Hazardous gas detection systems play an important role in preventing catastrophic gas-related accidents in process industries. Even though effective detection technology currently exists for hazardous gas releases and...Hazardous gas detection systems play an important role in preventing catastrophic gas-related accidents in process industries. Even though effective detection technology currently exists for hazardous gas releases and a majority of process installations have a large number of sensitive detectors in place, the actual operating performance of gas detection systems still does not meet the expected requirements. In this paper, a riskbased methodology is proposed to optimize the placement of hazardous gas detectors. The methodology includes three main steps, namely, the establishment of representative leak scenarios, computational fluid dynamics(CFD)-based gas dispersion modeling, and the establishment of an optimized solution. Based on the combination of gas leak probability and joint distribution probability of wind velocity and wind direction, a quantitative filtering approach is presented to select representative leak scenarios from all potential scenarios. The commercial code ANSYS-FLUENT is used to estimate the consequence of hazardous gas dispersions under various leak and environmental conditions. A stochastic mixed-integer linear programming formulation with the objective of minimizing the total leak risk across all representative leak scenarios is proposed, and the greedy dropping heuristic algorithm(GDHA) is used to solve the optimization model. Finally, a practical application of the methodology is performed to validate its effectiveness for the optimal design of a gas detector system in a high-sulfur natural gas purification plant in Chongqing, China. The results show that an appropriate number of gas detectors with optimal cost-effectiveness can be obtained, and the total leak risk across all potential scenarios can be substantially reduced. This methodology provides an effective approach to guide the optimal placement of pointtype gas detection systems involved with either single or mixed gas releases.展开更多
In this study, we tried to develop the in situ coating methods of hydrophilic polymer solution containing water soluble dye on nonwoven sheet for the colorimetric film sensor. And color change of coated dye according ...In this study, we tried to develop the in situ coating methods of hydrophilic polymer solution containing water soluble dye on nonwoven sheet for the colorimetric film sensor. And color change of coated dye according to contact various gas samples (as strong acid and base, chloroform, ammonia and HF) of this dye-coated nonwoven film was examined for the application of chemically toxic materials detecting tools in the actual site of working place without aid of any kinds of detecting devices. By the addition of electron transfer agent (quinone derivatives), quick color change behaviors were observed within 10 seconds under the contact of various toxic gases in general condition(room temperature, 50% humidity).展开更多
Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of ...Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of the system is improved. The sensitivity of the system is reduced to less than 300 ppm. With WST, sweeping characteristic of the ICFL can be described according to known gas absorption spectra.展开更多
Effective methods are urgently required to optimize Raman spectroscopy technology to ameliorate its low detection sensitivity.Here,we superposed two near-concentric cavities to develop a dual near-concentric cavities ...Effective methods are urgently required to optimize Raman spectroscopy technology to ameliorate its low detection sensitivity.Here,we superposed two near-concentric cavities to develop a dual near-concentric cavities group(DNCCG)to assess its effect on gas Raman signal intensity,signal-to-noise ratio(SNR),and limit of detection(LOD).The results showed that DNCCG generally had higher CO_(2) Raman signal intensity than the sum of two near-concentric cavities.Meanwhile,the noise intensity of DNCCG was not enhanced by the superposition of near-concentric cavities.Accordingly,DNCCG increased the SNR.The LOD for CO_(2) was 24.6 parts per million.DNCCG could be an effective method to improve the detection capability of trace gases and broaden the dynamic detection range,which might aid the future development of innovative technology for multicomponent gas detection.展开更多
Over the past decades,membrane-based separation processes have found numerous applications in various industries.Membrane contactor is an important part of the separation of dissolved gas in the early stage of gas det...Over the past decades,membrane-based separation processes have found numerous applications in various industries.Membrane contactor is an important part of the separation of dissolved gas in the early stage of gas detection.In this paper,to improve efficiency in the detection of the dissolved gas phase in seawater,a better flat membrane contactor is proposed to achieve efficient degassing,inspired by the way fish breathe underwater and the special structure of fish gills.The bioinspired flow channel structures in the flat membrane contactor are suggested along with the distribution of internal blood vessels in the gill platelet and the feature of the gill platelet surface.Using 3D printing,the special degassing devices are manufactured,and comparative analysis of relevant flow parameters is made using different flow channels,combined with the CFD simulation.The final result showed that the proposed flow channel in the degasser achieves a better degassing effect compared with conventional flow channel when the membrane contact area is limited,which can provide good conditions for subsequent gas detection.展开更多
Here,we report a Pd/PdO_(x) sensing material that achieves 1-s detection of 4% H_(2) gas(i.e.,the lower explosive limit concentration for H_(2))at room temperature in air.The Pd/PdO_(x) material is a network of interc...Here,we report a Pd/PdO_(x) sensing material that achieves 1-s detection of 4% H_(2) gas(i.e.,the lower explosive limit concentration for H_(2))at room temperature in air.The Pd/PdO_(x) material is a network of interconnected nanoscopic domains of Pd,PdO,and PdO_(2).Upon exposure to 4% H_(2),PdO and PdO_(2) in the Pd/PdO_(x) are immediately reduced to metallic Pd,generating over a>90% drop in electrical resistance.The mechanistic study reveals that the Pd/PdO_(2) interface in Pd/PdOx is responsible for the ultrafast PdO_(x) reduction.Metallic Pd at the Pd/PdO_(2) interface enables fast H_(2) dissociation to adsorbed H atoms,significantly lowering the PdO2 reduction barrier.In addition,control experiments suggest that the interconnectivity of Pd,PdO,and PdO2 in our Pd/PdO_(x) sensing material further facilitates the reduction of PdO,which would otherwise not occur.The 1-s response time of Pd/PdO_(x) under ambient conditions makes it an excellent alarm for the timely detection of hydrogen gas leaks.展开更多
