期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Differentiation of focal liver lesions using three-dimensional ultrasonography: Retrospective and prospective studies 被引量:12
1
作者 Kazushi Numata Manabu Morimoto +4 位作者 Akito Nozaki Michio Ueda Masaaki Kondo Satoshi Morita Katsuaki Tanaka 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第17期2109-2119,共11页
AIM: To differentiate focal liver lesions based on enhancement patterns using three-dimensional ultrasonography (3D US) with perflubutane-based contrast agent.METHODS: Two hundred and eighty two patients with focal li... AIM: To differentiate focal liver lesions based on enhancement patterns using three-dimensional ultrasonography (3D US) with perflubutane-based contrast agent.METHODS: Two hundred and eighty two patients with focal liver lesions,including 168 hepatocellular carcinomas (HCCs),63 metastases,40 hemangiomas and 11 focal nodular hyperplasias (FNHs),were examined by 3D US with perflubutane-based contrast agent.Tomographic ultrasound images and sonographic angiograms were reconstructed.Among 282 lesions,enhancement patterns of 163 lesions between January 2007 and October 2007 were analyzed retrospectively.Then from November 2007 to May 2008,compared with contrast-enhanced (CE) 2D US,CE 3D US was performed on 119 lesions for prospective differential diagnosis.Sensitivity,specificity,area under receiver operating characteristic curve (Az) and inter-reader agreement were assessed.RESULTS: With the tridimensional view,dominant enhancement patterns were revealed as diffuse enhancement or peripheral ring-like enhancement,followed with washout change for HCCs or metastases,respectively,and peripheral nodular enhancement or diffuse enhancement with spoke-wheel arteries,followed by persistent enhancement for hemangiomas or FNHs,respectively.At CE 3D US,the prospective differentiation of lesions showed sensitivity 92% (mean for two readers),specificity 91% and Az value 0.95 for HCCs,84%,97%,and 0.95 for metastases,91%,98%,and 0.98 for hemangiomas and 80%,99%,and 0.99 for FNHs,respectively,while good to excellent inter-reader agreement was achieved.No significant difference exists between prospective diagnosis accuracy at CE 3D US and that at CE 2D US.CONCLUSION: CE 3D US provides a spatial perspective for liver tumor enhancement,and could help in differentiating focal liver lesions. 展开更多
关键词 three-dimensional ultrasonography Contrast agent LIVER NEOPLASMS
下载PDF
Prenatal assessment of normal fetal pulmonary grey-scale and lung volume by three-dimensional ultrasonography 被引量:1
2
作者 Zhen Han,Xiao-Ye Zheng,Hong-Wei Yan,Wen-Li Gou Department of Obstetrics and Gynecology,the First Affiliated Hospital,Medical School of Xi’an Jiaotong University,Xi’an 710061,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期270-272,共3页
Objective To quantitatively analyze the fetal lung echo and right lung volume in the third trimester by real-time three-dimensional ultrasound(3-D US)and evaluate the feasibility of fetal lung maturity.Methods A total... Objective To quantitatively analyze the fetal lung echo and right lung volume in the third trimester by real-time three-dimensional ultrasound(3-D US)and evaluate the feasibility of fetal lung maturity.Methods A total of 732 women with normal singleton pregnancies between 28 and 42 weeks of gestation underwent ultrasound examination.The 3-D US equipment with a 3.5-5 MHz transabdominal transducer was used for the fetal biometric measurement.The echogenicity ratio between fetal lung and liver was compared.The fetal lung volume was calculated by the rotational multiplanar technique for volume measurement(VOCAL).Results The right fetal lung volume increased with the increase of gestational age with a linear positive correlation(r=0.884,P<0.01).After 34 weeks,the echogenicity ratio of fetal lung to liver was more than 1.1.Conclusion The echogenicity of lung/liver and fetal lung volume could be used as normal fetal predictable indicators for fetal lung maturity. 展开更多
关键词 fetal lung lung maturity SONOGRAM three-dimensional ultrasonography
下载PDF
Prenatal diagnosis of isolated lateral facial cleft by ultrasonography and three-dimensional printing:A case report 被引量:1
3
作者 Wen-Ling Song Hai-Ou Ma +5 位作者 Yu Nan Yu-Jia Li Na Qi Li-Ying Zhang Xin Xu Yuan-Yi Wang 《World Journal of Clinical Cases》 SCIE 2021年第24期7196-7204,共9页
