A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The si...A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The simultaneous determination of the multi-elements wasperformed with ICP-MS.A solid reduction system involving the use of potassiumtetraborohydride and tartaric acid was applied to generating metal hydride or cold vaporefficiently.The factors affecting the metal cold vapor generation were studied.The mainadvantage of the technique is that only a 4μL volume of sample was required for the cold vapor展开更多
Element zirconium reacted with polytetrafluoroethylene (PTFE) dispersed in isopropanol-water mixture to form volatile fluoride when heated in an electrothermal graphite furnace, and the fluorides formed subsequently w...Element zirconium reacted with polytetrafluoroethylene (PTFE) dispersed in isopropanol-water mixture to form volatile fluoride when heated in an electrothermal graphite furnace, and the fluorides formed subsequently were vaporized into ICP for atomization and excitation. The technique provides a picogram detectkm limit and adequate precision of 4% relative standard deviation. Linear dynamic range covers over three orders of magnitude. The process of sample preparation it very convenient. It is expected that the method proposed is suitable for determination of other refractory elements.展开更多
A system is described in which a graphite furnace electrothermal vaporization device is employed for the introduction of microlitre liquid sample into an inductively coupled argon plasma. The technique provides a pico...A system is described in which a graphite furnace electrothermal vaporization device is employed for the introduction of microlitre liquid sample into an inductively coupled argon plasma. The technique provides a picogram detection limit and an adequate precision with a relative standard deviation of 4%. Mechanism of analyte condensation in transport process is explored. As an application, the technique combined with DDTC/CCl4 extraction is used to enrich and determine non- rare earth impurities in highly pure La2O3.展开更多
Atmospheric pressure plasmas are not only powerful sources for excitation but also very good atomizers. In the early developing stage, the inductively coupled plasma (ICP) was investigated as an atomizer for atomic ab...Atmospheric pressure plasmas are not only powerful sources for excitation but also very good atomizers. In the early developing stage, the inductively coupled plasma (ICP) was investigated as an atomizer for atomic absorption spectrometry (AAS). A multiple pass system,a T-shaped plasma cell,and a long-path torch was used to increase the absorption path length. But all these ICP-AAS systems gave low sensitivities for most展开更多
In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in det...In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.展开更多
A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels i...A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels in water. A 100 mL water sample was adjusted to pH 5.6 with nitric acid and a 1 mol?L–1 ammonium acetate solution, and then passed through an IED (diameter, 47 mm;effective filtering diameter, 35 mm) at a flow rate of 80 - 100 mL?min–1 to preconcentrate seven analytes. The IED was dried at 100?C for 20 min in an electric oven, and 110 - 145 small disks, each 2 mm in diameter, were punched out from the IED. A small disk was introduced into the graphite furnace and atomized according to a heating program. For Cd, Sn, Pb, and Bi measurements, Pd was used as a chemical modifier to enhance the absorbances. Calibration was performed using aqueous standard solutions. The detection limits, corresponding to three times the standard deviation (n = 5) of the blank values, were 0.092 μg·L–1 for Co, 0.12 μg·L–1 for Ni, 0.40 μg·L–1 for Cu, 0.077 μg·L–1 for Cd, 0.92 μg·L–1 for Sn, 0.61 μg·L–1 for Pb, and 0.80 μg·L–1 for Bi with an enrichment factor of 140 using a 100-mL water sample. A spike test for the seven analytes in tap water, rainwater, river water, and mineral drinking water showed quantitative recoveries (93% - 108%).展开更多
文摘A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The simultaneous determination of the multi-elements wasperformed with ICP-MS.A solid reduction system involving the use of potassiumtetraborohydride and tartaric acid was applied to generating metal hydride or cold vaporefficiently.The factors affecting the metal cold vapor generation were studied.The mainadvantage of the technique is that only a 4μL volume of sample was required for the cold vapor
基金Present address: Centre of Material Research and Testing. Wuhan Univeraity of Technology, Wuhan
文摘Element zirconium reacted with polytetrafluoroethylene (PTFE) dispersed in isopropanol-water mixture to form volatile fluoride when heated in an electrothermal graphite furnace, and the fluorides formed subsequently were vaporized into ICP for atomization and excitation. The technique provides a picogram detectkm limit and adequate precision of 4% relative standard deviation. Linear dynamic range covers over three orders of magnitude. The process of sample preparation it very convenient. It is expected that the method proposed is suitable for determination of other refractory elements.
文摘A system is described in which a graphite furnace electrothermal vaporization device is employed for the introduction of microlitre liquid sample into an inductively coupled argon plasma. The technique provides a picogram detection limit and an adequate precision with a relative standard deviation of 4%. Mechanism of analyte condensation in transport process is explored. As an application, the technique combined with DDTC/CCl4 extraction is used to enrich and determine non- rare earth impurities in highly pure La2O3.
文摘Atmospheric pressure plasmas are not only powerful sources for excitation but also very good atomizers. In the early developing stage, the inductively coupled plasma (ICP) was investigated as an atomizer for atomic absorption spectrometry (AAS). A multiple pass system,a T-shaped plasma cell,and a long-path torch was used to increase the absorption path length. But all these ICP-AAS systems gave low sensitivities for most
文摘In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.
文摘A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels in water. A 100 mL water sample was adjusted to pH 5.6 with nitric acid and a 1 mol?L–1 ammonium acetate solution, and then passed through an IED (diameter, 47 mm;effective filtering diameter, 35 mm) at a flow rate of 80 - 100 mL?min–1 to preconcentrate seven analytes. The IED was dried at 100?C for 20 min in an electric oven, and 110 - 145 small disks, each 2 mm in diameter, were punched out from the IED. A small disk was introduced into the graphite furnace and atomized according to a heating program. For Cd, Sn, Pb, and Bi measurements, Pd was used as a chemical modifier to enhance the absorbances. Calibration was performed using aqueous standard solutions. The detection limits, corresponding to three times the standard deviation (n = 5) of the blank values, were 0.092 μg·L–1 for Co, 0.12 μg·L–1 for Ni, 0.40 μg·L–1 for Cu, 0.077 μg·L–1 for Cd, 0.92 μg·L–1 for Sn, 0.61 μg·L–1 for Pb, and 0.80 μg·L–1 for Bi with an enrichment factor of 140 using a 100-mL water sample. A spike test for the seven analytes in tap water, rainwater, river water, and mineral drinking water showed quantitative recoveries (93% - 108%).