期刊文献+
共找到2,015篇文章
< 1 2 101 >
每页显示 20 50 100
Determination of vanadium in food and traditional Chinese medicine by graphite furnace atomic absorption spectroscopy 被引量:3
1
作者 ZOUMingqiang JIANGTiansu +1 位作者 WANGDaning ZHAIQingzhou 《Rare Metals》 SCIE EI CAS CSCD 2003年第1期14-18,共5页
Various experimental conditions were described for the vanadium determinationby graphite furnace atomic absorption spectroscopy (GFAAS). The experiments showed that whenatomization took place under the conditions wher... Various experimental conditions were described for the vanadium determinationby graphite furnace atomic absorption spectroscopy (GFAAS). The experiments showed that whenatomization took place under the conditions where the combination of a pyrolytic coating graphitetube and fast raising temperature were used and the temperature was stable, the signal peak shapescould be improved, the sensitivity was enhanced, and the memory effect was removed. The vanadium infood and traditional Chinese medicinal herbs can be accurately determined using the standard curvemethod. 展开更多
关键词 vanadium determination graphite furnace atomic absorption spectroscopy(GFAAS) FOOD traditional Chinese medicinal herb
下载PDF
Determination of Trace Amounts of Nickel (Ⅱ) by Graphite Furnace Atomic Absorption Spectrometry Coupled with Cloud Point Extraction 被引量:3
2
作者 SHAH Syed Mazhar WANG Hao-nan SU Xing-guang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期366-370,共5页
A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-... A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-hydroxyquinoline and Triton X-100 were used as the ligand and surfactant respectively. Nickel(Ⅱ) can form a hy-drophobic complex with 8-hydroxyquinoline, the complex can be extracted into the small volume surfactant rich phase at the cloud point temperature(CPT) for GFAAS determination. The factors affecting the cloud point extraction, such as pH, ligand concentration, surfactant concentration, and the incubation time were optimized. Under the optimal conditions, a detection limit of 12 ng/L and a relative standard deviation(RSD) of 2.9% were obtained for Ni(Ⅱ) determination. The enrichment factor was found to be 25. The proposed method was successfully applied to the determination of nickel(Ⅱ) in certified reference material and different types of water samples and the recovery was in a range of 95%―103%. 展开更多
关键词 Cloud point extraction Phase separation graphite furnace atomic absorption spectrometry Nickel(Ⅱ)
下载PDF
A Study of the Background Absorption of Chitosan in the Graphite Furnace Atomic Absorption Spectrometry 被引量:1
3
作者 TANG You wen MO Sheng jun 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1997年第4期82-85,共4页
AStudyoftheBackgroundAbsorptionofChitosanintheGraphiteFurnaceAtomicAbsorptionSpectrometryTANGYou-wen*andMOSh... AStudyoftheBackgroundAbsorptionofChitosanintheGraphiteFurnaceAtomicAbsorptionSpectrometryTANGYou-wen*andMOSheng-jun(Departmen... 展开更多
关键词 graphite absorption atomic BACKGROUND CHITOSAN furnace SPECTROMETRY
下载PDF
Preconcentration of Vanadium(Ⅴ) on Crosslinked Chitosan and Determination by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
4
作者 Wu Wei Qian Sha-hua +2 位作者 Xiao Mei Huang Gan-quan Chen Hao 《Wuhan University Journal of Natural Sciences》 CAS 2002年第2期222-226,共5页
A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by C... A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by CCTS was 97% at pH 4.0, and vanadium(Ⅴ) was eluted from crosslinked chitosan with 2 mL 2.0 mol·L -1 chlorhydric acid and determined by GFAAS. The detection limit (3σ,n=7) for vanadium(Ⅴ) was 4.8×1 0 -12g and the relative standard deviation (R.S.D) at concentration level of 2.6 μg·L -1 is less than 3.6%. The method shows a good selectivity and high sensitivity, and it was applied to determination of vanadium(Ⅴ) in oyster and water samples. The analytic recoveries are (97±5)%. 展开更多
