期刊文献+
共找到63篇文章
< 1 2 4 >
每页显示 20 50 100
Self-absorption effects of laser-induced breakdown spectroscopy under different gases and gas pressures 被引量:1
1
作者 王崧宁 张殿鑫 +6 位作者 陈楠 何亚雄 张红 柯川 许涛 陈永亮 赵勇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第2期155-162,共8页
The self-absorption effect is one of the main factors affecting the quantitative analysis accuracy of laser-induced breakdown spectroscopy.In this paper,the self-absorption effects of laserinduced 7050 Al alloy plasma... The self-absorption effect is one of the main factors affecting the quantitative analysis accuracy of laser-induced breakdown spectroscopy.In this paper,the self-absorption effects of laserinduced 7050 Al alloy plasma under different pressures in air,Ar,and N2have been studied.Compared with air and N2,Ar significantly enhances the spectral signal.Furthermore,the spectral self-absorption coefficient is calculated to quantify the degree of self-absorption,and the influences of gas species and gas pressure on self-absorption are analyzed.In addition,it is found that the spectral intensity fluctuates with the change of pressure of three gases.It can also be seen that the fluctuation of spectral intensity with pressure is eliminated after correcting,which indicates that the self-absorption leads to the fluctuation of spectral intensity under different pressures.The analysis shows that the evolution of optical thin spectral lines with pressure in different gases is mainly determined by the gas properties and the competition between plasma confinement and Rayleigh–Taylor instability. 展开更多
关键词 self-absorption coefficient ambient gases gas pressure laser-induced breakdown spectroscopy
下载PDF
Measuring stellar populations,dust attenuation and ionized gas at kpc scales in 10010 nearby galaxies using the integral field spectroscopy from MaNGA
2
作者 李牛 李成 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期1-7,共7页
As one of the three major experiments of the fourth-generation Sloan Digital Sky Survey(SDSS-IV),the Mapping Nearby Galaxies at Apatch Point Observatory(MaNGA)survey has obtained high-quality integral field spectrosco... As one of the three major experiments of the fourth-generation Sloan Digital Sky Survey(SDSS-IV),the Mapping Nearby Galaxies at Apatch Point Observatory(MaNGA)survey has obtained high-quality integral field spectroscopy(IFS)with a resolution of 1–2 kpc for104galaxies in the local universe during its six-year operation from July 2014 through August 2020.It is crucial to reliably measure the physical properties of the different components in each spectrum before one can use the data for any scientific study.In the past years we have made lots of efforts to develop a novel technique of full spectral fitting,which estimates a model-independent dust attenuation curve from each spectrum,thus allowing us to break the degeneracy between dust attenuation and stellar population properties when fitting the spectrum with stellar population synthesis models.We have applied our technique to the final data release of Ma NGA,and obtained measurements of stellar population properties and emission line parameters,as well as the kinematics and dust attenuation of both stellar and ionized gas components.In this paper we describe our technique and the content and format of our data products.The whole dataset is publicly available in Science Data Bank with the link https://doi.org/10.57760/sciencedb.j00113.00088. 展开更多
关键词 integral field spectroscopy stellar populations dust attenuation ionized gas
下载PDF
Experimental study on mercury content in flue gas of coal-fired units based on laser-induced breakdown spectroscopy 被引量:3
3
作者 荣凯 王珍珍 +4 位作者 胡若木 刘人玮 出口祥啓 严俊杰 刘继平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第7期75-82,共8页
