AIM:To observe the clinical efficacy of the combined use of small incision lenticule extraction(SMILE)-derived lenticule patches in corneal dermoid excision,with fixation of the lenticule patches assisted by fibrin gl...AIM:To observe the clinical efficacy of the combined use of small incision lenticule extraction(SMILE)-derived lenticule patches in corneal dermoid excision,with fixation of the lenticule patches assisted by fibrin glue.METHODS:Seventeen eyes of 17 patients with corneal dermoid were treated with dermoid removal combined with SMILE-derived lenticule transplantation.All lenticule patches were fixed by fibrin glue.Ocular changes were assessed using slit lamp microscopy and anterior-segmental optical coherence tomography.The best-corrected visual acuity(BCVA)and ocular dioptric variations were examined preoperatively and postoperatively.Intraocular pressure(IOP)was also monitored in all visited time.RESULTS:Totally,18 lenticule patches were used on 17 eyes of 17 cornea dermoid patients.The mean follow-up time was 11.47±5.28mo.All lenticule patches we resuccessfullyg lued,kept on its location and maintained transparent during the follow-up time,with a consecutive epithelial cover for 1wk.Nine of the patients could coordinate visual and optometry exam well.Their preoperative BCVA is 0.60±0.35 in decimal,significantly improved to 0.80±0.26 in decimal at 6mo postoperatively(Z=-2.392,P=0.017),but the changes of their corneal astigmatism diopters showed no significance,with 2.22±1.91 D preoperatively,and 2.28±1.31 D at 6mo postoperatively(Z=-0.135,P=0.893).Limbal pannus formation occurred in 4(23.52%)cases and decreased with the application of tacrolimus eyedrops.IOP increased in 2(11.76%)cases,but well decreased by timolol maleate eyedrops.All the adult patients or guardians of minor patients were satisfied with the cosmetic improvement.CONCLUSION:Dermoid excision combined with transplantation of SMILE-derived lenticule patches using fibrin glue is a safe and effective novel tectonic keratoplasty procedure for corneal dermoid.展开更多
Fibrin glue is widely used in clinical practice and plays an important role in reducing postoperative complications.We report a case of a 65-year-old man, whose common bile duct was injured by fibrin glue, with a hist...Fibrin glue is widely used in clinical practice and plays an important role in reducing postoperative complications.We report a case of a 65-year-old man, whose common bile duct was injured by fibrin glue, with a history of failed laparoscopic cholecystectomy and open operation for uncontrolled laparoscopic bleeding.In view of thepersistent liver dysfunction, xanthochromia and skin itching, the patient was admitted to us for further management.Ultrasound, computed tomography, and magnetic resonance cholangiopancreatography(MRCP) revealed multiple stones in the common bile duct, and liver function tests confirmed the presence of obstructive jaundice and liver damage.Endoscopic retrograde cholangiopancreatography was unsuccessfully performed to remove choledocholithiasis, but a small amount of tissue was removed and pathologically confirmed as calcified biliary mucosa.This was followed by open surgery for suspicious cholangiocarcinoma.There was no evidence of cholangiocarcinoma, but the common bile duct wall had a defect of 8 mm × 10 mm at Calot's triangle.A hard, grid-like foreign body was removed, which proved to be solid fibrin glue.Subsequently, the residual choledocholithiasis was removed by a choledochoscopic procedure, and the common bile duct deletion was repaired by liver round ligament with T-tube drainage.Six months later, endoscopy was performed through the T-tube fistula and showed a well-repaired bile duct wall.Eight months later, MRCP confirmed no bile duct stenosis.A review of reported cases showed that fibrin glue is widely used in surgery, but it can also cause organ damage.Its mechanism may be related to discharge reactions.展开更多
