期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Glassy carbon electrode modified with multi-walled carbon nanotubes sensor for the quantihication of antihistamine drug pheniramine in solubilized systems 被引量:1
1
作者 Rajeev Jain Sanjay Sharma 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第1期56-61,共6页
A sensitive electroanalytical method for quantification of pheniramine in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at glassy carbon electrode modified with... A sensitive electroanalytical method for quantification of pheniramine in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at glassy carbon electrode modified with multi-walled carbon nanotubes in the presence of sodium lauryl sulfate.The experimental results suggest that the phcniramine in anionic surfactant solution exhibits electrocatalytic effect resulting in a marked enhancement of the peak current response.Peak current response is linearly dependent on the concentration of pheniramine in the range 200-1500 μg/mL with correlation coefficient 0.9987.The limit of detection is 58.31 μg/m L.The modified electrode shows good sensitivity and repeatability. 展开更多
关键词 PHENIRAMINE Sodium lauryl sulfate (SLS) glassy carbon electrode modified with multi-walled carbon nanotubes (GCE-MWCNTs) Solubilized systems Voltammetric quantification
下载PDF
Voltammetric Response and Electrocatalysis of Glasy Carbon Electrode Modified with Monolayer Nickel Hydroxide
2
作者 Liu Shouqing Li Huiling +1 位作者 Jiang Mian Li Peibiao 《Wuhan University Journal of Natural Sciences》 CAS 1997年第1期90-94,共5页
The glassy carbon (GC) electrode modified with a monolayer nickel hydroxide (GC/Ni(OH) 2) was prepared by immersion of GC substrate in 1.0×10 -3 mol/L NiSO 4 solution, and then cyclic voltammetric scannin... The glassy carbon (GC) electrode modified with a monolayer nickel hydroxide (GC/Ni(OH) 2) was prepared by immersion of GC substrate in 1.0×10 -3 mol/L NiSO 4 solution, and then cyclic voltammetric scanning in 0.20 mol/L KOH. Similarly, GC/Co(OH) 2 electrode was prepared too. The experiments showed that the voltammetric behavior of GC/Ni(OH) 2 electrode in 0.20 mol/L KOH is more stable than that of GC/ Co(OH) 2. It was found that the GC/Ni(OH) 2 electrode acts as an effective electrocatalysis for the oxidation of hydrazine. 展开更多
关键词 glassy carbon modified electrode MONOLAYER nickel hydroxide cobalt hydroxide electroctalysis HYDRAZINE
下载PDF
上一页 1 下一页 到第