期刊文献+
共找到262篇文章
< 1 2 14 >
每页显示 20 50 100
Pyrolysis of Polytrimethylene Terephthalate(PTT) Fiber by Pyrolysis Gas Chromatography-Mass Spectroscopy
1
作者 钱和生 《Journal of Donghua University(English Edition)》 EI CAS 2007年第5期604-609,共6页
Pyrolysis of polytrimethylene terephthalate(PTT) fiber has been investigated by pyrolysis gas chromatography-mass spectroscopy in the temperature range from 400℃ to 750℃ in order to observe the possible effect of th... Pyrolysis of polytrimethylene terephthalate(PTT) fiber has been investigated by pyrolysis gas chromatography-mass spectroscopy in the temperature range from 400℃ to 750℃ in order to observe the possible effect of the temperature on its composition of pyrolysates.At 400℃,pyrolysis of molecular chain could occur,only 13 pyrolysates could be identified.The trimethylene moieties bound to the macromolecular core by ester bonds are cleaved at around 400℃.At 550℃-750℃,pyrolysis of molecular chain could completely take place,46 pyrolysates could be found.As the temperature increases,the compositions of pyrolysate are distinctly increased.Several compounds,especially benzoic acid,monopropenyl-p-phthalate,2-propenyl benzoate,di-2-propenyl ester,1,4-benzenedicarboxylic acid,benzene,1,5-hexadiene,biphenyl and 1,3-propanediol dibenzoate could be formed.The thermal degradation mechanism,which is determined by structure and amount of the thermal decomposition products,are described.During pyrolysis of polytrimethylene terephthalate,polymeric chain scissions take place a peeling reaction as a successive removal of the dimer units from the polymeric chain.The chain scissions are followed by the elimination reaction,linkage action and secondary reactions,which bring about a variety fragment. 展开更多
关键词 polytrimethylene terephthalate fiber PYROLYSIS thermal degradation gas chromatography mass spectroscopy
下载PDF
Rapid and real-time analysis of multi-component dissolved gas in seawater by Raman spectroscopy combined with continuous gas-liquid separator
2
作者 Dewang Yang Wenhua Li +5 位作者 Lei Guo Yuhang Ji Yanzhe Gong Junwei Chu Libin Du Yongmei Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第9期146-153,共8页
Rapid and sensitive detection of dissolved gases in seawater is quite essential for the investigation of the global carbon cycle.Large quantities of in situ optical detection techniques showed restricted measurement e... Rapid and sensitive detection of dissolved gases in seawater is quite essential for the investigation of the global carbon cycle.Large quantities of in situ optical detection techniques showed restricted measurement efficiency,owing to the single gas sensor without the identification ability of multiple gases.In this work,a novel gas-liquid Raman detection method of monitoring the multi-component dissolved gases was proposed based on a continuous gas-liquid separator under a large difference of partial pressure.The limit of detection(LOD)of the gas Raman spectrometer could arrive at about 14 μl·L^(-1)for N_(2)gas.Moreover,based on the continuous gas-liquid separation process,the detection time of the dissolved gases could be largely decreased to about 200 s compared with that of the traditional detection method(30 min).Effect of equilibrium time on gas-liquid separation process indicated that the extracted efficiency and decay time of these dissolved gases was CO_(2)>O_(2)>N_(2).In addition,the analysis of the relationship between equilibrium time and flow speed indicated that the decay time decreased with the increase of the flow speed.The validation and application of the developed system presented its great potential for studying the components and spatiotemporal distribution of dissolved gases in seawater. 展开更多
关键词 Dissolved gas Rapid quantitative analysis gas-liquid separator gas-liquid Raman spectroscopy
下载PDF
Super Antibiotics, Part II. Hyperforin, Mass Spectroscopy (MS) and Gas Chromatography-Mass Spectrometry (GC-MS), Evidence of Permeability of the Blood-Testis Barrier (BTB) and the Blood-Brain Barrier (BBB) to Hyperforin 被引量:2
3
作者 Ilia Brondz 《International Journal of Analytical Mass Spectrometry and Chromatography》 2016年第4期66-73,共8页