In this paper, a miniaturized bionic electronic nose system is developed in order to solve the problems arising in oil and gas detection for large size and inflexible operation in downhole. The bionic electronic nose ...In this paper, a miniaturized bionic electronic nose system is developed in order to solve the problems arising in oil and gas detection for large size and inflexible operation in downhole. The bionic electronic nose chamber is designed by mimicking human nasal turbinate structure, V-groove structure on shark skin surface and flow field distribution around skin surface. The sensitivity of the bionic electronic nose system is investigated through experimentation. Radial Basis Function (RBF) and Support Vector Machines (SVM) of 10-fold cross validation are used to compare the recognition performance of the bionic electronic nose system and common one. The results show that the sensitivity of the bionic electronic nose system with bionic composite chamber (chamber B) is significantly improved compared with that with common chamber (chamber A). The recognition rate of chamber B is 4.27% higher than that of chamber A for the RBF algorithm, while for the SVM algorithm, the recognition rate of chamber B is 5.69% higher than that of chamber A. The three-dimensional simulation model of the chamber is built and verified by Computational Fluid Dynamics (CFD) simulation analysis. The number of vortices in chamber B is fewer than that in chamber A. The airflow velocity near the sensors inside chamber B is slower than that inside chamber A. The vortex intensity near the sensors in chamber B is 2.27 times as much as that in chamber A, which facilitates gas molecules to fully contact with the sensor surface and increases the intensity of sensor signal, and the contact strength and time between odorant molecules and sensor surface. Based on the theoretical investigation and test validation, it is believed that the proposed bionic electronic nose system with bionic composite chamber has potential for oil and gas detection in downhole.展开更多
Metal-organic frameworks(MOFs)have been extensively used for gas sorption,storage and separation owing to ultrahigh porosity,exceptional thermal stability,and wide structural diversity.However,when it comes to ultra-l...Metal-organic frameworks(MOFs)have been extensively used for gas sorption,storage and separation owing to ultrahigh porosity,exceptional thermal stability,and wide structural diversity.However,when it comes to ultra-low concentration gas detection,technical bottlenecks of MOFs appear due to the poor adsorption capacity at ppm-/ppblevel concentration and the limited sensitivity for signal transduction.Here,we present hybrid MOF-polymer physi-chemisorption mechanisms integrated with infrared(IR)nanoantennas for highly selective and ultrasensitive CO_(2) detection.To improve the adsorption capacity for trace amounts of gas molecules,MOFs are decorated with amino groups to introduce the chemisorption while maintaining the structural integrity for physisorption.Additionally,leveraging all major optimization methods,a multi-hotspot strategy is proposed to improve the sensitivity of nanoantennas by enhancing the near field and engineering the radiative and absorptive loss.As a benefit,we demonstrate the competitive advantages of our strategy against the state-of-the-art miniaturized IR CO_(2) sensors,including low detection limit,high sensitivity(0.18%/ppm),excellent reversibility(variation within 2%),and high selectivity(against C_(2)H_(5)OH,CH_(3)OH,N_(2)).This work provides valuable insights into the integration of advanced porous materials and nanophotonic devices,which can be further adopted in ultra-low concentration gas monitoring in industry and environmental applications.展开更多
We report a 1.65μm square-Fabry–Pérot[FP]coupled cavity semiconductor laser for methane gas detection.The laser output optical power can reach 7.4 m W with the side mode suppression ratio about 40 d B.The wavel...We report a 1.65μm square-Fabry–Pérot[FP]coupled cavity semiconductor laser for methane gas detection.The laser output optical power can reach 7.4 m W with the side mode suppression ratio about 40 d B.The wavelength tuning range is 2 nm by adjusting the FP cavity injection current,covering the methane absorption line at 1653.72 nm.The lasing wavelength can also be tuned by adjusting the square microcavity injection current or temperature,respectively.Methane gas detection is successfully demonstrated utilizing this laser.展开更多
Based on radon gas properties and its existing projects applications, we firstly attempted to apply geo- physical and chemical properties of radon gas in the field of mining engineering, and imported radioac- tive mea...Based on radon gas properties and its existing projects applications, we firstly attempted to apply geo- physical and chemical properties of radon gas in the field of mining engineering, and imported radioac- tive measurement method to detect the development process of the overlying strata mining-induced fractures and their contained water quality in underground coal mining, which not only innovates a more simple-fast-reliable detection method, but also further expands the applications of radon gas detection technology in mining field. A 3D simulation design of comprehensive testing system for detecting strata mining-induced fractures on surface with radon gas (CTSR) was carried out by using a large-scale 3D solid model design software Pro/Engineer (Pro/E), which overcame three main disadvantages of ''static design thought, 2D planar design and heavy workload for remodification design'' on exiting design for mining engineering test systems. Meanwhile, based on the simulation design results of Pro/E software, the sta- bility of the jack-screw pressure bar for the key component in CTSR was checked with a material mechan- ics theory, which provided a reliable basis for materials selection during the latter machining process.展开更多
