A new fluid bag buffer mechanism,which can provide large axial stiffness under the small displacement,is designed.The dynamic change laws of the mechanism stiffness and the internal pressure of the fluid bag are studi...A new fluid bag buffer mechanism,which can provide large axial stiffness under the small displacement,is designed.The dynamic change laws of the mechanism stiffness and the internal pressure of the fluid bag are studied when it is subjected to impact load.According to the protection performance for the flexible joint and the pressure change in the fluid bag during the impact process,the sensitivity of the geometric parameters of the fluid bag to the axial stiffness is analyzed by using the orthogonal experimental method,and the optimal parameter combination of the geometric parameters of the fluid bag under impact is obtained,leading to the displacement of the inner shell reduce by 41.4%.The results show that the internal pressure of the fluid bag is a rising process of oscillation and fluctuation.The sensitivity of the geometric parameters of the fluid bag to the displacement of the inner shell from high to low is as follows:Height H,radius r,wall thickness t,chamfer A.The correlation between the geometric parameters of the fluid bag and its internal pressure is:H is negatively correlated with the internal pressure,while the r,t,and A are positively correlated with the internal pressure.展开更多
Abdominal drainage was previously recommended as a post-hepatectomy procedure for patients with cirrhosis.This report introduces a simple technique that prevents leakage of ascitic fluid after cirrhotic hepatectomy co...Abdominal drainage was previously recommended as a post-hepatectomy procedure for patients with cirrhosis.This report introduces a simple technique that prevents leakage of ascitic fluid after cirrhotic hepatectomy complicated by blockage of the abdominal drain.In 59 patients who had had cirrhotic hepatectomy complicated by leakage of ascites in the drain site after drainage removal between January 2001 and April 2011,31 underwent suture ligation(sutured group) and 28 were given urostomy bag at the abdominal drainage site(drainage group).The mean length of postoperative hospital stay in the drainage group was shorter than in the sutured group(16.11±2.61 vs 34.23±4.86 days,P=0.000).Meanwhile,the drainage group showed decreased postoperative complications,including leakage of ascites,wound infection,and collection of ascites.Drainage by urostomy bag can prevent prolonged leakage of ascitic fluid after the blockage of abdominal drains in patients undergoing cirrhotic hepatectomy.展开更多
基金supported by the Fun⁃damental Scientific Research Business Expenses of Central Universities(No.NJ2020024).
文摘A new fluid bag buffer mechanism,which can provide large axial stiffness under the small displacement,is designed.The dynamic change laws of the mechanism stiffness and the internal pressure of the fluid bag are studied when it is subjected to impact load.According to the protection performance for the flexible joint and the pressure change in the fluid bag during the impact process,the sensitivity of the geometric parameters of the fluid bag to the axial stiffness is analyzed by using the orthogonal experimental method,and the optimal parameter combination of the geometric parameters of the fluid bag under impact is obtained,leading to the displacement of the inner shell reduce by 41.4%.The results show that the internal pressure of the fluid bag is a rising process of oscillation and fluctuation.The sensitivity of the geometric parameters of the fluid bag to the displacement of the inner shell from high to low is as follows:Height H,radius r,wall thickness t,chamfer A.The correlation between the geometric parameters of the fluid bag and its internal pressure is:H is negatively correlated with the internal pressure,while the r,t,and A are positively correlated with the internal pressure.
基金supported by grants from the International Collaborational Foundation of Jiangsu Province (BZ2011041,ZX05200904 and WS2011106)the National Nature Science Foundation of China (81100270 and 81070380)
文摘Abdominal drainage was previously recommended as a post-hepatectomy procedure for patients with cirrhosis.This report introduces a simple technique that prevents leakage of ascitic fluid after cirrhotic hepatectomy complicated by blockage of the abdominal drain.In 59 patients who had had cirrhotic hepatectomy complicated by leakage of ascites in the drain site after drainage removal between January 2001 and April 2011,31 underwent suture ligation(sutured group) and 28 were given urostomy bag at the abdominal drainage site(drainage group).The mean length of postoperative hospital stay in the drainage group was shorter than in the sutured group(16.11±2.61 vs 34.23±4.86 days,P=0.000).Meanwhile,the drainage group showed decreased postoperative complications,including leakage of ascites,wound infection,and collection of ascites.Drainage by urostomy bag can prevent prolonged leakage of ascitic fluid after the blockage of abdominal drains in patients undergoing cirrhotic hepatectomy.