Introduction: Forearm fractures involving both the radius and ulna, present distinctive challenges in orthopedic trauma management. This case report explores the complexities of a rare case of bilateral fractures, emp...Introduction: Forearm fractures involving both the radius and ulna, present distinctive challenges in orthopedic trauma management. This case report explores the complexities of a rare case of bilateral fractures, emphasizing the importance of a comprehensive approach for optimal outcomes. Case Presentation: This report presents the case of a 40-year-old motorcyclist who was involved in a road accident and arrived at the emergency department shortly after the incident. Clinical examination revealed closed fractures in both forearms with mild swelling and severe tenderness. Fortunately, no neurovascular issues or compartment syndrome were detected. The patient was administered intravenous fluids and effective pain relief. Forearm splints were applied and the arms were elevated using pillows. Radiographs showed fractures in the right distal radius and ulna, as well as the left mid-shaft radius and ulna. Under general anesthesia, open reduction and internal fixation were per-formed using plates and screws for all four fractures. Postoperatively, the patient’s arms were immobilized and elevated, with gradual recovery during follow-up appointments over six months, eventually achieving full function without complaints. Conclusion: This article highlights the possibility, although infrequent, of bilateral shaft fractures of the ulna and radius. With thorough clinical assessment and radiological investigation, such fractures can be well-defined. The required definitive treatment, which usually involves open reduction and internal fixation, can be performed.展开更多
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ...Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.展开更多
Objective:The incidence of distal radius fracture combined with ulnar styloid process fracture is increasing,which seriously affects the quality of life of patients.Small splint therapy of Traditional Chinese Medicine...Objective:The incidence of distal radius fracture combined with ulnar styloid process fracture is increasing,which seriously affects the quality of life of patients.Small splint therapy of Traditional Chinese Medicine is a reliable method for the treatment of such fractures.It not only has good clinical efficacy,but also has fewer complications and high safety.However,the traditional small splint fixation does not cover the styloid process of the ulna,and the fracture of the styloid process of the ulna is closely related to the stability of the wrist joint,which has an important impact on the prognosis of the fracture.Based on this,we believe that the ulnar elongation splint can better improve the wrist function,and further prospects for related issues,in order to guide clinical practice.展开更多
60% of a dog's body weight is supported by its fore limbs, while the hind limbs mainly play the role of power, so the probability of dog's radius and ulna fracture is greatly increased. This paper mainly intro...60% of a dog's body weight is supported by its fore limbs, while the hind limbs mainly play the role of power, so the probability of dog's radius and ulna fracture is greatly increased. This paper mainly introduced the diagnosis and treatment of a case of radius and ulna fracture in dog, with an attempt to provide reference for clinical practice.展开更多
Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically....Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically. A key method of surgical fixation is external fixation by distractor. Distractor can be applied either only on the radial side or on both ulnar and radial sides. Materials and Methods: A prospective randomized and comparative study of 1 year duration was conducted on 32 patients admitted in the Department of Orthopaedics of BSMC & H in the age group of 20 to 75 years old with AO types B and C distal radius fracture along with involvement of the ulnar styloid process. The parameters studied were restoration of radial length, restoration of radial angle, intracarpal step-off and palmar tilt which were statistically evaluated and Fisher’s exact test was performed. The two tailed P-value was calculated and both the groups were statistically compared. Results: In our study, 37.5% patients in Group A and 81.25% in Group B had a radial difference Table 1, Chart 1). 43.75% patients in Group A and 87.5% in Group B had radial angle Table 2, Chart 2). 31.25% in Group A and 75% had intra carpal step off Table 3, Chart 3). 62.5% had an abnormal palmar tilt in Group A while only 6.25% had an abnormal palmar tilt in Group B which is extremely statistically significant. On an average, 2 mm of distraction was required in 75% patients of Group A while only 30% patients in Group B required distraction (Table 4, Chart 4). Conclusion: In our study, the radial difference, radial angle, intra carpal step off and palmar tilt returned significantly to normal in the patients treated with distractor on radial side only when compared with distractor application on both radial and ulnar sides for distal radius fracture with ulnar styloid process involvement. Also post-operative distraction required under image intensifier was higher in the group treated with distractor on either side than those with distractor only on radial side.展开更多
BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with lon...BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with long-term follow-up is required to validate these initial findings.AIM To review the literature on the outcomes of distal radius hemiarthroplasty with available implants to assess its viability as a treatment option.METHODS A comprehensive review of the literature was conducted using electronic databases,including PubMed,Medline,and Scopus.The search terms employed were"distal radius fracture","hemiarthroplasty","wrist arthroplasty",and related terminology.The search was restricted to articles published in English from 1980 until June 2023.Inclusion criteria encompassed cases or case series of DRF treated with hemiarthroplasty,providing clinical or radiographic outcomes,and published in peer-reviewed journals.RESULTS A total of 2508 articles from PubMed and 883 from Scopus were identified initially.Following screening and removal of duplicates,13 articles met the inclusion criteria.These articles,predominantly clinical retrospective studies,provided insights into hemiarthroplasty outcomes,including functional improvements and complications.Hemiarthroplasty was a treatment option for complex DRF,particularly those cases with severe comminution,intraarticular involvement,or severe osteoporosis.Functional outcomes demonstrated improvements in pain relief,wrist mobility,and grip strength,with variability across studies.Complications included implant loosening,infection,nerve injury,and stiffness,with varying incidence rates influenced by surgical techniques and implant choice.Long-term outcomes were inadequately documented,warranting further research.CONCLUSION Hemiarthroplasty is a promising treatment for irreparable DRF in the elderly.Long-term outcomes and complications require further study.展开更多
BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower lim...BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower limb fracture surgery.LEDVT and PTE after upper extremity fracture surgery are very rare.PTE is one of the most common clinical causes of sudden death.Venous thromboembolism includes PTE and DVT.We experienced one case of LEDVT and PTE after distal ulna and radius fracture surgery.The purpose of our report is to raise awareness for orthopedic surgeons that PTE can occur after distal ulna and radius fracture surgery,and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.CASE SUMMARY We report a 51-year-old Chinese male who had severe fractures of the left distal ulna,radius and little finger after a motorcycle accident.The patient underwent external fixation,open reduction and internal fixation.On the third post-operative day,computed tomographic pulmonary angiography showed PTE.Doppler ultrasonography showed thrombus formation in the bilateral posterior tibial veins.After a period of anticoagulation therapy,on the 25th d after the PTE,computed tomographic pulmonary angiography showed that thrombus in both sides of the pulmonary artery disappeared.Furthermore,about 4 mo after the PTE,thrombosis in the deep veins of the lower limbs disappeared.About 1 year after the surgery,X-rays showed good fracture healing,and the function of the wrist joint recovered well.CONCLUSION Though rare,PTE can occur after distal ulna and radius fracture surgery and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.展开更多
Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes...Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination of the influence of fracture gap fill ratio (defined as the proportion of the fracture gap that is filled by the expanding balloon as the polymer is injected into the balloon) on a large collection of quantitative biomechanical parameters.展开更多
<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Wheth...<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Whether anesthesia type affects patient outcomes is unclear. </span><span>This study retrospectively compared patient satisfaction between GA and NB after surgery. </span><b><span>Methods: </span></b><span>This was a historical cohort study of 80 (34 GA and 46 NB) patients who underwent volar plate fixation of distal radius fractures. Propensity score analysis was used to generate a set of matched cases (NB) and controls (GA), yielding 14 matched patient-pairs. The simplified patient satisfaction scale was compared for primary outcomes. Secondary outcomes were anesthesia and surgery duration, hospital stay length, adverse events, postoperative analgesic requirement, and wrist range of motion (ROM) 2 weeks and 3 months postoperatively.</span><span> </span><b><span>Results:</span></b><span> After propensity score matching, patients in almost all cases in both groups were “Satisfied” (effect size: 0.1, p</span><span> </span><span>=</span><span> </span><span>0.572), indicating little significant difference. Significant differences in adverse events and postoperative analgesic use observed before matching disappeared after matching. Anesthesia duration and hospital stay length were significantly shorter in the NB group (effect size: </span><span>-</span><span>1.27 and </span><span>-</span><span>0.77, p</span><span> </span><span>=</span><span> </span><span>0.00074 and p</span><span> </span><span>=</span><span> </span><span>0.0388, respectively), as was surgery duration (effect size: </span><span>-</span><span>0.84, p</span><span> </span><span>=</span><span> </span><span>0.0122) after matching. Similar to before matching, wrist ROM significantly improved in the NB group (effect size: 1.11, p</span><span> </span><span>=</span><span> </span><span>0.0279) in the early postoperative period, but the difference disappeared at 3 months postoperatively.</span><span> </span><b><span>Conclusions:</span></b><span> Patient satisfaction between distal radius fracture surgery under GA and NB was similar. Nerve block could help shorten hospital stay length and surgery duration and improve postoperative functional recovery.</span>展开更多