To find a neural network model suitable to identify the concentration of mixed pernicious gases in pig house, the quantitative detection model of pernicious gases in pig house was set up based on BP ( Back propagatio...To find a neural network model suitable to identify the concentration of mixed pernicious gases in pig house, the quantitative detection model of pernicious gases in pig house was set up based on BP ( Back propagation) neural network. The BP neural network was trained separately by the three functions, trainbr, traingdm and trainlm, in order to identify the concentration of mixed pernicious gases composed of ammonia gas and hepatic gas. The neural network toolbox in MATLAB software was used to simulate the detection. The results showed that the neural network trained by trainbr function has high average identification accuracy and faster detection speed, and it is also insensitive to noise; therefore, it is suitable to identify the concentration of pemidous gases in pig house. These data provide a reference for intelligent monitoring of pemicious gases in pigsty.展开更多
The feasibility of gas kick early detection outside the riser was analyzed based on gas-liquid multiphase flow theory.Then an experimental platform for gas kick early detection based on Doppler ultrasonic wave was est...The feasibility of gas kick early detection outside the riser was analyzed based on gas-liquid multiphase flow theory.Then an experimental platform for gas kick early detection based on Doppler ultrasonic wave was established and the propagation experiments in two-phase flow of gas-water(sucrose solutions)were conducted.The time and frequency domains of the Doppler ultrasonic wave signals during the experiments were analyzed.The results show that:(1)No matter the pump was on or off,the detected average Doppler ultrasonic signal voltage increased first and then decreased with the increase of the gas void fraction,and had a quadratic function relation with gas void fraction,so the average voltage change of the monitored signals can be used to deduce the approximate gas void fraction.The Doppler ultrasonic wave signal voltage was significantly reduced in magnitude and variation in the solution with higher viscosity,and the viscosity has stronger impact on the magnitude of signal than density.(2)When the pump was stopped,the Doppler shift increased with the increase of gas void fraction,and the two showed a nearly linear relation,so the detected amount of Doppler shift can reflect the variation of gas void fraction quantitatively.When the pump was on,the sound energy produced by frequency converter had a more significant impact on amplitude spectrum than gas void fraction,so it is impossible to determine whether gas kick occurs by frequency domain signal analysis.(3)This method is a non-contact measurement,with no contact with the drilling fluid and no disruption to the drilling operation.It can quantitatively characterize the gas void fraction according to the change of Doppler ultrasonic signal,enabling earlier detection of gas kick.展开更多
Ⅰ The Indexes of Detecting Oil and Gas Resources The deeply buried reservoir which in a dynamic equilibrium state has a great pressure inside, and between it and earth surface there is a great difference of pressure....Ⅰ The Indexes of Detecting Oil and Gas Resources The deeply buried reservoir which in a dynamic equilibrium state has a great pressure inside, and between it and earth surface there is a great difference of pressure. Therefore the hydrocarbon must spread and move vertically to the surface along the pressure gradient orientation. Hydrocarbons in the reservoir along some small rifts, cracks, joints and cleavages penetrate the overlying strata and seepage onto the surface. Thus the hydrocarbons become unvisble oil and gas signs. This process is called the phenomena of hydrocarbon microseepage of reservoir. Hydrocarbons microseepage in the process展开更多
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu...Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly.展开更多
Electronic nose(eNose) is a modern bioelectronic sensor for monitoring biological processes that convert CO_(2) into valueadded products, such as products formed during photosynthesis and microbial fermentation. eNose...Electronic nose(eNose) is a modern bioelectronic sensor for monitoring biological processes that convert CO_(2) into valueadded products, such as products formed during photosynthesis and microbial fermentation. eNose technology uses an array of sensors to detect and quantify gases, including CO_(2), in the air. This study briefly introduces the concept of eNose technology and potential applications thereof in monitoring CO_(2) conversion processes. It also provides background information on biological CO_(2) conversion processes. Furthermore, the working principles of eNose technology vis-à-vis gas detection are discussed along with its advantages and limitations versus traditional monitoring methods. This study also provides case studies that have used this technology for monitoring biological CO_(2) conversion processes. eNose-predicted measurements were observed to be completely aligned with biological parameters for R~2 values of 0.864, 0.808, 0.802, and 0.948. We test eNose technology in a variety of biological settings, such as algae farms or bioreactors, to determine its effectiveness in monitoring CO_(2) conversion processes. We also explore the potential benefits of employing this technology vis-à-vis monitoring biological CO_(2) conversion processes, such as increased reaction efficiency and reduced costs versus traditional monitoring methods. Moreover, future directions and challenges of using this technology in CO_(2) capture and conversion have been discussed. Overall, we believe this study would contribute to developing new and innovative methods for monitoring biological CO_(2) conversion processes and mitigating climate change.展开更多
High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration inf...High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration information is susceptible to noise, which leads to its useful signal being drowned by noise. A fusion algorithm of variational modal decomposition(VMD) and improved wavelet threshold filtering is proposed, which is used in combination with tunable diode laser absorption spectroscopy(TDLAS) to implement a non-contact, high-resolution methane gas concentration detection. The fusion algorithm can perform noise reduction and further segmentation of the methane gas detection signal. And the simulation and experiment verify the effectiveness of the fusion algorithm, and the experimental results show that for the detection of air containing 10 ppm, 30 ppm, 60 ppm, 80 ppm, and 99 ppm methane, the errors are 12.75%, 8.18%, 3.37%, 2.46%, and 1.78%, respectively.展开更多