关键词 crosslinked chitosan (CCTS) vanadium(Ⅴ) PRECONCENTRATION DESORPTION graphite furnace atomic absorption spectrometry (GFAAS) OYSTER sea water
下载PDF
Determination of Trace Iron in High Purity Sodium Fluoride by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
5
作者 QIAN Sha-hua HUANG Gan-quan +2 位作者 XUE Ai-fang CHEN Li-hua WANG Mei-lin (College of Chemistry and Environmental Science, Wuhan University, Wuhan, 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期106-108,共3页
A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that th... A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that the ashing temperature can be increased to 1 400°C and matrix interferences eliminated, the sensitivity of iron increased in 1. 27 fold by the addition of nickel nitrate. The method is applied to the determination of iron in sodium fluoride and satisfactory results are obtained. 展开更多
关键词 Key words graphite furnace atomic absorption spectrometry iron determination sodium fluoride matrix modifier
下载PDF
Determination of Trace Amounts of Lead by Modified Graphite Furnace Atomic Absorption Spectrometry after Liquid Phase Microextraction with Pyrimidine-2-thiol 被引量:1
6
作者 Saeid Nazari 《American Journal of Analytical Chemistry》 2011年第7期757-767,共11页
The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lea... The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lead was extracted from a 2 ml of its aqueous sample in the pH = 5 as lead-Pyrimidine-2-thiol cationic complex into a 4 μl drop of 1,2 dichloroethane and ammonium tetraphenylborate as counter ion immersed in the solution. In the drop, the lead-Pyrimidine-2-thiol ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [W.Pd.Mg] (c). Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time, stirring rate and effect of salt were optimized. Under the optimum conditions, the enrichment factor and recovery were 525% and 94%, respectively. The calibration graph was linear in the range of 0.01 - 12 μg?L–1 with correlation coefficient of 0.9975 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0072 μg?L–1 and relative standard deviation (RSD) for ten replicate measurement of 0.1 μg?L–1 and 0.4 μg?L–1 lead was 4.5% and 3.8% respectively. The characteristic concentration was 0.0065 μg?L–1 equivalent to a characteristic mass of 26 fg. The results for determination of lead in reference materials, spiked tap water and seawater demonstrated the accuracy, recovery and applicability of the presented method. 展开更多
关键词 LEAD Liquid Phase MICROEXTRACTION PRECONCENTRATION graphite furnace atomic absorption Spectrometry
下载PDF
A Study of the Background Absorption of Slurry Algae in the Graphite Furnace Atomic Absorption Spectrometry
7
作者 MO Sheng-jun, SONG Jian-yi, LIN Zhuo-xin and TONG You-wen (Department of Chemistry, South China Normal University, Guangzhou, 510631) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第3期256-260,共5页
In general, biological organisms have the ability to absorb a specific element selectively. Holcombe and his co-workers reported that copper, nickel and cobalt could be separated from riverine and sea-water samples an... In general, biological organisms have the ability to absorb a specific element selectively. Holcombe and his co-workers reported that copper, nickel and cobalt could be separated from riverine and sea-water samples and cadmium from river water samples by unicellular green algae and were determined by slurry GFAAS. Dar- 展开更多
