Glass fibre reinforced concrete placement technique generates losses due to rebound effects of the already sprayed concrete particles.Rebounded concrete amount cause a significant difference between the initial mix de...Glass fibre reinforced concrete placement technique generates losses due to rebound effects of the already sprayed concrete particles.Rebounded concrete amount cause a significant difference between the initial mix design and emplaced mix compositions.Apart from the structural differences,it comes with a cost increase which was resulted by the splashed concrete amount.Many factors such as viscosity and quantity of mixes dominate this rebound amount in sprayed glass fibre reinforced concrete applications depending on production technologies and processes;however,this research focuses on the spray distance and the angle of the spray gun which mainly effects the rebound amount in glass fibre reinforced concrete production.This paper aims to understand the required angle and distance for glass fibre reinforced concrete mixes having on-site plastic viscosity values.Glass fibre reinforced mixtures were also modelled with a finite element method based software and,the analysis results were compared with production line results.Results of the analysis and on-site studies showed a decisive correlation between,discharge distance,discharge angle and the viscosity of the concrete.展开更多
Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case ...Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case of seismic forces. Numerous retrofitting works using fibre reinforced polymer (FRP) composites are being undertaken worldwide. This work aims to investigate the effectiveness of strengthening beam-column joints using natural and artificial fibres. In this study, basalt (natural fibres) as monolithic composite (BFRP) and as hybrid composite along with glass (artificial fibres) were used for strengthening of beam-column joints. Totally six specimens were prepared and tested under monotonic loading. Specimen details used were: two control specimen, two specimens for monolithic wrapping and remaining two specimens for hybrid wrapping. The test results were compared with control and rehabilitated specimens. The performance of the treated joints was studied using the following parameters: initial and ultimate cracking loads, energy absorption, deflection ductility and stiffness at ultimate. From the test results, it was found that the hybrid combination of Basalt and Glass FRPs were found to be more effective in the treatment of beam-column joints. The strong column weak beam concept was achieved by failure in beam portion which helped in preventing the catastrophic failure of the entire structure.展开更多
文摘Glass fibre reinforced concrete placement technique generates losses due to rebound effects of the already sprayed concrete particles.Rebounded concrete amount cause a significant difference between the initial mix design and emplaced mix compositions.Apart from the structural differences,it comes with a cost increase which was resulted by the splashed concrete amount.Many factors such as viscosity and quantity of mixes dominate this rebound amount in sprayed glass fibre reinforced concrete applications depending on production technologies and processes;however,this research focuses on the spray distance and the angle of the spray gun which mainly effects the rebound amount in glass fibre reinforced concrete production.This paper aims to understand the required angle and distance for glass fibre reinforced concrete mixes having on-site plastic viscosity values.Glass fibre reinforced mixtures were also modelled with a finite element method based software and,the analysis results were compared with production line results.Results of the analysis and on-site studies showed a decisive correlation between,discharge distance,discharge angle and the viscosity of the concrete.
文摘Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case of seismic forces. Numerous retrofitting works using fibre reinforced polymer (FRP) composites are being undertaken worldwide. This work aims to investigate the effectiveness of strengthening beam-column joints using natural and artificial fibres. In this study, basalt (natural fibres) as monolithic composite (BFRP) and as hybrid composite along with glass (artificial fibres) were used for strengthening of beam-column joints. Totally six specimens were prepared and tested under monotonic loading. Specimen details used were: two control specimen, two specimens for monolithic wrapping and remaining two specimens for hybrid wrapping. The test results were compared with control and rehabilitated specimens. The performance of the treated joints was studied using the following parameters: initial and ultimate cracking loads, energy absorption, deflection ductility and stiffness at ultimate. From the test results, it was found that the hybrid combination of Basalt and Glass FRPs were found to be more effective in the treatment of beam-column joints. The strong column weak beam concept was achieved by failure in beam portion which helped in preventing the catastrophic failure of the entire structure.