AIM: To investigate whether the routine use of fibrin glue applied onto the hepatic resection area can diminish postoperative volume of bloody or biliary fluids drained via intraoperatively placed perihepatic tubes an...AIM: To investigate whether the routine use of fibrin glue applied onto the hepatic resection area can diminish postoperative volume of bloody or biliary fluids drained via intraoperatively placed perihepatic tubes and can thus lower the complication rate.METHODS: Two groups of consecutive patients with a comparable spectrum of recent hepatic resections were compared: (1) 13 patients who underwent application of fibrin glue immediately after resection of liver parenchyma;(2) 12 patients who did not. Volumes of postoperative drainage fluid were determined in 4-h intervals through 24 h indicating the intervention caused bloody and biliary segregation.RESULTS: Through the first 8 h postoperatively, there was a tendency of higher amounts of fluids in patients with no additional application of fibrin glue while through the following intervals, a significant increase of drainage volumes was documented in comparison with the first two 4-h intervals, e.g., after 12 h, 149.6 mL +/-110 mL vs 63.2 mL +/-78 mL. Using fibrin glue, postoperative fluid amounts were significantly lower through the postoperative observation period of 24 h (851 mL +/-715 mL vs 315 mL +/-305 mL).CONCLUSION: For hepatic resections, the use of fibrin glue appears to be advantageous in terms of a significant decrease of surgically associated segregation of blood or bile out of the resection area. This might result in a better outcome.展开更多
We report a case of a 63-year-old male who experienced an iatrogenic sigmoid perforation repaired combining three endoscopic techniques.The lesion was large and irregular with three discrete perforations,therefore,we ...We report a case of a 63-year-old male who experienced an iatrogenic sigmoid perforation repaired combining three endoscopic techniques.The lesion was large and irregular with three discrete perforations,therefore,we decided to close it by placing one clip per perforation,and then connecting all the clips with two endoloops.Finally we chose to use a fibrin glue injection to obtain a complete sealing.Four days after the colonoscopy the patient underwent a laparoscopic right hemicolectomy due to evidence of a large polyp of the caecum with high grade dysplasia and focal carcinoma in situ.Inspection of the sigma showed complete repair of the perforation.This report underlines how a conservative approach,together with a combination of various endoscopic techniques,can resolve complicated iatrogenic perforations of the colon.展开更多
Summary: By culturing bone marrow mesenchymal stem cells of rabbits with fibrin glue in vitro, the biocompatibility of fibrin glue was investigated to study whether this material can be used as scaffolds in bone tissu...Summary: By culturing bone marrow mesenchymal stem cells of rabbits with fibrin glue in vitro, the biocompatibility of fibrin glue was investigated to study whether this material can be used as scaffolds in bone tissue engineering. After 2-months old New Zealand rabbits had been anesthetized, about 4-6 ml of bone marrow were aspirated from rabbit femoral trochanter. The monocytes suspension was aspirated after bone marrow was centrifuged with lymphocyte separating medium and cultured primarily. Then the cells were divided into two groups: one was cultured with complete medium and the other with induced medium. The cells of the two groups were collected and inoculated to the culture plate containing fibrin glue. In the control group, cells were inoculated without fibrin glue. The implanted cells and materials were observed at different stages under a phase-contrast microscope and scanning electron microscope. MTT and alkaline phosphatase (ALP) were measured. Bone marrow mesenchymal stem cells grew on the surface of fibrin glue and adhered to it gradually. Cells light absorption value (A value) and the ALP content showed no significant difference. Fibrin glue had no inhibitory effect on cell morphology, growth, proliferation and differentiation. It has good biocompatibility and can be used as scaffold materials for bone marrow mesenchymal stem cells in bone tissue engineering.展开更多
Improving the closure effect of surgical suture for repair of annulus fibrosus defects remains an unsolved problem.A new type of porcine fibrin glue was reported for the repair of annulus fibrous defects in sheep mode...Improving the closure effect of surgical suture for repair of annulus fibrosus defects remains an unsolved problem.A new type of porcine fibrin glue was reported for the repair of annulus fibrous defects in sheep models in this study.Continuous axial loading test showed that this glue could effectively improve the closure effect of surgical suture for annulus fibrous defect.Magnetic resonance imaging (MRI) of the lumbar spine confirmed that,compared with nonfibrin glue treated intervertebral discs,it contributed to preservation of the nucleus pulposus and maintained the physiological hydration of the intervertebral discs.Moreover,histomorphology evaluation showed that the porcine fibrin glue could partially reverse degeneration of the injured intervertebral discs.Taken together,porcine fibrin glue can effectively enhance the closure effect of surgical suture on annulus fibrosus,improve the repair effect and slow down the degeneration of the intervertebral disc,and provide a potential therapeutic strategy for degenerative intervertebral disc disease.展开更多
