It is significant to research the voltage stability of the wind power centralized system (WPCS) for the effective development of the large scale clustering wind energy resources. A steady state voltage stability analy...It is significant to research the voltage stability of the wind power centralized system (WPCS) for the effective development of the large scale clustering wind energy resources. A steady state voltage stability analysis of the WPCS by employing the PV curve and model analysis is proposed to reveal the voltage stability influence from different aspects. The PV curve is utilized to trace and indicate the voltage collapse point of the WPCS when the small disturbance of wind power is increased gradually. Then the steady state voltage instability modes of the WPCS are analyzed by calculating the bus participation factors of the minimum eigenvalue model at the collapse point. The simulation results of an actual WPCS in North China show that the static state voltage instability mode of the WPCS is closely related to the operating features and control strategies of different reactive power sources. In addition, the implementation of the doubly-fed induction generator wind turbine generator voltage control is beneficial to improve the WPCS voltage stability.展开更多
为提高风电并网系统中电网侧逆变器直流母线电压的稳定性和动态响应速度,文中设计一种无对象模型辅助的二阶线性自抗扰控制技术(linear active disturbance rejection control,ADRC)以取代电压外环的PI控制器,从而形成一种新的双闭环控...为提高风电并网系统中电网侧逆变器直流母线电压的稳定性和动态响应速度,文中设计一种无对象模型辅助的二阶线性自抗扰控制技术(linear active disturbance rejection control,ADRC)以取代电压外环的PI控制器,从而形成一种新的双闭环控制结构。文中利用频域分析法分析了ADRC控制器的稳定性、跟踪性和抗扰能力;最后在3.6 MW直驱永磁同步风力发电机组的物理实验平台中验证了该控制结构的可行性,将传统PI控制和文中所提出的控制模式在不同工作条件下的控制效果进行比较。实验结果表明,该文章设计的控制方案优于传统的PI控制器,具有良好的抗干扰性和鲁棒性,大大减少直流侧母线电压波动所造成的影响。展开更多
随着大量新能源场站接入交直流混联电网,系统的静态电压稳定裕度(static voltage stability margin,SVSM)水平具有很大的不确定性,需要研究考虑新能源场站高阶不确定性的交直流混联电网SVSM计算方法。针对此问题,首先建立了交直流混联电...随着大量新能源场站接入交直流混联电网,系统的静态电压稳定裕度(static voltage stability margin,SVSM)水平具有很大的不确定性,需要研究考虑新能源场站高阶不确定性的交直流混联电网SVSM计算方法。针对此问题,首先建立了交直流混联电网SVSM计算模型,模型中考虑了直流换流站控制方式随负荷增长的切换;采用概率盒模型描述风速与光照强度的随机波动,提出了改进区间半不变量法以获得更准确的SVSM概率盒,该方法通过K-means++聚类算法将随机变量样本划分为多个波动范围较小的样本集,以降低半不变量的线性化计算带来的误差;并结合Gram-Charlier级数展开和概率加权和计算得到考虑新能源场站高阶不确定性的系统SVSM概率盒。通过对修改的IEEE-39节点交直流系统和南方电网两个算例的分析,并与区间半不变量法和双层蒙特卡洛法比较,验证了所提出方法获得的SVSM概率盒具有较高的计算精度和效率。展开更多
