Aiming at the seismic-resistant performance of cable-supported glass curtain walls,the methods for formulating nonlinear single degree of freedom system and calculating the nonlinear response spectrums are proposed. T...Aiming at the seismic-resistant performance of cable-supported glass curtain walls,the methods for formulating nonlinear single degree of freedom system and calculating the nonlinear response spectrums are proposed. Taking pretension effect in cables and geometrical nonlinearity into account,the nonlinear acceleration spectrums are calculated under given conditions,such as site and different seismic fortification intensities. The seismic design response spectrums are developed. During vibrating,varying period due to the influence of pretension effect in cables and geometrical nonlinearity drives the maximum period of plateau in nonlinear response spectrums to move towards the long period zone,and the maximum of seismic effect coefficient is larger than that of current seismic code. The theoretical analysis and the example demonstrate that using the nonlinear response spectrums is safe and economical.展开更多
The glass curtain wall is widely favored by the owners for its good appearance modeling efthct. In using process, however, excessive energy consumption, low level indoor eomtort and other problems of glass curtain wal...The glass curtain wall is widely favored by the owners for its good appearance modeling efthct. In using process, however, excessive energy consumption, low level indoor eomtort and other problems of glass curtain wall are often exposed. Aiming at office buildings in hot Summer and cold Winter zone, taking the optimization of thermal comfort of double glass curtain wall in the summer and the reduetion of building energy consumption throughout the year as the breakthrough point, using the method of energy simulation analysis, through changing the size of internal shading component in the simulated room, this paper analyzes and summarizes the variation law of its energy consumption value, to explore the relatively reasonable design plan of shading systems of the building with glass curtain wall.展开更多
Integrated landscaping technology of reclaiming condensed water from the thermal channel of double-pane glass curtain wall and applying the reclaimed water in micro irrigation of natural plants was explored.Selection ...Integrated landscaping technology of reclaiming condensed water from the thermal channel of double-pane glass curtain wall and applying the reclaimed water in micro irrigation of natural plants was explored.Selection of plant species for the internal space of glass curtain wall and vertical greening outside was studied to meet the ecological technological requirements of glass curtain wall.Progressive experiment of new technology and simulated calculation of indexes were applied to obtain solar radiation consumption,meet the ecological characters of plants in glass curtain walls,and finally improve indoor and outdoor thermal environment.The results showed that new ecological technologies of applying plants on glass curtain walls help realize ecological utilization of glass curtain walls,further reduce energy consumption of buildings,achieve and even surpass the standards of national 3-star green buildings.展开更多
In order to solve the conflict between indoor lighting and PV cells in building-integrated photovoltaic/thermal(BIPV/T) systems, a glass curtain wall system based on a tiny transmissive concentrator is proposed. This ...In order to solve the conflict between indoor lighting and PV cells in building-integrated photovoltaic/thermal(BIPV/T) systems, a glass curtain wall system based on a tiny transmissive concentrator is proposed. This glass curtain wall has a direct influence on the heat transfer between indoor and outdoor, and the operating parameters of air and water inlet temperature, indoor and outdoor temperature, and radiation intensity have a significant influence on the heat transfer characteristics of the glass curtain wall. The 3D model is established by SoildWorks software, and the thermal characteristics of the new glass curtain wall system are simulated through computational fluid dynamics(CFD) method. Thermal performance was tested under actual weather for the winter working conditions. The CFD simulation results are verified by the test results under actual weather. The results show that thermal efficiency simulation results are in good agreement with the experimental results of the new glass curtain wall system. The simulation conditions were designed by using the orthogonal method, and the significance analysis of the influencing factors of the indoor wall surface heat gain was carried out. With the increase of the bottom heat flux and the air velocity, the heat absorption of the inner wall surface increases. When the wind speed is 0.1 m/s, the heat flow on the bottom surface rises from 500 W/m^(2) to 2500 W/m^(2), and the heat flow intensity on the interior wall changes from 10.31 W/m^(2) to -29.12 W/m^(2). Under typical working conditions, the new glass curtain wall system can reduce the indoor heat load by 47.5% than ordinary glass curtain wall.展开更多
The aim of this study is to analyze of the cable-glass systems which are used on the glass curtain wall according to their types, degree, architectural and structural effects. The suspended glass system with pre-stres...The aim of this study is to analyze of the cable-glass systems which are used on the glass curtain wall according to their types, degree, architectural and structural effects. The suspended glass system with pre-stressed cable truss (SGSPCT) is widely started to apply after the 1980’s with Serres building. The advantages of these systems are to provide the transparency on the fa?ades and speedy construction process with minimum materials. The disadvantages are: more expensive than other systems and so many details for the joints and load distribution calculations. There are three different architectural design typologies of the SGSPCT system. These are distance bridging systems, between floor system and independent body. These three different typologies can be seen on the same building at the same time. This system has been known as complex structure systems. The twenty five glass buildings which are designed in different systems have been analyzed during this study. After these analyses the five glass buildings which are designed with cable-truss system have been selected for scope of the study. These selected buildings have been included of three different cable-truss system typologies and degree. The methodology of this study is literature survey and building analyses method. The written and visual documents involve books, theses, reports, articles, magazines, drawings, internet sources and applied connection details of the glass buildings. The selected five glass buildings have been detailed analyzed with their architectural drawings, photographs and details. The study consists of five chapters including the introduction chapter. The general information of the glass building and cable-glass system has been mentioned in the first chapter. The structural features, details and analytical information on systems have been explained of the selected buildings in the second chapter. The detailed analyses of these selected buildings have been done according to their schematic drawings with the plans, sections and load distribution in the third chapter. The fourth chapter is discussion section. In this section, cable-truss systems have been compared with their advantages and disadvantages to the other systems. The fifth chapter is the last chapter, many advantages of cable-truss systems have been concluded that the use of glass substrates.展开更多
基金the National Natural Science Foundation of China (Grant No. 50478028).