Transgastric endoscopic necrosectomy has been recently introduced as the effective and alternative management of infected pancreatic necrosis and pancreatic abscess. However,up to 40% of patients who undergo endoscopi...Transgastric endoscopic necrosectomy has been recently introduced as the effective and alternative management of infected pancreatic necrosis and pancreatic abscess. However,up to 40% of patients who undergo endoscopic necrosectomy may need an additional percutaneous approach for subsequent peripancreatic fluid collection or non-resolution of pancreatic necrosis. This percutaneous approach may lead to persistent pancreatocutaneous fistula,which remains a serious problem and usually requires prolonged hospitalization,or even open-abdominal surgery. We describe the first case of pancreatocutaneous fistula and concomitant abdominal wall defect following transgastric endoscopic necrosectomy and percutaneous drainage,which were endoscopically closed with fibrin glue injection via the necrotic cavity.展开更多
Microsurgical suturing is the gold standard of nerve coaptation. Although literature on the usefulness of fibrin glue as an alternative is becoming increasingly available, it remains contradictory. Furthermore, no dat...Microsurgical suturing is the gold standard of nerve coaptation. Although literature on the usefulness of fibrin glue as an alternative is becoming increasingly available, it remains contradictory. Furthermore, no data exist on how both repair methods might influence the morphological aspects(arborization; branching) of early peripheral nerve regeneration. We used the sciatic nerve transplantation model in thy-1 yellow fluorescent protein mice(YFP; n = 10). Pieces of nerve(1cm) were grafted from YFP-negative mice(n = 10) into those expressing YFP. We performed microsuture coaptations on one side and used fibrin glue for repair on the contralateral side. Seven days after grafting, the regeneration distance, the percentage of regenerating and arborizing axons, the number of branches per axon, the coaptation failure rate, the gap size at the repair site and the time needed for surgical repair were all investigated. Fibrin glue repair resulted in regenerating axons travelling further into the distal nerve. It also increased the percentage of arborizing axons. No coaptation failure was detected. Gap sizes were comparable in both groups. Fibrin glue significantly reduced surgical repair time. The increase in regeneration distance, even after the short period of time, is in line with the results of others that showed faster axonal regeneration after fibrin glue repair. The increase in arborizing axons could be another explanation for better functional and electrophysiological results after fibrin glue repair. Fibrin glue nerve coaptation seems to be a promising alternative to microsuture repair.展开更多
Chylous ascites, an uncommon disease usually caused by obstruction or rupture of the peritoneal or retroperitoneal lymphatic glands, is defined as the accumulation of chyle in the peritoneal cavity. It is a difficult ...Chylous ascites, an uncommon disease usually caused by obstruction or rupture of the peritoneal or retroperitoneal lymphatic glands, is defined as the accumulation of chyle in the peritoneal cavity. It is a difficult management problem due to the serious mechanical, nutritional, and immunological consequences of the constant loss of protein and lymphocytes. Most investigators believe that the incidence of chylous ascites is increasing because of more aggressive thoracic and retroperitoneal surgery and also because of the prolonged survival of patients with cancer. Although the incidence of chylous ascites has increased in recent years, treatment remains unsatisfactory. The standard conservative treatments include paracentesis, a medium chain triglyceride (MCT) based diet, total parenteral nutrition (TPN), and recently recommended somatostatin, are preferable in most cases, but usually need several weeks to cure chyloperitonum. Open or laparoscopic ligation of ruptured lymph ducts, a commonly used procedure for persistent chylous ascites, may fail in patients without visible chylous leak. Fibrin glue, a widely used approach to treat various kinds of fistulae, has recently been reported to seal chylous leak during operation. Here we present two cases of chylous ascites who were successfully treated with fibrin glue in different settings.展开更多
