Internal fixator vs external fixator in the management of unstable pelvic ring injuries:A prospective comparative cohort study 被引量:1
1
作者 Mohamed Abo-Elsoud Mostafa I Awad +2 位作者 Mahmoud Abdel Karim Sherif Khaled Mohamed Abdelmoneim 《World Journal of Orthopedics》 2023年第7期562-571,共10页
BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using e... BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures. 展开更多
关键词 Internal fixator External fixator UNSTABLE ANTERIOR PELVIC INJURIES
下载PDF
改良Masquelet技术联合Ilizarov Mini-Fixator治疗掌指骨大段骨缺损的临床疗效 被引量:2
2
作者 李发祥 方有生 +3 位作者 艾克拜尔·亚森 谭玉忠 崔留超 田林 《实用手外科杂志》 2023年第1期36-40,共5页
目的探讨改良Masquelet技术联合Ilizarov Mini-Fixator外固定治疗掌指骨大段骨缺损的可行性、临床应用及疗效分析。方法回顾性分析2019年11月-2021年10月符合手术适应证的掌指骨大段骨缺损17例患者的病历资料,均行改良Masquelet技术联合... 目的探讨改良Masquelet技术联合Ilizarov Mini-Fixator外固定治疗掌指骨大段骨缺损的可行性、临床应用及疗效分析。方法回顾性分析2019年11月-2021年10月符合手术适应证的掌指骨大段骨缺损17例患者的病历资料,均行改良Masquelet技术联合Ilizarov Mini-Fixator外固定治疗。⑴创伤性骨缺损:一期急诊行“地毯式”清创及相应修复手术,抗生素聚甲基丙烯酸甲酯(Polymethylmethacyrlate,PMMA)填充骨缺损,皮肤软组织缺损者同时给予骨水泥覆盖;二期:行带蒂皮瓣或植皮修复皮肤缺损创面,伤口愈合6~8周后去除骨水泥行自体骨移植联合Ilizarov Mini-Fixator外固定治疗;⑵感染性骨缺损:一期彻底清创、PMMA填充骨缺损,皮肤软组织缺损或皮肤软组织条件较差者给予彻底清创修复创面;二期方案同创伤性骨缺损。术后均给予预防或控制感染、观察患指(肢)及皮瓣血运等对症处理,均早期(2周)进行功能康复训练。结果17例术后随访5~29个月,移植骨均愈合,平均愈合时间11.9周(10.5~14.0周),术后均未出现伤口感染及皮瓣坏死等并发症。16例伤口均甲级愈合,1例延期愈合,移植骨愈合优良率为82.35%。根据随访结果,骨折愈合康复结束后手部功能评估:优5例,良8例,可4例,优良率为70.47%。均实现保指(肢)的目的,部分患者获得较好的手功能。结论应用改良Masquelet技术联合Ilizarov Mini-Fixator治疗掌指骨创伤性及感染性大段骨缺损的方法疗效可靠,具有操作简单、经济实用、损伤小,且移植骨愈合率高、愈合快、并发症及风险小等优点。可早期进行功能训练,有助于恢复手的外观及功能。 展开更多
关键词 改良 Masquelet技术 大段 掌指骨骨缺损 Ilizarov Mini-fixator
下载PDF
Increased dependence on nitrogen-fixation of a native legume in competition with an invasive plant 被引量:1
3
作者 Meixu Han Haiyang Zhang +12 位作者 Mingchao Liu Jinqi Tang Xiaocheng Guo Weizheng Ren Yong Zhao Qingpei Yang Binglin Guo Qinwen Han Yulong Feng Zhipei Feng Honghui Wu Xitian Yang Deliang Kong 《Plant Diversity》 SCIE CAS CSCD 2024年第4期510-518,共9页
Suppression of roots and/or their symbiotic microorganisms,such as mycorrhizal fungi and rhizobia,is an effective way for alien plants to outcompete native plants.However,little is known about how invasive and native ... Suppression of roots and/or their symbiotic microorganisms,such as mycorrhizal fungi and rhizobia,is an effective way for alien plants to outcompete native plants.However,little is known about how invasive and native plants interact with the quantity and activity of nutrient-acquisition agents.Here a pot experiment was conducted with monoculture and mixed plantings of an invasive plant,Xanthium strumarium,and a common native legume,Glycine max.We measured traits related to root and nodule quantity and activity and mycorrhizal colonization.Compared to the monoculture,fine root quantity(biomass,surface area)and activity(root nitrogen(N)concentration,acid phosphatase activity)of G.max decreased in mixed plantings;nodule quantity(biomass)decreased by 45%,while nodule activity in Nfixing via rhizobium increased by 106%;mycorrhizal colonization was unaffected.Contribution of N fixation to leaf N content in G.max increased in the mixed plantings,and this increase was attributed to a decrease in the rhizosphere soil N of G.max in the mixed plantings.Increased root quantity and activity,along with a higher mycorrhizal association was observed in X.strumarium in the mixed compared to monoculture.Together,the invasive plant did not directly scavenge N from nodule-fixed N,but rather depleted the rhizosphere soil N of the legume,thereby stimulating the activity of N-fixation and increasing the dependence of the native legume on this N source.The quantity-activity framework holds promise for future studies on how native legumes respond to alien plant invasions. 展开更多
关键词 Mycorrhizal strategy Nitrogen depletion Plant invasion Root nutrient acquisition strategy Symbiotic nitrogen fixation
下载PDF
Application of lesser trochanteric reduction fixator in the treatment of unstable intertrochanteric fractures
4
作者 Yao-Min Hui Guang Zeng +1 位作者 Pei-Yi Liu Bin Chai 《World Journal of Clinical Cases》 SCIE 2023年第25期5863-5869,共7页