In the first article of this series, we presented some evidence of hyperforin as an antibiotic, antiprotozoal, antiviral, anticancer, and immunomodulatory substance. In the present article, evidence of the permeabilit... In the first article of this series, we presented some evidence of hyperforin as an antibiotic, antiprotozoal, antiviral, anticancer, and immunomodulatory substance. In the present article, evidence of the permeability of the blood-testis barrier (BTB) and blood-brain barrier (BBB) to hyperforin and its distribution in other organs of the domestic pig (Sus scrofa domesticus) are revealed. Seven-month-old male boars with a body mass of 100 kg were fed a diet containing hyperforin. Organs were surgically removed under anesthesia. Organs were suitable prepared and extracted, and then analyzed using gas chromatography-mass spectrometry with supersonic molecular beams (GC-MS with SMB). The presence of hyperforin was recorded in all organs and body fluids. Special attention was paid to the evaluation of the presence of hyperforin in the brain and testes of experimental animals. The presence of hyperforin in the brain and testes of experimental animals was established by GC-MS with SMB. The results are of interest because penicillin and numerous other antibiotics cannot pass through the BTB or BBB if healthy or non-inflamed, which limits their use in patients with meningitis and gonorrhea. The findings are also of interest in cases of penicillin- and multi-antibiotic-resistant bacterial infections. 展开更多
关键词 ANTIBIOTICS HYPERFORIN Super antibiotic Mass spectroscopy gas chromatography-mass Spectrometry Blood-Testis Barrier Blood-Brain Barrier Methicillin-Resistant Staphylococcus aureus (MRSA)
下载PDF
Determination of 14 Organophosphorus Pesticide Residues in Mutton by Gel Permeation Chromatography-Gas Chromatography-Mass Spectrometry(GPC-GC-MS)
4
作者 Junpeng ZHAO Richard Avoi +2 位作者 Azman Bin Atil@Azmi Jiao CHEN Ling YUN 《Agricultural Biotechnology》 2024年第3期28-30,33,共4页
[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga... [Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton. 展开更多
关键词 MUTTON gas chromatography-mass spectrometry Gel permeation chromatography ORGANOPHOSPHORUS Pesticide residue
下载PDF
Simultaneous Determination of 8 Pesticide Residues in Green Tea Based on Gas Chromatography-mass Spectrometry
5
作者 林真 陈健 +4 位作者 李捷 惠美星 蓝锦昌 江锦彬 杨方 《Agricultural Science & Technology》 CAS 2015年第11期2515-2518,2521,共5页
To improve pesticide residues detection efficiency in tea, simultaneous de- termination of eight pesticide residues in green tea was developed based on gas chromatography-mass spectrometry (GC-MS). The results showe... To improve pesticide residues detection efficiency in tea, simultaneous de- termination of eight pesticide residues in green tea was developed based on gas chromatography-mass spectrometry (GC-MS). The results showed that, - detected by the GC-MS under following conditions: acetonitrile as extraction and elution solvent, activated carbon and PSA tandem column as the stationary phase, elution volume of 12 ml the relationship between peak area and concentration of each residue (ametryn in the range of 0-100 pg/L, napropamide in the range of 0-10 000 gg/L, other pesticides in the range of 0-1 000 tJg/L) were linearly related, and their corre- lation coefficients were all greater than 0.999. The recovery rate the pesticides added to tea sample at legal concentration limits ranged from 73.6% to 116.8%, and the relative standard deviation from 1.47% to 15.58%. The new method we de- veloped is sensitive, specific and anti-interference, and thus provides test basis for the development of pesticide matrix reference materials in tea. 展开更多
关键词 TEA Pesticide residues gas chromatography-mass spectrometry
下载PDF
Simultaneous Determination of Hexoestrol, Diethylstilbestrol, Estrone and 17-Beta-estradiol in Feed by Gas Chromatography-mass Spectrometry 被引量:6
6
作者 Huo Feng Li Ning Lin Xiao-Li 《Journal of Northeast Agricultural University(English Edition)》 CAS 2016年第1期44-49,共6页
A method was developed for the simultaneous determination of four kinds of estrogens (hexoestrol, diethylstilbestrol, estrone, and 17-beta-estradiol) in feed by gas chromatography-mass spectrometry (GC-MS). After ... A method was developed for the simultaneous determination of four kinds of estrogens (hexoestrol, diethylstilbestrol, estrone, and 17-beta-estradiol) in feed by gas chromatography-mass spectrometry (GC-MS). After the sample was extracted by ethyl ether and cleaned-up on HLB phase extraction column, four kinds of estrogens were derived and quantified in gas chromatographymass spectrometry. The results showed that the linear detectable ranged from 2.5 ng· mL-1 to 250 ng· mL-1for hexoestrol and from 5 ng· mL-1 to 500 ng· mL-1 for three other estrogens with the correlation coefficients (R2) were no less than 0.990. The recoveries were in the range of 76.34%-96.33% and the relative standard deviation was no more than 22.7%. The limits of quantitation (LOQ) for all analytics were between 10 ug· kg^-1 and 20 ug· kg^-1. The method was accurate and sensitive and could meet the actual requirements for the analyses of feed samples. 展开更多