Accurate measurement of trace heavy metal mercury(Hg) in flue gas of coal-fired units is great significance for ecological and environmental protection.Mixed gas was used to simulate the actual flue gas of a power pla... Accurate measurement of trace heavy metal mercury(Hg) in flue gas of coal-fired units is great significance for ecological and environmental protection.Mixed gas was used to simulate the actual flue gas of a power plant in this study.A laser-induced breakdown spectroscopy(LIBS)system for Hg measurement in mixed gas was built to study the effect of mixed gas pressure,Hg concentration in mixed gas and delay time on Hg measurement.The experimental results show that the appropriate low mixed gas pressure can obtain high Hg signal intensity and signal to noise ratio.The Hg signal intensity and signal to noise ratio increased with the increase of Hg concentration in mixed gas.The Hg signal intensity and signal to noise ratio decreased with the increase in delay time.According to the above results,the optimized measurement conditions can be determined.Different Hg concentrations in mixed gas were quantitatively analyzed by the internal standard method and traditional calibration method respectively.The relative error of prediction of the test sample obtained by the internal standard method was within 11.11%.The relative error of prediction of the traditional calibration method was less than 14.54%.This proved that the internal standard method can improve the accuracy of quantitative analysis of Hg concentration in flue gas using LIBS. 展开更多
关键词 laser-induced breakdown spectroscopy flue gas trace heavy metal quantitative analysis
下载PDF
Wavelength modulation spectroscopy for measurements of gas parameters in combustion field 被引量:1
4
作者 屈东胜 洪延姬 +1 位作者 王广宇 潘虎 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第6期178-186,共9页
A novel wavelength modulation spectroscopy sensor for studying gas properties near 1.4 μm is developed, validated and used in a direct-connect supersonic combustion test facility. In this sensor there are two H2O tra... A novel wavelength modulation spectroscopy sensor for studying gas properties near 1.4 μm is developed, validated and used in a direct-connect supersonic combustion test facility. In this sensor there are two H2O transitions near 7185.60 cm^-1 and 7454.45 cm^-1 that are used to enable the measurements along the line-of-sight. According to an iterative algorithm, the gas pressure, temperature and species mole fraction can be measured simultaneously. The new sensor is used in the isolator and extender of the supersonic combustion test facility. In the isolator, the sensor resolves the transient and measured pressure, temperature and H2O mole fraction with accuracies of 2.5%, 8.2%, and 7.2%, respectively. Due to the non-uniform characteristic in the extender, the measured results cannot precisely characterize gas properties, but they can qualitatively describe the distinctions of different zones or the changes or fluctuations of the gas parameters. 展开更多
关键词 wavelength modulation spectroscopy SENSOR gas properties iterative algorithm
下载PDF
Super Antibiotics, Part II. Hyperforin, Mass Spectroscopy (MS) and Gas Chromatography-Mass Spectrometry (GC-MS), Evidence of Permeability of the Blood-Testis Barrier (BTB) and the Blood-Brain Barrier (BBB) to Hyperforin 被引量:2
5
作者 Ilia Brondz 《International Journal of Analytical Mass Spectrometry and Chromatography》 2016年第4期66-73,共8页
In the first article of this series, we presented some evidence of hyperforin as an antibiotic, antiprotozoal, antiviral, anticancer, and immunomodulatory substance. In the present article, evidence of the permeabilit... In the first article of this series, we presented some evidence of hyperforin as an antibiotic, antiprotozoal, antiviral, anticancer, and immunomodulatory substance. In the present article, evidence of the permeability of the blood-testis barrier (BTB) and blood-brain barrier (BBB) to hyperforin and its distribution in other organs of the domestic pig (Sus scrofa domesticus) are revealed. Seven-month-old male boars with a body mass of 100 kg were fed a diet containing hyperforin. Organs were surgically removed under anesthesia. Organs were suitable prepared and extracted, and then analyzed using gas chromatography-mass spectrometry with supersonic molecular beams (GC-MS with SMB). The presence of hyperforin was recorded in all organs and body fluids. Special attention was paid to the evaluation of the presence of hyperforin in the brain and testes of experimental animals. The presence of hyperforin in the brain and testes of experimental animals was established by GC-MS with SMB. The results are of interest because penicillin and numerous other antibiotics cannot pass through the BTB or BBB if healthy or non-inflamed, which limits their use in patients with meningitis and gonorrhea. The findings are also of interest in cases of penicillin- and multi-antibiotic-resistant bacterial infections. 展开更多
