Investigating Load Regulation Characteristics of a Wind-PV-Coal Storage Multi-Power Generation System
1
作者 Zhongping Liu Enhui Sun +3 位作者 Jiahao Shi Lei Zhang Qi Wang Jiali Dong 《Energy Engineering》 EI 2024年第4期913-932,共20页
There is a growing need to explore the potential of coal-fired power plants(CFPPs)to enhance the utilization rate of wind power(wind)and photovoltaic power(PV)in the green energy field.This study developed a load regu... There is a growing need to explore the potential of coal-fired power plants(CFPPs)to enhance the utilization rate of wind power(wind)and photovoltaic power(PV)in the green energy field.This study developed a load regulation model for a multi-power generation system comprising wind,PV,and coal energy storage using realworld data.The power supply process was divided into eight fundamental load regulation scenarios,elucidating the influence of each scenario on load regulation.Within the framework of the multi-power generation system with the wind(50 MW)and PV(50 MW)alongside a CFPP(330 MW),a lithium-iron phosphate energy storage system(LIPBESS)was integrated to improve the system’s load regulation flexibility.The energy storage operation strategy was formulated based on the charging and discharging priority of the LIPBESS for each basic scenario and the charging and discharging load calculation method of LIPBESS auxiliary regulation.Through optimization using the particle swarm algorithm,the optimal capacity of LIPBESS was determined to be within the 5.24-4.88 MWh range.From an economic perspective,the LIPBESS operating with CFPP as the regulating power source was 49.1% lower in capacity compared to the renewable energy-based storage mode. 展开更多
关键词 Wind power coal-fired power PV multi-power generation system lithium-iron phosphate energy storage system
下载PDF
Review of the Analysis and Suppression for High-frequency Oscillations of the Grid-connected Wind Power Generation System
2
作者 Bo Pang Qi Si +4 位作者 Pan Jiang Kai Liao Xiaojuan Zhu Jianwei Yang Zhengyou He 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期127-142,共16页
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is... High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping. 展开更多
关键词 Damping method High-frequency oscillation STABILITY Wind power generation
下载PDF
MODELING AND NUMERICAL SIMULATION OF ONBOARD MOLECULAR SIEVE OXYGEN GENERATION SYSTEM 被引量:3
3
作者 武艳 林贵平 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2004年第1期47-52,共6页
A mathematical model for simulating concentric-bed and other components of molecular sieve oxygen concentrator is established. In the model, the binary Langmuir equilibrium adsorption equation is adopted to describe t... A mathematical model for simulating concentric-bed and other components of molecular sieve oxygen concentrator is established. In the model, the binary Langmuir equilibrium adsorption equation is adopted to describe the adsorption performance of the adsorbent, the linear driving force (LDF) model is used to describe the mass transfer rate, and the thermal effect during adsorption is considered. The finite difference method is used in simulation and comparison. Numerical results have a reasonable agreement with the experimental research. 展开更多
关键词 pressure swing adsorption molecular sieve gas separation onboard oxygen generation system (OBOGS)
下载PDF
Configuration optimization model of multi-energy distributed generation system 被引量:2
4
作者 徐青山 徐敏姣 +1 位作者 李国栋 蒋菱 《Journal of Southeast University(English Edition)》 EI CAS 2017年第2期182-188,共7页
To integrate different renewable energy resources effectively in a microgrid, a configuration optimization model of a multi-energy distributed generation(DG) system and its auxiliary equipment is proposed. The model... To integrate different renewable energy resources effectively in a microgrid, a configuration optimization model of a multi-energy distributed generation(DG) system and its auxiliary equipment is proposed. The model mainly consists of two parts, the determination of initial configuration schemes according to user preference and the selection of the optimal scheme. The comprehensive evaluation index(CEI), which is acquired through the analytic hierarchy process(AHP) weight calculation method, is adopted as the evaluation criterion to rank the initial schemes. The optimal scheme is obtained according to the ranking results. The proposed model takes the diversity of different equipment parameters and investment cost into consideration and can give relatively suitable and economical suggestions for system configuration.Additionally, unlike Homer Pro, the proposed model considers the complementation of different renewable energy resources, and thus the rationality of the multi-energy DG system is improved compared with the single evaluation criterion method which only considers the total cost. 展开更多
关键词 multi-energy complementation distributed generation(DG) optimal configuration energy management comprehensive evaluation index(CEI) analytic hierarchy process(AHP)
下载PDF
Nonlinear fast–slow dynamics of a coupled fractional order hydropower generation system 被引量:1
5
作者 Xiang Gao Diyi Chen +2 位作者 Hao Zhang Beibei Xu Xiangyu Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第12期538-545,共8页