关键词 graphite furnace atomic absorption spectrometry (GFAAS) Background absorption ALGAE
下载PDF
Determination of Pb Content in Soil Samples by Graphite Furnace Atomic Absorption Spectrometry
8
作者 Feng Huang Yihu Zeng +1 位作者 Jinxian Tang Ting Yang 《Meteorological and Environmental Research》 CAS 2013年第9期32-33,共2页
[ Objective] A method was established to determine trace Pb in soil by graphite furnace atomic absorption spectrometry. [ Method] The pre-treatment of soil sample was conducted by nitric acid -perchloric acid -hydroch... [ Objective] A method was established to determine trace Pb in soil by graphite furnace atomic absorption spectrometry. [ Method] The pre-treatment of soil sample was conducted by nitric acid -perchloric acid -hydrochloric acid system. Palladium nitrate was added to eliminate ma- trix interference. Digestion acid, ashing and atomization temperature of the sample were selected. The operating parameters of instrument and tem- perature-rise program of graphite furnace were optimized. National standard matter was used to verify accuracy of the method. [Result] The detec- tion limit for Pb was 0.27 μg/g by graphite furnace atomic absorption spectrometry, and the recovery rate was 91.0% -96.1%. [ Conclusion The method had rapid analysis velocity, high sensitivity, less interference and easy operation. When applied to determination of trace Pb in the soil, the method obtained satisfactory results. 展开更多
关键词 graphite furnace atomic absorption spectrometry SOIL PB China
下载PDF
Measuring Conditions for the Determination of Lead in Iron-Matrix Samples Using Graphite Atomizers with/without a Platform in Graphite Furnace Atomic Absorption Spectrometry
9
作者 Syun Morimoto Tetsuya Ashino Kazuaki Wagatsuma 《American Journal of Analytical Chemistry》 2011年第6期710-717,共8页
In graphite furnace atomic absorption spectrometry (GF-AAS), the atomization process of lead occurring in graphite atomizers with/without a platform plate was investigated when palladium was added to an iron-matrix sa... In graphite furnace atomic absorption spectrometry (GF-AAS), the atomization process of lead occurring in graphite atomizers with/without a platform plate was investigated when palladium was added to an iron-matrix sample solution containing trace amounts of lead. Absorption profiles of a lead line were meas- ured at various compositions of iron and palladium. Variations in the gas temperature were also estimated with the progress of atomization, by using a two-line method under the assumption of a Boltzmann distribu- tion. Each addition of iron and palladium increased the lead absorbance in both the atomizers, indicating that iron or palladium became an effective matrix modifier for the determination of lead. Especially, palladium played a significant role for controlling chemical species of lead at the charring stage in the platform-type atomizer, to change several chemical species to a single species and eventually to yield a dominant peak of the lead absorbance at the atomizing stage. Furthermore, the addition of palladium delayed the peak after the gas atmosphere in the atomizer was heated to a higher temperature. These phenomena would be because the temperature of the platform at the charring stage was elevated more slowly compared to that of the furnace wall, and also because a thermally-stable compound, such as a palladium-lead solid solution, was produced by their metallurgical reaction during heating of the charring stage. A platform-type atomizer with palladium as the matrix modifier is recommended for the determination of lead in GF-AAS. The optimum condition for this was obtained in a coexistence of 1.0 × 10–2 g/dm3 palladium, when the charring at 973 K and then the atomizing at 3073 K were conducted. 展开更多