BACKGROUND Lateral facial clefts are atypical with a low incidence in the facial cleft spectrum.With the development of ultrasonography(US)prenatal screening,such facial malformations can be detected and diagnosed pre... BACKGROUND Lateral facial clefts are atypical with a low incidence in the facial cleft spectrum.With the development of ultrasonography(US)prenatal screening,such facial malformations can be detected and diagnosed prenatally rather than at birth.Although three-dimensional US(3DUS)can render the fetus'face via 3D reconstruction,the 3D images are displayed on two-dimensional screens without field depth,which impedes the understanding of untrained individuals.In contrast,a 3D-printed model of the fetus'face helps both parents and doctors develop a more comprehensive understanding of the facial malformation by creating more interactive aspects.Herein,we present an isolated lateral facial cleft case that was diagnosed via US combined with a 3D-printed model.CASE SUMMARY A 31-year-old G2P1 patient presented for routine prenatal screening at the 22nd wk of gestation.The coronal nostril-lip section of two-dimensional US(2DUS)demonstrated that the fetus'bilateral oral commissures were asymmetrical,and left oral commissure was abnormally wide.The left oblique-coronal section showed a cleft at the left oral commissure which extended to the left cheek.The results of 3DUS confirmed the cleft.Furthermore,we created a model of the fetal face using 3D printing technology,which clearly presented facial malformations.The fetus was diagnosed with a left lateral facial cleft,which was categorized as a No.7 facial cleft according to the Tessier facial cleft classification.The parents terminated the pregnancy at the 24th wk of gestation after parental counseling.CONCLUSION In the diagnostic course of the current case,in addition to the traditional application of 2D and 3DUS,we created a 3D-printed model of the fetus,which enhanced diagnostic evidence,benefited the education of junior doctors,improved parental counseling,and had the potential to guide surgical planning. 展开更多
关键词 Prenatal diagnosis Isolated lateral facial cleft three-dimensional printing Facial malformations ultrasonography Tessier No.7 facial cleft Case report
下载PDF
Clinical Application of Surface Mode on Three-dimensional Ultrasonography: A Preliminary Study
4
作者 徐辉雄 张青萍 +2 位作者 周玉清 乐桂蓉 汪元芳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2000年第2期159-162,共4页
To investigate the methodology and evaluate the clinical value of surface mode on three- dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipmen... To investigate the methodology and evaluate the clinical value of surface mode on three- dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipment used here was Voluson 530D 3DUS imaging system and 3D volume trahsducer with frequency being 3. 0-5. 0 MHz. The 3DUS rendering method was surface mode. The results showed that: 1 ) Surface mode of 3DUS could demonstrate clearly the anatomical characteristics of the region-of-interest (ROI) and the inner wall of lesions or organs that contained fluid. The anatomic details, such as location, size, shape, and number of the ROI, could be visualized intuitively; 2) The outer anatomic features (e. g. contour, edge, configuration, etc. ) of some organs or lesions surrounded by fluid could be displayed clearly. It could be concluded that surface mode on 3DUS could provide more diagnostic information than two-dimensional ultrasonography (2DUS) in some cases and could served as a beneficial supplement to ZDUS in clinical practice. 展开更多
关键词 three-dimensional ultrasonography surface mode volume transducer
下载PDF
Trends in dentomaxillofacial radiology
5
作者 KıvançKamburoğlu 《World Journal of Radiology》 2025年第1期19-31,共13页
Oral and maxillofacial diagnostic imaging is of paramount importance in dental clinical diagnosis,treatment planning,and follow-up procedures.Periapical ra-diographic examination and numerous panoramic systems are use... Oral and maxillofacial diagnostic imaging is of paramount importance in dental clinical diagnosis,treatment planning,and follow-up procedures.Periapical ra-diographic examination and numerous panoramic systems are used in routine clinical dental practice.Cone beam CT is widely used and currently the method of choice in oral and maxillofacial implantology,endodontics,maxillofacial surgery,periodontics,degenerative temporomandibular joint disease,orthodontics,airway studies,sleep disorders,and forensic dentistry.Another innovative laboratory re-search tool that offers three-dimensional(3D)detailed high-resolution images of in vitro teeth and neighboring structures with submicrometric accuracy is micro-computed tomography.Ultra-high radiation doses,long scanning times,and high costs preclude its routine clinical use.In response to the high demand for a te-chnique that could provide real-time images using a cost-effective,rapid,user-friendly,and portable technique without ionizing radiation,some authors pro-posed ultrasound imaging methods as an alternative to X-ray imaging techniques.Ultrasonography can be used in the dentomaxillofacial region for various diagno-stic purposes such as salivary gland and superficial tissue examination.Recently,dedicated dental magnetic resonance imaging with appropriate software,hard-ware,sequences,and field of view tailored to fit dentomaxillofacial anatomy was introduced.Lately,3D printing technologies and their application in dentistry has attracted attention.During 3D printing a given material is added in successive layers to create a 3D object.The application of this technology has the potential to decrease operation time and minimize operator bias and the possibility of proce-dural errors.Another hot topic regarding dentomaxillofacial radiology is artificial intelligence,which is a field related to computer science dedicated to developing systems or machines that can perform tasks traditionally associated with human intelligence.It is obvious that further investigation and research in the field of dentomaxillofacial radiology will make great contributions to diagnostic imaging for various dental specialties. 展开更多