Internal effects of the dynamic behaviors and nonlinear characteristics of a coupled fractional order hydropower generation system(HGS) are analyzed. A mathematical model of hydro-turbine governing system(HTGS) with r... Internal effects of the dynamic behaviors and nonlinear characteristics of a coupled fractional order hydropower generation system(HGS) are analyzed. A mathematical model of hydro-turbine governing system(HTGS) with rigid water hammer and hydro-turbine generator unit(HTGU) with fractional order damping forces are proposed. Based on Lagrange equations, a coupled fractional order HGS is established. Considering the dynamic transfer coefficient eis variational during the operation, introduced e as a periodic excitation into the HGS. The internal relationship of the dynamic behaviors between HTGS and HTGU is analyzed under different parameter values and fractional order. The results show obvious fast–slow dynamic behaviors in the HGS, causing corresponding vibration of the system, and some remarkable evolution phenomena take place with the changing of the periodic excitation parameter values. 展开更多
关键词 fast–slow dynamics fractional order nonlinear dynamics hydropower generation system
下载PDF
Harmonic detection an AC excited generation system based on in-phase correlation filtering 被引量:1
6
作者 贺益康 孙丹 +1 位作者 王文举 石赟 《Journal of Zhejiang University Science》 CSCD 2002年第1期65-71,共7页
The paper reports results of investigation on the harmonic detection technique of a complicated power supply system such as an AC excited generation system, which has a variable fundamental frequency and low order har... The paper reports results of investigation on the harmonic detection technique of a complicated power supply system such as an AC excited generation system, which has a variable fundamental frequency and low order harmonics with rich sub-harmonics whose frequencies are lower than the fundamental one. The in-phase correlation filtering technique, based on the frequency shifting principle, is proposed in this paper.Theoretical analysis and experimental results validate the effectiveness of this technique for the harmonic detections of AC excited generation systems. 展开更多
关键词 in\|phase correlation filtering harmonic detection AC excited generation system
下载PDF
An Overview of Research on Optimization of Integrated Solar/Wind Power Generation Systems 被引量:1
7
作者 Zhonglei Shao Kwok Lun Lo 《World Journal of Engineering and Technology》 2016年第3期35-42,共8页
Although transmission systems are able to cover most of the areas in many countries, there are still some isolated areas such as rural counties and remote desert lands where grid power cannot be accessed. Therefore, a... Although transmission systems are able to cover most of the areas in many countries, there are still some isolated areas such as rural counties and remote desert lands where grid power cannot be accessed. Therefore, a reliable and economical power supply scheme is required to solve the problem. One of them combines wind/solar power generation with the support of storage system. This paper is to give an overview of the optimization methodologies about the wind/solar stand-alone system supported by storage systems or integrating with other renewable or conventional power generation sources. It is shown that continued research and optimization methodology in this area are still in great need for performance improvement. 展开更多
关键词 Solar/Wind generation system OPTIMIZATION TECHNO-ECONOMIC
下载PDF
High Efficiency PCS with Scan-Type MPPT Control for a Grid-Connected PV Power Generation System 被引量:2
8
作者 Kazutaka Itako 《Journal of Energy and Power Engineering》 2014年第1期137-143,共7页
For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection int... For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments. 展开更多
关键词 PV generation system MPPT control grid-connecting inverter DC-DC converter PCS.
下载PDF
Study on Improvement of MPPT Efficiency in PV Generation System with Partial Shadow 被引量:1
9
作者 Kazutaka Itako Masataka Ochiai 《Journal of Energy and Power Engineering》 2017年第11期729-734,共6页
The maximum power point of PV (photovoltaic) generation moves depending on weather conditions and load. Therefore, it is significant to make sure that the panels can work at the maximum power point under MPPT (maxi... The maximum power point of PV (photovoltaic) generation moves depending on weather conditions and load. Therefore, it is significant to make sure that the panels can work at the maximum power point under MPPT (maximum power point tracking) control. However, it has the problems of low efficiency and unstable operation when panels are covered by the partial shadow. The result is that the output power may be substantially decreased. To overcome this issue, the authors propose a new plug-in operation point correction system. This system is put between PV panels and PCS (power conditioning system) in the existing PV generation system. In this paper, the experimental results describe that the output electric energy increases approximately 1.4 times as compared with the conventional system when the proposed correction system is inserted. 展开更多
关键词 PV generation system operation point correction MPPT partial shadow.