关键词 graphite furnace atomic absorption Spectrometry PLATFORM atomIZER Gas Temperature MATRIX MODIFIER LEAD Iron Palladium
下载PDF
Investigation of Distribution for Trace Lead and Cadmium in Chinese Herbal Medicines and Their Decoctions by Graphite Furnace Atomic Absorption Spectrometry
10
作者 Hanwen Sun Lixin Li 《American Journal of Analytical Chemistry》 2011年第2期217-222,共6页
Lead and cadmium in herbal medicines are highly toxic to living organisms even in low concentrations. An effective method is developed for analysis of trace lead and cadmium in Chinese herbal medicines and their decoc... Lead and cadmium in herbal medicines are highly toxic to living organisms even in low concentrations. An effective method is developed for analysis of trace lead and cadmium in Chinese herbal medicines and their decoctions by graphite furnace atomic absorption spectrometry (GFAAS). The effects of analytical conditions on absorbance were investigated and optimized. A water-dissolving capability for Pb and Cd was investigated, and the contents of different species in five Chinese herbal medicines and their decoctions were analyzed. The content ratios (kow) of n-octanol-soluble Pb or Cd to water-soluble Pb or Cd were evaluated, and the distribution of Pb and Cd in water decoction at stomach and intestine acidities was developed, in the first time. The contents of water-soluble Pb and Cd, n-octanol-soluble Pb and Cd, and their content ratios were related with the kind of medicine and the acidity of the decoction. The proposed method has the advantages of simple operation, high sensitivity and high speed, with 3 σ detection limits of 4.2 pg for Pb and 0.1 pg for Cd. 展开更多
关键词 Distribution Lead Cadmium HERBAL MEDICINES Decoctions graphite furnace atomic absorption SPECTROMETRY
下载PDF
Determination of Heavy Metals at Sub-ppb Levels in Water by Graphite Furnace Atomic Absorption Spectrometry Using a Direct Introduction Technique after Preconcentration with an Iminodiacetate Extraction Disk
11
作者 Tetsuo Inui Atsuko Kosuge +4 位作者 Atsushi Ohbuchi Kazuhiro Fujita Yuya Koike Masaru Kitano Toshihiro Nakamura 《American Journal of Analytical Chemistry》 2012年第10期683-692,共10页
A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels i... A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels in water. A 100 mL water sample was adjusted to pH 5.6 with nitric acid and a 1 mol?L–1 ammonium acetate solution, and then passed through an IED (diameter, 47 mm;effective filtering diameter, 35 mm) at a flow rate of 80 - 100 mL?min–1 to preconcentrate seven analytes. The IED was dried at 100?C for 20 min in an electric oven, and 110 - 145 small disks, each 2 mm in diameter, were punched out from the IED. A small disk was introduced into the graphite furnace and atomized according to a heating program. For Cd, Sn, Pb, and Bi measurements, Pd was used as a chemical modifier to enhance the absorbances. Calibration was performed using aqueous standard solutions. The detection limits, corresponding to three times the standard deviation (n = 5) of the blank values, were 0.092 μg·L–1 for Co, 0.12 μg·L–1 for Ni, 0.40 μg·L–1 for Cu, 0.077 μg·L–1 for Cd, 0.92 μg·L–1 for Sn, 0.61 μg·L–1 for Pb, and 0.80 μg·L–1 for Bi with an enrichment factor of 140 using a 100-mL water sample. A spike test for the seven analytes in tap water, rainwater, river water, and mineral drinking water showed quantitative recoveries (93% - 108%). 展开更多