BACKGROUND Closed reduction and internal fixation with intramedullary nails has been widely accepted for treating intertrochanteric fractures.AIM To focus on how to avoid displacement of the lesser trochanter in unsta... BACKGROUND Closed reduction and internal fixation with intramedullary nails has been widely accepted for treating intertrochanteric fractures.AIM To focus on how to avoid displacement of the lesser trochanter in unstable intertrochanteric fractures.METHODS We developed a lesser trochanteric reduction fixator for treating intertrochanteric fractures through fixing the lesser trochanter by combining the loop plate through the fixator after reduction by the reducer.Five patients with intertrochanteric fractures treated with the newly developed lesser trochanteric reduction fixator and loop plate combined with intramedullary nails,and 20 patients with intertrochanteric fractures treated with simple intramedullary nails were selected from December 2020 to March 2021.RESULTS The postoperative Harris hip score was significantly higher in patients treated with the lesser trochanteric reduction fixator than in patients treated without the lesser trochanteric reduction fixator,which indicated that this lesser trochanteric reduction fixator had a positive impact on rehabilitation of the hip joint after surgery and could significantly improve the quality of life of patients.CONCLUSION We fully realize the significance of trochanteric reduction and fixation,namely,reconstruction of structures under pressure,in the treatment of intertrochanteric fractures.As long as the general condition of patients is favorable and they are willing to undergo surgery,fixation of the main fracture end should be performed and the lesser trochanter should be reduced and fixed at the same time. 展开更多
关键词 Lesser trochanteric Intertrochanteric fractures Reduction fixator Loop plate Unstable fractures
下载PDF
Sustainable nitrogen fixation by bubble discharge plasma:Performance optimization and mechanism
5
作者 Yuankun Ye Xiaoyang Wei +2 位作者 Li Zhang Sen Wang Zhi Fang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第11期692-701,共10页
Sustainable nitrogen fixation driven by renewable energy sources under mild conditions has been widely sought to replace the industrial Haber-Bosch process.The fixation of nitrogen in the form of NO_(x)^(-)and NH_4^(+... Sustainable nitrogen fixation driven by renewable energy sources under mild conditions has been widely sought to replace the industrial Haber-Bosch process.The fixation of nitrogen in the form of NO_(x)^(-)and NH_4^(+)into aqueous solutions using electricity-driven gas-liquid discharge plasma is considered a promising prescription.In this paper,a scalable bubble discharge excited by nanosecond pulse power is employed for nitrogen fixation in the liquid phase.The nitrogen fixation performance and the mechanisms are analyzed by varying the power supply parameters,working gas flow rate and composition.The results show that an increase in voltage and frequency can result in an enhanced NO_(3)^(-)yield.Increases in the gas flow rate can result in inadequate activation of the working gas,which together with more inefficient mass transfer efficiencies can reduce the yield.The addition of O_(2) effectively elevates NO_(3)^(-)production while simultaneously inhibiting NH_4^(+) production.The addition of H_(2)O vapor increases the production of OH and H,thereby promoting the generation of reactive nitrogen and enhancing the yield of nitrogen fixation.However,the excessive addition of O_(2) and H_(2)O vapor results in negative effect on the yield of nitrogen fixation,due to the significant weakening of the discharge intensity.The optimal nitrogen fixation yield was up to 16.5 μmol/min,while the optimal energy consumption was approximately 21.3 MJ/mol in this study.Finally,the mechanism related to nitrogen fixation is discussed through the optical emission spectral(OES) information in conjunction with the simulation of energy loss paths in the plasma by BOLSIG+.The work advances knowledge of the effect of parameter variations on nitrogen fixation by gas-liquid discharge for higher yield and energy production. 展开更多
