In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorpti...In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorption/desorption device. Based on the characteristics of gas desorption from coal samples, we proposed a direct fitting method for measurement of gas content in coalbed, analyzed the effects of sampling time on the measurement results and determined the reasonable sampling time of coal samples with different metamorphic grades at different gas adsorption pressure at equilibrium. The results show that (1)the error of gas contents obtained using the direct fitting method relative to that obtained using indirect method is less than 10%, which meets the actual on-site requirements and verifies the feasibility of the direct fitting method;(2) when the relative error is controlled within ±10%, the reasonable sampling time of coal samples is linearly related to the gas adsorption pressure at equilibrium;(3) the reasonable sampling time of coal samples with the same metamorphic grade exhibits a shortening trend with increasing gas adsorption pressure at equilibrium;(4) for coal samples with similar gas adsorption pressure at equilibrium, the reasonable sampling time of coal samples displays a shortening trend with increasing metamorphic grade. Overall, the study provides a basis for improving the measurement accuracy of gas content in coalbed.展开更多
The analytical mathematical solutions of gas concentration and fractional gas loss for the diffusion of gas in a cylindrical coal sample were given with detailed mathematical derivations by assuming that the diffusion...The analytical mathematical solutions of gas concentration and fractional gas loss for the diffusion of gas in a cylindrical coal sample were given with detailed mathematical derivations by assuming that the diffusion of gas through the coal matrix is concentration gradient-driven and obeys the Fick’s Second Law of Diffusion.The analytical solutions were approximated in case of small values of time and the error analyses associated with the approximation were also undertaken.The results indicate that the square root relationship of gas release in the early stage of desorption,which is widely used to provide a simple and fast estimation of the lost gas,is the first term of the approximation,and care must be taken in using the square root relationship as a significant error might be introduced with increase in the lost time and decrease in effective diameter of a cylindrical coal sample.展开更多
We have investigated the role of the ambient gas nature and pressure in the structure and appearance of the laser treated zone. and the influence of the total duration and temporal shape of laser pulse with the laser ...We have investigated the role of the ambient gas nature and pressure in the structure and appearance of the laser treated zone. and the influence of the total duration and temporal shape of laser pulse with the laser tight being λ= 10.6μm wavelength incident upon a metallic surface at intermediate taser intensities of 107-108 W / cm2. A plasma is accompanied by the action of the laser pulse, It acts as an active moderator among laser beam and target thus determining the final status of the contact surface展开更多
In this study,graphene oxide was covalently immobilized on silica-coated magnetite and then modified with 2-phenylethylamine to give a nanocomposite of type Fe3O4@SiO2@GO-PEA that can be applied to the magnetic solid-...In this study,graphene oxide was covalently immobilized on silica-coated magnetite and then modified with 2-phenylethylamine to give a nanocomposite of type Fe3O4@SiO2@GO-PEA that can be applied to the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons(PAHs) from water samples.The resulting microspheres(Fe3O4@SiO2@GO-PEA) were characterized by Fourier transform-infrared spectroscopy(FT-IR),scanning electron microscopy(SEM),CHNS elemental analysis,and vibrating sample magnetometry(VSM) techniques.The adsorbent possesses the magnetic properties of Fe3O4 nanoparticles that allow them easily to be separated by an external magnetic field.They also have the high specific surface area of graphene oxide which improves adsorption capacity.Desorption conditions,extraction time,amount of adsorbent,salt concentration,and pH were investigated and optimized.Following desorption,the PAHs were quantified by gas chromatography with flame ionization detection(GC-FID).The limits of detection(at an S/N ratio of 3) were achieved from 0.005 to0.1 μg/L with regression coefficients(R2) higher than 0.9954.The relative standard deviations(RSDs) were below 5.8%(intraday) and 6.2%(inter-day),respectively.The method was successfully applied to the analysis of PAHs in environmental water samples where it showed recoveries in the range between 71.7%and 106.7%(with RSDs of 1.6%to 8.4%,for n = 3).The results indicated that the Fe3O4@SiO2@GO-PEA microspheres had a great promise to extraction of PAHs from different water samples.展开更多
In anaerobic digestion, the production of short-chain fatty acids (SCFAs) can be beneficial or harmful to the overall process, depending on the concentration of accumulated acids. Therefore, the accurate determinati...In anaerobic digestion, the production of short-chain fatty acids (SCFAs) can be beneficial or harmful to the overall process, depending on the concentration of accumulated acids. Therefore, the accurate determination of the SCFA concentration in both fresh and stored sludge hydrolysates is important. To select a suitable method for monitoring SCFAs during the anaerobic digestion of sewage sludge, the accuracy of three available analytical methods, including 5 pH point acid titration (TITRA5), gas chromatography (GC), and spectrophotometry, were compared in the present study. The results revealed that TITRA5 and GC displayed better agreement in the achieved measurements and higher precision and accuracy than the spectrophotometric assay, as supported by the application of different statistical models. TITRA5 excelled in titrating unfiltered hydrolysate while simultaneously measuring the alkalinity, whereas the GC method provided detailed information on the contribution of different fatty acids to the total acidity. In contrast, the spectrophotometric assay suffered from many forms of interference, depending on the sample's matrix. SCFA production followed the pattern of enzymatic reactions and fitted the Michaelis-Menten model. In addition to promoting TITRA5 as an accurate and robust analytical tool for routine SCFA analyses, this comparative study also demonstrated the possibility of storing hydrolysate samples at different temperatures and durations without altering the SCFA measurements.展开更多
基金the support of the National Natural Science Foundation of China(Nos.51674158,51604168 and 51504142)the Natural Science Foundation of Shandong Province(No.ZR2016EEQ18)+2 种基金the SDUST Research Fund(No.2015JQJH105)the Qingdao Postdoctoral Applied Research Project(No.2015204)the Taishan Scholar Talent Team Support Plan for Advantaged&Unique Discipline Areas
文摘In this study, we selected 9 typical coal samples with different metamorphic grades as the study subjects,measured their initial 30-min gas desorption at 30℃ and different pressure using a self-developed gas adsorption/desorption device. Based on the characteristics of gas desorption from coal samples, we proposed a direct fitting method for measurement of gas content in coalbed, analyzed the effects of sampling time on the measurement results and determined the reasonable sampling time of coal samples with different metamorphic grades at different gas adsorption pressure at equilibrium. The results show that (1)the error of gas contents obtained using the direct fitting method relative to that obtained using indirect method is less than 10%, which meets the actual on-site requirements and verifies the feasibility of the direct fitting method;(2) when the relative error is controlled within ±10%, the reasonable sampling time of coal samples is linearly related to the gas adsorption pressure at equilibrium;(3) the reasonable sampling time of coal samples with the same metamorphic grade exhibits a shortening trend with increasing gas adsorption pressure at equilibrium;(4) for coal samples with similar gas adsorption pressure at equilibrium, the reasonable sampling time of coal samples displays a shortening trend with increasing metamorphic grade. Overall, the study provides a basis for improving the measurement accuracy of gas content in coalbed.