关键词 Water Sample Heavy Metal PRECONCENTRATION IMINODIACETATE EXTRACTION DISK DIRECT INTRODUCTION Technique graphite furnace atomic absorption Spectrometry
下载PDF
ICP-MS法和GF-AAS法检测乳粉中铬元素的测量系统评价
12
作者 冯灏 苏莹 +3 位作者 耿雅雯 郭青青 林津 周陶鸿 《乳业科学与技术》 2024年第1期19-25,共7页
铬元素是食品质量安全重点监测项目,GB 5009.123—2023《食品安全国家标准食品中铬的测定》中规定了食品中铬的2种常用检验方法:石墨炉原子吸收光谱(graphite furnace atomic absorption spectrometry,GF-AAS)法和电感耦合等离子体质谱(... 铬元素是食品质量安全重点监测项目,GB 5009.123—2023《食品安全国家标准食品中铬的测定》中规定了食品中铬的2种常用检验方法:石墨炉原子吸收光谱(graphite furnace atomic absorption spectrometry,GF-AAS)法和电感耦合等离子体质谱(inductively coupled plasma mass spectrometry,ICP-MS)法。使用Minitab统计分析工具,运用控制图法、独立样件法、t检验法及方差分析法对上述2种常用检验方法测量系统的稳定性、偏倚、线性、重复性与再现性进行分析。结果表明:2种检测方法测量系统极差图和均值图均无异常点,组内误差处于统计受控状态,稳定性良好;量具线性和偏倚分析结果均不存在显著偏倚和显著线性误差;量具R&R报告分析结果表明,ICP-MS法和GF-AAS法测量系统重复性和再现性良好;双因子方差分析表明,样品是唯一显著影响测量误差的因子;研究变异分析表明,测量系统误差可以接受。ICP-MS法和GF-AAS法不仅能有效保障乳粉中铬元素含量检测数据的可靠性和可重复性,为实验室进行测量系统的误差分析与控制提供科学依据,同时也为乳制品中其他重金属检测及其他食品中重金属检测的测量系统评价提供一定参考。 展开更多
关键词 电感耦合等离子体质谱 石墨炉原子吸收光谱 乳粉 Minitab 测量系统
下载PDF
GF-AAS与ICP-MS测定水中总铬含量的方法比对及其不确定度评定 被引量:4
13
作者 赵静 谭亮 +3 位作者 冀恬 任倩雯 李玉林 王环 《净水技术》 CAS 2023年第3期181-188,共8页
石墨炉原子吸收光谱(GF-AAS)法和电感耦合等离子体质谱(ICP-MS)法是灵敏度较高的2种测定水中铬含量的方法。文中采用357.9 nm与429.0 nm波长条件下GF-AAS法、52与53质核比条件下ICP-MS法测定水质铬标准物质中总铬元素含量,从标准曲线、... 石墨炉原子吸收光谱(GF-AAS)法和电感耦合等离子体质谱(ICP-MS)法是灵敏度较高的2种测定水中铬含量的方法。文中采用357.9 nm与429.0 nm波长条件下GF-AAS法、52与53质核比条件下ICP-MS法测定水质铬标准物质中总铬元素含量,从标准曲线、准确性、重复性、加标回收率、检出限、定量限、测量不确定度评定多个方面进行对比分析。结果表明,4组测定条件下,标准物质测定结果均在标准值不确定度范围内。其中,429.0 nm波长GF-AAS法测定结果相对其他3组显著偏低(P<0.05);ICP-MS法在检出限、定量限方面优于GF-AAS法;GF-AAS法测定结果357.9 nm波长优于429.0 nm波长。 展开更多
关键词 石墨炉原子吸收光谱法 电感耦合等离子体质谱法 测量不确定度评定 方法对比
下载PDF
Mechanism of boron atomization in graphite furnace atomic absorption spectroscopy 被引量:1
14
作者 JIANG Yong-Qing YAO Jin-Yu Changchun Institute of Applied Chemistry,Academia Sinica,ChangchunHUANG Ben-Li Department of Chemistry,Xiamen University,Xiamen 《Acta Chimica Sinica English Edition》 SCIE CAS CSCD 1989年第5期437-442,共1页
The mechanism of the atomization of boron and the enhancement of sensitivity by matrix modifier Sr(NO_3)_2 in graphite furnace AAS were discussed.X-ray diffraction and thermodynamic calculation were applied to study t... The mechanism of the atomization of boron and the enhancement of sensitivity by matrix modifier Sr(NO_3)_2 in graphite furnace AAS were discussed.X-ray diffraction and thermodynamic calculation were applied to study the mechanism of boron atomization with and without matrix mo- difier Sr(NO_3)_2.The formation of boron atom is due to the sublimation of solid boron which derived from the reduction of B_2O_3 by carbon.The enhancement of boron signal in the presence of Sr(NO_3)_2 is due to the formation of SrB_6 before atomization,which decreased the volatization losses of B_2O_3 and retarded the formation of B_4C. 展开更多
关键词 Mechanism of boron atomization in graphite furnace atomic absorption spectroscopy
全文增补中
土壤-苦丁茶树系统中铅的GF-AAS测定及其分布特性 被引量:3
15
作者 杜兵兵 罗盛旭 +2 位作者 李辉 吴良 贾振亚 《环境化学》 CAS CSCD 北大核心 2010年第2期310-314,共5页
采集不同苦丁茶树的根、茎、叶及对应的土壤样品,经过清洗、烘干、研磨等预处理后,采用高压密封罐加热消解,加入磷酸氢二铵作为基体改进剂,通过氘灯扣除背景,以石墨炉原子吸收光谱法(GF-AAS)测定样品中的铅,铅浓度在0.000—60.000ng.ml-... 采集不同苦丁茶树的根、茎、叶及对应的土壤样品,经过清洗、烘干、研磨等预处理后,采用高压密封罐加热消解,加入磷酸氢二铵作为基体改进剂,通过氘灯扣除背景,以石墨炉原子吸收光谱法(GF-AAS)测定样品中的铅,铅浓度在0.000—60.000ng.ml-1时与吸光度呈现良好的线性关系,相关系数r=0.9999,检出限为0.200ng.ml-1,方法精密度RSD<5%,回收率93%—107%.用上述方法研究土壤-苦丁茶树系统中铅的分布表明,各种苦丁茶树及土壤中铅的分布具有类似规律,即土壤中铅含量远高于茶树中,茶树的地下部分含量分布为:吸收根>主根,地上部分为:枯叶>茎>老叶>嫩叶,其中嫩叶中铅含量远低于限量指标(Pb≤5.0μg.g-1),对茶叶服用的安全性有利. 展开更多
关键词 苦丁茶树 土壤 石墨炉原子吸收光谱法(GF—AAS).