关键词 ANTIBIOTICS HYPERFORIN Super antibiotic Mass spectroscopy gas Chromatography-Mass Spectrometry Blood-Testis Barrier Blood-Brain Barrier Methicillin-Resistant Staphylococcus aureus (MRSA)
下载PDF
Influence of Ambient Gas on Laser-Induced Breakdown Spectroscopy of Uranium Metal
6
作者 张大成 马新文 +1 位作者 王书龙 朱小龙 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期971-974,共4页
Laser-induced breakdown spectroscopy (LIBS) is regarded as a suitable method for the remote analysis of materials in any phase, even in an environment with high radiation levels. In the present work we used the thir... Laser-induced breakdown spectroscopy (LIBS) is regarded as a suitable method for the remote analysis of materials in any phase, even in an environment with high radiation levels. In the present work we used the third harmonic pulse of a Nd:YAG laser for ablation of uranium metal and measured the plasma emission with a fiber-optic spectrometer. The LIBS spectra of uranium metal and their features in different ambient gases (i.e., argon, neon, oxygen, and nitrogen) at atmospheric pressure were studied. Strong continuum spectrum and several hundreds of emission lines from UI and UII were observed. It is found that the continuum spectrum observed in uranium not only comes from bremsstrahlung emission but is also due to the complex spectrum of uranium. The influence of ambient gas and the gas flow rate for ablation of uranium metal was investigated. The experimental results indicate that the intensity of the uranium lines was enhanced in argon and nitrogen. However, the intensity of uranium lines was decreased in oxygen due to the generation of UO and other oxides. The results also showed that the highest intensity of uranium lines were obtained in argon gas with a gas flow rate above 2.5 L/min. The enhanced mechanism in ambient gas and the influence of the gas flow rate were analyzed in this work. 展开更多
关键词 laser-induced breakdown spectroscopy URANIUM ambient gas
下载PDF
Observation of photon recoil effects in single-beam absorption spectroscopy with an ultracold strontium gas
7
作者 胡发超 檀灿竹 +2 位作者 江玉海 Matthias Weidemüller 朱兵 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第1期485-491,共7页
We report on observing photon recoil effects in the absorption of a single monochromatic light at 689 nm through an ultracold ^(88)Sr gas,where the recoil frequency is comparable to natural linewidth of the narrow-lin... We report on observing photon recoil effects in the absorption of a single monochromatic light at 689 nm through an ultracold ^(88)Sr gas,where the recoil frequency is comparable to natural linewidth of the narrow-line transition 5s^(2) ^(1)S_(0)-5s5p ^(3)P_(1) in strontium.In the regime of high-saturation,the absorption profile becomes asymmetric due to the photon-recoil shift,which is of the same order as the natural linewidth.The lineshape is described by an extension of the optical Bloch equations including the momentum transfers to atoms during emission and absorption of photons.Our work reveals the photon recoil effects in a simplest single-beam absorption setting,which is of significant relevance to other applications such as saturation spectroscopy,Ramsey interferometry,and absorption imaging. 展开更多
关键词 photon recoil absorption spectroscopy ultracold strontium gas
下载PDF
Wide dynamic detection range of methane gas based on enhanced cavity absorption spectroscopy
8
作者 汪玉 丁伯坤 +4 位作者 王坤阳 梅教旭 韩泽林 谈图 高晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第4期244-248,共5页
Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have ... Integrated cavity output spectroscopy(ICOS) is an effective technique in trace gase detection.The strong absorption due to the long optical path of this method makes it challenging in the application scenes that have large gas concentration fluctuation,especially when the gas concentration is high.In this paper,we demonstrate an extension of the dynamic range of ICOS by using a detuned laser combined with an off-axis integrating cavity.With this,we improve the upper limit of the dynamic detection range from 0.1%(1000 ppm) to 20% of the gas concentration.This method provides a way of using ICOS in the applications with unpredictable gas concentrations such as gas leak detection,ocean acidification,carbon sequestration,etc. 展开更多
关键词 integrated cavity output spectroscopy(ICOS) trace gas wide dynamic detection absorption positions
下载PDF
Test on oxygen and benzene contents in gasoline by mid-infrared spectroscopy
9
作者 姜旭峰 赵媛莉 +1 位作者 校云鹏 孙静 《Journal of Measurement Science and Instrumentation》 CAS 2013年第3期299-301,共3页
This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,t... This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,this paper draws a conclusion that IR has several advantages,including rapid analysis,excellent repeatability and low analysis cost. 展开更多
关键词 OXYGEN BENZENE mid-infrared spectroscopy gasOLINE gas chromatography(GC)
下载PDF
A highly sensitive LITES sensor based on a multi-pass cell with dense spot pattern and a novel quartz tuning fork with low frequency
10
作者 Yahui Liu Shunda Qiao +4 位作者 Chao Fang Ying He Haiyue Sun Jian Liu Yufei Ma 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第3期26-34,共9页
A highly sensitive light-induced thermoelectric spectroscopy(LITES)sensor based on a multi-pass cell(MPC)with dense spot pattern and a novel quartz tuning fork(QTF)with low resonance frequency is reported in this manu... A highly sensitive light-induced thermoelectric spectroscopy(LITES)sensor based on a multi-pass cell(MPC)with dense spot pattern and a novel quartz tuning fork(QTF)with low resonance frequency is reported in this manuscript.An erbi-um-doped fiber amplifier(EDFA)was employed to amplify the output optical power so that the signal level was further enhanced.The optical path length(OPL)and the ratio of optical path length to volume(RLV)of the MPC is 37.7 m and 13.8 cm^(-2),respectively.A commercial QTF and a self-designed trapezoidal-tip QTF with low frequency of 9461.83 Hz were used as the detectors of the sensor,respectively.The target gas selected to test the performance of the system was acetylene(C2H2).When the optical power was constant at 1000 mW,the minimum detection limit(MDL)of the C2H2-LITES sensor can be achieved 48.3 ppb when using the commercial QTF and 24.6 ppb when using the trapezoid-al-tip QTF.An improvement of the detection performance by a factor of 1.96 was achieved after replacing the commer-cial QTF with the trapezoidal-tip QTF. 展开更多
关键词 light-induced thermoelectric spectroscopy quartz tuning fork multi-pass cell gas sensing
下载PDF
On-chip readout plasmonic mid-IR gas sensor 被引量:5
11
作者 Qin Chen Li Liang +2 位作者 Qilin Zheng Yaxin Zhang Long Wen 《Opto-Electronic Advances》 2020年第7期17-28,I0002,共13页
Gas identification and concentration measurements are important for both understanding and monitoring a variety of phenomena from industrial processes to environmental change.Here a novel mid-IR plasmonic gas sensor w... Gas identification and concentration measurements are important for both understanding and monitoring a variety of phenomena from industrial processes to environmental change.Here a novel mid-IR plasmonic gas sensor with on-chip direct readout is proposed based on unity integration of narrowband spectral response,localized field enhancement and thermal detection.A systematic investigation consisting of both optical and thermal simulations for gas sensing is presented for the first time in three sensing modes including refractive index sensing,absorption sensing and spectroscopy,respectively.It is found that a detection limit less than 100 ppm