关键词 gas chromatography-mass spectrometry hexoestrol DIETHYLSTILBESTROL ESTRONE 17-beta-estradiol FEED
下载PDF
Analysis of volatile chemical components of Radix Paeoniae Rubra by gas chromatography-mass spectrometry and chemometric resolution 被引量:11
7
作者 李晓如 兰正刚 梁逸曾 《Journal of Central South University of Technology》 2007年第1期57-61,共5页
The volatile chemical components of Radix Paeoniae Rubra (RPR) were analyzed by gas chromatography-mass spectrometry with the method of heuristic evolving latent projections and overall volume integration. The results... The volatile chemical components of Radix Paeoniae Rubra (RPR) were analyzed by gas chromatography-mass spectrometry with the method of heuristic evolving latent projections and overall volume integration. The results show that 38 volatile chemical components of RPR are determined, accounting for 95.21% of total contents of volatile chemical components of RPR. The main volatile chemical components of RPR are (Z, Z)-9,12-octadecadienoic acid, n-hexadecanoic acid, 2-hydroxy- benzaldehyde, 1-(2-hydroxy-4-methoxyphenyl)-ethanone, 6,6-dimethyl-bicyclo[3.1.1] heptane-2-methanol, 4,7-dimethyl-benzofuran, 4-(1-methylethenyl)-1-cyclohexene-1-carboxaldehyde, and cyclohexadecane. 展开更多
关键词 Radix Paeoniae Rubra volatile chemical components gas chromatography-mass spectrometry heuristic evolving latent projections
下载PDF
Comparative analysis of essential oils found in Rhizomes Curcumae and Radix Curcumae by gas chromatography-mass spectrometry 被引量:5
8
作者 Di-Ya Lu Yan Cao +5 位作者 Ling Li Zhen-Yu Zhu Xin Dong Hai Zhang Yi-Feng Chai Zi-Yang Lou 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第3期203-207,共5页
A comparison of the volatile compounds in Rhizomes Curcumae (Ezhu) and Radix Curcumae (Yujin) was undertaken using gas chromatography mass spectrometi-y (GC-MS). Ultrasonic extraction and GC-MS methods were deve... A comparison of the volatile compounds in Rhizomes Curcumae (Ezhu) and Radix Curcumae (Yujin) was undertaken using gas chromatography mass spectrometi-y (GC-MS). Ultrasonic extraction and GC-MS methods were developed for the simultaneous determination of five sesquiterpenes, namely, α-pinene, β-elemene, curcumol, germacrone and curdione, in Ezhu and Yunjin. Good linearity (r〉0.999) and high inter-day precision were observed over the investigated concentration ranges. The validated method was successfully used for the simultaneous determination of five sesquiterpenes in Ezhu and Yujin. The quantitative method can be effectively used to evaluate and monitor the quality of Chinese curcuma in clinical use. 展开更多
关键词 gas chromatography-mass spectrometry Rhizomes Curcumae Radix Curcumae Volatile compounds Quality control
下载PDF
Rapid and simultaneous determination of ten off-flavor compounds in water by headspace solid phase microextraction and gas chromatography-mass spectrometry 被引量:3
9
作者 邹攀 王琳 +2 位作者 杨兆光 李小婉 李海普 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第1期59-67,共9页
A simple and sensitive analytical procedure for the determination of multi-component compounds in water samples was developed and optimized using the headspace solid-phase microextraction(HSSPME) coupled with gas chro... A simple and sensitive analytical procedure for the determination of multi-component compounds in water samples was developed and optimized using the headspace solid-phase microextraction(HSSPME) coupled with gas chromatography-mass spectrometry(GC-MS). Ten off-flavor compounds, including geosmin(GSM), 2-methylisoborneol(2-MIB), 2-isopropyl-3-methoxypyrazine(IPMP), 2-isobutyl-3-methoxypyrazine(IBMP), β-ionone, trans-2,cis-6-nonadienal(NDE), 2,3,4-trichloroanisole(2,3,4-TCA), 2,3,6-trichroloanisole(2,3,6-TCA), 2,4,6-trichloroanisole(2,4,6-TCA), and 2,4,6-tribromoanisole(2,4,6-TBA) were used as the target analytes. The optimization of extraction parameters including fibers types, extraction time, extraction temperature, stirring rate, sample volume, and ionic strength was carried out through the univariate approach. Ten off-flavor compounds were quantified within 50 min under the optimal conditions. Calibration curves with good linearity(r^2=0.990-0.998) were obtained in the range 1.0/2.0-100 ng/L, while the limits of detection for all compounds were lower than or close to the odor threshold concentration. Furthermore, the proposed method was applied to analyzing and determining the off-flavor compounds in real water samples from water-treatment plants. 展开更多