Distal radius fracture is the most common fracture site of the human skeleton[1]and often occurs in young people resulting from high energy injury caused by severe trauma.However,complex distal radial intra-articular ...Distal radius fracture is the most common fracture site of the human skeleton[1]and often occurs in young people resulting from high energy injury caused by severe trauma.However,complex distal radial intra-articular fractures(AO type C3)are relatively rare and account for about 5%of all distal radius fractures.[2]Fracture comminution at the joint surface is the primary manifestation of these fractures,followed by avulsion of the bone fragments with displacement seen at both the metacarpal and ulnar bone.Treatment of these displaced and unstable fractures remains a challenge.The nature of the articular surface fracture indicates the use of either the open or close reduction technique.Treatment protocols focus on extra-articular reduction and restoration of radial length,maintaining the volar tilt.[3,4]It has been noted that incongruity of the intra-articular distal radius fracture is relevant to the development of arthritis.[5,6]展开更多
Introduction: Since distal radius fractures are among the most common fractures encountered in orthopedics and one of their common complications is restriction of rotational movements of the wrist and forearm, iden-ti...Introduction: Since distal radius fractures are among the most common fractures encountered in orthopedics and one of their common complications is restriction of rotational movements of the wrist and forearm, iden-tification of factors affecting this loss of motion is of importance. This study was conducted to evaluate the relation between extraarticular distal radius fractures associated with fracture of ulnar styloid and the rota-tional movements of the wrist and forearm. Patients and methods: 47 patients with an extraarticular distal radius fracture were enrolled in a prospective case control study. The patients were visited in regular follow up intervals after treatment and at the final follow up the rotational movements of the forearm were measured. The findings were analyzed with Independent T and Chi-square tests. Findings: Ultimately 23 patients of the group 1 (intact ulnar styloid) and 24 of the group 2 (fractured ulnar styloid) completed the follow up period. At this time supination of the wrist and forearm in group 2 was significantly less than the group 1 (p< 0.001). Conclusion: It seems that the association of an extraarticular distal radius fracture with the fracture of ulnar styloid, at least in short term causes restriction of supination of the forearm, though the mechanism and clinical significance of this finding cannot be easily explained.展开更多
Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element ana...Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.展开更多
The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters fol...The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after I week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P = 0.001), supination, (P = 0.047) and extension (P = 0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at I year. The plating group had a greater occurrence of wound infection (P = 0.043), tendonitis, (P = 0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the "gross motor" category (walking upstairs, bending over, walking 500 yards; P = 0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after I year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries.展开更多
Radial head and neck fractures represent up to 14%of all pediatric elbow fractures and can be a difficult challenge in the pediatric patient.In up to 39%of proximal radius fractures,there is a concomitant fracture,whi...Radial head and neck fractures represent up to 14%of all pediatric elbow fractures and can be a difficult challenge in the pediatric patient.In up to 39%of proximal radius fractures,there is a concomitant fracture,which can easily be overlooked on the initial standard radiographs.The treatment options for proximal radius fractures in children range from non-surgical treatment,such as immobilization alone and closed reduction followed by immobilization,to more invasive options,including closed reduction with percutaneous pinning and open reduction with internal fixation.The choice of treatment depends on the degree of angulation and displacement of the fracture and the age of the patient;an angulation of less than 30 degrees and translation of less than 50%is generally accepted,whereas a higher degree of displacement is considered an indication for surgical intervention.Fractures with limited displacement and non-surgical treatment generally result in superior outcomes in terms of patient-reported outcome measures,range of motion and complications compared to severely displaced fractures requiring surgical intervention.With proper management,good to excellent results are achieved in most cases,and long-term sequelae are rare.However,severe complications do occur,including radio-ulnar synostosis,osteonecrosis,rotational impairment,and premature physeal closure with a malformation of the radial head as a result,especially after more invasive procedures.Adequate follow-up is therefore warranted.展开更多
