Dose rates calculations, in PMMA dosimeters, placed in the vicinity of the Tunisian 60Co gamma ray irradiator, have been achieved using a pencil like model. The obtained results are in good agreement with recent exper...Dose rates calculations, in PMMA dosimeters, placed in the vicinity of the Tunisian 60Co gamma ray irradiator, have been achieved using a pencil like model. The obtained results are in good agreement with recent experimental data. Moreover, in this work we determine also the conversion factor between the dose rate deposited in a PMMA dosimeter and the one deposited in a reel medium. This factor is used to determine the dose deposited in a real irradiated medium such as foodstuff products.展开更多
Introduction: To compare the measured dose distributions to calculated ones in dose-to-water (Dw) and dose-to-medium (Dm) reporting modes for simple plans and patient-specific intensity modulated radiation therapy (IM...Introduction: To compare the measured dose distributions to calculated ones in dose-to-water (Dw) and dose-to-medium (Dm) reporting modes for simple plans and patient-specific intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans using ArcCHECK with a fixed phantom density. Methods: The recommended density value of 1.18 g/cm3 for Acuros XB and X-ray voxel Monte Carlo was assigned to ArcCHECK on CT images. A total of 45 simple plans, including a 1-field plan, a 3-field plan, a 4-field plan, a half-arc plan from 270° to 90°, and a full-arc plan, were assessed. Subsequently, the patient-specific 96 IMRT and VMAT plans were evaluated. Gamma analysis with a 3% normalized global dose error and a 3 mm distance-to-agreement criteria (γ3%G/3mm) was performed in the Dw and Dm. The change in γ3%G/3mm between Dw and Dm were statistically analyzed using JMPPro11 software. Results: The median values of γ3%G/3mm for all simple plans for Dw and Dm were 98.1% (range, 75.2% - 100%) and 95.5% (range, 23.7% - 100%), respectively (p 0.01). In the patient-specific IMRT and VMAT plans, the median values of γ3%G/3mm for Dw and Dm were 98.6% (range, 90.1% - 100%) and 90.5% (range, 38.5% - 97.2%), respectively (p 0.01). Conclusion: Our results showed that the calculated and measured dose distributions were in good agreement for Dw, but were not for Dm. From the viewpoint of the rationale of dosimetry, Dw shows better agreement with measured dose distribution when using the fixedphantom density recommended by the vendor.展开更多
The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are inv...The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are investigated in this paper. Gamma ray and 10-MeV proton irradiation are selected for a detailed evaluation and comparison. Based on the measurement results induced by the gamma ray with various dose rates, the devices exhibit enhanced low dose rate sensitivity (ELDRS) under zero and working bias conditions. Meanwhile, it is obvious that the ELDRS is more severe under the working bias condition than under the zero bias condition. The degradation of AD9058 does not display obvious ELDRS during 10-MeV proton irradiation with the selected flux.展开更多
A 10 y (1999-2008) birth records from two public and most accessible maternity hospitals locally in the city of Abeokuta, Nigeria were used to investigate the possible association of high outdoor gamma radiation expos...A 10 y (1999-2008) birth records from two public and most accessible maternity hospitals locally in the city of Abeokuta, Nigeria were used to investigate the possible association of high outdoor gamma radiation exposure on reproductive abnormalities in the city. From the delivery record of 11,923 births in the period under study, a total number of 485 incidences of reproductive abnormalities were recoded. These incidences comprise 228 multiple births, 190 still births and, 67 premature births. Using the available terrestrial gamma radiation exposure data for the city and different reproductive abnormalities, regression assessment was carried out using the Pearson Product Moment (PPM) correlation statistics. The correlation showed that the incidences of reproductive abnormalities and the radiation dose levels were negatively correlated and correlation coefficient values were very low for each of the reproductive abnormalities considered. Factors such as socio-economic potentials of patients, dietary and other environmental factors may have substantial influence on the reproductive defects in the area other than radiation. However, the present study has added to the radiometric information needed in understanding the relationship between natural outdoor radiation exposure and occurrences of reproductive abnormalities in areas of high radiation in the country.展开更多