关键词 Dentomaxillofacial radiology Diagnostic imaging Cone beam CT ultrasonography Microcomputed tomography Dental microcomputed tomography three-dimensional printing Artificial intelligence
下载PDF
Endoanal ultrasonography in fecal incontinence: Current and future perspectives 被引量:5
6
作者 Andreia Albuquerque 《World Journal of Gastrointestinal Endoscopy》 2015年第6期575-581,共7页
Fecal incontinence has a profound impact in a patient's life, impairing quality of life and carrying a substantial economic burden due to health costs. It is an underdiagnosed condition because many affected patie... Fecal incontinence has a profound impact in a patient's life, impairing quality of life and carrying a substantial economic burden due to health costs. It is an underdiagnosed condition because many affected patients are reluctant to report it and also clinicians are usually not alert to it. Patient evaluation with a detailed clinical history and examination is very important to indicate the type of injury that is present. Endoanal ultrasonography is currently the gold standard for sphincter evaluation in fecal incontinence and is a simple, well-tolerated and non-expensive technique. Most studies revealed 100%sensitivity in identifying sphincter defect. It is better than endoanal magnetic resonance imaging for internal anal sphincter defects, equivalent for the diagnosis of external anal sphincter defects, but with a lower capacity for assessment of atrophy of this sphincter.The most common cause of fecal incontinence is anal sphincter injury related to obstetric trauma. Only a small percentage of women are diagnosed with sphincter tears immediately after vaginal delivery, but endoanal ultrasonography shows that one third of these women have occult sphincter defects. Furthermore, in patients submitted to primary repair of these tears, ultrasound revealed a high frequency of persistent sphincter defects after surgery. Three-dimensional endoanal ultrasonography is currently largely used and accepted for sphincter evaluation in fecal incontinence, improving diagnostic accuracy and our knowledge of physiologic and pathological sphincters alterations. Conversely,there is currently no evidence to support the use of elastography in fecal incontinence evaluation. 展开更多
关键词 Endoanal ultrasonography Fecal incontinence External anal sphincter Internal anal sphincter Obstetric anal sphincter injuries three-dimensional endoanal ultrasonography ELASTOGRAPHY
下载PDF
TACC diagnosed by transoesophageal endoscopic ultrasonography:A case report
7
作者 Xiao-Xin Pu Qin-Wei Xu Bao-Yi Liu 《World Journal of Clinical Cases》 SCIE 2023年第16期3847-3851,共5页
BACKGROUND Primary adenoid cystic carcinoma in the trachea(TACC)is a rare tumour.Tracheal bronchoscopy is always chosen as a routine approach to obtain a pathological diagnosis,but it can be associated with an increas... BACKGROUND Primary adenoid cystic carcinoma in the trachea(TACC)is a rare tumour.Tracheal bronchoscopy is always chosen as a routine approach to obtain a pathological diagnosis,but it can be associated with an increased risk of asphyxia.CASE SUMMARY We describe a case of TACC in a patient evaluated by chest computed tomography(CT)with three-dimensional reconstruction imaging and diagnosed by transoesophageal endoscopic ultrasonography.The pathological diagnosis confirmed tracheal adenoid cystic carcinoma.CONCLUSION We highlight the importance of CT and provide a successful exploration of transoesophageal biopsy as a safe alternative approach. 展开更多
关键词 Adenoid cystic carcinoma Tracheal obstruction Transoesophageal endoscopic ultrasonography three-dimensional computed tomography reconstruction Case report
下载PDF
Contrast enhanced ultrasound of hepatocellular carcinoma 被引量:16
8
作者 Kazushi Numata Manabu Morimoto +4 位作者 Masaaki Kondo Yosuke Kunishi Tomohiko Sasaki Akito Nozaki Katsuaki Tanaka 《World Journal of Radiology》 CAS 2010年第2期68-82,共15页