关键词 off-flavor compounds MICROEXTRACTION gas chromatography-mass spectrometry (GC-MS) water quality
下载PDF
Volatile components of Rhizoma Alpiniae Officinarum using three different extraction methods combined with gas chromatography-mass spectrometry 被引量:3
10
作者 Zhi-Sheng Xie Xin-Jun Xu +3 位作者 Chun-Yan Xie Jie-Yun Huang Mei Yang De-Po Yang 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第3期215-220,共6页
Volatile components from Rhizoma Alpiniae Officinarum were respectively extracted by three methods including hydrodistillation, headspace solid-phase microextraction (HS-SPME) and diethyl ether extraction. A total o... Volatile components from Rhizoma Alpiniae Officinarum were respectively extracted by three methods including hydrodistillation, headspace solid-phase microextraction (HS-SPME) and diethyl ether extraction. A total of 40 (hydrodistillation), 32 (HS-SPME) and 37 (diethyl ether extraction) compounds were respectively identified by gas chromatography-mass spectrometry (GC/MS) and 22 compounds were overlapped, including β-farnesene, 7-muurolene, 2,6-dimethyl-6- (4-methyl-3-pentenyl)bicyclo[3.1.1]hept-2-ene, eucalyptol and cadina-1(10), 4-diene and so forth, varying in relative contents. HS-SPME is fast, sample saving and solvent-free and it also can achieve similar profiles as those from hydrodistillation and solvent extraction. Therefore, it can be the priority for extracting volatile components from medicinal plants. 展开更多
关键词 Rhizoma AlpiniaeOfficinarum Volatile components HYDRODISTILLATION Headspace solid-phasemicroextraction Diethyl ether extraction gas chromatography-mass spectrometry
下载PDF
Experimental study on mercury content in flue gas of coal-fired units based on laser-induced breakdown spectroscopy 被引量:3
11
作者 Kai RONG Zhenzhen WANG +4 位作者 Ruomu HU Renwei LIU Yoshihiro DEGUCH Junjie YAN Jiping LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第7期75-82,共8页
Accurate measurement of trace heavy metal mercury(Hg) in flue gas of coal-fired units is great significance for ecological and environmental protection.Mixed gas was used to simulate the actual flue gas of a power pla... Accurate measurement of trace heavy metal mercury(Hg) in flue gas of coal-fired units is great significance for ecological and environmental protection.Mixed gas was used to simulate the actual flue gas of a power plant in this study.A laser-induced breakdown spectroscopy(LIBS)system for Hg measurement in mixed gas was built to study the effect of mixed gas pressure,Hg concentration in mixed gas and delay time on Hg measurement.The experimental results show that the appropriate low mixed gas pressure can obtain high Hg signal intensity and signal to noise ratio.The Hg signal intensity and signal to noise ratio increased with the increase of Hg concentration in mixed gas.The Hg signal intensity and signal to noise ratio decreased with the increase in delay time.According to the above results,the optimized measurement conditions can be determined.Different Hg concentrations in mixed gas were quantitatively analyzed by the internal standard method and traditional calibration method respectively.The relative error of prediction of the test sample obtained by the internal standard method was within 11.11%.The relative error of prediction of the traditional calibration method was less than 14.54%.This proved that the internal standard method can improve the accuracy of quantitative analysis of Hg concentration in flue gas using LIBS. 展开更多
关键词 laser-induced breakdown spectroscopy flue gas trace heavy metal quantitative analysis
下载PDF
Metabolomic Fingerprint of the Model Ciliate, Tetrahymena thermophila Determined by Untargeted Profiling Using Gas Chromatography-Mass Spectrometry 被引量:1
12
作者 XU Jing BO Tao +1 位作者 SONG Weibo WANG Wei 《Journal of Ocean University of China》 SCIE CAS CSCD 2019年第3期654-662,共9页
