthquakes into 5 clusters with clustering analysis method. Secondly, to examine the impacts of water level fluctuation in different water filling stages on the seismic activity in the 5 clusters, a series of statistical analyses are applied. Pearson correlation results show that only the 175 m water level fluc- tuation has significantly positive impacts on the seismic activity in clusters I, II, III and V with correlation coefficients of 0.44, 0.38, 0.66 and 0.63. Cross-correlation analysis demonstrates that 0, ], 0 and 0 month time delay separately for the clusters I, II, III and V exists. It illustrated the influences of the water loading and pore pressure diffusion on induced earthquakes. Cointegration tests and impulse response analysis denoted that the 175 m water level only had long term and significant effects just on the seismic events in the intersection region of the Fairy Mount Fault and Nine-brook Fault. One standard deviation shock to 175 m water level increased the seismic activity in cluster V for the first 3 months, and then the negative influence was shown. After 7 months, the negative impulse response becomes stable. The long-term effect of the 175 m water impoundment also proved the important role of pore pressure diffusion in RIS with time. 展开更多
关键词 Three Gorges Reservoir Reservoir-induced seismicity Water level fluctuation Cross correlation Impulse response Pore pressure diffusion
下载PDF
上一页 1 2 6 下一页 到第