for CO2 could be realized by a combination of surface plasmon resonance enhancement and metal-organic framework gas enrichment with an enhancement factor over 8000 in an ultracompact optical interaction length of only several microns.Moreover,on-chip spectroscopy is demonstrated with the compressive sensing algorithm via a narrowband plasmonic sensor array.An array of 80 such sensors with an average resonance linewidth of 10 nm reconstructs the CO2 molecular absorption spectrum with the estimated resolution of approximately 0.01 nm far beyond the state-of-the-art spectrometer.The novel device design and analytical method are expected to provide a promising technique for extensive applications of distributed or portable mid-IR gas sensor. 展开更多
关键词 gas sensor MID-IR ON-CHIP surface plasmon resonance spectroscopy
下载PDF
Influence of Additive Gas on Electrical and Optical Characteristics of Non-equilibrium Atmospheric Pressure Argon Plasma Jet 被引量:1
12
作者 费小猛 Shin-ichi KURODA +2 位作者 Yuki KONDO Tamio MORI Katsuhiko HOSOI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第5期575-582,共8页
Electrical and optical properties of an argon plasma jet were characterized. In particular, effects of an additive gas, namely nitrogen or oxygen, on these properties were studied in detail. The plasma jet was found t... Electrical and optical properties of an argon plasma jet were characterized. In particular, effects of an additive gas, namely nitrogen or oxygen, on these properties were studied in detail. The plasma jet was found to be of a glow-like discharge, which scarcely changed upon the injection of an additive gas, either directly or through a glass capillary. Optical emission spectroscopy characterization revealed that excited argon atoms were the predominant active species in this plasma jet. Metastable argon atoms were highly quenched, and N2(C3yIu) became the main energy carrier following nitrogen injection. When oxygen was added to the afterglow zone through a glass capillary, no significant quenching effect was observed and the number of oxygen atoms decreased with the increase in oxygen concentration. Finally, to demonstrate an application of this plasma jet, a high-density polyethylene surface was treated with argon, argon/nitrogen, and argon/oxygen plasmas. 展开更多
关键词 atmospheric pressure Ar plasma jet additive gas DISCHARGE optical emission spectroscopy
下载PDF
High-sensitivity methane monitoring based on quasi-fundamental mode matched continuous-wave cavity ring-down spectroscopy 被引量:1
13
作者 李哲 杨爽 +6 位作者 张志荣 夏滑 庞涛 吴边 孙鹏帅 王华东 余润磬 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第9期326-332,共7页
Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric met... Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric methane monitoring.The problem of mode matching is explained from the perspective of transverse mode and longitudinal mode,and the influence of laser injection efficiency on measurement precision is further analyzed.The results of cavity ring-down time measurement show that the measurement precision is higher when the laser is coupled with the fundamental mode.In the experiment,DFB laser is used to calibrate the system with standard methane concentration,and the measurement residual is less than±4×10^(-4)μs^(-1).The methane concentration in the air is monitored in real time for two days.The results show the consistency of the concentration changes over the two days,which further demonstrates the reliability of the system for the measurement of trace methane.By analyzing the influence of mode matching,it not only assists the adjustment of the optical path,but also further improves the sensitivity of the system measurement. 展开更多
关键词 continuous-wave cavity ring-down spectroscopy(CW-CRDS) cavity modes coupling efficiency mode matching greenhouse gas
下载PDF
Noninvasive Detection of the Gases Inside the Sealed Batteries by the On-line Mass Spectrometry
14
作者 XiaoRongZHOU PeiFangLIU LinZHUANG JunTaoLU 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第7期823-826,共4页
关键词 Mass spectroscopy gas evolution BATTERIES OVERCHARGE noninvasive.