下载PDF
ICP-MS法和GF-AAS法测定饲料级腐植酸钠中铅、镉、铬含量的比较研究 被引量:6
16
作者 李丽娜 郝晓莉 +2 位作者 卜庆状 张馨予 陈芳 《黑龙江畜牧兽医》 CAS 北大核心 2021年第22期97-102,共6页
为了测定饲料级腐植酸钠中铅、镉、铬三种重金属元素的含量,试验采用全自动石墨消解仪消解腐植酸钠样品后,再分别用电感耦合等离子体质谱(ICP-MS)法和国家标准方法——石墨炉原子吸收光谱(GF-AAS)法测定,同时对这两种方法进行了比较分... 为了测定饲料级腐植酸钠中铅、镉、铬三种重金属元素的含量,试验采用全自动石墨消解仪消解腐植酸钠样品后,再分别用电感耦合等离子体质谱(ICP-MS)法和国家标准方法——石墨炉原子吸收光谱(GF-AAS)法测定,同时对这两种方法进行了比较分析。结果表明:ICP-MS法和GF-AAS法均能对饲料级腐植酸钠中铅、镉、铬三种重金属元素进行很好的分析检测,各元素校正曲线的相关系数均能达到或超过0.9987,线性关系良好;各元素检出限均等于或小于0.0062 mg/kg,灵敏度较高;加标回收率范围在90.1%~104.7%之间,回收率良好;相对标准偏差(RSD)均小于5.00%,精密度高;质控样品测定值的平均值均在标示值范围内,准确性良好。针对铅、镉、铬三种元素的检测,与GF-AAS法相比,ICP-MS法检出限更低,灵敏度更高,加标回收率表现更优,精密度和稳定性更佳。说明ICP-MS法和GF-AAS法均可用于对饲料级腐植酸钠样品中铅、镉、铬三种重金属元素进行分析检测;ICP-MS法具有更低的检出限,更高的灵敏度和更优的加标回收率和精密度,且一次进样可以同时得到多种元素的检测结果,简便快捷,更能满足生产中大批量快速检测的需求。 展开更多
关键词 饲料级腐植酸钠 ICP-MS法 gf-aas 重金属 元素 测定方法
下载PDF
GF-AAS法测定处理污水灌溉土壤中铅最佳基体改进剂的选择及其应用 被引量:7
17
作者 肖开提.阿布力孜 沙尼亚.托乎提 +2 位作者 阿布力孜.伊米提 吉德 史瑞芬 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2008年第6期1410-1412,共3页
研究了石墨炉原子吸收法(GF-AAS法)测定一级处理污水灌溉土壤中铅最佳基体改进剂的选择及在最佳改进剂条件下测定污水灌溉土壤中铅的GF-AAS法。试验了磷酸二氢铵,磷酸铵,氯化铵,Pd-Mg和磷酸二氢铵+硝酸镁+硝酸铵等基体改进剂对测定... 研究了石墨炉原子吸收法(GF-AAS法)测定一级处理污水灌溉土壤中铅最佳基体改进剂的选择及在最佳改进剂条件下测定污水灌溉土壤中铅的GF-AAS法。试验了磷酸二氢铵,磷酸铵,氯化铵,Pd-Mg和磷酸二氢铵+硝酸镁+硝酸铵等基体改进剂对测定一级处理污水灌溉土壤铅的基体改进作用,并根据基体改进剂的改进效果,最佳灰化温度和原子化温度,选定了最佳基体改进剂和测定条件。40 g·L^-1的磷酸二氢铵作为基体改进剂,灰化温度为850℃,原子化温度为1 600℃时,用氘灯校正背景GF-AAS法进行测定,测定方法的RSD为2.6%,回收率在92.4%-104%之内。 展开更多
关键词 石墨炉原子吸收法 基体改进剂
下载PDF
GF-AAS法测定庐山区农村饮用水中铅、镉的含量 被引量:1
18
作者 涂希翊 赵建国 +2 位作者 曲伟红 张磊 石向群 《广州化工》 CAS 2015年第5期133-135,共3页