关键词 Nitrogen fixation Gas-liquid discharge plasma Bubble discharge MECHANISM
下载PDF
Intermittent sliding-lock-knot suture for limbal conjunctival autograft fixation in pterygium surgery:a technique note
6
作者 Ling Zhang Run-Hua Lyu +3 位作者 Jing-Ru Wang Wen-Jian Shi Feng Zheng Ying-Ying Gao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期838-844,共7页
AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive p... AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive patients with primary pterygium who had undergone pterygium excision combined with limbal conjunctival autograft transplantation between March 2021 and March 2022 at our institute were retrospectively analyzed.Primary outcome measures were mean duration of surgery and suture removal,degree of conjunctival hyperemia on postoperative day 1,pain score at suture removal,postoperative symptoms at 6mo,including conjunctival hyperemia,foreign body sensation,and graft stability.RESULTS:Ninety-eight patients underwent monocular surgery and were divided into ISLK(51 eyes)and RI(47 eyes)groups according to the type of conjunctiva autograft fixation method planned.There was no significant difference in mean duration of surgery between the two groups(18.59±2.39min vs 18.15±2.20min,P=0.417);however,compared to the RI group,shorter suture removal times were observed in the ISLK group[0.58min(0.42-0.87)vs 3.00min(2.21-4.15),P<0.001].The degree of conjunctival hyperemia on postoperative day 1 was milder in the ISLK group(P<0.001).Pain scores at suture removal were lower in the ISLK group than in RI group[1(0-3)vs 2(1-4),P<0.001].Postoperative symptoms at 6mo were comparable between the groups(P=0.487),with no recurrence.CONCLUSION:ISLK is an innovative method for limbal conjunctival autograft fixation after pterygium excision.Compared to RI fixation,ISLK facilitates suture removal and reduces discomfort,with comparable surgery duration and less conjunctival hyperemia. 展开更多
关键词 intermittent sliding-lock-knot fixation pterygium suture removal
下载PDF
Plasma nitrogen fixation system with dual-loop enhancement for improved energy efficiency and its efficacy for lettuce cultivation
7
作者 韩泽阳 张梦雪 +8 位作者 张頔 何欣 井天军 葛知轩 李玉鸽 朱童 任云鸿 仲崇山 季方 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第1期82-92,共11页
Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this ... Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this work,we present the development of a compact and automatic PNF system for on-site agricultural applications.The system utilized a gliding-arc discharge as the plasma source and employed a dual-loop design to generate NO_(x)from air and water under atmospheric conditions.Experimental results showed that the system with a dualloop design performs well in terms of energy costs and production rates.Optimal operational parameters for the system were determined through experimentation,resulting in an energy cost of 13.9 MJ mol^(-1)and an energy efficiency of 16 g kWh^(-1)for NO_(3)^(-)production,respectively.Moreover,the concentration of exhausted NO_(x)was below the emission standards.Soilless lettuce cultivation experiments demonstrated that NO_(x)^(-)produced by the PNF system could serve as liquid nitrate nitrogen fertilizer.Overall,our work demonstrates the potential of the developed PNF system for on-site application in the production of green-leaf vegetables. 展开更多
关键词 plasma nitrogen fixation gliding arc soilless cultivation LETTUCE
下载PDF
Microfluidic-oriented synthesis of enriched iridium nanodots/carbon architecture for robust electrocatalytic nitrogen fixation
8
作者 Hengyuan Liu Xingjiang Wu +2 位作者 Yuhao Geng Xin Li Jianhong Xu 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第3期544-555,共12页
Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-... Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-products.However,the chemical inertness of nitrogen and poor activated capacity on catalyst surface usually produce low ammonia yield and faradic efficiency.Herein,the microfluidic technology is proposed to efficiently fabricate enriched iridium nanodots/carbon architecture.Owing to in-situ co-precipitation reaction and microfluidic manipulation,the iridium nanodots/carbon nanomaterials possess small average size,uniform dispersion,high conductivity and abundant active sites,producing good proton activation and rapid electrons transmission and moderate adsorption/desorption capacity.As a result,the as-prepared iridium nanodots/carbon nanomaterials realize large ammonia yield of 28.73 μg h^(-1) cm^(-2) and faradic efficiency of 9.14%in KOH solution.Moreover,the high ammonia yield of 11.21 μg h^(-1) cm^(-2) and faradic efficiency of 24.30%are also achieved in H_(2)SO_(4) solution.The microfluidic method provides a reference for large-scale fabrication of nano-sized catalyst materials,which may accelerate the progress of electrocatalytic NRR in industrialization field. 展开更多
关键词 Iridium nanodots CARBON Microfluidic technology Efficient synthesis Electrocatalytic nitrogen fixation
下载PDF
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
9
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
In vitro performance of a biodegradable zinc alloy adjustable-loop cortical suspension fixation for anterior cruciate ligament reconstruction
10
作者 Ting Wang Zhangzhi Shi +7 位作者 Hongyong Zhong Xiangmin Li Jinling Sun Wei Yin Xiaojing Ji Qiang Wang Anqi Zhao Luning Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期887-898,共12页
Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,part... Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,particularly those made from conventional steel or titanium alloys.In this study,a biodegradable Zn-0.45Mn-0.2Mg(ZMM42)alloy with the yield strength of 300.4 MPa and tensile strength of 329.8 MPa was prepared through hot extrusion.The use of zinc alloys in the preparation of cortical suspension fixation buttons was proposed for the first time.After 35 d of immersion in simulated body fluids,the ZMM42 alloy fixation buttons were degraded at a rate of 44μm/a,and the fixation strength was retained(379.55 N)in the traction loops.Simultaneously,the ZMM42 alloy fixation buttons exhibited an increase in MC3T3-E1 cell viability and high antibacterial activity against Escherichia coli and Staphylococcus aureus.These results reveal the potential of biodegradable zinc alloys for use as ligament reconstruction materials and for developing diverse zinc alloy cortical suspension fixation devices. 展开更多
关键词 anterior cruciate ligament reconstruction zinc alloy fixation buttons mechanical property corrosion behavior BIOCOMPATIBILITY
下载PDF
Health economics for intra-capsular hip fractures undertaking fixation
11
作者 Anatole Wiik Thomas Ashdown Ian Holloway 《World Journal of Orthopedics》 2024年第1期30-38,共9页
BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM T... BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM To determine the most beneficial method of fixation for patients with intracapsular hip fractures.METHODS A registered audit from 2012-2018 was conducted on all intra-capsular hip fractures treated with 2 commonly used fixation methods.Patient notes,electronic records and clinical codes for cost benefit were evaluated.A validated quality of life measure was collected at least 1 year after surgery.RESULTS A total of 83 patients were identified with intra-capsular fractures undergoing fixation during the retrospective period.There were 47 cannulated cancellous screw and 36 sliding hip screw fixations with the case mix comparable for age,gender,co-morbidities and fracture configuration.There was no significant difference in blood loss,tip apex distance,radiation exposure,length of stay,radiological union time,collapse,avascular necrosis or re-operation between fixation