Sonazoid(Daiichi Sankyo,Tokyo,Japan),a secondgeneration of a lipid-stabilized suspension of a perfluorobutane gas microbubble contrast agent,has been used clinically in patients with liver tumors and for harmonic gray... Sonazoid(Daiichi Sankyo,Tokyo,Japan),a secondgeneration of a lipid-stabilized suspension of a perfluorobutane gas microbubble contrast agent,has been used clinically in patients with liver tumors and for harmonic gray-scale ultrasonography(US)in Japan since January 2007.Sonazoid-enhanced US has two phases of contrast enhancement:vascular and late.In the late phase of Sonazoid-enhanced US,we scanned the whole liver using this modality at a low mechanical index(MI)without destroying the microbubbles, and this method allows detection of small viable hepatocellular carcinoma(HCC)lesions which cannot be detected by conventional US as perfusion defects in the late phase.Re-injection of Sonazoid into an HCC lesion which previously showed a perfusion defect in the late phase is useful for confirming blood flow intothe defects.High MI intermittent imaging at 2 frames per second in the late phase is also helpful in differentiation between necrosis and viable hypervascular HCC lesions.Sonazoid-enhanced US by the coded harmonic angio mode at a high MI not only allows clear observation of tumor vessels and tumor enhancement, but also permits automatic scanning with Sonazoidenhanced three dimensional(3D)US.Fusion images combining US with contrast-enhanced CT or contrastenhanced MRI have made it easy to detect typical or atypical HCC lesions.By these methods,Sonazoidenhanced US can characterize liver tumors,grade HCC lesions histologically,recognize HCC dedifferentiation, evaluate the efficacy of ablation therapy or transcatheter arterial embolization,and guide ablation therapy for unresectable HCC.This article reviews the current developments and applications of Sonazoid-enhanced US and Sonazoid-enhanced 3D US for diagnosing and treating hepatic lesions,especially HCC. 展开更多
关键词 SONAZOID CONTRAST-ENHANCED ultrasonography CONTRAST-ENHANCED three-dimensional ultrasonography HEPATIC tumor HEPATOCELLULAR CARCINOMA Fusion image
下载PDF
Training benefits of virtual bronchoscopy prior to Endobronchial Ultrasound Guide sheath
9
作者 D. Fielding F. Bashirzadeh P. Nguyen 《Open Journal of Clinical Diagnostics》 2011年第3期9-14,共6页
Research questions. How does a virtual bronchoscopy navigation system (VBNS) improve prediction of candidate bronchus across a range of doctors investigating a range of lesions with Endobronchial ultrasound (EBUS) gui... Research questions. How does a virtual bronchoscopy navigation system (VBNS) improve prediction of candidate bronchus across a range of doctors investigating a range of lesions with Endobronchial ultrasound (EBUS) guide sheath? To what extent do benefits of virtual bronchoscopic pre-procedure navigation apply to experienced versus inexperienced bron- choscopists? Methods: Using archived EBUS Guide sheath cases, a comparison was made between identified candidate 4th order bronchus by Computerised tomography (CT) evaluation versus that identified after virtual path creation. Results: From 7 archived cases, 14 doctors identified the correct bronchus in 94 of 98 assessments (95%). Percentage of cases where there was an improvement in localisation by 2 or more 4th order bronchi was 39.8% overall (28.6% – 51.0%), 26.6 for experienced and 53.1 for inexperienced bronchoscopists (p < 0.02). The absolute mean number of 4th order bronchi different between CT and VBNS was 2.0 ± 2.6 overall, 1.2 (range 0-6) for experienced, and 2.8 (range 0-11) for inexperienced bronchoscopists. Virtual Path software calculation time was 8.1 ± 2.7 minutes, compared to 3.6 ± 2.1 minutes by CT. Conclusion: VBNS allowed rapid accurate assessment with minimal software training. Greatest benefits in reduction of procedure time were obtained in inexperienced bronchoscopists, and VBNS could allow more rapid skill development in EBUS GS in these doctors. 展开更多
关键词 Virtual BRONCHOSCOPY Lung Neoplasms and SOLITARY Pulmonary Nodule/Diagnosis Transbronchial Biopsy three-dimensional Imaging ENDOBRONCHIAL ultrasonography
下载PDF
Prenatal Diagnosis of Proximal Femoral Focal Deficiency Combining Ultrasound and Computer Tomography
10
作者 Erica Stein Ciasca Fernando Maia Peixoto-Filho +3 位作者 Pedro Daltro Heron Werner Adriana Viana Renato Augusto Moreira de Sá 《Advances in Computed Tomography》 2013年第3期102-106,共5页
Four cases of proximal femoral focal deficiency (PFFD) in an otherwise healthy infant are described. Antenatal diagnosis was made at 27, 23, 23 and 18 weeks of gestation by routine ultrasound (US) examination. Compute... Four cases of proximal femoral focal deficiency (PFFD) in an otherwise healthy infant are described. Antenatal diagnosis was made at 27, 23, 23 and 18 weeks of gestation by routine ultrasound (US) examination. Computer Tomography (CT) was performed after 30 weeks of gestation and confirmed the images obtained by US. The diagnosis was confirmed after delivery. These cases illustrate the importance of combining US and CT to improve accuracy of prenatal diagnosis of skeletal disorders. 展开更多
关键词 PRENATAL Diagnosis ultrasonography Imaging three-dimensional Tomography X-Ray Computed Limb DEFORMITIES CONGENITAL
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部