Background Placement of an external support has been reported to prevent intimal hyperplasia of vein grafts. However, it is limited by potential complications. In the present study, we investigated the effect of fibri...Background Placement of an external support has been reported to prevent intimal hyperplasia of vein grafts. However, it is limited by potential complications. In the present study, we investigated the effect of fibrin glue on preventing vein graft failure as perivenous application. Methods Twenty-four rabbits were divided into non-supported group (n=12) and fibrin glue group (n=12). All animals underwent unilateral jugular vein into common carotid artery interposition grafting and then fibrin glue was applied as perivenous support. Samples of tissues were harvested after 4 weeks. Results The vein grafts with fibrin glue demonstrated a statistically significant decrease in proliferating cell nuclear antigen in the medial/intimal region [13.38% (11.26%-15.11%)] compared with non-supported vein grafts [31.22% (27.15%-35.98%)] (P〈0.001). Light microscopy showed remarkable attenuation of endothelial cell loss and numerous microvessels in neoadventitia in the fibrin glue group compared with the non-supported group. The smooth muscle cells migrated into adventitia significantly in fibrin glue group, whereas the smooth muscle ceils migrated into intima in non-supported group. Conclusion Perivenous support of vein graft with fibrin glue in vivo can attenuate the severe injury encountered in the non-supported vein grafts exposed to artery.展开更多
Background The clinical applications of fibrin glue span over several surgical modalities.The aim of this study was to evaluate the biocompatibility and biodegradation of different formulations of platelet-rich fibrin...Background The clinical applications of fibrin glue span over several surgical modalities.The aim of this study was to evaluate the biocompatibility and biodegradation of different formulations of platelet-rich fibrin glue in vivo and examine its effects on the neovascularization of wound sites.Methods Human-derived single-unit fibrin glue was prepared.Incisions were made on the backs of rats,and these were coated with homemade glues containing different concentrations of aminomethylbenzoic acid (Groups A-F) or commercial adhesives (Group G).A sham control group was included (Group H).The wounds were examined by histological analysis and immunohistochemistry at several time points.Results Successful wound closure was achieved in all groups by day 12.Acute inflammation occurred during the first six days,but gradually disappeared.The longest sealant duration was achieved using the lowest concentration of antifibrinolytic agent in a 1:10 volume ratio with cryoprecipitate.Expression levels of the platelet endothelial cell adhesion molecule-1 were significantly higher in Groups A and C compared to the control groups (Groups G and H) on day 3 (P <0.05).Conclusions Single-unit platelet-rich fibrin glue has excellent biocompatibility and is associated with the upregulation of neovascularization.The addition of aminomethylbenzoic acid could prevent the degradation of fibrin glue.展开更多
AIM: To evaluate the outcomes and safety of lamellar keratoplasty(LK) assisted by fibrin glue in corneal perforations. ·METHODS: Six eyes of 6 patients affected by different corneal pathologies(2 posttraumatic co...AIM: To evaluate the outcomes and safety of lamellar keratoplasty(LK) assisted by fibrin glue in corneal perforations. ·METHODS: Six eyes of 6 patients affected by different corneal pathologies(2 posttraumatic corneal scar and 3 bacterial keratitis) underwent LK procedures by using fibrin glue. The mean corneal perforation diameter was 1.35 ±0.64mm(range,0.7-2.5mm),and the greatest diameter of the ulcerative stromal defect was 2.47 ± 0.77mm in average(range,1.5-3.5mm). The donor corneal lamella diameters were 0.20-mm larger and thicker than the recipient to restore a physiologic corneal thickness and shape: mean donor diameter was 8.34 ± 0.28mm(range,8.2-8.7mm) and mean thickness was 352±40.27mm(range,220-400mm). Mean follow-up was 7.33±1.97 months(range,6-11 months). Postoperatively,the graft status,graft clarity,anterior