期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Analytical Investigation into the Rotational Performance of Glulam Bolted Beam-Column Connections under Coupled Bending Moment and Shear Force
1
作者 Xiaofeng Zhang Lisheng Luo +2 位作者 Youfu Sun Xinyue Cui Yongqiang Zhang 《Journal of Renewable Materials》 SCIE EI 2023年第4期2033-2054,共22页
Considering the glulam beam-column connection form and the number of bolts,monotonic loading test and finite element analysis was carried out on 9 connection specimens in 3 groups to study the rotational performance a... Considering the glulam beam-column connection form and the number of bolts,monotonic loading test and finite element analysis was carried out on 9 connection specimens in 3 groups to study the rotational performance and failure mode of the connection.The test results revealed that compared with U-shaped connectors,T-shaped connectors can effectively improve the ductility of connections,and the increase in the number of bolts can reduce the initial stiffness and ductility of connections.By theoretical analysis,formulas for calculating the initial stiffness and ultimate moment of connections were deduced.Subsequently,the moment-rotation theoretical model of connections was established based on the formulas,which were validated according to the test data and simulation results.The proposed model can not only improve the current theoretical system of heavy-duty glulam beam-column structure but also provide a theoretical basis for calculating the mechanical properties of the glulam beam-column connection. 展开更多
关键词 beam-column connection mechanical properties STIFFNESS ultimate moment
下载PDF
Seismic Behavior of Diaphragm-Through Connections of Concrete-Filled Square Steel Tubular Columns and H-Shaped Steel Beams 被引量:6
2
作者 荣彬 陈志华 +1 位作者 Apostolos Fafitis 苗纪奎 《Transactions of Tianjin University》 EI CAS 2013年第3期195-201,共7页
Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and us... Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections. 展开更多
关键词 concrete-filled square STEEL TUBULAR COLUMN h-shaped STEEL beam diaphragm-through connection seismic behavior load transfer mechanism
下载PDF
Seismic performance of interior precast concrete beam-column connections with T-section steel inserts under cyclic loading 被引量:15
3
作者 Rattapon Ketiyot Chayanon Hansapinyo 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期355-369,共15页
An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/... An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/3-scale interior beam-column subassemblies,one monolithic concrete specimen and five precast concrete specimens were tested.One precast specimen was a simple connection for a gravity load resistant design.Other precast specimens were developed with different attributes to improve their seismic performance.The test results showed that the performance of the monolithic specimen M1 represented ductile seismic behavior.Failure of columns and joints could be prevented,and the failure of the frame occurred at the flexural plastic hinge formation at the beam ends,close to the column faces.For the precast specimens,the splitting crack along the longitudinal lapped splice was a major failure.The precast P5 specimen with double steel T-section inserts showed better seismic performance compared to the other precast models.However,the dowel bars connected to the steel inserts were too short to develop a bond.The design of the precast concrete beams with lap splice is needed for longer lap lengths and should be done at the beam mid span or at the low flexural stress region. 展开更多
关键词 precast concrete beam-column connection cyclic loading
下载PDF
Influence of the column-to-beam flexural strength ratio on the failure mode of beam-column connections in RC frames 被引量:1
4
作者 Gong Maosheng Zuo Zhanxuan +2 位作者 Sun Jing He Riteng Zhao Yinan 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第2期441-452,共12页
The column-to-beam flexural strength ratio(CBFSR)has been used in many seismic codes to achieve the strong column-weak beam(SCWB)failure mode in reinforced concrete(RC)frames,in which plastic hinges appear earlier in ... The column-to-beam flexural strength ratio(CBFSR)has been used in many seismic codes to achieve the strong column-weak beam(SCWB)failure mode in reinforced concrete(RC)frames,in which plastic hinges appear earlier in beams than in columns.However,seismic investigations show that the required limit of CBFSR in seismic codes usually cannot achieve the SCWB failure mode under strong earthquakes.This study investigates the failure modes of RC frames with different CBFSRs.Nine typical three-story RC frame models with different CBFSRs are designed in accordance with Chinese seismic codes.The seismic responses and failure modes of the frames are investigated through time-history analyses using 100 ground motion records.The results show that the required limit of the CBFSR that guarantees the SCWB failure mode depends on the beam-column connection type and the seismic intensity,and different types of beam-column connections exhibit different failure modes even though they are designed with the same CBFSR.Recommended CBFSRs are proposed for achieving the designed SCWB failure mode for different types of connections in RC frames under different seismic intensities.These results may provide some reference for further revisions of the SCWB design criterion in Chinese seismic codes. 展开更多
关键词 strong column-weak beam column-to-beam flexural strength ratio reinforced concrete frame structure beam-column connection failure mode
下载PDF
Seismic retrofitting of severely damaged RC connections made with recycled concrete using CFRP sheets 被引量:2
5
作者 Yasmin MURAD Wassel AL BODOUR Ahmed ASHTEYAT 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2020年第2期554-568,共15页
An experimental and numerical program is carried out in this research to investigate the influence of CFRP sheets on the cyclic behavior of unconfined connections made with recycled concrete.Cement is partially replac... An experimental and numerical program is carried out in this research to investigate the influence of CFRP sheets on the cyclic behavior of unconfined connections made with recycled concrete.Cement is partially replaced by silica fume,iron flling and pulverised fuel ash using two different percentages:15%and 20%.Each specimen is partially loaded at the first stage and then specimens are repaired using CFRP sheets.The repaired specimens are then laterally loaded until failure.In addition,a finite element model is built in ABAQUS and verfed using the experimental results.The experimental results have shown that the repaired specimens have regained almost double the capacity of the un-repaired specimens and hence the adopted repair configuration is recommended for retroftting seismically vulnerable RC connections.Increasing cement replacement percentage by silica fume,fuel ash or iron flling from 15%to 20%has reduced joint carrying capacity and weakened the joint.It is recommended using 15%pulverised fuel ash or silica fume as cement partial replacement to enhance the strength and ultimate drift of beam-column joints under cyclic loading.Iron filling concrete is also recommended but the enhancement is relatively less than that found with pulverised fuel ash concrete and silica fume concrete. 展开更多
关键词 retrofitting CFRP sheets recycled concrete pulverised fuel ash silica fume CYCLIC beam-column connections
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部