下载PDF
Analysis and Power Quality Improvement in Hybrid Distributed Generation System with Utilization of Unified Power Quality Conditioner
10
作者 Noor Zanib Munira Batool +4 位作者 Saleem Riaz Farkhanda Afzal Sufian Munawar Ibtisam Daqqa Najma Saleem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第2期1105-1136,共32页
This paper presents a comprehensive study that includes the sizing and power flow by series and parallel inverters in a distributed generation system(DGs)that integrates the system of hybrid wind photovoltaic with a u... This paper presents a comprehensive study that includes the sizing and power flow by series and parallel inverters in a distributed generation system(DGs)that integrates the system of hybrid wind photovoltaic with a unified power quality conditioner(UPQC).In addition to supplying active power to the utility grid,the system of hybrid wind photovoltaic functions as a UPQC,compensating reactive power and suppressing the harmonic load currents.Additionally,the load is supplied with harmonic-free,balanced and regulated output voltages.Since PVWind-UPQC is established on a dual compensation scheme,the series inverter works like a sinusoidal current source,while the parallel inverter works like a sinusoidal voltage source.Consequently,a smooth alteration from interconnected operating modes to island operating modes and vice versa can be achieved without load voltage transients.Since PV-Wind-UPQC inverters handle the energy generated through the hybrid wind photovoltaic system and the energy demanded through the load,the converters should be sized cautiously.A detailed study of the flow of power via the PV-Wind-UPQC is imperative to gain a complete understanding of the system operation and the proper design of the converters.Thus,curves that allow the sizing of the power converters according to the power flow via the converters are presented and discussed.Simulation results are presented to assess both steady state and dynamic performances of the grid connected hybrid system of PV-Wind-UPQC.This investigation is verified by simulating and analyzing the results with Matlab/Simulink. 展开更多
关键词 PHOTOVOLTAIC wind turbine unified power quality conditioner power flow distributed generation system
下载PDF
A Fuzzy Logical MPPT Control Strategy for PMSG Wind Generation Systems
11
作者 Xing-Peng Li Wen-Lu Fu +2 位作者 Qing-Jun Shi Jian-Bing Xu Quan-Yuan Jiang 《Journal of Electronic Science and Technology》 CAS 2013年第1期72-77,共6页
Making full use of wind power is one of the main purposes of the wind turbine generator control. Conventional hill climbing search (HCS) method can realize the maximum power point tracking (MPPT). However, the ste... Making full use of wind power is one of the main purposes of the wind turbine generator control. Conventional hill climbing search (HCS) method can realize the maximum power point tracking (MPPT). However, the step size of HCS method is constant so that it cannot consider both steady-state response and dynamic response. A fuzzy logical control (FLC) algorithm is proposed to solve this problem in this paper, which can track the maximum power point (MPP) quickly and smoothly. To evaluate MPPT algorithms, four performance indices are also proposed in this paper. They are the energy captured by wind turbine, the maximum power-point tracking time when wind speed changes slowly, the fluctuation magnitude of real power during steady state, and the energy captured by wind turbine when wind speed changes fast. Three cases are designed and simulated in MATLAB/Simulink respectively. The comparison of the three MPPT strategies concludes that the proposed fuzzy logical control algorithm is more superior to the conventional HCS algorithms. 展开更多
关键词 Fuzzy logical control hill climbing search maximum power point tracking permanent magnet synchronous generator wind generation system.