chamber response,the visual prognosis,intraocular pressures,and postoperative complications were recorded. ·RESULTS:Allthecornealperforationsweresuccessfully healed after the procedure. The best-corrected visual acuity(BCVA) ranged from 20/1 000 to 20/50 in their initial presentation,and from 20/100 to 20/20 in their last visit,showed increase in all the patients. No major complications such as graft dislocation and graft failure were noted. Neovascularization developed in the superficial stroma of donor graft in 1 case. High intraocular pressure developed on day 2 after surgery,while was remained in normal range after application of anti-glaucomatous eyedrops for 1 week in 1 case. ·CONCLUSION: Fibrin glue-assisted sutureless LK is valuable for maintaining the ocular integrity in the treatment of corneal perforations.展开更多
基金Supported by Science and Technology Planning Project of Guangxi Zhuang Autonomous Region (No.AB18221038)Guangxi Medical&Health Appropriate Technology Development and Promoted Application Project (No.S2021092)。
文摘AIM:To observe the clinical efficacy of the combined use of small incision lenticule extraction(SMILE)-derived lenticule patches in corneal dermoid excision,with fixation of the lenticule patches assisted by fibrin glue.METHODS:Seventeen eyes of 17 patients with corneal dermoid were treated with dermoid removal combined with SMILE-derived lenticule transplantation.All lenticule patches were fixed by fibrin glue.Ocular changes were assessed using slit lamp microscopy and anterior-segmental optical coherence tomography.The best-corrected visual acuity(BCVA)and ocular dioptric variations were examined preoperatively and postoperatively.Intraocular pressure(IOP)was also monitored in all visited time.RESULTS:Totally,18 lenticule patches were used on 17 eyes of 17 cornea dermoid patients.The mean follow-up time was 11.47±5.28mo.All lenticule patches we resuccessfullyg lued,kept on its location and maintained transparent during the follow-up time,with a consecutive epithelial cover for 1wk.Nine of the patients could coordinate visual and optometry exam well.Their preoperative BCVA is 0.60±0.35 in decimal,significantly improved to 0.80±0.26 in decimal at 6mo postoperatively(Z=-2.392,P=0.017),but the changes of their corneal astigmatism diopters showed no significance,with 2.22±1.91 D preoperatively,and 2.28±1.31 D at 6mo postoperatively(Z=-0.135,P=0.893).Limbal pannus formation occurred in 4(23.52%)cases and decreased with the application of tacrolimus eyedrops.IOP increased in 2(11.76%)cases,but well decreased by timolol maleate eyedrops.All the adult patients or guardians of minor patients were satisfied with the cosmetic improvement.CONCLUSION:Dermoid excision combined with transplantation of SMILE-derived lenticule patches using fibrin glue is a safe and effective novel tectonic keratoplasty procedure for corneal dermoid.
文摘Fibrin glue is widely used in clinical practice and plays an important role in reducing postoperative complications.We report a case of a 65-year-old man, whose common bile duct was injured by fibrin glue, with a history of failed laparoscopic cholecystectomy and open operation for uncontrolled laparoscopic bleeding.In view of thepersistent liver dysfunction, xanthochromia and skin itching, the patient was admitted to us for further management.Ultrasound, computed tomography, and magnetic resonance cholangiopancreatography(MRCP) revealed multiple stones in the common bile duct, and liver function tests confirmed the presence of obstructive jaundice and liver damage.Endoscopic retrograde cholangiopancreatography was unsuccessfully performed to remove choledocholithiasis, but a small amount of tissue was removed and pathologically confirmed as calcified biliary mucosa.This was followed by open surgery for suspicious cholangiocarcinoma.There was no evidence of cholangiocarcinoma, but the common bile duct wall had a defect of 8 mm × 10 mm at Calot's triangle.A hard, grid-like foreign body was removed, which proved to be solid fibrin glue.Subsequently, the residual choledocholithiasis was removed by a choledochoscopic procedure, and the common bile duct deletion was repaired by liver round ligament with T-tube drainage.Six months later, endoscopy was performed through the T-tube fistula and showed a well-repaired bile duct wall.Eight months later, MRCP confirmed no bile duct stenosis.A review of reported cases showed that fibrin glue is widely used in surgery, but it can also cause organ damage.Its mechanism may be related to discharge reactions.