BACKGROUND Distal radius fractures accompanied by the volar margin of the lunate fossa(VMLF)lesions are often overlooked or inadequately reduced in clinical practice.AIM To investigate the impact of VMLF fragment in d...BACKGROUND Distal radius fractures accompanied by the volar margin of the lunate fossa(VMLF)lesions are often overlooked or inadequately reduced in clinical practice.AIM To investigate the impact of VMLF fragment in distal radius fractures on the stability and function of the wrist joint.METHODS This was a retrospective study of patients with distal radius fractures who underwent surgical treatment between January 2013 and December 2017.The patients were divided into two groups according to whether the VMLF fragments were fixed or not.X-rays and computed tomography were performed before surgery,immediately postoperatively,and at 1,3,and 6 mo to measure the scapholunate angle,radiolunate angle,capitolunate angle,and effective radiolunate flexion(ERLF).The Mayo wrist score and disabilities of the arm,shoulder,and hand(DASH)score were determined at 1 year.RESULTS Thirty-five patients were included.There were 15 males and 20 females.Their mean age was 52.5±14.3(range:19-70)years.There were 38 wrists(17 on the left side,15 on the right,and three bilateral;16 in the fixed group,and 22 in the unfixed group).The interval between trauma and surgery was from 1 h to 1 mo.The incidence of postoperative wrist instability in the unfixed group(86.4%)was higher than in the fixed group(25.0%)(P≤0.001).Ten patients had ERLF>25°in the unfixed group and none in the fixed group(P=0.019).The Mayo wrist score was 94±5.7 in the fixed group and 68±15.1 in the unfixed group(P<0.001).The DASH score was 4.6±2.5 in the fixed group and 28.5±19.5 in the unfixed group(P<0.001).CONCLUSION Injuries of VMLF,even small fractures,might damage the radial-lunar ligament,leading to postoperative wrist instability,sagittal force line imbalance,and poor recovery of wrist joint function.展开更多
AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ...AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ± 18 years) who had X-ray(CR) and computed tomography(CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex(PQC) was measured using lateral views(CR) and sagittal reconstructions(CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign(PQS) was defined as a PQC > 8.0 mm(female) or > 9.0 mm(male). Frykman classification was utilized to assess the severity of fractures.RESULTS Forty-four/89 patients(49%) had a distal radius fracture(Frykman Ⅰ n = 3, Ⅱ n = 0, Ⅲ n = 10, Ⅳ n = 5, Ⅴ n = 2, Ⅵ n = 2, Ⅶ n = 9, Ⅷ n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views(CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions(CT), resulting in a significant correlation coefficientof 0.795. A positive PQS at CR was present in 21/44 patients(48%) with distal radius fracture and in 2/45 patients(4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures.CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.展开更多
According to the specimens of ulna-radius of the Cape Hare (Lepus capensie) shot in fall and winter in Shanxi province, China, the ossifications of epiphyses cartilage of ulna-radius are divided into 4 stages. With we...According to the specimens of ulna-radius of the Cape Hare (Lepus capensie) shot in fall and winter in Shanxi province, China, the ossifications of epiphyses cartilage of ulna-radius are divided into 4 stages. With weight of eye lens as a reference, it is proved that the age criterion could be used to distinguish young less than 6–7 months old from those older. This is a pragmatic method to analyze age composition of game-bag in the early period of shooting season when younger holds a large proportion in the hare population. It also is useful in judging the age of hares trapped and estimating the effects of predation on the hare population structure.展开更多
Madelung deformity is rare, accounting for 1.7% of congenital anomalies. The treatment is essentially surgical and several techniques have been described. We report the result of a case treated in an adult patient by ...Madelung deformity is rare, accounting for 1.7% of congenital anomalies. The treatment is essentially surgical and several techniques have been described. We report the result of a case treated in an adult patient by a double osteotomy of the radius and ulna. The patient is satisfied.展开更多
Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius...Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius intra-arti-cular fractures were divided into two groups. Group I included 24 patients with type C fracture treated by external fixator augmented by percutaneous K-wires. Group II included 22 patients with type C fracture treated by volar locked distal radial plate augmented by K-wires. Two patients had complex injuries necessitating double plating (sandwich). All patients were evaluated clinically by Mayo Wrist Score and radiologically by Sarmiento’s radiological score. Results: Both groups reported good personal satisfaction according to Mayo Wrist Score, and the results were not statistically different between the two groups. In Group I, 19 patients (79.2%) had excellent radiological outcome and five patients (20.9%) had good radiological outcome according to Sarmiento’s radiological score. In Group II, 20 patients (90.9%) had excellent outcome, and two (9.1%) had good radiological outcome;there was no or insignificant deformity. Conclusions: Complex distal radial fractures can be treated either by external fixation (ligamentotaxis) or by locked pre-contoured plating. The clinical outcome of plating and external fixator in our study did not show any statistically significant difference. The radiological outcome had no correlation with the clinical outcome.展开更多
Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the pr...Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the present work, we used the finite element analysis method to compare the biomechanical performance of a model of a construct comprising a simulated distal radius fracture considered fixated using a notional intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis system (“fixator”) versus using a commercially-available volar locking plate (VP). The biomechanical parameters determined were longitudinal stiffness and factor of safety under each of the applied loads.?For the fixator model, 1) each of the biomechanical parameters was markedly influenced by fracture gap fill ratio (FGFR) (defined as the proportion of the volume of the fracture gap that is considered occupied by the expanded polymer-filled balloon)?but not by modulus of elasticity assigned to the polymer;2) with FGFR = 100%, stiffness was comparable to that of the Ti-6Al-4V alloy VP construct model;and 3) stiffness was within the range of literature values for stiffness of constructs comprising simulated fractures in fresh cadaveric distal radii fixated using metal volar locking plate. These results suggest that the fixator may be an alternative modality to metal volar plating and, as such, deserves further evaluation.展开更多