Wavelength modulation technique (WMT) and wavelength sweep technique (WST) are introduced into intra-cavity absorption gas sensors (ICAGS) for low concentration gas detection. The optimized parameters of the sys...Wavelength modulation technique (WMT) and wavelength sweep technique (WST) are introduced into intra-cavity absorption gas sensors (ICAGS) for low concentration gas detection. The optimized parameters of the system maximizing the signal-to-noise ratio (SNR) are found. Calibration of acetylene concentration and gas recognition are both realized.展开更多
Photoacoustic spectroscopy was used to test the photoacoustic properties of sulfur hexafluoride, an optically thick and potent greenhouse gas. While exploring the photoacoustic effect of sulfur hexafluoride, the effec...Photoacoustic spectroscopy was used to test the photoacoustic properties of sulfur hexafluoride, an optically thick and potent greenhouse gas. While exploring the photoacoustic effect of sulfur hexafluoride, the effects of the position of the microphone within a gas cell were determined. Using a 35 cm gas cell, microphones were positioned at 17.5 cm, the middle of the gas cell, 12.5 cm, 7.5 cm, and 2.5 cm from the window of the cell. From the photoacoustic signal produced for each resonance frequency at each microphone position, the effects of acoustic pressure produced at each position on the signal recorded were observed. This is the first study done by experimentation with the photoacoustic effect to show that standing waves have different amplitudes at different microphone positions.展开更多
This study explored the complex effect of graphite tortuosity on the electrochemical performance of Ni-rich NCA90 Li-ion batteries(LIBs).Different levels of graphite anode tortuosity were analyzed,revealing that low-t...This study explored the complex effect of graphite tortuosity on the electrochemical performance of Ni-rich NCA90 Li-ion batteries(LIBs).Different levels of graphite anode tortuosity were analyzed,revealing that low-tortuosity electrodes had better graphite utilization.The in-plane tortuosities of the graphite anode electrodes examined were 1.70,1.94,2.05,and 2.18,while their corresponding through-plane tortuosities were 4.74,6.94,8.19,and 9.80.In-operando X-ray diffraction and differential electrochemical mass spectrometry were employed to investigate the charge storage mechanism and gas evolution.The study revealed that while graphite electrode tortuosity impacted the amount of Li present in the lithiated graphite phase due to diffusion constraints,it did not affect gas generation.The Li-ion utilization in low-tortuosity electrodes was higher than that in high-tortuosity electrodes because of solid-diffusion limitations.Additionally,the galvanostatic intermittent titration technique(GITT) was employed to investigate a lithium-ion diffusion coefficient.Our results indicate that the lithium-ion diffusion coefficient exhibits a significant difference only during LiC_(6) phase transition.We also observed that the use of a lower tortuosity electrode leads to improved lithium-ion insertion.Consequently,graphite utilization is influenced by the porous electrode design.Safety tests adhering to UN38.3 guidelines verified battery safety.The study demonstrated the practical application of optimized NCA90 LIB cells with diverse graphite electrode tortuosities in a high-performance Lamborghini GoKart,paving the way for further advancements in Ni-rich LIB technology.展开更多
Based on spectrum principle and analyzing the infrared absorption spectrum ofmethane, a kind of optical fiber methane gas sensor and its system are developed. DFBLD(Distributedfeedback laser diode) in 1 300 nm waveban...Based on spectrum principle and analyzing the infrared absorption spectrum ofmethane, a kind of optical fiber methane gas sensor and its system are developed. DFBLD(Distributedfeedback laser diode) in 1 300 nm waveband is used as illuminant and phase-detecting technology isused to carry out harmonic wave detecting the concentration of methane. The sensitivity can arriveat 10^(-5). Experiments results show that the performance targets of the sensor such as sensitivitycan basically satisfy the requests of methane detection.展开更多
基金Supported by the National Natural Science Foundation of China(51474184)the Natural Science Foundation of the State Administration of Work Safety in China(2012-387,Sichuan-0021-2016AQ)
文摘Hazardous gas detection systems play an important role in preventing catastrophic gas-related accidents in process industries. Even though effective detection technology currently exists for hazardous gas releases and a majority of process installations have a large number of sensitive detectors in place, the actual operating performance of gas detection systems still does not meet the expected requirements. In this paper, a riskbased methodology is proposed to optimize the placement of hazardous gas detectors. The methodology includes three main steps, namely, the establishment of representative leak scenarios, computational fluid dynamics(CFD)-based gas dispersion modeling, and the establishment of an optimized solution. Based on the combination of gas leak probability and joint distribution probability of wind velocity and wind direction, a quantitative filtering approach is presented to select representative leak scenarios from all potential scenarios. The commercial code ANSYS-FLUENT is used to estimate the consequence of hazardous gas dispersions under various leak and environmental conditions. A stochastic mixed-integer linear programming formulation with the objective of minimizing the total leak risk across all representative leak scenarios is proposed, and the greedy dropping heuristic algorithm(GDHA) is used to solve the optimization model. Finally, a practical application of the methodology is performed to validate its effectiveness for the optimal design of a gas detector system in a high-sulfur natural gas purification plant in Chongqing, China. The results show that an appropriate number of gas detectors with optimal cost-effectiveness can be obtained, and the total leak risk across all potential scenarios can be substantially reduced. This methodology provides an effective approach to guide the optimal placement of pointtype gas detection systems involved with either single or mixed gas releases.