methods.Logistic regression analysis demonstrated displaced intracapsular hip fractures correlated significantly with an undesirable outcome conferring a relative odds ratio of 7.25.There were 9(19%)and 4(11%)patients respectively,who required re-operation.There was no significant difference in health resource group tariff and implant cost with comparable EQ-5D and visual CONCLUSION No significant advantage was identified with differing fixation type,but irrespective there were a high number of patients requiring re-operation.This was predicted by initial fracture displacement and patient age.Arthroplasty may need to be carefully considered for health economics and patient benefit. 展开更多
关键词 Hip fracture fixatION Patient reported outcome measure COST
下载PDF
Arthroscopic M-shaped suture fixation for tibia avulsion fracture of posterior cruciate ligament:A modified technique and case series
12
作者 Xiao-Hui Zhang Jian Yu +3 位作者 Meng-Yao Zhao Jin-Hui Cao Bing Wu Dan-Feng Xu 《World Journal of Orthopedics》 2024年第7期642-649,共8页
BACKGROUND Tibial avulsion fractures of the posterior cruciate ligament(PCL)are challenging to treat and compromise knee stability and function.Traditional open surgery often requires extensive soft tissue dissection,... BACKGROUND Tibial avulsion fractures of the posterior cruciate ligament(PCL)are challenging to treat and compromise knee stability and function.Traditional open surgery often requires extensive soft tissue dissection,which may increase the risk of morbidity.In response to these concerns,arthroscopic techniques have been evolving.The aim of this study was to introduce a modified arthroscopic tech-nique utilizing an M-shaped suture fixation method for the treatment of tibial avulsion fractures of the PCL and to evaluate its outcomes through a case series.AIM To evaluate the effects of arthroscopic M-shaped suture fixation on treating tibia avulsion fractures of the PCL.METHODS We developed a modified arthroscopic M-shaped suture fixation technique for tibia avulsion fractures of the PCL.This case series included 18 patients who underwent the procedure between January 2021 and December 2022.The patients were assessed for range of motion(ROM),Lysholm score and International knee documentation committee(IKDC)score.Postoperative complications were also recorded.RESULTS The patients were followed for a mean of 13.83±2.33 months.All patients showed radiographic union.At the final follow-up,all patients had full ROM and a negative posterior drawer test.The mean Lysholm score significantly improved from 45.28±8.92 preoperatively to 91.83±4.18 at the final follow-up(P<0.001),and the mean IKDC score improved from 41.98±6.06 preoperatively to 90.89±5.32 at the final follow-up(P<0.001).CONCLUSION The modified arthroscopic M-shaped suture fixation technique is a reliable and effective treatment for tibia avulsion fractures of the PCL,with excellent fracture healing and functional recovery. 展开更多
关键词 Posterior cruciate ligament Avulsion fracture ARTHROSCOPIC Case series Suture fixation
下载PDF
A new abdominal drainage tube fixation method for 3-port laparoscopic cholecystectomy improves patients’postoperative quality of life
13
作者 Fenghua Zhang Lin Lin +2 位作者 Huan Zhang Jinghua Liu Rui Wang 《Laparoscopic, Endoscopic and Robotic Surgery》 2024年第3期107-112,共6页
Objective Laparoscopic surgery has become a routine general surgery with many advantages,such as alleviating abdominal pain.However,postoperative pain caused by abdominal drainage tubes has attracted little attention ... Objective Laparoscopic surgery has become a routine general surgery with many advantages,such as alleviating abdominal pain.However,postoperative pain caused by abdominal drainage tubes has attracted little attention from medical staff.The aim of this study was to explore the influence of a new abdominal drainage tube fixation method for 3-port laparoscopic cholecystectomy(LC)on patients’postoperative quality of life.Methods Patients who underwent 3-port LC with