下载PDF
MPPT Control System for PV Generation System with Mismatched Modules
12
作者 Chengyang Huang Kazutaka Itako +1 位作者 Takeaki Mori Qiang Ge 《Journal of Energy and Power Engineering》 2015年第1期83-90,共8页
Nowadays, in a household PV (photovoltaic) generation system, it is generally connecting PV modules in series and then output to the power-conditioner. However, when PV modules are mismatched, it will lead to a wron... Nowadays, in a household PV (photovoltaic) generation system, it is generally connecting PV modules in series and then output to the power-conditioner. However, when PV modules are mismatched, it will lead to a wrong MPPT (maximum power point tracking) to all modules and a power decreasing of the whole system. Aiming at this problem, this paper presents the idea which improves the MPPT without changing the conventional power-conditioner, by adding a Buck type DC-DC (direct current) converter behind each module. Simulations of PSIM (power simulation) and experiments are taken to prove this theory. The result shows that, by this idea, the generated power of the conventional PV generation system can be greatly increased under the condition of mismatch. 展开更多
关键词 PV generation system MPPT Buck converter mismatched modules
下载PDF
Efficiency Improvement of PV Generation System by Using Improved P & O Method of MPPT
13
作者 Chengyang Huang Kazutaka Itako +1 位作者 Fakeaki Mori Qiang Ge 《Journal of Energy and Power Engineering》 2015年第5期486-492,共7页
The conventional P & O (perturb-and-observe) method, which is the most widely used as MPPT (maximum power point tracking) control, has the problem of low efficiency and unstable operation when solar radiation cha... The conventional P & O (perturb-and-observe) method, which is the most widely used as MPPT (maximum power point tracking) control, has the problem of low efficiency and unstable operation when solar radiation changes drastically. Aiming at this problem, this paper improves the conventional P & O method to reduce the bad effect of solar radiation by shortening the sampling interval of PV module's output power while keeping the operating period unchanged. Experiments are conducted to study efficiency gains of improved method when solar radiation changes drastically. The result shows that, by this method, the efficiency of MPPT control can be increased 17% in average when PV module simulator is used and 20% at maximum when actual PV module is used, compared with the conventional P & O method. 展开更多
关键词 PV generation system MPPT solar radiation change improvement of efficiency.
下载PDF
Dynamic Simulation of Novel Small Wind Turbine Generation System with SynRG
14
作者 Shohei Tokunaga Katsumi Kesamaru 《Journal of Energy and Power Engineering》 2012年第10期1611-1618,共8页
This paper describes a small wind turbine generation system with SynRG (synchronous reluctance generator). SynRGs are robust and inexpensive. In addition, SynRG has no cogging torque. Hence, wind turbine generation ... This paper describes a small wind turbine generation system with SynRG (synchronous reluctance generator). SynRGs are robust and inexpensive. In addition, SynRG has no cogging torque. Hence, wind turbine generation system with SynRG can achieve smooth start at low wind velocity. The rotor design of proposed SynRG is multi flux barrier type. With FEA (finite element analysis) software, the characteristics of SynRG are brought out, and the performance of wind turbine generation system with SynRG including copper loss and iron loss is simulated by FEA coupled with the motion equation of the wind turbine generation system under the maximum power point tracking control. In this paper, the constant wind test and the quasi-natural wind test are conducted. In conclusion, the results of these simulations indicate that the wind turbine generation system with SynRG has good performance, especially in starting phenomena. 展开更多
关键词 Small wind turbine generation system wind turbine generator SynRG (synchronous reluctance generator) finite element analysis coupled analysis.
下载PDF
Hot-Spot Detection System with Correction of Operating Point for PV Generation System
15
作者 Kazutaka Itako Naoaki Iiduka +1 位作者 Tsugutomo Kudoh Keishin Koh 《Journal of Energy and Power Engineering》 2017年第12期789-794,共6页
Currently, the production and the number of installations of PV (photovoltaic) modules have been increasing rapidly because of a feed-in tariff in Japan. Accordingly, the number of failures has also increased. Many ... Currently, the production and the number of installations of PV (photovoltaic) modules have been increasing rapidly because of a feed-in tariff in Japan. Accordingly, the number of failures has also increased. Many failures are a result of the Hot-Spot phenomenon in which defective cell becomes hot when shadow occurs on the cell, On the other hand, if shadow occurs on normal cell, there are cases that P&O method that is MPPT (maximum power point tracking) control method incorporated in conventional PV system cannot track maximum power point and generated power decreases. The correspondence is required rapidly if these trouble occur. However, conventional PV system monitors generated power, correspondence is impossible by monitoring generated power. Previously, the authors developed real time Hot-Spot detection system that incorporates into PCS (power conditioning system). Thus, the authors developed plug-in type Hot-Spot monitoring system that includes "PV peak shift method" and confirmed effectiveness of the system in this time. "PV peak shift method" loads "Scan method" that is MPPT control method and measures I-V (current-voltage) characteristic by changing voltage of module from open to short by "Scan method" on a regular basis. The developed Hot-Spot monitoring system uses slope of I-V characteristic of PV module. Inserting developed system into already installed PV system, Hot-Spot can be easily monitored in real time and PV system can be operated at maximum power point. 展开更多
关键词 PV generation system Hot-Spot phenomenon correction of operating point plug-in type.