文摘In this study, we tried to develop the in situ coating methods of hydrophilic polymer solution containing water soluble dye on nonwoven sheet for the colorimetric film sensor. And color change of coated dye according to contact various gas samples (as strong acid and base, chloroform, ammonia and HF) of this dye-coated nonwoven film was examined for the application of chemically toxic materials detecting tools in the actual site of working place without aid of any kinds of detecting devices. By the addition of electron transfer agent (quinone derivatives), quick color change behaviors were observed within 10 seconds under the contact of various toxic gases in general condition(room temperature, 50% humidity).
基金supported by the National Natural Science Foundation of China under Grant No. 60577013the New Century Support Program for Talented Young Teachers in Universities under Grant No. NCET-04-0241
文摘Wavelength sweep technique (WST) is introduced into intra-cavity fiber laser (ICFL) for low concentration gas detection. The limitation induced by noise can be eliminated using this method, and the performance of the system is improved. The sensitivity of the system is reduced to less than 300 ppm. With WST, sweeping characteristic of the ICFL can be described according to known gas absorption spectra.
基金This work was supported by the High-end Foreign Experts Introduction Plan(No.G2021003003L)the Hebei Province Introduced Foreign Intelligence Projects(No.2022-18).
文摘Effective methods are urgently required to optimize Raman spectroscopy technology to ameliorate its low detection sensitivity.Here,we superposed two near-concentric cavities to develop a dual near-concentric cavities group(DNCCG)to assess its effect on gas Raman signal intensity,signal-to-noise ratio(SNR),and limit of detection(LOD).The results showed that DNCCG generally had higher CO_(2) Raman signal intensity than the sum of two near-concentric cavities.Meanwhile,the noise intensity of DNCCG was not enhanced by the superposition of near-concentric cavities.Accordingly,DNCCG increased the SNR.The LOD for CO_(2) was 24.6 parts per million.DNCCG could be an effective method to improve the detection capability of trace gases and broaden the dynamic detection range,which might aid the future development of innovative technology for multicomponent gas detection.
基金funded by Science-Technology Development Plan Project of Jilin Province,20210203099SF,Zhiyong ChangScience and Technology Development Project of Jilin Province,20190303061SF,Yongming Yao13th Five-Year Plan Scientific Research Foundation of the Education Department of Jilin Province,JJKH20190190KJ,Zhiyong Chang.
文摘Over the past decades,membrane-based separation processes have found numerous applications in various industries.Membrane contactor is an important part of the separation of dissolved gas in the early stage of gas detection.In this paper,to improve efficiency in the detection of the dissolved gas phase in seawater,a better flat membrane contactor is proposed to achieve efficient degassing,inspired by the way fish breathe underwater and the special structure of fish gills.The bioinspired flow channel structures in the flat membrane contactor are suggested along with the distribution of internal blood vessels in the gill platelet and the feature of the gill platelet surface.Using 3D printing,the special degassing devices are manufactured,and comparative analysis of relevant flow parameters is made using different flow channels,combined with the CFD simulation.The final result showed that the proposed flow channel in the degasser achieves a better degassing effect compared with conventional flow channel when the membrane contact area is limited,which can provide good conditions for subsequent gas detection.
基金The work at Wayne State University and the Pacific Northwest National Laboratory was supported by the U.S.Department of Energy(DOE),Office of Science,Office of Basic Energy Sciences,through Award#78705In addition,L.L.and X.G.acknowledge support from National Science Foundation under award CHE-1943737.L.Z.and S.W.L.acknowledge support from the National Natural Science Foundation of China(No.22103047)Hefei National Laboratory for Physical Sciences at the Microscale(No.KF2020107).