The ciliate Tetrahymena is a valuable model organism in the studies of ecotoxicology. Changes in intracellular metabolism are caused by exogenous chemicals in the environment. Intracellular metabolite changes signify ... The ciliate Tetrahymena is a valuable model organism in the studies of ecotoxicology. Changes in intracellular metabolism are caused by exogenous chemicals in the environment. Intracellular metabolite changes signify toxic effects and can be monitored by metabolomics analysis. In this work, a protocol for the GC-MS-based metabolomic analysis of Tetrahymena was established. Different extraction solvents showed divergent effects on the metabolomic analysis of Tetrahymena thermophila. The peak intensity of metabolites detected in the samples of extraction solvent Formula 1(F1) was the strongest and stable, while 61 metabolites were identified. Formula 1 showed an excellent extraction performance for carbohydrates. In the samples of extraction solvent Formula 2(F2), 66 metabolites were characterized, and fatty acid metabolites were extracted. Meanwhile, 57 and 58 metabolites were characterized in the extraction with Formula 3(F3) and Formula 4(F4), respectively. However, the peak intensity of the metabolites was low, and the metabolites were unstable. These results indicated that different extraction solvents substantially affected the detected coverage and peak intensity of intracellular metabolites. A total of 74 metabolites(19 amino acids, 11 organic acids, 2 inorganic acids, 11 fatty acids, 11 carbohydrates, 3 glycosides, 4 alcohols, 6 amines, and 7 other compounds) were identified in all experimental groups. Among these metabolites, amino acids, glycerol, myoinositol, and unsaturated fatty acids may become potential biomarkers of metabolite set enrichment analysis for detecting the ability of T. thermophila against environmental stresses. 展开更多
关键词 TETRAHYMENA THERMOPHILA metabolomics ECOTOXICOLOGY gas chromatography-mass spectrometry
下载PDF
Multiresidue Method for Determination of 67 Pesticides in Water Samples Using Solid-Phase Extraction with Centrifugation and Gas Chromatography-Mass Spectrometry 被引量:3
13
作者 Abir Kouzayha Abdul Rahman Rabaa +3 位作者 Mohamad Al Iskandarani Daniel Beh Hélène Budzinski Farouk Jaber 《American Journal of Analytical Chemistry》 2012年第3期257-265,共9页
A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 a... A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 and Oasis HLB. Parameters that influence the extraction efficiency such as the eluent volume, the sample loading volume, the addition of organic solvent to water sample, sorbent drying and elute concentration were optimized. The innovation of this work was the examination of the use of a centrifugation technique in both the drying and elution steps. When combined with centrifugation, the volume of the elution solvent was reduced to 2 mL and the time for sorbent drying decreased also to 10 min under vacuum. Under the optimized conditions, this method showed good recoveries higher than 65% - 68% for the 67 analyzed pesticides using the C18 and HLB cartridges with relative standard deviations lower than 9.7% - 12.3%. Limits of quantification were between 2 and 20 ng.L–1. The simplicity of the described method, use of less of organic solvent, short procedure time, and good recoveries demonstrate the advantages of this environmentally friendly approach for routine analysis of numerous samples. 展开更多
关键词 MULTI-RESIDUE PESTICIDES SOLID-PHASE Extraction CENTRIFUGATION gas chromatography-mass SPECTROMETRY
下载PDF
Quantitative analysis of trace levels of β-ionone in water by liquid-liquidphase extraction-gas chromatography-mass spectrometry(LLE-GC-MS) 被引量:1
14
作者 高梦鸿 高乃云 +3 位作者 谢茴茴 安娜 邓扬 戎文磊 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第2期472-477,共6页
A simple and rapid technique based on liquid-liquid extraction coupled to gas chromatography-mass spectrometric detection(LLE-GC-MS) was developed for analysis of taste and odour compound β-ionone in water. Instrumen... A simple and rapid technique based on liquid-liquid extraction coupled to gas chromatography-mass spectrometric detection(LLE-GC-MS) was developed for analysis of taste and odour compound β-ionone in water. Instrument parameters including programmed oven temperature, injection temperature and ion source temperature were evaluated and optimized. Effects of extraction time, ionic strength and p H on the detection efficiency were investigated and optimum conditions were 8 min of extraction time, without Na Cl addition at p H=9. Good linearity(R2=0.9997) was obtained when the linear range was 10-500 μg/L. The recoveries of β-ionone in ultrapure water and tap water samples were 88%-95% and 110%-114%, respectively. The relative standard deviations(RSD) were less than 10%. The method detection limit(MDL) and rejection quality level(RQL) were achieved at1.98 μg/L and 6.53 μg/L, respectively. LLE-GC-MS was demonstrated to be a rapid and convenient method for the determination ofβ-ionone in water samples. 展开更多