下载PDF
Machine Learning and Data-Driven Techniques for the Control of Smart Power Generation Systems:An Uncertainty Handling Perspective 被引量:8
16
作者 Li Sun Fengqi You 《Engineering》 SCIE EI 2021年第9期1239-1247,共9页
Due to growing concerns regarding climate change and environmental protection,smart power generation has become essential for the economical and safe operation of both conventional thermal power plants and sustainable... Due to growing concerns regarding climate change and environmental protection,smart power generation has become essential for the economical and safe operation of both conventional thermal power plants and sustainable energy.Traditional first-principle model-based methods are becoming insufficient when faced with the ever-growing system scale and its various uncertainties.The burgeoning era of machine learning(ML)and data-driven control(DDC)techniques promises an improved alternative to these outdated methods.This paper reviews typical applications of ML and DDC at the level of monitoring,control,optimization,and fault detection of power generation systems,with a particular focus on uncovering how these methods can function in evaluating,counteracting,or withstanding the effects of the associated uncertainties.A holistic view is provided on the control techniques of smart power generation,from the regulation level to the planning level.The benefits of ML and DDC techniques are accordingly interpreted in terms of visibility,maneuverability,flexibility,profitability,and safety(abbreviated as the“5-TYs”),respectively.Finally,an outlook on future research and applications is presented. 展开更多
关键词 Smart power generation Machine learning Data-driven control systems engineering
下载PDF
Mobile power generation system based on biomass gasifcation 被引量:4
17
作者 Lu Ding Mingming Yang +5 位作者 Kai Dong Dai‑Viet N.Vo Douglas Hungwe Jiahan Ye Alexander Ryzhkov Kunio Yoshikawa 《International Journal of Coal Science & Technology》 EI CAS CSCD 2022年第3期171-184,共14页
Disaster-hit and/or un-electrifed remote areas usually have electricity accessibility issues and an abundance of plant-derived debris and wood from destroyed wooden structures;this can be potentially addressed by empl... Disaster-hit and/or un-electrifed remote areas usually have electricity accessibility issues and an abundance of plant-derived debris and wood from destroyed wooden structures;this can be potentially addressed by employing a decentralized ultrasmall biomass-fed gasifcation power generating system.This paper presents an assessment of the technical viability of an ultra-small gasifcation system that utilizes densifed carbonized wood pellets/briquettes.The setup was run continuously for 100 h.A variety of biomass was densifed and carbonized by harnessing fugitive heat sources before charging into the reactor.Carbonized briquettes and furnished blends exhibited inferior gasifcation performance compared to the carbonized pellets.In the absence of tar blockage problems,steady-state conditions were achieved when pre-treated feedstock was used.Under steady-state conditions for carbonized pellets gasifcation operated at an equivalence ratio of 0.32,cold gas efciency and carbon conversion achieved 49.2%and 70.5%,respectively.Overall efciency and maximum power output of 20.3%and 21 kW were realised,respectively.It was found that the system could keep stable while the low heating valve of syngas was over 4 MJ/m^(3)on condition that avoiding tar blocking issues.The results indicate that the proposed compact ultra-small power generation system is a technically feasible approach to remedy power shortage challenge.In addition,process simulation considering carbonized wood gasifcation combined power generation was formulated to produce syngas and electricity.Woody pellets with the fow rate of 20 kg/h could generate a 15.18 kW power at the air fow rate of 40 Nm^(3)/h,which is in a good agreement with 15 kW in the 100 h operation.It is indicated that the gasifcation combined power generation cycle simulated by Aspen simulator could achieve reliable data to assist the complicated experiment operation. 展开更多
关键词 Small-scale power generation Densifcation Carbonized pellet Carbonized briquette Gasifcation
下载PDF
Experimental Study on Aerodynamic Characteristics of the Model Wind Rotor System and on Characterization of A Wind Generation System 被引量:2
18
作者 MENG Long HE Yan-ping +2 位作者 ZHAO Yong-sheng PENG Tao YANG Jie 《China Ocean Engineering》 SCIE EI CSCD 2019年第2期137-147,共11页
