The beam-based alignment system is given in HLS (Hefei Light Source), in which a switchable shunt resistorwas installed on quadrupole to bypass a small percentage of the magnet current. The system can measureBPM-to-qu...The beam-based alignment system is given in HLS (Hefei Light Source), in which a switchable shunt resistorwas installed on quadrupole to bypass a small percentage of the magnet current. The system can measureBPM-to-quadrupole offset which can be used to position the beam in the magnetic center of quadrupoles. In measurement,some methods ( linear fitting with single corrector, parabola fitting with single corrector, linear fitting withlocal bump, and parabola fitting with local bump ) are used. These measurement results are given, and comparedamong the methods mentioned above.展开更多
To upgrade Hefei Light Source(HLS) Linac, eight accelerating units have been constructed to realize fullenergy injection of the storage ring. Each of the units consists of two 3-m accelerators driven by one klystron.T...To upgrade Hefei Light Source(HLS) Linac, eight accelerating units have been constructed to realize fullenergy injection of the storage ring. Each of the units consists of two 3-m accelerators driven by one klystron.The input cavity detuning method was developed to measure and correct the phase length of the RF power distribution waveguide system. The design of the waveguide network and the principles of the detuning method are presented in this paper. After correction, the phase error between the waveguide of the two accelerators was less than ±0.5?, and the maximum electron energy of Linac reached 805 MeV, which is very near the theoretical maximum value of 810 MeV. These results demonstrate that the calibration of the waveguide was successful.展开更多
In this paper,in order to stabilize the position and angle of the light source point,a new photon beam position feedback system based on the Photon Beam Position Monitors was developed on Hefei Light Source,and used t...In this paper,in order to stabilize the position and angle of the light source point,a new photon beam position feedback system based on the Photon Beam Position Monitors was developed on Hefei Light Source,and used to correct the position drift and angle variation of the light source at the same time.On introducing the feedback principle,the transfer function matrix is calibrated,indicating that the new system is workable and effective.展开更多
The Ethernet and field-bus communications are used in the machine control system (MCS) of HL-2A. The control net, with a programmable logic controller (PLC) as its logic control master, an engineering control mana...The Ethernet and field-bus communications are used in the machine control system (MCS) of HL-2A. The control net, with a programmable logic controller (PLC) as its logic control master, an engineering control management station as its net server, and a timing control PC connected to a number of terminals, flexibly and freely transfers information among the nodes on it with the Ethernet transmission techniques. The PLC masters the field bus, which carries small pieces of information between PLC and the field sites reliably and quickly. The control net is connected into the data net, where Internet access and sharing of more experimental data are enabled. The communication in the MCS guarantees the digitalization, automation and centralization. Also provided are a satisfactory degree of safety, reliability, stability, expandability and flexibility for maintenance.展开更多
文摘The beam-based alignment system is given in HLS (Hefei Light Source), in which a switchable shunt resistorwas installed on quadrupole to bypass a small percentage of the magnet current. The system can measureBPM-to-quadrupole offset which can be used to position the beam in the magnetic center of quadrupoles. In measurement,some methods ( linear fitting with single corrector, parabola fitting with single corrector, linear fitting withlocal bump, and parabola fitting with local bump ) are used. These measurement results are given, and comparedamong the methods mentioned above.
基金Supported by National Natural Science Foundation of China(No.11079034)
文摘To upgrade Hefei Light Source(HLS) Linac, eight accelerating units have been constructed to realize fullenergy injection of the storage ring. Each of the units consists of two 3-m accelerators driven by one klystron.The input cavity detuning method was developed to measure and correct the phase length of the RF power distribution waveguide system. The design of the waveguide network and the principles of the detuning method are presented in this paper. After correction, the phase error between the waveguide of the two accelerators was less than ±0.5?, and the maximum electron energy of Linac reached 805 MeV, which is very near the theoretical maximum value of 810 MeV. These results demonstrate that the calibration of the waveguide was successful.
基金Supported by National Natural Science Foundation of China(No.10675118,and No.11175173)
文摘In this paper,in order to stabilize the position and angle of the light source point,a new photon beam position feedback system based on the Photon Beam Position Monitors was developed on Hefei Light Source,and used to correct the position drift and angle variation of the light source at the same time.On introducing the feedback principle,the transfer function matrix is calibrated,indicating that the new system is workable and effective.
基金The project supported by National Natural Science Foundation of China (No. 10175022) and Sichuan Provincial Youth Foundation
文摘The Ethernet and field-bus communications are used in the machine control system (MCS) of HL-2A. The control net, with a programmable logic controller (PLC) as its logic control master, an engineering control management station as its net server, and a timing control PC connected to a number of terminals, flexibly and freely transfers information among the nodes on it with the Ethernet transmission techniques. The PLC masters the field bus, which carries small pieces of information between PLC and the field sites reliably and quickly. The control net is connected into the data net, where Internet access and sharing of more experimental data are enabled. The communication in the MCS guarantees the digitalization, automation and centralization. Also provided are a satisfactory degree of safety, reliability, stability, expandability and flexibility for maintenance.