文摘Introduction: Forearm fractures involving both the radius and ulna, present distinctive challenges in orthopedic trauma management. This case report explores the complexities of a rare case of bilateral fractures, emphasizing the importance of a comprehensive approach for optimal outcomes. Case Presentation: This report presents the case of a 40-year-old motorcyclist who was involved in a road accident and arrived at the emergency department shortly after the incident. Clinical examination revealed closed fractures in both forearms with mild swelling and severe tenderness. Fortunately, no neurovascular issues or compartment syndrome were detected. The patient was administered intravenous fluids and effective pain relief. Forearm splints were applied and the arms were elevated using pillows. Radiographs showed fractures in the right distal radius and ulna, as well as the left mid-shaft radius and ulna. Under general anesthesia, open reduction and internal fixation were per-formed using plates and screws for all four fractures. Postoperatively, the patient’s arms were immobilized and elevated, with gradual recovery during follow-up appointments over six months, eventually achieving full function without complaints. Conclusion: This article highlights the possibility, although infrequent, of bilateral shaft fractures of the ulna and radius. With thorough clinical assessment and radiological investigation, such fractures can be well-defined. The required definitive treatment, which usually involves open reduction and internal fixation, can be performed.
基金2022 Key Specialty Construction Project of Traditional Chinese Medicine:Traditional Chinese Orthopedics and Traumatology Department (No.962042)2020 Regional Traditional Chinese Medicine (Orthopedics and Traumatology)Diagnosis and Treatment Center (Jin Wei Zhong[2020]No.5)。
文摘Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.
基金This study was spoorted by the Project supported by Special Fund for Basic Scientific Research Business Fees of Central Level Public Welfare Scientific Research Institutes"Special Fund for Seedling Cultivation"(ZZ11-084).
文摘Objective:The incidence of distal radius fracture combined with ulnar styloid process fracture is increasing,which seriously affects the quality of life of patients.Small splint therapy of Traditional Chinese Medicine is a reliable method for the treatment of such fractures.It not only has good clinical efficacy,but also has fewer complications and high safety.However,the traditional small splint fixation does not cover the styloid process of the ulna,and the fracture of the styloid process of the ulna is closely related to the stability of the wrist joint,which has an important impact on the prognosis of the fracture.Based on this,we believe that the ulnar elongation splint can better improve the wrist function,and further prospects for related issues,in order to guide clinical practice.
基金Supported by Top-notch Academic Programs Project of Jiangsu Higher Education Institutions(PPZY2015C230)
文摘60% of a dog's body weight is supported by its fore limbs, while the hind limbs mainly play the role of power, so the probability of dog's radius and ulna fracture is greatly increased. This paper mainly introduced the diagnosis and treatment of a case of radius and ulna fracture in dog, with an attempt to provide reference for clinical practice.
文摘Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically. A key method of surgical fixation is external fixation by distractor. Distractor can be applied either only on the radial side or on both ulnar and radial sides. Materials and Methods: A prospective randomized and comparative study of 1 year duration was conducted on 32 patients admitted in the Department of Orthopaedics of BSMC & H in the age group of 20 to 75 years old with AO types B and C distal radius fracture along with involvement of the ulnar styloid process. The parameters studied were restoration of radial length, restoration of radial angle, intracarpal step-off and palmar tilt which were statistically evaluated and Fisher’s exact test was performed. The two tailed P-value was calculated and both the groups were statistically compared. Results: In our study, 37.5% patients in Group A and 81.25% in Group B had a radial difference Table 1, Chart 1). 43.75% patients in Group A and 87.5% in Group B had radial angle Table 2, Chart 2). 31.25% in Group A and 75% had intra carpal step off Table 3, Chart 3). 62.5% had an abnormal palmar tilt in Group A while only 6.25% had an abnormal palmar tilt in Group B which is extremely statistically significant. On an average, 2 mm of distraction was required in 75% patients of Group A while only 30% patients in Group B required distraction (Table 4, Chart 4). Conclusion: In our study, the radial difference, radial angle, intra carpal step off and palmar tilt returned significantly to normal in the patients treated with distractor on radial side only when compared with distractor application on both radial and ulnar sides for distal radius fracture with ulnar styloid process involvement. Also post-operative distraction required under image intensifier was higher in the group treated with distractor on either side than those with distractor only on radial side.