文摘AIM: To investigate whether the routine use of fibrin glue applied onto the hepatic resection area can diminish postoperative volume of bloody or biliary fluids drained via intraoperatively placed perihepatic tubes and can thus lower the complication rate.METHODS: Two groups of consecutive patients with a comparable spectrum of recent hepatic resections were compared: (1) 13 patients who underwent application of fibrin glue immediately after resection of liver parenchyma;(2) 12 patients who did not. Volumes of postoperative drainage fluid were determined in 4-h intervals through 24 h indicating the intervention caused bloody and biliary segregation.RESULTS: Through the first 8 h postoperatively, there was a tendency of higher amounts of fluids in patients with no additional application of fibrin glue while through the following intervals, a significant increase of drainage volumes was documented in comparison with the first two 4-h intervals, e.g., after 12 h, 149.6 mL +/-110 mL vs 63.2 mL +/-78 mL. Using fibrin glue, postoperative fluid amounts were significantly lower through the postoperative observation period of 24 h (851 mL +/-715 mL vs 315 mL +/-305 mL).CONCLUSION: For hepatic resections, the use of fibrin glue appears to be advantageous in terms of a significant decrease of surgically associated segregation of blood or bile out of the resection area. This might result in a better outcome.
文摘We report a case of a 63-year-old male who experienced an iatrogenic sigmoid perforation repaired combining three endoscopic techniques.The lesion was large and irregular with three discrete perforations,therefore,we decided to close it by placing one clip per perforation,and then connecting all the clips with two endoloops.Finally we chose to use a fibrin glue injection to obtain a complete sealing.Four days after the colonoscopy the patient underwent a laparoscopic right hemicolectomy due to evidence of a large polyp of the caecum with high grade dysplasia and focal carcinoma in situ.Inspection of the sigma showed complete repair of the perforation.This report underlines how a conservative approach,together with a combination of various endoscopic techniques,can resolve complicated iatrogenic perforations of the colon.
文摘Summary: By culturing bone marrow mesenchymal stem cells of rabbits with fibrin glue in vitro, the biocompatibility of fibrin glue was investigated to study whether this material can be used as scaffolds in bone tissue engineering. After 2-months old New Zealand rabbits had been anesthetized, about 4-6 ml of bone marrow were aspirated from rabbit femoral trochanter. The monocytes suspension was aspirated after bone marrow was centrifuged with lymphocyte separating medium and cultured primarily. Then the cells were divided into two groups: one was cultured with complete medium and the other with induced medium. The cells of the two groups were collected and inoculated to the culture plate containing fibrin glue. In the control group, cells were inoculated without fibrin glue. The implanted cells and materials were observed at different stages under a phase-contrast microscope and scanning electron microscope. MTT and alkaline phosphatase (ALP) were measured. Bone marrow mesenchymal stem cells grew on the surface of fibrin glue and adhered to it gradually. Cells light absorption value (A value) and the ALP content showed no significant difference. Fibrin glue had no inhibitory effect on cell morphology, growth, proliferation and differentiation. It has good biocompatibility and can be used as scaffold materials for bone marrow mesenchymal stem cells in bone tissue engineering.
基金This study was supported by the National Natural Science Foundation of China (No.81260287).
文摘Improving the closure effect of surgical suture for repair of annulus fibrosus defects remains an unsolved problem.A new type of porcine fibrin glue was reported for the repair of annulus fibrous defects in sheep models in this study.Continuous axial loading test showed that this glue could effectively improve the closure effect of surgical suture for annulus fibrous defect.Magnetic resonance imaging (MRI) of the lumbar spine confirmed that,compared with nonfibrin glue treated intervertebral discs,it contributed to preservation of the nucleus pulposus and maintained the physiological hydration of the intervertebral discs.Moreover,histomorphology evaluation showed that the porcine fibrin glue could partially reverse degeneration of the injured intervertebral discs.Taken together,porcine fibrin glue can effectively enhance the closure effect of surgical suture on annulus fibrosus,improve the repair effect and slow down the degeneration of the intervertebral disc,and provide a potential therapeutic strategy for degenerative intervertebral disc disease.
