变电站电压无功控制是电网混成自动电压控制(hybrid automatic voltage control,HAVC)系统的重要组成部分,其控制措施一般包括变电站有载调压变压器(OLTC)的调节和站内电容电抗器的投切等.变电站电压无功控制器设计是一个典型的多目标...变电站电压无功控制是电网混成自动电压控制(hybrid automatic voltage control,HAVC)系统的重要组成部分,其控制措施一般包括变电站有载调压变压器(OLTC)的调节和站内电容电抗器的投切等.变电站电压无功控制器设计是一个典型的多目标优化问题,即在调控过程中,既要控制无功及电压尽量接近设定值,又必须使OLTC的调节次数和电容电抗器的投切次数尽量少.因此,本文首先建立了HAVC系统变电站电压无功控制的多目标优化模型,然后求解该多目标优化问题得到变电站电压无功优化控制策略.对东北电网沙岭变电站的仿真分析证明了所提出的控制策略的有效性和正确性.展开更多
This paper probes into the feasibility of equilibrating pressure of water distribution network through (using auto-control valves) in theory and in the economy. An optimal valve control model is designed to minimize t...This paper probes into the feasibility of equilibrating pressure of water distribution network through (using auto-control valves) in theory and in the economy. An optimal valve control model is designed to minimize the sum of squares of residual pressure in the network. Such an analog simulation has been performed on the year 2003 programming network of a certain littoral district in North China, through which this paper confirms that it is feasible to equilibrate pressure with auto-control valves in theory. The research work has brought about a discovery of applicable conditions of valves in economic feasibility, which avoids a great economic loss due to the wild use of auto-control valve. In addition, simulated annealing algorithm is applied to optimize valve settings and shown to identify global optimum or near-optimum.展开更多
In order to overcome the low precision and weak applicability problems of the current municipal water network state simulation model, the water network structure is studied. Since the telemetry system has been applied...In order to overcome the low precision and weak applicability problems of the current municipal water network state simulation model, the water network structure is studied. Since the telemetry system has been applied increasingly in the water network, and in order to reflect the network operational condition more accurately, a new water network macroscopic model is developed by taking the auto-control adjusting valve opening state into consideration. Then for highly correlated or collinear independent variables in the model, the partial least squares (PLS) regression method provides a model solution which can distinguish between the system information and the noisy data. Finally, a hypothetical water network is introduced for validating the model. The simulation results show that the relative error is less than 5.2%, indicating that the model is efficient and feasible, and has better generalization performance.展开更多
文摘变电站电压无功控制是电网混成自动电压控制(hybrid automatic voltage control,HAVC)系统的重要组成部分,其控制措施一般包括变电站有载调压变压器(OLTC)的调节和站内电容电抗器的投切等.变电站电压无功控制器设计是一个典型的多目标优化问题,即在调控过程中,既要控制无功及电压尽量接近设定值,又必须使OLTC的调节次数和电容电抗器的投切次数尽量少.因此,本文首先建立了HAVC系统变电站电压无功控制的多目标优化模型,然后求解该多目标优化问题得到变电站电压无功优化控制策略.对东北电网沙岭变电站的仿真分析证明了所提出的控制策略的有效性和正确性.
文摘This paper probes into the feasibility of equilibrating pressure of water distribution network through (using auto-control valves) in theory and in the economy. An optimal valve control model is designed to minimize the sum of squares of residual pressure in the network. Such an analog simulation has been performed on the year 2003 programming network of a certain littoral district in North China, through which this paper confirms that it is feasible to equilibrate pressure with auto-control valves in theory. The research work has brought about a discovery of applicable conditions of valves in economic feasibility, which avoids a great economic loss due to the wild use of auto-control valve. In addition, simulated annealing algorithm is applied to optimize valve settings and shown to identify global optimum or near-optimum.
基金Supported by Tianjin Natural Science Foundation( No. 003611611).
文摘In order to overcome the low precision and weak applicability problems of the current municipal water network state simulation model, the water network structure is studied. Since the telemetry system has been applied increasingly in the water network, and in order to reflect the network operational condition more accurately, a new water network macroscopic model is developed by taking the auto-control adjusting valve opening state into consideration. Then for highly correlated or collinear independent variables in the model, the partial least squares (PLS) regression method provides a model solution which can distinguish between the system information and the noisy data. Finally, a hypothetical water network is introduced for validating the model. The simulation results show that the relative error is less than 5.2%, indicating that the model is efficient and feasible, and has better generalization performance.