文摘BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with long-term follow-up is required to validate these initial findings.AIM To review the literature on the outcomes of distal radius hemiarthroplasty with available implants to assess its viability as a treatment option.METHODS A comprehensive review of the literature was conducted using electronic databases,including PubMed,Medline,and Scopus.The search terms employed were"distal radius fracture","hemiarthroplasty","wrist arthroplasty",and related terminology.The search was restricted to articles published in English from 1980 until June 2023.Inclusion criteria encompassed cases or case series of DRF treated with hemiarthroplasty,providing clinical or radiographic outcomes,and published in peer-reviewed journals.RESULTS A total of 2508 articles from PubMed and 883 from Scopus were identified initially.Following screening and removal of duplicates,13 articles met the inclusion criteria.These articles,predominantly clinical retrospective studies,provided insights into hemiarthroplasty outcomes,including functional improvements and complications.Hemiarthroplasty was a treatment option for complex DRF,particularly those cases with severe comminution,intraarticular involvement,or severe osteoporosis.Functional outcomes demonstrated improvements in pain relief,wrist mobility,and grip strength,with variability across studies.Complications included implant loosening,infection,nerve injury,and stiffness,with varying incidence rates influenced by surgical techniques and implant choice.Long-term outcomes were inadequately documented,warranting further research.CONCLUSION Hemiarthroplasty is a promising treatment for irreparable DRF in the elderly.Long-term outcomes and complications require further study.
基金Shanghai Fengxian District Osteoarthropathy Clinical Diagnosis and Treatment Center,China,No.fxlczlzx-a-201704.
文摘BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower limb fracture surgery.LEDVT and PTE after upper extremity fracture surgery are very rare.PTE is one of the most common clinical causes of sudden death.Venous thromboembolism includes PTE and DVT.We experienced one case of LEDVT and PTE after distal ulna and radius fracture surgery.The purpose of our report is to raise awareness for orthopedic surgeons that PTE can occur after distal ulna and radius fracture surgery,and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.CASE SUMMARY We report a 51-year-old Chinese male who had severe fractures of the left distal ulna,radius and little finger after a motorcycle accident.The patient underwent external fixation,open reduction and internal fixation.On the third post-operative day,computed tomographic pulmonary angiography showed PTE.Doppler ultrasonography showed thrombus formation in the bilateral posterior tibial veins.After a period of anticoagulation therapy,on the 25th d after the PTE,computed tomographic pulmonary angiography showed that thrombus in both sides of the pulmonary artery disappeared.Furthermore,about 4 mo after the PTE,thrombosis in the deep veins of the lower limbs disappeared.About 1 year after the surgery,X-rays showed good fracture healing,and the function of the wrist joint recovered well.CONCLUSION Though rare,PTE can occur after distal ulna and radius fracture surgery and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.
文摘Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination of the influence of fracture gap fill ratio (defined as the proportion of the fracture gap that is filled by the expanding balloon as the polymer is injected into the balloon) on a large collection of quantitative biomechanical parameters.
文摘<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Whether anesthesia type affects patient outcomes is unclear. </span><span>This study retrospectively compared patient satisfaction between GA and NB after surgery. </span><b><span>Methods: </span></b><span>This was a historical cohort study of 80 (34 GA and 46 NB) patients who underwent volar plate fixation of distal radius fractures. Propensity score analysis was used to generate a set of matched cases (NB) and controls (GA), yielding 14 matched patient-pairs. The simplified patient satisfaction scale was compared for primary outcomes. Secondary outcomes were anesthesia and surgery duration, hospital stay length, adverse events, postoperative analgesic requirement, and wrist range of motion (ROM) 2 weeks and 3 months postoperatively.</span><span> </span><b><span>Results:</span></b><span> After propensity score matching, patients in almost all cases in both groups were “Satisfied” (effect size: 0.1, p</span><span> </span><span>=</span><span> </span><span>0.572), indicating little significant difference. Significant differences in adverse events and postoperative analgesic use observed before matching disappeared after matching. Anesthesia duration and hospital stay length were significantly shorter in the NB group (effect size: </span><span>-</span><span>1.27 and </span><span>-</span><span>0.77, p</span><span> </span><span>=</span><span> </span><span>0.00074 and p</span><span> </span><span>=</span><span> </span><span>0.0388, respectively), as was surgery duration (effect size: </span><span>-</span><span>0.84, p</span><span> </span><span>=</span><span> </span><span>0.0122) after matching. Similar to before matching, wrist ROM significantly improved in the NB group (effect size: 1.11, p</span><span> </span><span>=</span><span> </span><span>0.0279) in the early postoperative period, but the difference disappeared at 3 months postoperatively.</span><span> </span><b><span>Conclusions:</span></b><span> Patient satisfaction between distal radius fracture surgery under GA and NB was similar. Nerve block could help shorten hospital stay length and surgery duration and improve postoperative functional recovery.</span>