通过对庐山区农村饮用水进行抽样测定了重金属Pb、Cd的含量,分析重金属Pb、Cd的污染情况。选取有代表性的水样28份,采用石墨炉原子吸收光谱法(GF-AAS)测定饮用其中Pb、Cd的含量。结果表明:28份水样中所含Pb量为(0.2386±0.4124)μg/... 通过对庐山区农村饮用水进行抽样测定了重金属Pb、Cd的含量,分析重金属Pb、Cd的污染情况。选取有代表性的水样28份,采用石墨炉原子吸收光谱法(GF-AAS)测定饮用其中Pb、Cd的含量。结果表明:28份水样中所含Pb量为(0.2386±0.4124)μg/L,Cd量为(0.0984±0.1456)μg/L。根据《生活饮用水卫生标准》(GB/T5750-2006),Pb限度为10μg/L,Cd限度为5μg/L,28份样本所测的重金属均在其限度范围内,表明庐山区农村饮用水没有重金属Pb、Cd的污染。 展开更多
关键词 饮用水 石墨炉 原子吸收光谱法 PB CD
下载PDF
微波消解-GF-AAS测定荸荠及荸荠皮中的铅和镉 被引量:3
19
作者 唐昭领 包秘 +6 位作者 王蕾 盛志宇 涂秀红 李慧静 莫秋云 罗晓慧 陶剑恒 《食品研究与开发》 CAS 北大核心 2017年第21期150-153,共4页
采用微波消解样品,石墨炉原子吸收光谱法测定荸荠及荸荠皮中铅和镉的含量。选定最佳的样品处理方法,并优化微波消解条件和仪器测定条件,对各种最佳分析条件进行了探讨和验证。研究表明,铅、镉的检出限分别为0.171、0.026μg/L;线性范围... 采用微波消解样品,石墨炉原子吸收光谱法测定荸荠及荸荠皮中铅和镉的含量。选定最佳的样品处理方法,并优化微波消解条件和仪器测定条件,对各种最佳分析条件进行了探讨和验证。研究表明,铅、镉的检出限分别为0.171、0.026μg/L;线性范围分别为0~60μg/L、0~4.0μg/L;加标回收率分别为94.0%~101.0%、92.0%~106.0%;RSD分别为4.2%、3.7%。用标准物质进行对照,其测定值均在给定的标准值范围内。 展开更多
关键词 微波消解 石墨炉原子吸收光谱法 荸荠 荸荠皮
下载PDF
SS-GF-AAS法测定冬虫夏草中的铜元素 被引量:1
20
作者 王娟珍 薛长安 马健 《宝鸡文理学院学报(自然科学版)》 CAS 2013年第1期31-34,共4页
目的研究冬虫夏草中铜的含量。方法利用石墨炉原子吸收法,采取固体直接进样(solid sampling-graphite furnace-atomic absorption spectrometry,SS-GF-AAS)对冬虫夏草发酵菌丝体粉中的铜元素进行分析测定。结果 SS-GF-AAS实验结果显示,... 目的研究冬虫夏草中铜的含量。方法利用石墨炉原子吸收法,采取固体直接进样(solid sampling-graphite furnace-atomic absorption spectrometry,SS-GF-AAS)对冬虫夏草发酵菌丝体粉中的铜元素进行分析测定。结果 SS-GF-AAS实验结果显示,冬虫夏草发酵菌丝体粉中的铜元素含量在6.45~7.24mg/kg之间,平行样品的重复性相对偏差(RSD)为0.63%~5.37%,样品的日间重现性RSD为4.43%,此方法的回收率范围为91.19%~110.62%。结论该方法重现性良好,其测定结果的精密度及重现性可以同常用的液体原子吸收分光光度法相媲美。 展开更多
关键词 冬虫夏草 CU 石墨炉原子吸收法 固体直接进样
下载PDF
上一页 1 2 101 下一页 到第