This study aims to determine the activity concentrations of naturally occurring, technically-enhanced levels of radiation and the gamma absorbed dose rates in soil samples collected across the land scape of historical...This study aims to determine the activity concentrations of naturally occurring, technically-enhanced levels of radiation and the gamma absorbed dose rates in soil samples collected across the land scape of historical area which discovered in east of Saudi Arabia at 2009 G, Called AL- RAKKAH. By using an HPGe detector gamma-ray spectrometer, the activity concentrations of 226Ra 232Th and 40K were found in surface soil samples ranged from 17. 4 ± 1.2 Bq/kg to 28.3 ± 2.3 Bq/kg with an average value of 23 ± 1.6 Bq/kg, ranging from 1.1 ± 1.8 Bq/kg to 81.0 ± 1.7 Bq/kg with the average value 20 ± 1.4 Bq/kg and from 218 ± 11 Bq/kg to 255 ± 18 Bq/kg, with the mean value of 233 ± 12 Bq/kg respectively. The mean radium equivalent (Raeq) and outdoor radiation hazard index (Hex) for the area under study were determined as 69.52 Bq/kg and 0.16 respectively. The total absorbed dose rate due to three primordial radionuclides lies in the range of 17.74 - 72.24 nGy·h-1 with a mean of 32.69 nGy·h-1, which yields total annual effective dose of 0.37 mSv·y-1. The measured values are comparable with other global radioactivity measurements and are found to be safe for public and environment. The baseline data of this type will almost certainly be of importance in making estimations of population exposure.展开更多
The CMOS (Complementary Metal Oxide Semiconductor) image sensor of a smartphone has been known for its sensitivity to gamma-rays. In this research, some smartphones were selected and tested for measurement of gamma-ra...The CMOS (Complementary Metal Oxide Semiconductor) image sensor of a smartphone has been known for its sensitivity to gamma-rays. In this research, some smartphones were selected and tested for measurement of gamma-rays emitted from Cesium-137 and Iridium-192 sources. During measurements, the phones were set in video mode while the camera lenses were covered with black adhesive tape to prevent light exposure. Interaction of gamma-rays with the CMOS appeared as flashing bright spots on the image. The bright spots were then counted by using the freely available ImageJ software. Preliminary results indicated that the number of bright spots increased linearly with increase of gamma-ray dose rate. An in-house Android application software was then developed for real-time counting of the bright spots. The application software also allowed users to input a calibration equation so that the phones could simultaneously convert the count rate to display in dose rate. This research demonstrated that, after appropriate calibration, smartphones could be used as gamma-ray measuring devices for radiation safety control involving high activity sources such as in industrial radiography, gamma-ray irradiation facility and medical treatment.展开更多
Monitoring results of gamma dose rate level in 1992~2004 in the ambient environment of the Qinshan Nuclear Power Plants(QNPP)Base,the northeast of Zhejiang Province,are reported in this paper.It is shown that the gam...Monitoring results of gamma dose rate level in 1992~2004 in the ambient environment of the Qinshan Nuclear Power Plants(QNPP)Base,the northeast of Zhejiang Province,are reported in this paper.It is shown that the gamma dose rate of five monitoring sites of 2.5 km to QNPP Base is 84~113 nGy/h,with an average of 96 nGy/h in the 13 years.The average value is close to the background level of 93 nGy/h prior to operation of the QNPP Base,and is lower than the monitoring result of 101 nGy/h at the reference site in Hangzhou City.Within 50 km from the QNPP Base,the cumulative dose rate of the thermoluminescent dosimeter(TLD)is 90 nGy/h,which is lower than the back- ground level of 111 nGy/h.展开更多
Micro-tubers are important propagules in potato breeding and potato production, and they are also dormant and easily transported and therefore good targets for mutation induction in potato mutation breeding. A prerequ...Micro-tubers are important propagules in potato breeding and potato production, and they are also dormant and easily transported and therefore good targets for mutation induction in potato mutation breeding. A prerequisite for mutation breeding is to determine optimal mutation treatments. Therefore, radio-sensitivity tests of a tetraploid and a diploid potato to gamma irradiation were undertaken. Effects of different gamma sources on radio-activity were also studied. In vitro potato cuttings were gamma irradiated using a wide dose range (0, 3, 6, 9, 12, 15 and 20 Gy). The irradiated cuttings were then cultured to induce micro-tubers directly in vitro. Micro-tuber morphotypes were assessed after irradiation of cuttings using three gamma sources with emission activities of 1.8, 7.07 and 139 Gy/min. The diploid species (Solanum verrucosum) was more radio-sensitive than the tetraploid cultivar Desirée (Solanum tuberosum). Gamma dose rates had significant influences on subsequent micro-tuber production at various mutant generations. Effects included reductions in the number, size and weight of micro-tubers produced. Gamma dose was more lethal for the diploid potato genotype and micro-tubers produced were small compared to those produced by the tetraploid genotype after irradiation. Different treatments are recommended for diploid and tetraploid potato irradiation in producing large mutant micro-tuber populations. The mutant micro-tuber populations may then be screened for interesting mutations/trait for both genetics and plant breeding purposes.展开更多
文摘Dose rates calculations, in PMMA dosimeters, placed in the vicinity of the Tunisian 60Co gamma ray irradiator, have been achieved using a pencil like model. The obtained results are in good agreement with recent experimental data. Moreover, in this work we determine also the conversion factor between the dose rate deposited in a PMMA dosimeter and the one deposited in a reel medium. This factor is used to determine the dose deposited in a real irradiated medium such as foodstuff products.