下载PDF
Infrared Spectroscopy of Neutral and Cationic Pyrrolidine Monomer in Supersonic Jet
15
作者 Min Xie Zhao-li Zhang +3 位作者 Yu Zhang Xiao-nan Sun Fu-fei Sun Yong-jun Hu 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2020年第1期43-47,I0005,I0006,共7页
Pyrrolidine,a five membered heterocyclic molecule,is widely existing in organism.Herein,infrared spectra of pyrrolidine monomer in neutral and cationic states were obtained by vacuum ultraviolet ionization,infrared ph... Pyrrolidine,a five membered heterocyclic molecule,is widely existing in organism.Herein,infrared spectra of pyrrolidine monomer in neutral and cationic states were obtained by vacuum ultraviolet ionization,infrared photodissociation and time of flight mass spectrometry.Both in neutral and cationic states,it is found that their CH stretching vibration bands are red shifted.In the IR spectrum of neutral pyrrolidine,because the electric dipole moment of NH is small,we have not observed the NH stretching vibration bands.However,the NH stretching vibration band of pyrrolidine is greatly enhanced after ionization,and this band red-shifts compared with the previous experiment.The red shifts of CH stretching vibrations in neutral and cationic states are caused by the negative and positive hyperconjugation,respectively.The enhancement and red shift of the NH stretching band are owing to the ejection of the electrons on the N atom after ionization.Through the calculations,it is found that the acidity of the CH bond is a little stronger than that of NH bond.These kinds of studies would be helpful to understand the intrinsic properties of biomolecules in neutral and cationic states,and to provide reference for the further study of living organic macromolecules. 展开更多
关键词 IR spectroscopy HYPERCONJUGATION Cationic state CH bond acidity gas phase
下载PDF
Characteristics of C_2 Radical in CHF_3 and CF_4 Electron Cyclotron Resonance Plasmas Studied by Optical Emission Spectroscopy
16
作者 杜伟 叶超 +1 位作者 程珊华 宁兆元 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第6期1535-1540,共6页
The characteristics of CHF3 and CF4 electron cyclotron resonance (ECR) plasma have been studied by optical emission spectroscopy (OES) and Langmuir probe. It is found that C2 radical is one of main compositions in bot... The characteristics of CHF3 and CF4 electron cyclotron resonance (ECR) plasma have been studied by optical emission spectroscopy (OES) and Langmuir probe. It is found that C2 radical is one of main compositions in both of the two plasmas. We investigated the relative concentration of C2 radical as a function of F (H) radical and ion density. The formation mechanism of C2 radical is analyzed. 展开更多
关键词 ECR plasma optical emission spectroscopy fluorocarbon gas
下载PDF
An intra-cavity absorption fiber gas sensor based on performanceenhanced techniques
17
作者 LI Mo1 YANG Fan +1 位作者 LUO Yanhua PENG Gangding 《太赫兹科学与电子信息学报》 2015年第4期653-658,共6页
The performance of an erbium-doped fiber ring laser based intra-cavity absorption gassensor was evaluated with performance enhanced techniques. A multi-line wavelength sweep techniqueand a weighted averaging technique... The performance of an erbium-doped fiber ring laser based intra-cavity absorption gassensor was evaluated with performance enhanced techniques. A multi-line wavelength sweep techniqueand a weighted averaging technique were proposed for better gas detection. By selecting appropriatesystem parameters, 6 strong absorption lines near 1 530 nm of C2H2 were obtained with good spectrumresolution in one scanning period. One group with higher absorption coefficients was used for relativelylow gas concentration detection and the other with lower absorption coefficients was used for relativelyhigh gas concentration. Both the groups can be used for medium gas concentration detection. For variousconcentration cases, by choosing proper absorption lines and performing weighted averaging, detectionaccuracy can be obtained over an extended detection range. The minimum detection limit could be verylow after optimization. 展开更多
关键词 FIBER gas sensor intra-cavity ABSORPTION spectroscopy multi-line WAVELENGTH sweeptechnique WEIGHTED AVERAGING techni
下载PDF
Absorption Line Profile Recovery Based on TDLS and MEMS Micro-Mirror for Photoacoustic Gas Sensing
18
作者 LI Li Norhana Arsad +3 位作者 George Stewart Deepak Uttamchandani Brian Culshaw WANG Yi-ding 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2011年第7期1814-1818,共5页