关键词 liquid-liquid extraction gas chromatography-mass spectrometry Β-IONONE WATER
下载PDF
Wide dynamic detection range of methane gas based on enhanced cavity absorption spectroscopy 被引量:2
15
作者 Yu Wang Bo-Kun Ding +4 位作者 Kun-Yang Wang Jiao-Xu Mei Ze-Lin Han Tu Tan Xiao-Ming Gao 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第4期244-248,共5页
Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have ... Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc. 展开更多
关键词 integrated cavity output spectroscopy(ICOS) trace gas wide dynamic detection absorption positions
下载PDF
Gel Permeation Chromatography Purification and Gas Chromatography-Mass Spectrometry Detection of Multi-Pesticide Residues in Traditional Chinese Medicine 被引量:2
16
作者 Wan-E Zhuang Zhen-Bin Gong 《American Journal of Analytical Chemistry》 2012年第1期24-32,共9页
The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas ... The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chroma- tography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractants from sample matrices which may have interfere to the qualitative and quantitative analysis, such as pigments, were removed using GPC purification. Simultaneous full scan and selective ion monitor (scan/SIM) mode for GC-MS was used for qualitative and quantitative analysis, which pro- vided retention time and characteristic fragments ratio for each pesticide so as to positively identify each analyte. Rela- tive standard deviations (RSDs) were within 7.7% (5.0 - 22.5 μg/kg, n = 3). The recoveries of pesticide standards at the spiked concentration of 5.0 - 22.5 μg/kg were between 87.1% and 110.9%. Limits of detection (LODs) for the analytes were 0.16 - 3.2 μg/kg, which could meet the demand of routine analysis and TCM quality control. 展开更多
关键词 Traditional Chinese Medicine Multi-Pesticide RESIDUE Flos Lonicerae Gel PERMEATION CHROMATOGRAPHY gas chromatography-mass SPECTROMETRY
下载PDF
Analysis of volatile components in a Chinese fish sauce,Fuzhou Yulu, by gas chromatography-mass spectrometry 被引量:1
17
作者 Yuan-fan YANG Shen-ru CHEN +1 位作者 Hui NI Xing-qian YE 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2008年第12期977-981,共5页
Volatile components of Fuzhou Yulu, a Chinese fish sauce, were analyzed by gas chromatography-mass spectrometry (GC-MS), and two pretreatment methods, i.e., purge and trap (P&T) GC-MS and ethyl acetate extraction... Volatile components of Fuzhou Yulu, a Chinese fish sauce, were analyzed by gas chromatography-mass spectrometry (GC-MS), and two pretreatment methods, i.e., purge and trap (P&T) GC-MS and ethyl acetate extraction followed by GC-MS, were compared. P&T-GC-MS method determined 12 components, including sulfur-containing constituents (such as dimethyl disulfide), nitrogen-containing constituents (such as pyrazine derivatives), aldehydes and ketones. Ethyl acetate extraction fol- lowed by GC-MS method detected 10 components, which were mainly volatile organic acids (such as benzenepropanoic acid) and esters. Neither of the two methods detected alcohols or trimethylamine. This study offers an important reference to determine volatile flavor components of traditional fish sauce through modem analysis methods. 展开更多
关键词 Fish sauce Fuzhou Yulu Volatile component Purge and trap gas chromatography-mass spectrometry (GC-MS)
下载PDF
Wavelength modulation spectroscopy for measurements of gas parameters in combustion field 被引量:1
18
作者 屈东胜 洪延姬 +1 位作者 王广宇 潘虎 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第6期178-186,共9页
