A 10-channel Hα diagnostic system has been designed with the rapid response rate of 300 kHz, spatial resolution of about 40 mm, and overlap between adjacent channels of about 3%, and it has been implemented successfu...A 10-channel Hα diagnostic system has been designed with the rapid response rate of 300 kHz, spatial resolution of about 40 mm, and overlap between adjacent channels of about 3%, and it has been implemented successfully on Keda Torus eXperiment(KTX), a newly constructed, reversed field pinch(RFP) experimental device at the University of Science and Technology of China(USTC). This diagnostic system is a very important tool for the initial KTX operations. It is compact,with an aperture slit replacing the traditional optical lens system. A flexural interference filter is designed to prevent the center wavelength from shifting too much as the increase of angle from vertical incidence. To eliminate the stray light,the interior of the system is covered with the black aluminum foil having a very high absorptivity. Using the Hαemission data, together with the profiles of electron temperature and density obtained from the Langmuir probe, the neutral density profiles have been calculated for KTX plasmas. The rapid response rate and good spatial resolution of this Hαdiagnostic system will be beneficial for many studies in RFP plasma physics.展开更多
This paper reports on the installation and observations of a new solar telescope installed on 2014 October 7 at the Kodaikanal Observatory. The telescope is a refractive type equipped with a tunable Lyot Hα filter. A...This paper reports on the installation and observations of a new solar telescope installed on 2014 October 7 at the Kodaikanal Observatory. The telescope is a refractive type equipped with a tunable Lyot Hα filter. A CCD camera with size 2k ×2k acquires images of the Sun and has a pixel size of 1.21″ pixel^-1 and a full field-of-view of 41'. The telescope is equipped with a guiding system which keeps the image of the Sun within a few pixels throughout the observations. The FWHM of the Lyot filter is 0.4A and the filter is motorized, capable of scanning the Hα line profile at a smaller step size of 0.01 A. Partial-disk imaging covering about 10' is also possible with the help of a relay lens kept in front of the CCD camera. In this paper, we report the detailed specifications of the telescope, filter unit, the installation, observations and the procedures we have followed to calibrate and align the data. We also present preliminary results with this new full-disk telescope.展开更多
基金Project supported by the National Magnetic Confinement Fusion Science Program of China(Grant No.2017YFE0301700)the National Natural Science Foundation of China(Grant No.11635008)
文摘A 10-channel Hα diagnostic system has been designed with the rapid response rate of 300 kHz, spatial resolution of about 40 mm, and overlap between adjacent channels of about 3%, and it has been implemented successfully on Keda Torus eXperiment(KTX), a newly constructed, reversed field pinch(RFP) experimental device at the University of Science and Technology of China(USTC). This diagnostic system is a very important tool for the initial KTX operations. It is compact,with an aperture slit replacing the traditional optical lens system. A flexural interference filter is designed to prevent the center wavelength from shifting too much as the increase of angle from vertical incidence. To eliminate the stray light,the interior of the system is covered with the black aluminum foil having a very high absorptivity. Using the Hαemission data, together with the profiles of electron temperature and density obtained from the Langmuir probe, the neutral density profiles have been calculated for KTX plasmas. The rapid response rate and good spatial resolution of this Hαdiagnostic system will be beneficial for many studies in RFP plasma physics.
文摘This paper reports on the installation and observations of a new solar telescope installed on 2014 October 7 at the Kodaikanal Observatory. The telescope is a refractive type equipped with a tunable Lyot Hα filter. A CCD camera with size 2k ×2k acquires images of the Sun and has a pixel size of 1.21″ pixel^-1 and a full field-of-view of 41'. The telescope is equipped with a guiding system which keeps the image of the Sun within a few pixels throughout the observations. The FWHM of the Lyot filter is 0.4A and the filter is motorized, capable of scanning the Hα line profile at a smaller step size of 0.01 A. Partial-disk imaging covering about 10' is also possible with the help of a relay lens kept in front of the CCD camera. In this paper, we report the detailed specifications of the telescope, filter unit, the installation, observations and the procedures we have followed to calibrate and align the data. We also present preliminary results with this new full-disk telescope.