文摘Introduction: To compare the measured dose distributions to calculated ones in dose-to-water (Dw) and dose-to-medium (Dm) reporting modes for simple plans and patient-specific intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans using ArcCHECK with a fixed phantom density. Methods: The recommended density value of 1.18 g/cm3 for Acuros XB and X-ray voxel Monte Carlo was assigned to ArcCHECK on CT images. A total of 45 simple plans, including a 1-field plan, a 3-field plan, a 4-field plan, a half-arc plan from 270° to 90°, and a full-arc plan, were assessed. Subsequently, the patient-specific 96 IMRT and VMAT plans were evaluated. Gamma analysis with a 3% normalized global dose error and a 3 mm distance-to-agreement criteria (γ3%G/3mm) was performed in the Dw and Dm. The change in γ3%G/3mm between Dw and Dm were statistically analyzed using JMPPro11 software. Results: The median values of γ3%G/3mm for all simple plans for Dw and Dm were 98.1% (range, 75.2% - 100%) and 95.5% (range, 23.7% - 100%), respectively (p 0.01). In the patient-specific IMRT and VMAT plans, the median values of γ3%G/3mm for Dw and Dm were 98.6% (range, 90.1% - 100%) and 90.5% (range, 38.5% - 97.2%), respectively (p 0.01). Conclusion: Our results showed that the calculated and measured dose distributions were in good agreement for Dw, but were not for Dm. From the viewpoint of the rationale of dosimetry, Dw shows better agreement with measured dose distribution when using the fixedphantom density recommended by the vendor.
基金supported by the National Natural Science Foundation of China (Grant No. 11205038)the China Postdoctoral Science Foundation (Grant No. 2012M510951)
文摘The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are investigated in this paper. Gamma ray and 10-MeV proton irradiation are selected for a detailed evaluation and comparison. Based on the measurement results induced by the gamma ray with various dose rates, the devices exhibit enhanced low dose rate sensitivity (ELDRS) under zero and working bias conditions. Meanwhile, it is obvious that the ELDRS is more severe under the working bias condition than under the zero bias condition. The degradation of AD9058 does not display obvious ELDRS during 10-MeV proton irradiation with the selected flux.
文摘A 10 y (1999-2008) birth records from two public and most accessible maternity hospitals locally in the city of Abeokuta, Nigeria were used to investigate the possible association of high outdoor gamma radiation exposure on reproductive abnormalities in the city. From the delivery record of 11,923 births in the period under study, a total number of 485 incidences of reproductive abnormalities were recoded. These incidences comprise 228 multiple births, 190 still births and, 67 premature births. Using the available terrestrial gamma radiation exposure data for the city and different reproductive abnormalities, regression assessment was carried out using the Pearson Product Moment (PPM) correlation statistics. The correlation showed that the incidences of reproductive abnormalities and the radiation dose levels were negatively correlated and correlation coefficient values were very low for each of the reproductive abnormalities considered. Factors such as socio-economic potentials of patients, dietary and other environmental factors may have substantial influence on the reproductive defects in the area other than radiation. However, the present study has added to the radiometric information needed in understanding the relationship between natural outdoor radiation exposure and occurrences of reproductive abnormalities in areas of high radiation in the country.