文摘Here,we report a Pd/PdO_(x) sensing material that achieves 1-s detection of 4% H_(2) gas(i.e.,the lower explosive limit concentration for H_(2))at room temperature in air.The Pd/PdO_(x) material is a network of interconnected nanoscopic domains of Pd,PdO,and PdO_(2).Upon exposure to 4% H_(2),PdO and PdO_(2) in the Pd/PdO_(x) are immediately reduced to metallic Pd,generating over a>90% drop in electrical resistance.The mechanistic study reveals that the Pd/PdO_(2) interface in Pd/PdOx is responsible for the ultrafast PdO_(x) reduction.Metallic Pd at the Pd/PdO_(2) interface enables fast H_(2) dissociation to adsorbed H atoms,significantly lowering the PdO2 reduction barrier.In addition,control experiments suggest that the interconnectivity of Pd,PdO,and PdO2 in our Pd/PdO_(x) sensing material further facilitates the reduction of PdO,which would otherwise not occur.The 1-s response time of Pd/PdO_(x) under ambient conditions makes it an excellent alarm for the timely detection of hydrogen gas leaks.
基金This work was supported by the Key Scientific and Technological Research and Development Projects in Jilin Province (Grant No. 20180201038GX), Jilin Province Development and Reform Commission (Grant Nos. 2016C029 and 2017C051-3), the Education Department of Jilin Province (Grant Nos. [2015] 490, JJKH20170791K J, JJKH20170812KJ and 20150520075 JH) and the China Postdoctoral Science Foundation (Grant No. 2016M601383).
文摘In this paper, a miniaturized bionic electronic nose system is developed in order to solve the problems arising in oil and gas detection for large size and inflexible operation in downhole. The bionic electronic nose chamber is designed by mimicking human nasal turbinate structure, V-groove structure on shark skin surface and flow field distribution around skin surface. The sensitivity of the bionic electronic nose system is investigated through experimentation. Radial Basis Function (RBF) and Support Vector Machines (SVM) of 10-fold cross validation are used to compare the recognition performance of the bionic electronic nose system and common one. The results show that the sensitivity of the bionic electronic nose system with bionic composite chamber (chamber B) is significantly improved compared with that with common chamber (chamber A). The recognition rate of chamber B is 4.27% higher than that of chamber A for the RBF algorithm, while for the SVM algorithm, the recognition rate of chamber B is 5.69% higher than that of chamber A. The three-dimensional simulation model of the chamber is built and verified by Computational Fluid Dynamics (CFD) simulation analysis. The number of vortices in chamber B is fewer than that in chamber A. The airflow velocity near the sensors inside chamber B is slower than that inside chamber A. The vortex intensity near the sensors in chamber B is 2.27 times as much as that in chamber A, which facilitates gas molecules to fully contact with the sensor surface and increases the intensity of sensor signal, and the contact strength and time between odorant molecules and sensor surface. Based on the theoretical investigation and test validation, it is believed that the proposed bionic electronic nose system with bionic composite chamber has potential for oil and gas detection in downhole.
基金This work is supported by the RIE Advanced Manufacturing and Engineering(AME)Programmatic Grant Project(Grant A18A5b0056,WBS:A-0005117-02-00)the Advanced Research and Technology Innovation Centre(ARTIC)Project(WBS:A-0005947-20-00)the Ministry of Education(MOE)of Singapore Tier 1 Project(WBS:A-0005138-01-00).
文摘Metal-organic frameworks(MOFs)have been extensively used for gas sorption,storage and separation owing to ultrahigh porosity,exceptional thermal stability,and wide structural diversity.However,when it comes to ultra-low concentration gas detection,technical bottlenecks of MOFs appear due to the poor adsorption capacity at ppm-/ppblevel concentration and the limited sensitivity for signal transduction.Here,we present hybrid MOF-polymer physi-chemisorption mechanisms integrated with infrared(IR)nanoantennas for highly selective and ultrasensitive CO_(2) detection.To improve the adsorption capacity for trace amounts of gas molecules,MOFs are decorated with amino groups to introduce the chemisorption while maintaining the structural integrity for physisorption.Additionally,leveraging all major optimization methods,a multi-hotspot strategy is proposed to improve the sensitivity of nanoantennas by enhancing the near field and engineering the radiative and absorptive loss.As a benefit,we demonstrate the competitive advantages of our strategy against the state-of-the-art miniaturized IR CO_(2) sensors,including low detection limit,high sensitivity(0.18%/ppm),excellent reversibility(variation within 2%),and high selectivity(against C_(2)H_(5)OH,CH_(3)OH,N_(2)).This work provides valuable insights into the integration of advanced porous materials and nanophotonic devices,which can be further adopted in ultra-low concentration gas monitoring in industry and environmental applications.
基金supported by the National Key R&D Program of China(No.2017YFB0405301)。
文摘We report a 1.65μm square-Fabry–Pérot[FP]coupled cavity semiconductor laser for methane gas detection.The laser output optical power can reach 7.4 m W with the side mode suppression ratio about 40 d B.The wavelength tuning range is 2 nm by adjusting the FP cavity injection current,covering the methane absorption line at 1653.72 nm.The lasing wavelength can also be tuned by adjusting the square microcavity injection current or temperature,respectively.Methane gas detection is successfully demonstrated utilizing this laser.
