H-steel all-bolted connection steel frame structures with heat preservation and decoration composite wall boards were investigated and the seismic performances of three scaled specimens were studied.The failure modes,...H-steel all-bolted connection steel frame structures with heat preservation and decoration composite wall boards were investigated and the seismic performances of three scaled specimens were studied.The failure modes,hysteresis curves,bearing capacity,ductility,energy dissipation capacity,stiffness degradation and strain distribution were discussed.The calculation method of structural theoretical internal force was presented.The results showed that the overall structural seismic performance was better,and the structural ductility met the demands of elastic-plastic inter-story drift angle for seismic design.The H-steel weak-axis connection structure obtained better energy dissipation capacity,and its bearing capacity and stiffness were slightly different from the strong-axis connection.The heat preservation and decoration performance of composite wallboard and the all-bolted connection of the steel frame realized prefabrication during the whole construction period.The plastic hinge of the steel beam can be moved outwards because of the L-angles,which effectively avoids stress concentration in joint areas and expands the plastic hinge range.The errors between the theoretical structural capacity calculated by the plastic analysis method and the test results were within 2.44%.In addition,structural failure mechanisms and bearing capacities were verified by the finite element(FE)analysis,and the effects of the main parameters on the structures were investigated.The FE verification results were the same as in the test.The research results provide theoretical support and technical guidance for the application of thermal insulation and decorative composite wall panels in H-shaped steel all-bolted steel frames.展开更多
In order to investigate shear carrying capacity of H-steel concrete beam with small shear span ratio,shear test on 5 H-steel concrete composite beams with small span ratio (from 0.7 to 1.1) are reported,including test...In order to investigate shear carrying capacity of H-steel concrete beam with small shear span ratio,shear test on 5 H-steel concrete composite beams with small span ratio (from 0.7 to 1.1) are reported,including test design,test scheme,test method,failure characteristics and test results. Influences of shear span ratio,web of H steel and concrete on shear carrying capacity of this kind of beam are investigated. The main components comprising shear bearing capacity are analyzed. The results show that with the shear span ratio increasing,the contribution of web of H steel and concrete on shear carrying capacity decrease. Based on test data,the calculation formula of shear carrying capacity for this beam is established by curve fitting.展开更多
采用LEICA DIM5000M光学显微镜、ZEISS SUPRA 55场发射扫描电镜和OXFORD能谱仪,检测SPA-H耐候钢表面氧化铁皮缺陷并分析了产生原因,采取降低加热段和均热段加热温度、RDT温度,缩短板坯在炉时间,提高上线轧辊辊面质量,合理控制炉后除鳞...采用LEICA DIM5000M光学显微镜、ZEISS SUPRA 55场发射扫描电镜和OXFORD能谱仪,检测SPA-H耐候钢表面氧化铁皮缺陷并分析了产生原因,采取降低加热段和均热段加热温度、RDT温度,缩短板坯在炉时间,提高上线轧辊辊面质量,合理控制炉后除鳞和机架间除鳞水压力和喷嘴安装角度等措施后,SPA-H耐候钢表面氧化铁皮缺陷率由0.83%降至0.07%,约降低91.6%。展开更多
文摘H-steel all-bolted connection steel frame structures with heat preservation and decoration composite wall boards were investigated and the seismic performances of three scaled specimens were studied.The failure modes,hysteresis curves,bearing capacity,ductility,energy dissipation capacity,stiffness degradation and strain distribution were discussed.The calculation method of structural theoretical internal force was presented.The results showed that the overall structural seismic performance was better,and the structural ductility met the demands of elastic-plastic inter-story drift angle for seismic design.The H-steel weak-axis connection structure obtained better energy dissipation capacity,and its bearing capacity and stiffness were slightly different from the strong-axis connection.The heat preservation and decoration performance of composite wallboard and the all-bolted connection of the steel frame realized prefabrication during the whole construction period.The plastic hinge of the steel beam can be moved outwards because of the L-angles,which effectively avoids stress concentration in joint areas and expands the plastic hinge range.The errors between the theoretical structural capacity calculated by the plastic analysis method and the test results were within 2.44%.In addition,structural failure mechanisms and bearing capacities were verified by the finite element(FE)analysis,and the effects of the main parameters on the structures were investigated.The FE verification results were the same as in the test.The research results provide theoretical support and technical guidance for the application of thermal insulation and decorative composite wall panels in H-shaped steel all-bolted steel frames.
基金Sponsored by the National Key Technologies R&D Program of China during the 11th Five-Year Plan Period (Grant No.2006BAJ03A10)"New Century Excellent Talents in University"Scheme (Grant No.290)+2 种基金the National Natural Science Foundation of China(Grant No.50178026)the Natural Science Foundation of Heilongjiang Province-General Project (Grant No.E200806)the Foundation of Harbin Program (Grant No.2005AFXXJ017)
文摘In order to investigate shear carrying capacity of H-steel concrete beam with small shear span ratio,shear test on 5 H-steel concrete composite beams with small span ratio (from 0.7 to 1.1) are reported,including test design,test scheme,test method,failure characteristics and test results. Influences of shear span ratio,web of H steel and concrete on shear carrying capacity of this kind of beam are investigated. The main components comprising shear bearing capacity are analyzed. The results show that with the shear span ratio increasing,the contribution of web of H steel and concrete on shear carrying capacity decrease. Based on test data,the calculation formula of shear carrying capacity for this beam is established by curve fitting.
文摘采用LEICA DIM5000M光学显微镜、ZEISS SUPRA 55场发射扫描电镜和OXFORD能谱仪,检测SPA-H耐候钢表面氧化铁皮缺陷并分析了产生原因,采取降低加热段和均热段加热温度、RDT温度,缩短板坯在炉时间,提高上线轧辊辊面质量,合理控制炉后除鳞和机架间除鳞水压力和喷嘴安装角度等措施后,SPA-H耐候钢表面氧化铁皮缺陷率由0.83%降至0.07%,约降低91.6%。