abdominal drainage tubes in the Department of Hepatobiliary Surgery of Linyi People’s Hospital from March 1,2023 to October 31,2023 due to gallstones with chronic cholecystitis were selected for this study.The patients were randomly divided into an experimental group and a control group.In the experimental group,the new abdominal drainage tube fixation method was used,while in the control group,the traditional method was used.Afterward,the quality of life of patient in terms of pain,activity,recovery time,and mental health status was evaluated.The exudate around the patient’s drainage tube was collected for bacterial culture and analysis.Results A total of 139 patients were randomly divided into an experimental group(70 patients)and a control group(69 patients).The patients’baseline characteristics were not significantly different.The patients in the experimental group had better outcomes in quality of life,with higher pain scores(24.03±2.37 vs.15.48±2.29,p<0.001)and activity scores(20.57±1.78 vs.14.13±1.43,p<0.001),and a shorter postoperative recovery time(2.36±0.68 d vs.2.96±1.34 d,p<0.001).The same results were shown in linear regression analysis scores of the 2 groups.The positive rate of bacterial culture in the exudate around the patient’s drainage tube in the experimental group was significantly lower than that in the control group(12.9%vs.43.5%,p<0.001);and furthermore,the positive rate of conditional pathogenic bacteria was even lower(7.1%vs.33.3%,p<0.001)in the experimental group than in the control group.Conclusion This new abdominal drainage tube fixation method can effectively promote patient rehabilitation and improve the quality of life for patient following 3-port LC with abdominal drainage tubes. 展开更多
关键词 Abdominal drainage tube Surgical site infection Quality of life fixation method Laparoscopic cholecystectomy
下载PDF
Assessment of Nitrogen Fixation, Uptake, and Leaching in Maize/Soybean Intercropping System at Varied Soil Depths and under Phosphorus Application in Chinese Agricultural Settings
14
作者 Bertha Magombo Chunjie Li Benjamin Kolie 《Natural Resources》 2024年第7期173-187,共15页
The study of Nitrogen fixation, uptake, and leaching at different soil depths in the co-cultivation of maize and soybean under phosphorus fertilization is important for sustainable agriculture. This study was conducte... The study of Nitrogen fixation, uptake, and leaching at different soil depths in the co-cultivation of maize and soybean under phosphorus fertilization is important for sustainable agriculture. This study was conducted in Quzhou, Hebei Province, China, with MC812 maize and Jidou12 soybean varieties. Soil samples were taken from each plot to create a composite sample. The results show that nitrogen concentration varies at different depths and is higher in all treatments between 40 and 100 cm. Incorporating intercropping of maize and soybeans into farming practices can lead to more sustainable and environmentally friendly agriculture in China. 展开更多
关键词 Nitrogen Maize/Soybean FERTILIZATION INTERCROPPING Soil fixatION
下载PDF
Lateral femoral tunnel preparation and graft fixation for anterior cruciate ligament reconstruction–A discussion
15
作者 Mehak Chandanani Andrea Volpin 《World Journal of Clinical Cases》 SCIE 2024年第17期3277-3280,共4页
This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft ... This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft fixation techniques.The paper explores and comments on a recently published review by Dai et al,titled"Research progress on preparation of lateral femoral tunnel and graft fixation in ACLR",while providing insight into its relevance within the field of ACLR,and recommendations for future research. 展开更多
关键词 Anterior cruciate ligament reconstruction Arthroscopic surgery Lateral femoral tunnel Graft fixation techniques Anterior cruciate ligament tear BIOMECHANICS Knee injuries
下载PDF
Percutaneous Fixation as an Option for Traumatic Neurologically Intact Thoracolumbar Vertebral Fractures
16