A novel wavelength modulation spectroscopy sensor for studying gas properties near 1.4 μm is developed, validated and used in a direct-connect supersonic combustion test facility. In this sensor there are two H2O tra... A novel wavelength modulation spectroscopy sensor for studying gas properties near 1.4 μm is developed, validated and used in a direct-connect supersonic combustion test facility. In this sensor there are two H2O transitions near 7185.60 cm^-1 and 7454.45 cm^-1 that are used to enable the measurements along the line-of-sight. According to an iterative algorithm, the gas pressure, temperature and species mole fraction can be measured simultaneously. The new sensor is used in the isolator and extender of the supersonic combustion test facility. In the isolator, the sensor resolves the transient and measured pressure, temperature and H2O mole fraction with accuracies of 2.5%, 8.2%, and 7.2%, respectively. Due to the non-uniform characteristic in the extender, the measured results cannot precisely characterize gas properties, but they can qualitatively describe the distinctions of different zones or the changes or fluctuations of the gas parameters. 展开更多
关键词 wavelength modulation spectroscopy SENSOR gas properties iterative algorithm
下载PDF
Ultrasonic Nebulization Extraction Coupled with Gas Chromatography-Mass Spectrometry for Analysis of Volatile Components in Traditional Chinese Patent Medicine 被引量:1
19
作者 LIANG Yue WANG Lu WANG Zi-ming YU Cui ZHANG Han-qi SHI Yu-hua 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第2期203-207,共5页
The ultrasonic nebulization extraction(UNE) was developed and applied to the extraction of volatile components from traditional Chinese patent medicine Xiaoyao Pills. Several parameters of ultrasonic nebulization ex... The ultrasonic nebulization extraction(UNE) was developed and applied to the extraction of volatile components from traditional Chinese patent medicine Xiaoyao Pills. Several parameters of ultrasonic nebulization extraction including the sample particle size, solvent volume, extraction time and ultrasonic power were studied and selected. As a result, 2.4 g of sample with particle size of 80 mesh was extracted with 15 mL of n-hexane for 20 min at an ultrasonic power of 35 W. The volatile components were analyzed by gas chromatography-mass spectrometry (GC-MS) under the optimal conditions and 57 compounds were identified. The precision, repeatability and stability of the proposed method were also studied. Compared with ultrasonic-assisted extraction(UAE) and hydrodistillation(HD) extraction, the proposed method is more efficient, faster and easier to be operated at room temperature with smaller sample and energy consumption. It is suggested that the ultrasonic nebulization extraction can be used as a novel alternative method for the extraction of volatile components from traditional Chinese patent medicine. 展开更多
关键词 Ultrasonic nebulization extraction gas chromatography-mass spectrometry Volatile component Traditional Chinese patent medicine
下载PDF
Influence of Ambient Gas on Laser-Induced Breakdown Spectroscopy of Uranium Metal 被引量:1
20
作者 张大成 马新文 +1 位作者 王书龙 朱小龙 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期971-974,共4页
Laser-induced breakdown spectroscopy (LIBS) is regarded as a suitable method for the remote analysis of materials in any phase, even in an environment with high radiation levels. In the present work we used the thir... Laser-induced breakdown spectroscopy (LIBS) is regarded as a suitable method for the remote analysis of materials in any phase, even in an environment with high radiation levels. In the present work we used the third harmonic pulse of a Nd:YAG laser for ablation of uranium metal and measured the plasma emission with a fiber-optic spectrometer. The LIBS spectra of uranium metal and their features in different ambient gases (i.e., argon, neon, oxygen, and nitrogen) at atmospheric pressure were studied. Strong continuum spectrum and several hundreds of emission lines from UI and UII were observed. It is found that the continuum spectrum observed in uranium not only comes from bremsstrahlung emission but is also due to the complex spectrum of uranium. The influence of ambient gas and the gas flow rate for ablation of uranium metal was investigated. The experimental results indicate that the intensity of the uranium lines was enhanced in argon and nitrogen. However, the intensity of uranium lines was decreased in oxygen due to the generation of UO and other oxides. The results also showed that the highest intensity of uranium lines were obtained in argon gas with a gas flow rate above 2.5 L/min. The enhanced mechanism in ambient gas and the influence of the gas flow rate were analyzed in this work. 展开更多
关键词 laser-induced breakdown spectroscopy URANIUM ambient gas
下载PDF
上一页 1 2 14 下一页 到第
使用帮助 返回顶部