基金support for this work provided by the Fundamental Research Funds for the Central Universities(China University of Mining & Technology) (No. 2010ZDP02B02)the State Key Laboratory of Coal Resources and Safe Mining(No. SKLCRSM08X02)
文摘Based on radon gas properties and its existing projects applications, we firstly attempted to apply geo- physical and chemical properties of radon gas in the field of mining engineering, and imported radioac- tive measurement method to detect the development process of the overlying strata mining-induced fractures and their contained water quality in underground coal mining, which not only innovates a more simple-fast-reliable detection method, but also further expands the applications of radon gas detection technology in mining field. A 3D simulation design of comprehensive testing system for detecting strata mining-induced fractures on surface with radon gas (CTSR) was carried out by using a large-scale 3D solid model design software Pro/Engineer (Pro/E), which overcame three main disadvantages of ''static design thought, 2D planar design and heavy workload for remodification design'' on exiting design for mining engineering test systems. Meanwhile, based on the simulation design results of Pro/E software, the sta- bility of the jack-screw pressure bar for the key component in CTSR was checked with a material mechan- ics theory, which provided a reliable basis for materials selection during the latter machining process.
文摘To find a neural network model suitable to identify the concentration of mixed pernicious gases in pig house, the quantitative detection model of pernicious gases in pig house was set up based on BP ( Back propagation) neural network. The BP neural network was trained separately by the three functions, trainbr, traingdm and trainlm, in order to identify the concentration of mixed pernicious gases composed of ammonia gas and hepatic gas. The neural network toolbox in MATLAB software was used to simulate the detection. The results showed that the neural network trained by trainbr function has high average identification accuracy and faster detection speed, and it is also insensitive to noise; therefore, it is suitable to identify the concentration of pemidous gases in pig house. These data provide a reference for intelligent monitoring of pemicious gases in pigsty.
基金Supported by Natural Science Foundation of China(51991363)National Program on Key Basic Research Project(973 Program)(2015CB251200)Changjiang Scholars and Innovative Research Team Project(IRT_14R58)
文摘The feasibility of gas kick early detection outside the riser was analyzed based on gas-liquid multiphase flow theory.Then an experimental platform for gas kick early detection based on Doppler ultrasonic wave was established and the propagation experiments in two-phase flow of gas-water(sucrose solutions)were conducted.The time and frequency domains of the Doppler ultrasonic wave signals during the experiments were analyzed.The results show that:(1)No matter the pump was on or off,the detected average Doppler ultrasonic signal voltage increased first and then decreased with the increase of the gas void fraction,and had a quadratic function relation with gas void fraction,so the average voltage change of the monitored signals can be used to deduce the approximate gas void fraction.The Doppler ultrasonic wave signal voltage was significantly reduced in magnitude and variation in the solution with higher viscosity,and the viscosity has stronger impact on the magnitude of signal than density.(2)When the pump was stopped,the Doppler shift increased with the increase of gas void fraction,and the two showed a nearly linear relation,so the detected amount of Doppler shift can reflect the variation of gas void fraction quantitatively.When the pump was on,the sound energy produced by frequency converter had a more significant impact on amplitude spectrum than gas void fraction,so it is impossible to determine whether gas kick occurs by frequency domain signal analysis.(3)This method is a non-contact measurement,with no contact with the drilling fluid and no disruption to the drilling operation.It can quantitatively characterize the gas void fraction according to the change of Doppler ultrasonic signal,enabling earlier detection of gas kick.
文摘Ⅰ The Indexes of Detecting Oil and Gas Resources The deeply buried reservoir which in a dynamic equilibrium state has a great pressure inside, and between it and earth surface there is a great difference of pressure. Therefore the hydrocarbon must spread and move vertically to the surface along the pressure gradient orientation. Hydrocarbons in the reservoir along some small rifts, cracks, joints and cleavages penetrate the overlying strata and seepage onto the surface. Thus the hydrocarbons become unvisble oil and gas signs. This process is called the phenomena of hydrocarbon microseepage of reservoir. Hydrocarbons microseepage in the process
文摘Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly.
基金supported by the National Key Technologies R & D Program of China during the 14th Five-Year Plan period (No. 2021YFD1700904)Henan Provincial Important Project (No. 221100320200)+1 种基金State Key Laboratory of Wheat and Maize Crap Science (No. SKL2023ZZ09)the Henan Center for Outstanding Overseas Scientists (No. GZS2021007)。
文摘Electronic nose(eNose) is a modern bioelectronic sensor for monitoring biological processes that convert CO_(2) into valueadded products, such as products formed during photosynthesis and microbial fermentation. eNose technology uses an array of sensors to detect and quantify gases, including CO_(2), in the air. This study briefly introduces the concept of eNose technology and potential applications thereof in monitoring CO_(2) conversion processes. It also provides background information on biological CO_(2) conversion processes. Furthermore, the working principles of eNose technology vis-à-vis gas detection are discussed along with its advantages and limitations versus traditional monitoring methods. This study also provides case studies that have used this technology for monitoring biological CO_(2) conversion processes. eNose-predicted measurements were observed to be completely aligned with biological parameters for R~2 values of 0.864, 0.808, 0.802, and 0.948. We test eNose technology in a variety of biological settings, such as algae farms or bioreactors, to determine its effectiveness in monitoring CO_(2) conversion processes. We also explore the potential benefits of employing this technology vis-à-vis monitoring biological CO_(2) conversion processes, such as increased reaction efficiency and reduced costs versus traditional monitoring methods. Moreover, future directions and challenges of using this technology in CO_(2) capture and conversion have been discussed. Overall, we believe this study would contribute to developing new and innovative methods for monitoring biological CO_(2) conversion processes and mitigating climate change.