作者 Ahmed Hosameldin Ashraf Osman +1 位作者 Mahmoud Gomaa Mahmoud Ramadan 《Open Journal of Modern Neurosurgery》 2024年第4期246-255,共10页
Background: The most frequent spinal fracture is the thoracolumbar fracture. Minimally invasive percutaneous fixation of cases having thoracolumbar vertebral fractures without neurological impairments has remained con... Background: The most frequent spinal fracture is the thoracolumbar fracture. Minimally invasive percutaneous fixation of cases having thoracolumbar vertebral fractures without neurological impairments has remained controversial. The advantages of minimally invasive percutaneous fixation are decreasing muscle and soft tissue injury, decreasing blood loss and infection rate, in addition to shortening hospital stay and recovery times. In comparison to the open technique, percutaneous fixation is adequate for treating thoracolumbar (TL) fractures without causing neurological impairments & with satisfactory outcomes in terms of kyphosis decline. Elevated radiation exposure to the surgeon &the patient, lack of decompression and fusion via bone graft, & a steep learning curve are all disadvantages of percutaneous fixation of vertebral fractures. Methods: This study was retrospectively conducted on forty-eight patients, age ranging from 16 to 65 years old, with a thoracolumbar (TL) fracture without causing neurological impairments who were meeting the eligibility criteria for fixation in the period from July 2019 to January 2024. Results: We included the forty-eight patients who met the inclusion criteria (34 males and 14 females) their ages ranged from 16 to 65 years. The most common pathology was L1 fracture in 38 patients. No major complications were experienced, only wound infection in five patients which was treated efficiently with repeated dressings and broad-spectrum antibiotics. Four patients experienced misdirected screws, only in one patient the screw encroach into the spinal canal with no deficit experienced, while the other three showed minimally laterally deviated screws. Conclusion: The advantages of percutaneous pedicle screw fixation in thoracolumbar fractures through preservation of posterior musculature, are less blood loss, shorter operative time, lower infection risk, less post-operative pain, shorter rehabilitation time as well as a shorter hospital stay. Limitations of percutaneous fixation include the inability to achieve direct spinal canal decompression and, not having the option to perform a fusion and also requiring a learning curve to master the anatomy and technique. 展开更多
关键词 Thoracolumbar Fractures Fracture Stability Percutaneous fixation
下载PDF
Clinical Outcome of Internal Fixation and Fusion in the Treatment of Spinal Fractures by Paraspinal Muscular Space Approach
17
作者 Yafei Zhao Qiushuang Ma +3 位作者 Meng Zhang Shengwang Li Yannan Li Chenguang Tian 《Journal of Clinical and Nursing Research》 2024年第7期10-15,共6页
Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Ho... Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Hospital of TCM from October 2022 to April 2024 were selected as the study subjects and were randomly divided into the control group(n=52)and the observation group(n=52)according to the random number table method.The control group was treated with the conventional approach of internal fixation surgery,and the observation group was treated with the paraspinal muscular interspace approach of internal fixation fusion.The two groups’general data,surgical indexes,pain,lumbar spine function,and postoperative complications were observed.Results:The baseline data of the two groups of patients were not statistically significant(all P>0.05)while the intraoperative bleeding,the first postoperative time getting up from bed,and the length of hospital stay of the patients in the observation group were shorter than that of the control group(all P=0.000<0.001),and the duration of the operation was longer than that of the control group(t=2.644,P=0.010<0.05);at 3 months postoperatively,the