文摘Distal radius fracture is the most common fracture site of the human skeleton[1]and often occurs in young people resulting from high energy injury caused by severe trauma.However,complex distal radial intra-articular fractures(AO type C3)are relatively rare and account for about 5%of all distal radius fractures.[2]Fracture comminution at the joint surface is the primary manifestation of these fractures,followed by avulsion of the bone fragments with displacement seen at both the metacarpal and ulnar bone.Treatment of these displaced and unstable fractures remains a challenge.The nature of the articular surface fracture indicates the use of either the open or close reduction technique.Treatment protocols focus on extra-articular reduction and restoration of radial length,maintaining the volar tilt.[3,4]It has been noted that incongruity of the intra-articular distal radius fracture is relevant to the development of arthritis.[5,6]
文摘Introduction: Since distal radius fractures are among the most common fractures encountered in orthopedics and one of their common complications is restriction of rotational movements of the wrist and forearm, iden-tification of factors affecting this loss of motion is of importance. This study was conducted to evaluate the relation between extraarticular distal radius fractures associated with fracture of ulnar styloid and the rota-tional movements of the wrist and forearm. Patients and methods: 47 patients with an extraarticular distal radius fracture were enrolled in a prospective case control study. The patients were visited in regular follow up intervals after treatment and at the final follow up the rotational movements of the forearm were measured. The findings were analyzed with Independent T and Chi-square tests. Findings: Ultimately 23 patients of the group 1 (intact ulnar styloid) and 24 of the group 2 (fractured ulnar styloid) completed the follow up period. At this time supination of the wrist and forearm in group 2 was significantly less than the group 1 (p< 0.001). Conclusion: It seems that the association of an extraarticular distal radius fracture with the fracture of ulnar styloid, at least in short term causes restriction of supination of the forearm, though the mechanism and clinical significance of this finding cannot be easily explained.
文摘Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.
基金supported by National Natural Science Foundation of China Grant 81560350
文摘The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after I week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P = 0.001), supination, (P = 0.047) and extension (P = 0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at I year. The plating group had a greater occurrence of wound infection (P = 0.043), tendonitis, (P = 0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the "gross motor" category (walking upstairs, bending over, walking 500 yards; P = 0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after I year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries.
文摘Radial head and neck fractures represent up to 14%of all pediatric elbow fractures and can be a difficult challenge in the pediatric patient.In up to 39%of proximal radius fractures,there is a concomitant fracture,which can easily be overlooked on the initial standard radiographs.The treatment options for proximal radius fractures in children range from non-surgical treatment,such as immobilization alone and closed reduction followed by immobilization,to more invasive options,including closed reduction with percutaneous pinning and open reduction with internal fixation.The choice of treatment depends on the degree of angulation and displacement of the fracture and the age of the patient;an angulation of less than 30 degrees and translation of less than 50%is generally accepted,whereas a higher degree of displacement is considered an indication for surgical intervention.Fractures with limited displacement and non-surgical treatment generally result in superior outcomes in terms of patient-reported outcome measures,range of motion and complications compared to severely displaced fractures requiring surgical intervention.With proper management,good to excellent results are achieved in most cases,and long-term sequelae are rare.However,severe complications do occur,including radio-ulnar synostosis,osteonecrosis,rotational impairment,and premature physeal closure with a malformation of the radial head as a result,especially after more invasive procedures.Adequate follow-up is therefore warranted.
基金High Levels of Health Technical Personnel in Beijing City Health System,No.2013-3-050.