文摘Transgastric endoscopic necrosectomy has been recently introduced as the effective and alternative management of infected pancreatic necrosis and pancreatic abscess. However,up to 40% of patients who undergo endoscopic necrosectomy may need an additional percutaneous approach for subsequent peripancreatic fluid collection or non-resolution of pancreatic necrosis. This percutaneous approach may lead to persistent pancreatocutaneous fistula,which remains a serious problem and usually requires prolonged hospitalization,or even open-abdominal surgery. We describe the first case of pancreatocutaneous fistula and concomitant abdominal wall defect following transgastric endoscopic necrosectomy and percutaneous drainage,which were endoscopically closed with fibrin glue injection via the necrotic cavity.
基金supported by funding from the Charité–Universittsmedizin Berlin
文摘Microsurgical suturing is the gold standard of nerve coaptation. Although literature on the usefulness of fibrin glue as an alternative is becoming increasingly available, it remains contradictory. Furthermore, no data exist on how both repair methods might influence the morphological aspects(arborization; branching) of early peripheral nerve regeneration. We used the sciatic nerve transplantation model in thy-1 yellow fluorescent protein mice(YFP; n = 10). Pieces of nerve(1cm) were grafted from YFP-negative mice(n = 10) into those expressing YFP. We performed microsuture coaptations on one side and used fibrin glue for repair on the contralateral side. Seven days after grafting, the regeneration distance, the percentage of regenerating and arborizing axons, the number of branches per axon, the coaptation failure rate, the gap size at the repair site and the time needed for surgical repair were all investigated. Fibrin glue repair resulted in regenerating axons travelling further into the distal nerve. It also increased the percentage of arborizing axons. No coaptation failure was detected. Gap sizes were comparable in both groups. Fibrin glue significantly reduced surgical repair time. The increase in regeneration distance, even after the short period of time, is in line with the results of others that showed faster axonal regeneration after fibrin glue repair. The increase in arborizing axons could be another explanation for better functional and electrophysiological results after fibrin glue repair. Fibrin glue nerve coaptation seems to be a promising alternative to microsuture repair.
文摘Chylous ascites, an uncommon disease usually caused by obstruction or rupture of the peritoneal or retroperitoneal lymphatic glands, is defined as the accumulation of chyle in the peritoneal cavity. It is a difficult management problem due to the serious mechanical, nutritional, and immunological consequences of the constant loss of protein and lymphocytes. Most investigators believe that the incidence of chylous ascites is increasing because of more aggressive thoracic and retroperitoneal surgery and also because of the prolonged survival of patients with cancer. Although the incidence of chylous ascites has increased in recent years, treatment remains unsatisfactory. The standard conservative treatments include paracentesis, a medium chain triglyceride (MCT) based diet, total parenteral nutrition (TPN), and recently recommended somatostatin, are preferable in most cases, but usually need several weeks to cure chyloperitonum. Open or laparoscopic ligation of ruptured lymph ducts, a commonly used procedure for persistent chylous ascites, may fail in patients without visible chylous leak. Fibrin glue, a widely used approach to treat various kinds of fistulae, has recently been reported to seal chylous leak during operation. Here we present two cases of chylous ascites who were successfully treated with fibrin glue in different settings.
基金This study was supported by National Natural Science Foundation of China (No. 30371408).