基金provided by the Science and Technology Grant of Huainan City of China (No.2013A4001)the Key Research Grant of Shanxi Province of China (No.201303027-1)
文摘The analytical mathematical solutions of gas concentration and fractional gas loss for the diffusion of gas in a cylindrical coal sample were given with detailed mathematical derivations by assuming that the diffusion of gas through the coal matrix is concentration gradient-driven and obeys the Fick’s Second Law of Diffusion.The analytical solutions were approximated in case of small values of time and the error analyses associated with the approximation were also undertaken.The results indicate that the square root relationship of gas release in the early stage of desorption,which is widely used to provide a simple and fast estimation of the lost gas,is the first term of the approximation,and care must be taken in using the square root relationship as a significant error might be introduced with increase in the lost time and decrease in effective diameter of a cylindrical coal sample.
文摘We have investigated the role of the ambient gas nature and pressure in the structure and appearance of the laser treated zone. and the influence of the total duration and temporal shape of laser pulse with the laser tight being λ= 10.6μm wavelength incident upon a metallic surface at intermediate taser intensities of 107-108 W / cm2. A plasma is accompanied by the action of the laser pulse, It acts as an active moderator among laser beam and target thus determining the final status of the contact surface
文摘In this study,graphene oxide was covalently immobilized on silica-coated magnetite and then modified with 2-phenylethylamine to give a nanocomposite of type Fe3O4@SiO2@GO-PEA that can be applied to the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons(PAHs) from water samples.The resulting microspheres(Fe3O4@SiO2@GO-PEA) were characterized by Fourier transform-infrared spectroscopy(FT-IR),scanning electron microscopy(SEM),CHNS elemental analysis,and vibrating sample magnetometry(VSM) techniques.The adsorbent possesses the magnetic properties of Fe3O4 nanoparticles that allow them easily to be separated by an external magnetic field.They also have the high specific surface area of graphene oxide which improves adsorption capacity.Desorption conditions,extraction time,amount of adsorbent,salt concentration,and pH were investigated and optimized.Following desorption,the PAHs were quantified by gas chromatography with flame ionization detection(GC-FID).The limits of detection(at an S/N ratio of 3) were achieved from 0.005 to0.1 μg/L with regression coefficients(R2) higher than 0.9954.The relative standard deviations(RSDs) were below 5.8%(intraday) and 6.2%(inter-day),respectively.The method was successfully applied to the analysis of PAHs in environmental water samples where it showed recoveries in the range between 71.7%and 106.7%(with RSDs of 1.6%to 8.4%,for n = 3).The results indicated that the Fe3O4@SiO2@GO-PEA microspheres had a great promise to extraction of PAHs from different water samples.
文摘In anaerobic digestion, the production of short-chain fatty acids (SCFAs) can be beneficial or harmful to the overall process, depending on the concentration of accumulated acids. Therefore, the accurate determination of the SCFA concentration in both fresh and stored sludge hydrolysates is important. To select a suitable method for monitoring SCFAs during the anaerobic digestion of sewage sludge, the accuracy of three available analytical methods, including 5 pH point acid titration (TITRA5), gas chromatography (GC), and spectrophotometry, were compared in the present study. The results revealed that TITRA5 and GC displayed better agreement in the achieved measurements and higher precision and accuracy than the spectrophotometric assay, as supported by the application of different statistical models. TITRA5 excelled in titrating unfiltered hydrolysate while simultaneously measuring the alkalinity, whereas the GC method provided detailed information on the contribution of different fatty acids to the total acidity. In contrast, the spectrophotometric assay suffered from many forms of interference, depending on the sample's matrix. SCFA production followed the pattern of enzymatic reactions and fitted the Michaelis-Menten model. In addition to promoting TITRA5 as an accurate and robust analytical tool for routine SCFA analyses, this comparative study also demonstrated the possibility of storing hydrolysate samples at different temperatures and durations without altering the SCFA measurements.