VAS scores of the patients in the observation group were significantly lower than those in the control group(t=10.768,P=0.000<0.001),and the JOA score was higher than that of the control group(t=6.498,P=0.000<0.001);the total complication rate of patients in the observation group(3/5.77%)was significantly lower than that of the control group(12/23.08%)(χ^(2)=6.310,P=0.012<0.05).Conclusion:In the treatment of spinal fracture patients,compared with the conventional approach to internal fixation surgery,the paraspinal muscular gap approach to internal fixation and fusion treatment is less traumatic,postoperative lumbar spine function recovery is faster,and can reduce the incidence of postoperative complications. 展开更多
关键词 Paraspinal muscular interspace approach fixation and fusion Spinal fracture
下载PDF
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
18
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
Kinematics of the Ortho-SUV Frame Using as a Novel External Fixator for Orthopedic Surgery 被引量:2
19
作者 FU Chao FAN Jiacheng +1 位作者 WANG Shigang LIANG Qinghua 《Journal of Donghua University(English Edition)》 EI CAS 2019年第4期325-331,共7页
The Ortho-SUV frame,a novel external fixator,can effectively treat limb deformities and fractures.Its kinematics is used when it is necessary to achieve bone movements with high precision.In this work,the kinematics m... The Ortho-SUV frame,a novel external fixator,can effectively treat limb deformities and fractures.Its kinematics is used when it is necessary to achieve bone movements with high precision.In this work,the kinematics model of the Ortho-SUV frame is established by six pose parameters,and its forward and inverse solutions are given.There is no need to solve nonlinear high-coupling equations with trigonometric functions in this solution method due to its special structure.By numerical examples and simulated orthopedic experiment of tibial fracture,the correctness and accuracy of the kinematics model and its solutions are verified.Besides,on the basis of kinematics analysis,the position workspace and orientation workspace of the Ortho-SUV frame are simulated in Matlab,which can help surgeons choose suitable device dimensions.The kinematics analysis provides a theoretical basis for the Ortho-SUV frame to be used in orthopedic treatment. 展开更多
关键词 Ortho-SUV FRAME KINEMATICS parallel mechanism external fixator WORKSPACE
下载PDF
Management of Tibial Metaphyseal Fractures by Hybrid External Fixator 被引量:2
20
作者 S. K. Venkatesh Gupta Gottipati Sunil 《Open Journal of Orthopedics》 2014年第3期84-89,共6页
Introduction: The Hybrid External Fixator combines the advantages of the monolateral pin fixators and the circular Ilizarov wire fixators. Principle of early motion has been touted as the functional savior of major in... Introduction: The Hybrid External Fixator combines the advantages of the monolateral pin fixators and the circular Ilizarov wire fixators. Principle of early motion has been touted as the functional savior of major intra articular injuries in application of hybrid external fixation. Materials & Methodology: 48 patients were considered for the study with tibial fractures admitted in Mamata General Hospital from May 2011 to May 2013. Results: The union and functional outcome of hybrid external fixator in simple and complex proximal and distal metaphyseal fractures of tibia in adults was evaluated at our centre. The fractures of the proximal tibia united with an average of 13.3 weeks (12 - 16 weeks). The fractures of the distal tibia united with an average of 14.42 weeks (13 - 22 weeks) with minimal complications. Conclusion: Our study shows high satisfaction rate after fixation, provides adequate stability and allows early motion of the joint. It is also effective in extra articular fractures occurring within 5 cm of the joint as the IM nails often do not provide enough stability and plating requires extensive soft tissue dissection. 展开更多
关键词 HYBRID EXTERNAL fixator TIBIAL Metapyseal FRACTURES