文摘Background Placement of an external support has been reported to prevent intimal hyperplasia of vein grafts. However, it is limited by potential complications. In the present study, we investigated the effect of fibrin glue on preventing vein graft failure as perivenous application. Methods Twenty-four rabbits were divided into non-supported group (n=12) and fibrin glue group (n=12). All animals underwent unilateral jugular vein into common carotid artery interposition grafting and then fibrin glue was applied as perivenous support. Samples of tissues were harvested after 4 weeks. Results The vein grafts with fibrin glue demonstrated a statistically significant decrease in proliferating cell nuclear antigen in the medial/intimal region [13.38% (11.26%-15.11%)] compared with non-supported vein grafts [31.22% (27.15%-35.98%)] (P〈0.001). Light microscopy showed remarkable attenuation of endothelial cell loss and numerous microvessels in neoadventitia in the fibrin glue group compared with the non-supported group. The smooth muscle cells migrated into adventitia significantly in fibrin glue group, whereas the smooth muscle ceils migrated into intima in non-supported group. Conclusion Perivenous support of vein graft with fibrin glue in vivo can attenuate the severe injury encountered in the non-supported vein grafts exposed to artery.
基金This work was supported by grants from the Advanced Training Program for Talents,Jiangsu Province,China (No.BRA2011232) and National Natural Science Foundation of China (No.81270478).
文摘Background The clinical applications of fibrin glue span over several surgical modalities.The aim of this study was to evaluate the biocompatibility and biodegradation of different formulations of platelet-rich fibrin glue in vivo and examine its effects on the neovascularization of wound sites.Methods Human-derived single-unit fibrin glue was prepared.Incisions were made on the backs of rats,and these were coated with homemade glues containing different concentrations of aminomethylbenzoic acid (Groups A-F) or commercial adhesives (Group G).A sham control group was included (Group H).The wounds were examined by histological analysis and immunohistochemistry at several time points.Results Successful wound closure was achieved in all groups by day 12.Acute inflammation occurred during the first six days,but gradually disappeared.The longest sealant duration was achieved using the lowest concentration of antifibrinolytic agent in a 1:10 volume ratio with cryoprecipitate.Expression levels of the platelet endothelial cell adhesion molecule-1 were significantly higher in Groups A and C compared to the control groups (Groups G and H) on day 3 (P <0.05).Conclusions Single-unit platelet-rich fibrin glue has excellent biocompatibility and is associated with the upregulation of neovascularization.The addition of aminomethylbenzoic acid could prevent the degradation of fibrin glue.
基金Supported by National Natural Science Foundation of China(No.81100639No.81000367)+4 种基金Natural Science Foundation of Fujian Province,China(No.2012-CXB-30No.2013-2-112)Xiamen Science and Technology Plan Projects(No.3502Z20124037No.2011S0589No.3502Z20131017)
文摘AIM: To evaluate the outcomes and safety of lamellar keratoplasty(LK) assisted by fibrin glue in corneal perforations. ·METHODS: Six eyes of 6 patients affected by different corneal pathologies(2 posttraumatic corneal scar and 3 bacterial keratitis) underwent LK procedures by using fibrin glue. The mean corneal perforation diameter was 1.35 ±0.64mm(range,0.7-2.5mm),and the greatest diameter of the ulcerative stromal defect was 2.47 ± 0.77mm in average(range,1.5-3.5mm). The donor corneal lamella diameters were 0.20-mm larger and thicker than the recipient to restore a physiologic corneal thickness and shape: mean donor diameter was 8.34 ± 0.28mm(range,8.2-8.7mm) and mean thickness was 352±40.27mm(range,220-400mm). Mean follow-up was 7.33±1.97 months(range,6-11 months). Postoperatively,the graft status,graft clarity,anterior chamber response,the visual prognosis,intraocular pressures,and postoperative complications were recorded. ·RESULTS:Allthecornealperforationsweresuccessfully healed after the procedure. The best-corrected visual acuity(BCVA) ranged from 20/1 000 to 20/50 in their initial presentation,and from 20/100 to 20/20 in their last visit,showed increase in all the patients. No major complications such as graft dislocation and graft failure were noted. Neovascularization developed in the superficial stroma of donor graft in 1 case. High intraocular pressure developed on day 2 after surgery,while was remained in normal range after application of anti-glaucomatous eyedrops for 1 week in 1 case. ·CONCLUSION: Fibrin glue-assisted sutureless LK is valuable for maintaining the ocular integrity in the treatment of corneal perforations.