文摘This study aims to determine the activity concentrations of naturally occurring, technically-enhanced levels of radiation and the gamma absorbed dose rates in soil samples collected across the land scape of historical area which discovered in east of Saudi Arabia at 2009 G, Called AL- RAKKAH. By using an HPGe detector gamma-ray spectrometer, the activity concentrations of 226Ra 232Th and 40K were found in surface soil samples ranged from 17. 4 ± 1.2 Bq/kg to 28.3 ± 2.3 Bq/kg with an average value of 23 ± 1.6 Bq/kg, ranging from 1.1 ± 1.8 Bq/kg to 81.0 ± 1.7 Bq/kg with the average value 20 ± 1.4 Bq/kg and from 218 ± 11 Bq/kg to 255 ± 18 Bq/kg, with the mean value of 233 ± 12 Bq/kg respectively. The mean radium equivalent (Raeq) and outdoor radiation hazard index (Hex) for the area under study were determined as 69.52 Bq/kg and 0.16 respectively. The total absorbed dose rate due to three primordial radionuclides lies in the range of 17.74 - 72.24 nGy·h-1 with a mean of 32.69 nGy·h-1, which yields total annual effective dose of 0.37 mSv·y-1. The measured values are comparable with other global radioactivity measurements and are found to be safe for public and environment. The baseline data of this type will almost certainly be of importance in making estimations of population exposure.
文摘The CMOS (Complementary Metal Oxide Semiconductor) image sensor of a smartphone has been known for its sensitivity to gamma-rays. In this research, some smartphones were selected and tested for measurement of gamma-rays emitted from Cesium-137 and Iridium-192 sources. During measurements, the phones were set in video mode while the camera lenses were covered with black adhesive tape to prevent light exposure. Interaction of gamma-rays with the CMOS appeared as flashing bright spots on the image. The bright spots were then counted by using the freely available ImageJ software. Preliminary results indicated that the number of bright spots increased linearly with increase of gamma-ray dose rate. An in-house Android application software was then developed for real-time counting of the bright spots. The application software also allowed users to input a calibration equation so that the phones could simultaneously convert the count rate to display in dose rate. This research demonstrated that, after appropriate calibration, smartphones could be used as gamma-ray measuring devices for radiation safety control involving high activity sources such as in industrial radiography, gamma-ray irradiation facility and medical treatment.
文摘Monitoring results of gamma dose rate level in 1992~2004 in the ambient environment of the Qinshan Nuclear Power Plants(QNPP)Base,the northeast of Zhejiang Province,are reported in this paper.It is shown that the gamma dose rate of five monitoring sites of 2.5 km to QNPP Base is 84~113 nGy/h,with an average of 96 nGy/h in the 13 years.The average value is close to the background level of 93 nGy/h prior to operation of the QNPP Base,and is lower than the monitoring result of 101 nGy/h at the reference site in Hangzhou City.Within 50 km from the QNPP Base,the cumulative dose rate of the thermoluminescent dosimeter(TLD)is 90 nGy/h,which is lower than the back- ground level of 111 nGy/h.
文摘Micro-tubers are important propagules in potato breeding and potato production, and they are also dormant and easily transported and therefore good targets for mutation induction in potato mutation breeding. A prerequisite for mutation breeding is to determine optimal mutation treatments. Therefore, radio-sensitivity tests of a tetraploid and a diploid potato to gamma irradiation were undertaken. Effects of different gamma sources on radio-activity were also studied. In vitro potato cuttings were gamma irradiated using a wide dose range (0, 3, 6, 9, 12, 15 and 20 Gy). The irradiated cuttings were then cultured to induce micro-tubers directly in vitro. Micro-tuber morphotypes were assessed after irradiation of cuttings using three gamma sources with emission activities of 1.8, 7.07 and 139 Gy/min. The diploid species (Solanum verrucosum) was more radio-sensitive than the tetraploid cultivar Desirée (Solanum tuberosum). Gamma dose rates had significant influences on subsequent micro-tuber production at various mutant generations. Effects included reductions in the number, size and weight of micro-tubers produced. Gamma dose was more lethal for the diploid potato genotype and micro-tubers produced were small compared to those produced by the tetraploid genotype after irradiation. Different treatments are recommended for diploid and tetraploid potato irradiation in producing large mutant micro-tuber populations. The mutant micro-tuber populations may then be screened for interesting mutations/trait for both genetics and plant breeding purposes.