基金supported by the Project Grant from Heilongjiang Bayi Agricultural Reclamation University,Heilongjiang,China (No.XDB201813)。
文摘High-precision methane gas detection is of great importance in industrial safety, energy production and environmental protection, etc. However, in the existing measurement techniques, the methane gas concentration information is susceptible to noise, which leads to its useful signal being drowned by noise. A fusion algorithm of variational modal decomposition(VMD) and improved wavelet threshold filtering is proposed, which is used in combination with tunable diode laser absorption spectroscopy(TDLAS) to implement a non-contact, high-resolution methane gas concentration detection. The fusion algorithm can perform noise reduction and further segmentation of the methane gas detection signal. And the simulation and experiment verify the effectiveness of the fusion algorithm, and the experimental results show that for the detection of air containing 10 ppm, 30 ppm, 60 ppm, 80 ppm, and 99 ppm methane, the errors are 12.75%, 8.18%, 3.37%, 2.46%, and 1.78%, respectively.
基金supported by the National Natural Science Foundation of China under Grant No. 60577013the New Century Support Program for Talented Young Teachers in Universities, MOE (Ministry of Education of China), China
文摘Wavelength modulation technique (WMT) and wavelength sweep technique (WST) are introduced into intra-cavity absorption gas sensors (ICAGS) for low concentration gas detection. The optimized parameters of the system maximizing the signal-to-noise ratio (SNR) are found. Calibration of acetylene concentration and gas recognition are both realized.
文摘Photoacoustic spectroscopy was used to test the photoacoustic properties of sulfur hexafluoride, an optically thick and potent greenhouse gas. While exploring the photoacoustic effect of sulfur hexafluoride, the effects of the position of the microphone within a gas cell were determined. Using a 35 cm gas cell, microphones were positioned at 17.5 cm, the middle of the gas cell, 12.5 cm, 7.5 cm, and 2.5 cm from the window of the cell. From the photoacoustic signal produced for each resonance frequency at each microphone position, the effects of acoustic pressure produced at each position on the signal recorded were observed. This is the first study done by experimentation with the photoacoustic effect to show that standing waves have different amplitudes at different microphone positions.
基金financially supported under the Program Management Unit for National Competitiveness Enhancement (PMUC) by the Office of the National Higher Education Science Research and Innovation Policy Council (NXPO) PTT Public Company LimitedIRPC Public Company Limited, Thailand Science Research and Innovation (TSRI) under the Fundamental Fund by TSRI (FRB660004/0457)+2 种基金Vidyasirimedhi Institute of Science and Technology (VISTEC)Energy Policy and Planning Office (EPPO), Ministry of Energy, Thailandthe Frontier Research Centre (FRC) supported this work, VISTEC。
文摘This study explored the complex effect of graphite tortuosity on the electrochemical performance of Ni-rich NCA90 Li-ion batteries(LIBs).Different levels of graphite anode tortuosity were analyzed,revealing that low-tortuosity electrodes had better graphite utilization.The in-plane tortuosities of the graphite anode electrodes examined were 1.70,1.94,2.05,and 2.18,while their corresponding through-plane tortuosities were 4.74,6.94,8.19,and 9.80.In-operando X-ray diffraction and differential electrochemical mass spectrometry were employed to investigate the charge storage mechanism and gas evolution.The study revealed that while graphite electrode tortuosity impacted the amount of Li present in the lithiated graphite phase due to diffusion constraints,it did not affect gas generation.The Li-ion utilization in low-tortuosity electrodes was higher than that in high-tortuosity electrodes because of solid-diffusion limitations.Additionally,the galvanostatic intermittent titration technique(GITT) was employed to investigate a lithium-ion diffusion coefficient.Our results indicate that the lithium-ion diffusion coefficient exhibits a significant difference only during LiC_(6) phase transition.We also observed that the use of a lower tortuosity electrode leads to improved lithium-ion insertion.Consequently,graphite utilization is influenced by the porous electrode design.Safety tests adhering to UN38.3 guidelines verified battery safety.The study demonstrated the practical application of optimized NCA90 LIB cells with diverse graphite electrode tortuosities in a high-performance Lamborghini GoKart,paving the way for further advancements in Ni-rich LIB technology.
文摘Based on spectrum principle and analyzing the infrared absorption spectrum ofmethane, a kind of optical fiber methane gas sensor and its system are developed. DFBLD(Distributedfeedback laser diode) in 1 300 nm waveband is used as illuminant and phase-detecting technology isused to carry out harmonic wave detecting the concentration of methane. The sensitivity can arriveat 10^(-5). Experiments results show that the performance targets of the sensor such as sensitivitycan basically satisfy the requests of methane detection.