集中送出的新能源场站大多位于电网末端,随着其有功出力的增加,易出现静态电压失稳。该文将传统的阻抗模指标的应用对象由负荷推广至新能源场站,丰富了该指标在静态电压稳定评估方面的适用性场景,包括含无功补偿的新能源系统、新能源集...集中送出的新能源场站大多位于电网末端,随着其有功出力的增加,易出现静态电压失稳。该文将传统的阻抗模指标的应用对象由负荷推广至新能源场站,丰富了该指标在静态电压稳定评估方面的适用性场景,包括含无功补偿的新能源系统、新能源集群馈入系统、以及新能源多机多馈入系统。具体地,首先,分析新能源单馈入系统的临界静态电压稳定条件,并据此给出用于评估新能源场站静态电压稳定性的阻抗模裕度指标及稳定判据;其次,通过将无功补偿设备并入系统阻抗,分析无功补偿对于指标的影响;再次,证明在新能源的集群馈入系统中,公共耦合点(point of common coupling,PCC)的电压失稳将发生在单个新能源场站之前,并据此确定PCC点作为指标的计算节点;之后,为考虑多机多馈入系统中不同新能源场站间的影响,在指标的计算过程中,保留待评估的关键新能源场站,将其他新能源场站等值为阻抗,并入节点阻抗矩阵中,实现方法在多机多馈入系统中的扩展应用。最后,基于PSD-BPA中建立的单机单馈入系统、多机多馈入系统、以及某省实际大电网算例验证指标的有效性。展开更多
文摘It is significant to research the voltage stability of the wind power centralized system (WPCS) for the effective development of the large scale clustering wind energy resources. A steady state voltage stability analysis of the WPCS by employing the PV curve and model analysis is proposed to reveal the voltage stability influence from different aspects. The PV curve is utilized to trace and indicate the voltage collapse point of the WPCS when the small disturbance of wind power is increased gradually. Then the steady state voltage instability modes of the WPCS are analyzed by calculating the bus participation factors of the minimum eigenvalue model at the collapse point. The simulation results of an actual WPCS in North China show that the static state voltage instability mode of the WPCS is closely related to the operating features and control strategies of different reactive power sources. In addition, the implementation of the doubly-fed induction generator wind turbine generator voltage control is beneficial to improve the WPCS voltage stability.
文摘随着大量新能源场站接入交直流混联电网,系统的静态电压稳定裕度(static voltage stability margin,SVSM)水平具有很大的不确定性,需要研究考虑新能源场站高阶不确定性的交直流混联电网SVSM计算方法。针对此问题,首先建立了交直流混联电网SVSM计算模型,模型中考虑了直流换流站控制方式随负荷增长的切换;采用概率盒模型描述风速与光照强度的随机波动,提出了改进区间半不变量法以获得更准确的SVSM概率盒,该方法通过K-means++聚类算法将随机变量样本划分为多个波动范围较小的样本集,以降低半不变量的线性化计算带来的误差;并结合Gram-Charlier级数展开和概率加权和计算得到考虑新能源场站高阶不确定性的系统SVSM概率盒。通过对修改的IEEE-39节点交直流系统和南方电网两个算例的分析,并与区间半不变量法和双层蒙特卡洛法比较,验证了所提出方法获得的SVSM概率盒具有较高的计算精度和效率。
文摘集中送出的新能源场站大多位于电网末端,随着其有功出力的增加,易出现静态电压失稳。该文将传统的阻抗模指标的应用对象由负荷推广至新能源场站,丰富了该指标在静态电压稳定评估方面的适用性场景,包括含无功补偿的新能源系统、新能源集群馈入系统、以及新能源多机多馈入系统。具体地,首先,分析新能源单馈入系统的临界静态电压稳定条件,并据此给出用于评估新能源场站静态电压稳定性的阻抗模裕度指标及稳定判据;其次,通过将无功补偿设备并入系统阻抗,分析无功补偿对于指标的影响;再次,证明在新能源的集群馈入系统中,公共耦合点(point of common coupling,PCC)的电压失稳将发生在单个新能源场站之前,并据此确定PCC点作为指标的计算节点;之后,为考虑多机多馈入系统中不同新能源场站间的影响,在指标的计算过程中,保留待评估的关键新能源场站,将其他新能源场站等值为阻抗,并入节点阻抗矩阵中,实现方法在多机多馈入系统中的扩展应用。最后,基于PSD-BPA中建立的单机单馈入系统、多机多馈入系统、以及某省实际大电网算例验证指标的有效性。