In order to investigate the aerodynamic characteristics of 6-MW wind turbine, experimental study on the aerodynamic characteristics of the model rotor system and on characterization of a wind generation system is carr... In order to investigate the aerodynamic characteristics of 6-MW wind turbine, experimental study on the aerodynamic characteristics of the model rotor system and on characterization of a wind generation system is carried out. In the test, a thrust-matched rotor system and a geometry-matched rotor system, which utilize redesigned thrustmatched and original geometry-matched blades, respectively, are applied. The 6-MW wind turbine system is introduced briefly. The proper scaling laws for model tests are established in the paper, which are then implemented in the construction of a model wind turbine with optimally designed blades. And the parameters of the model are provided. The aerodynamic characteristics of the proposed 6-MW wind rotor system are explored by testing a 1:65.3 scale model at the State Key Laboratory of Ocean Engineering at Shanghai Jiao Tong University. Before carrying out the wind rotor system test, the turbulence intensity and spatial uniformity of the wind generation system are tested and results demonstrate that the characterization of the wind generation system is satisfied and the average turbulence intensity of less than 10% within the wind rotor plane is proved in the test. And then, the aerodynamic characteristics of 6-MW wind rotor system are investigated. The response characteristic differences between the thrust-matched rotor system and the geometry-matched rotor system are presented. Results indicate that the aerodynamic characteristics of 6-MW wind rotor with the thrust-matched rotor system are satisfied. The conclusion is that the thrust-matched rotor system can better reflect the characteristics of the prototype wind turbine. A set of model test method is proposed in the work and preparations for further model basin test of the 6-MW SPAR-type floating offshore wind turbine system are made. 展开更多
关键词 thrust-matched ROTOR system geometry-matched ROTOR system WIND generation system experimental study aerodynamic characteristics
下载PDF
Non-dominated sorting culture differential evolution algorithm for multi-objective optimal operation of Wind-Solar-Hydro complementary power generation system 被引量:3
19
作者 Guanjun Liu Hui Qin +2 位作者 Rui Tian Lingyun Tang Jie Li 《Global Energy Interconnection》 2019年第4期368-374,共7页
Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total sys... Due to the intermittency and instability of Wind-Solar energy and easy compensation of hydropower, this study proposes a Wind-Solar-Hydro power optimal scheduling model. This model is aimed at maximizing the total system power generation and the minimum ten-day joint output. To effectively optimize the multi-objective model, a new algorithm named non-dominated sorting culture differential evolution algorithm(NSCDE) is proposed. The feasibility of NSCDE was verified through several well-known benchmark problems. It was then applied to the Jinping Wind-Solar-Hydro complementary power generation system. The results demonstrate that NSCDE can provide decision makers a series of optimized scheduling schemes. 展开更多
关键词 Wind-Solar-Hydro COMPLEMENTARY power generation system Scheduling strategy MULTI-OBJECTIVE optimization CULTURE algorithm
下载PDF
Study and performance test of 10 kW molten carbonate fuel cell power generation system 被引量:1
20
作者 Chengzhuang Lu Ruiyun Zhang +3 位作者 Guanjun Yang Hua Huang Jian Cheng Shisen Xu 《International Journal of Coal Science & Technology》 EI CAS CSCD 2021年第3期368-376,共9页
The use of high-temperature fuel cells as a power technology can improve the efficiency of electricity generation and achieve near-zero emissions of carbon dioxide.This work explores the performance of a 10 kW high-te... The use of high-temperature fuel cells as a power technology can improve the efficiency of electricity generation and achieve near-zero emissions of carbon dioxide.This work explores the performance of a 10 kW high-temperature molten carbonate fuel cell.The key materials of a single cell were characterized and analyzed using X-ray diffraction and scanning electron microscopy.The results show that the pore size of the key electrode material is 6.5 lm and the matrix material is a-LiAlO_(2).Experimentally,the open circuit voltage of the single cell was found to be 1.23 V.The current density was greater than 100 mA/cm^(2)at an operating voltage of 0.7 V.The 10 kW fuel cell stack comprised 80 single fuel cells with a total area of 2000 cm^(2)and achieved an open circuit voltage of greater than 85 V.The fuel cell stack power and current density could reach 11.7 kW and 104.5 mA/cm2 at an operating voltage of 56 V.The influence and long-term stable operation of the stack were also analyzed and discussed.The successful operation of a 10 kW high-temperature fuel cell promotes the large-scale use of fuel cells and provides a research basis for future investigations of fuel cell capacity enhancement and distributed generation in China. 展开更多
关键词 Fuel cell stack Key materials Molten carbonate fuel cell Power generation test
下载PDF