A novel and efficient absorption line recovery technique is presented.A micro-electromechanical systems(MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirr... A novel and efficient absorption line recovery technique is presented.A micro-electromechanical systems(MEMS) mirror driven by an electrothermal actuator is used to generate laser intensity modulation through the mirror reflection.Tunable diode laser spectroscopy(TDLS) and photoacoustic spectroscopy(PAS) are used to recover the target absorption line profile which is compared with the theoretical Voigt profile.The target gas is 0.01% acetylene(C2H2) in a nitrogen host gas.The laser diode wavelength is swept across the P17 absorption line of acetylene at 1 535.4 nm by a current ramp,and an erbium-doped fibre amplifier(EDFA) is used to enhance the optical intensity and increase the signal-to-noise ratio(SNR).A SNR of about 35 is obtained with 100 mW laser power from the EDFA.Good agreement is achieved between the experimental results and the theoretical simulation for the P17 absorption line profile. 展开更多
关键词 Micro-electro-mechanical-systems(MEMS) Laser intensity modulation Absorption line profile recovery Tunable diode laser spectroscopy Photo-acoustic gas sensing
下载PDF
Measurements of NO_2 mixing ratios with topographic target light scattering-differential optical absorption spectroscopy system and comparisons to point monitoring technique
19
作者 王杨 李昂 +6 位作者 谢品华 曾议 王瑞斌 陈浩 裴显 刘建国 刘文清 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第11期285-290,共6页
A topographic target light scattering-differential optical absorption spectroscopy ('IbTaL-DOA~) system is de- veloped for measuring average concentrations along a known optical path and studying surface-near distr... A topographic target light scattering-differential optical absorption spectroscopy ('IbTaL-DOA~) system is de- veloped for measuring average concentrations along a known optical path and studying surface-near distributions of atmospheric trace gases. The telescope of the ToTaL-DOAS system points to targets which are located at known dis- tances from the measurement device and illuminated by sunlight. Average concentrations with high spatial resolution can be retrieved by receiving sunlight reflected from the targets, A filed measurement of NO2 concentration is performed with the ToTaL-DOAS system in Shijiazhuang in the autumn of 2011. The measurement data are compared with con- centrations measured by the point monitoring technique at the same site. The results show that the ToTaL-DOAS system is sensitive to the variation of NO2 concentrations along the optical path. 展开更多
关键词 atmospheric optics target light scattering-differential optical absorption spectroscopy(ToTaL-DOAS) atmospheric trace gas averaging mixing ratio
下载PDF
Determination of Integrated Molar Absorption Coefficients for Gaseous Phenol Infrared Bands and Influence of Water Vapor on Their Values
20
作者 Thomas Onfroy Olivier Marie 《American Journal of Analytical Chemistry》 2019年第1期9-22,共14页
The integrated molar absorption coefficients for ν(OH) (3655 cm-1), δ(OH) (Q branch at 1176 cm-1 or whole bands), [ν(CCring) + δ(OH)] (Q branch at 1344 cm-1 or whole bands) and γ(CH) (752 cm-1) were determined at... The integrated molar absorption coefficients for ν(OH) (3655 cm-1), δ(OH) (Q branch at 1176 cm-1 or whole bands), [ν(CCring) + δ(OH)] (Q branch at 1344 cm-1 or whole bands) and γ(CH) (752 cm-1) were determined at 342 K, by recording infrared spectra of pure gaseous phenol at different partial pressure (from 0 to 33 Pa). The integrated molar absorption coefficients (ε) values were obtained with a good reproducibility and the relative uncertainty on the given values is below 2%. The influence of water on the integrated molar absorption coefficients of phenol has been investigated in a large range of nwater/nphenol values (from 0.5 to 6.1 and from 44 to 94) using distinct setups. The infrared spectra of a gas mixture containing a constant amount of phenol and different amount of water were recorded (closed cell) whereas in dynamic condition (under flow) the water partial pressure was kept constant at 1.3 kPa and the phenol partial pressure was increased from 0 to 30 Pa. It is here demonstrated that, at 342 or 355 K, the presence of water does not affect the epsilon values of δ(OH) and [ν(CCring) + δ(OH)] bands. 展开更多
关键词 PHENOL gas INTEGRATED MOLAR Absorption COEFFICIENTS DETERMINATION IR spectroscopy Phenol-Water Interaction PHENOL gas Quantification
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部