文摘Aiming at the seismic-resistant performance of cable-supported glass curtain walls,the methods for formulating nonlinear single degree of freedom system and calculating the nonlinear response spectrums are proposed. Taking pretension effect in cables and geometrical nonlinearity into account,the nonlinear acceleration spectrums are calculated under given conditions,such as site and different seismic fortification intensities. The seismic design response spectrums are developed. During vibrating,varying period due to the influence of pretension effect in cables and geometrical nonlinearity drives the maximum period of plateau in nonlinear response spectrums to move towards the long period zone,and the maximum of seismic effect coefficient is larger than that of current seismic code. The theoretical analysis and the example demonstrate that using the nonlinear response spectrums is safe and economical.
文摘The glass curtain wall is widely favored by the owners for its good appearance modeling efthct. In using process, however, excessive energy consumption, low level indoor eomtort and other problems of glass curtain wall are often exposed. Aiming at office buildings in hot Summer and cold Winter zone, taking the optimization of thermal comfort of double glass curtain wall in the summer and the reduetion of building energy consumption throughout the year as the breakthrough point, using the method of energy simulation analysis, through changing the size of internal shading component in the simulated room, this paper analyzes and summarizes the variation law of its energy consumption value, to explore the relatively reasonable design plan of shading systems of the building with glass curtain wall.
基金Supported by Foundation Program of Suzhou Low-carbon Economy and Technology Research Center:Innovation and Design of Low Carbon Emission for Suzhou Green Urban Architectural Complex(Q313801010)
文摘Integrated landscaping technology of reclaiming condensed water from the thermal channel of double-pane glass curtain wall and applying the reclaimed water in micro irrigation of natural plants was explored.Selection of plant species for the internal space of glass curtain wall and vertical greening outside was studied to meet the ecological technological requirements of glass curtain wall.Progressive experiment of new technology and simulated calculation of indexes were applied to obtain solar radiation consumption,meet the ecological characters of plants in glass curtain walls,and finally improve indoor and outdoor thermal environment.The results showed that new ecological technologies of applying plants on glass curtain walls help realize ecological utilization of glass curtain walls,further reduce energy consumption of buildings,achieve and even surpass the standards of national 3-star green buildings.
基金supported by the National Natural Science Foundation of China(51766013,51766012)the Inner Mongolia Natural Science Foundation of China(2020LH05014,2019MS05025)the Inner Mongolia Science and Technology Major Project in 2019。
文摘In order to solve the conflict between indoor lighting and PV cells in building-integrated photovoltaic/thermal(BIPV/T) systems, a glass curtain wall system based on a tiny transmissive concentrator is proposed. This glass curtain wall has a direct influence on the heat transfer between indoor and outdoor, and the operating parameters of air and water inlet temperature, indoor and outdoor temperature, and radiation intensity have a significant influence on the heat transfer characteristics of the glass curtain wall. The 3D model is established by SoildWorks software, and the thermal characteristics of the new glass curtain wall system are simulated through computational fluid dynamics(CFD) method. Thermal performance was tested under actual weather for the winter working conditions. The CFD simulation results are verified by the test results under actual weather. The results show that thermal efficiency simulation results are in good agreement with the experimental results of the new glass curtain wall system. The simulation conditions were designed by using the orthogonal method, and the significance analysis of the influencing factors of the indoor wall surface heat gain was carried out. With the increase of the bottom heat flux and the air velocity, the heat absorption of the inner wall surface increases. When the wind speed is 0.1 m/s, the heat flow on the bottom surface rises from 500 W/m^(2) to 2500 W/m^(2), and the heat flow intensity on the interior wall changes from 10.31 W/m^(2) to -29.12 W/m^(2). Under typical working conditions, the new glass curtain wall system can reduce the indoor heat load by 47.5% than ordinary glass curtain wall.
文摘The aim of this study is to analyze of the cable-glass systems which are used on the glass curtain wall according to their types, degree, architectural and structural effects. The suspended glass system with pre-stressed cable truss (SGSPCT) is widely started to apply after the 1980’s with Serres building. The advantages of these systems are to provide the transparency on the fa?ades and speedy construction process with minimum materials. The disadvantages are: more expensive than other systems and so many details for the joints and load distribution calculations. There are three different architectural design typologies of the SGSPCT system. These are distance bridging systems, between floor system and independent body. These three different typologies can be seen on the same building at the same time. This system has been known as complex structure systems. The twenty five glass buildings which are designed in different systems have been analyzed during this study. After these analyses the five glass buildings which are designed with cable-truss system have been selected for scope of the study. These selected buildings have been included of three different cable-truss system typologies and degree. The methodology of this study is literature survey and building analyses method. The written and visual documents involve books, theses, reports, articles, magazines, drawings, internet sources and applied connection details of the glass buildings. The selected five glass buildings have been detailed analyzed with their architectural drawings, photographs and details. The study consists of five chapters including the introduction chapter. The general information of the glass building and cable-glass system has been mentioned in the first chapter. The structural features, details and analytical information on systems have been explained of the selected buildings in the second chapter. The detailed analyses of these selected buildings have been done according to their schematic drawings with the plans, sections and load distribution in the third chapter. The fourth chapter is discussion section. In this section, cable-truss systems have been compared with their advantages and disadvantages to the other systems. The fifth chapter is the last chapter, many advantages of cable-truss systems have been concluded that the use of glass substrates.