文摘BACKGROUND Distal radius fractures accompanied by the volar margin of the lunate fossa(VMLF)lesions are often overlooked or inadequately reduced in clinical practice.AIM To investigate the impact of VMLF fragment in distal radius fractures on the stability and function of the wrist joint.METHODS This was a retrospective study of patients with distal radius fractures who underwent surgical treatment between January 2013 and December 2017.The patients were divided into two groups according to whether the VMLF fragments were fixed or not.X-rays and computed tomography were performed before surgery,immediately postoperatively,and at 1,3,and 6 mo to measure the scapholunate angle,radiolunate angle,capitolunate angle,and effective radiolunate flexion(ERLF).The Mayo wrist score and disabilities of the arm,shoulder,and hand(DASH)score were determined at 1 year.RESULTS Thirty-five patients were included.There were 15 males and 20 females.Their mean age was 52.5±14.3(range:19-70)years.There were 38 wrists(17 on the left side,15 on the right,and three bilateral;16 in the fixed group,and 22 in the unfixed group).The interval between trauma and surgery was from 1 h to 1 mo.The incidence of postoperative wrist instability in the unfixed group(86.4%)was higher than in the fixed group(25.0%)(P≤0.001).Ten patients had ERLF>25°in the unfixed group and none in the fixed group(P=0.019).The Mayo wrist score was 94±5.7 in the fixed group and 68±15.1 in the unfixed group(P<0.001).The DASH score was 4.6±2.5 in the fixed group and 28.5±19.5 in the unfixed group(P<0.001).CONCLUSION Injuries of VMLF,even small fractures,might damage the radial-lunar ligament,leading to postoperative wrist instability,sagittal force line imbalance,and poor recovery of wrist joint function.
文摘AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ± 18 years) who had X-ray(CR) and computed tomography(CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex(PQC) was measured using lateral views(CR) and sagittal reconstructions(CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign(PQS) was defined as a PQC > 8.0 mm(female) or > 9.0 mm(male). Frykman classification was utilized to assess the severity of fractures.RESULTS Forty-four/89 patients(49%) had a distal radius fracture(Frykman Ⅰ n = 3, Ⅱ n = 0, Ⅲ n = 10, Ⅳ n = 5, Ⅴ n = 2, Ⅵ n = 2, Ⅶ n = 9, Ⅷ n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views(CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions(CT), resulting in a significant correlation coefficientof 0.795. A positive PQS at CR was present in 21/44 patients(48%) with distal radius fracture and in 2/45 patients(4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures.CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.
文摘According to the specimens of ulna-radius of the Cape Hare (Lepus capensie) shot in fall and winter in Shanxi province, China, the ossifications of epiphyses cartilage of ulna-radius are divided into 4 stages. With weight of eye lens as a reference, it is proved that the age criterion could be used to distinguish young less than 6–7 months old from those older. This is a pragmatic method to analyze age composition of game-bag in the early period of shooting season when younger holds a large proportion in the hare population. It also is useful in judging the age of hares trapped and estimating the effects of predation on the hare population structure.
文摘Madelung deformity is rare, accounting for 1.7% of congenital anomalies. The treatment is essentially surgical and several techniques have been described. We report the result of a case treated in an adult patient by a double osteotomy of the radius and ulna. The patient is satisfied.
文摘Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius intra-arti-cular fractures were divided into two groups. Group I included 24 patients with type C fracture treated by external fixator augmented by percutaneous K-wires. Group II included 22 patients with type C fracture treated by volar locked distal radial plate augmented by K-wires. Two patients had complex injuries necessitating double plating (sandwich). All patients were evaluated clinically by Mayo Wrist Score and radiologically by Sarmiento’s radiological score. Results: Both groups reported good personal satisfaction according to Mayo Wrist Score, and the results were not statistically different between the two groups. In Group I, 19 patients (79.2%) had excellent radiological outcome and five patients (20.9%) had good radiological outcome according to Sarmiento’s radiological score. In Group II, 20 patients (90.9%) had excellent outcome, and two (9.1%) had good radiological outcome;there was no or insignificant deformity. Conclusions: Complex distal radial fractures can be treated either by external fixation (ligamentotaxis) or by locked pre-contoured plating. The clinical outcome of plating and external fixator in our study did not show any statistically significant difference. The radiological outcome had no correlation with the clinical outcome.
文摘Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the present work, we used the finite element analysis method to compare the biomechanical performance of a model of a construct comprising a simulated distal radius fracture considered fixated using a notional intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis system (“fixator”) versus using a commercially-available volar locking plate (VP). The biomechanical parameters determined were longitudinal stiffness and factor of safety under each of the applied loads.?For the fixator model, 1) each of the biomechanical parameters was markedly influenced by fracture gap fill ratio (FGFR) (defined as the proportion of the volume of the fracture gap that is considered occupied by the expanded polymer-filled balloon)?but not by modulus of elasticity assigned to the polymer;2) with FGFR = 100%, stiffness was comparable to that of the Ti-6Al-4V alloy VP construct model;and 3) stiffness was within the range of literature values for stiffness of constructs comprising simulated fractures in fresh cadaveric distal radii fixated using metal volar locking plate. These results suggest that the fixator may be an alternative modality to metal volar plating and, as such, deserves further evaluation.