A quantum cascade laser(QCL) based system for simultaneous detection of CO and CO_2 is developed.The QCL can scan over two neighboring CO(2055.40 cm^(-1)) and CO_2(2055.16 cm^(-1)) lines with a single curren...A quantum cascade laser(QCL) based system for simultaneous detection of CO and CO_2 is developed.The QCL can scan over two neighboring CO(2055.40 cm^(-1)) and CO_2(2055.16 cm^(-1)) lines with a single current scan.The wavelength modulation spectroscopy( f = 20 k Hz) is utilized to enhance the signal-to-noise ratio.A white cell with an effective optical path length of 74 m is used.The calibration of the sensor is performed and minimum detection limits of 1.3 ppb(1 × 10^(-9))for CO and 0.44 ppm(1 × 10^(-6)) for CO_2 are achieved.展开更多
基金Project supported by the National Key Scientific Instrument and Equipment Development Project of China(Grnat No.2014YQ060537)the National Basic Research Program of China(Grant No.2013CB632803)+1 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDA05040102)the National Natural Science Foundation of China(Grant No.41405134)
文摘A quantum cascade laser(QCL) based system for simultaneous detection of CO and CO_2 is developed.The QCL can scan over two neighboring CO(2055.40 cm^(-1)) and CO_2(2055.16 cm^(-1)) lines with a single current scan.The wavelength modulation spectroscopy( f = 20 k Hz) is utilized to enhance the signal-to-noise ratio.A white cell with an effective optical path length of 74 m is used.The calibration of the sensor is performed and minimum detection limits of 1.3 ppb(1 × 10^(-9))for CO and 0.44 ppm(1 × 10^(-6)) for CO_2 are achieved.