期刊文献+
共找到2,814篇文章
< 1 2 141 >
每页显示 20 50 100
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
1
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang Lingbao Wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Based on the water source heat pump system operation control and energy consumption optimization
2
作者 Guangxiang Wang Wei Ding 《Journal of World Architecture》 2020年第3期5-8,共4页
The contradiction between the increasing material demand and resource,is the country has faced problems,to better solve the material demand and the contradiction between the environment and resources,is applied to the... The contradiction between the increasing material demand and resource,is the country has faced problems,to better solve the material demand and the contradiction between the environment and resources,is applied to the development of new energy,new energy,not only can alleviate people and resources,environment and resources,the contradiction between people and the environment,also can promote the sustainable development of world economy,HVAC technology has emerged a new generation of energysaving technology,HVAC has the characteristics of low consumption,low pollution,is a development of technology,to be promoted for environmentfriendly,resource-conserving society has an important role in promoting.This paper focuses on the HVAC technology,water source heat pump system operation control and energy consumption optimization,for the relevant personnel reference. 展开更多
关键词 heat pump system Operation control Optimization of energy consumption
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
3
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 天津 气源热泵系统 供暖 运行性能 除霜
下载PDF
The Efficiency Analysis of the Exhaust Air Heat Pump System 被引量:1
4
作者 Alo Mikola Teet-Andrus Koiv 《Engineering(科研)》 2014年第13期1037-1045,共9页
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h... This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5. 展开更多
关键词 heat pump Exhaust Air heat pump heat Recovery heat Requirement COP The Coefficient of Performance
下载PDF
An Analytical Model for the Thermal Assessment of a Vertical Double U-Tube Ground-Coupled Heat Pump System in Steady-State Conditions
5
作者 Ali H.Tarrad 《Fluid Dynamics & Materials Processing》 EI 2022年第4期1111-1127,共17页
An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat trans... An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat transfer throughout the backfill medium due to the presence of the second loop.The verification of the model was achieved by the implementation of five different borehole configurations and a comparison with other correlations in the available literature.The model considered a U-tube spacing range between(2)and(4)times the U-tube outside diameter producing a geometry configuration factor range of(0.29-0.6).The results of the model were utilized for the assessment of the DX ground heat exchanger coupled heat pump system.For similar geometrical configurations,the borehole thermal resistance experienced a decrease as the geometry factor increased.The single U-tube borehole thermal resistance was higher than that of the double U-tube heat exchanger by(10-27)%for the examined geometry configurations.The borehole thermal resistance at tube spacing of twice the tube diameter was higher than the predicted value at the triple diameter and fell in the range of(18-34)%. 展开更多
关键词 Ground-coupled heat pumps borehole thermal resistance double U-tube modeling
下载PDF
Experimental Analyses of Moderately High-Temperature Heat Pump Systems with R245fa and R1233zd(E)
6
作者 Ting Chen Oh Kyung Kwon 《Energy Engineering》 EI 2022年第6期2231-2242,共12页
With the limited production and use of R245fa,environmentally friendly refrigerant has attracted the attention of researchers.Due to the similar thermal characteristics,R1233zd(E)is considered to be an ideal substitut... With the limited production and use of R245fa,environmentally friendly refrigerant has attracted the attention of researchers.Due to the similar thermal characteristics,R1233zd(E)is considered to be an ideal substitute for R245fa in heat pump systems.In this study,the performance and economic analysis of heat pump systems with R245fa and R1233zd(E)as refrigerants are carried out.The results show that the total cost of R1233zd(E)system is more than 10%higher than that of R245fa system under the same heating load.With the increase of condensation temperature,the heating capacity of both systems decreases,and with the increase of evaporation temperature,the heating capacity increases.The variation trend of coefficient of performance(COP)of the two systems is similar to that of heating capacity.Under the same operating conditions,the COP of R1233zd(E)system is 19.2%higher than that of R245fa system,and the volumetric heat capacity of R1233zd(E)is 9.0%–13.9%lower than that of R245fa.The economic analysis results show that the investment cost of R1233zd(E)system is low under the same heat load. 展开更多
关键词 heat pump R1233zd(E) R245FA performance comparison economic analysis
下载PDF
Scanning PIV Method and Its Application to the Calorimetry of Ground Source Heat Pump Systems
7
作者 Shumpei Funatani Shinya Amano +1 位作者 Tetsuaki Takeda Koji Toriyama 《Journal of Flow Control, Measurement & Visualization》 2018年第1期48-55,共8页
Ground source heat pump (GSHP) systems that use a direct expansion method?are expected to have higher energy-saving performance than conventional air conditioning systems. The heat transfer rate is evaluated by measur... Ground source heat pump (GSHP) systems that use a direct expansion method?are expected to have higher energy-saving performance than conventional air conditioning systems. The heat transfer rate is evaluated by measuring the temperature, humidity, and flow rate at the indoor unit of the GSHP system. However, it is difficult to evaluate the flow rate by measuring the flow velocity distribution at the outlet of the indoor unit. In this study, the Scanning PIV method is proposed to improve the accuracy of the flow rate measured by hot wire anemometers. The flow rates obtained by the hot wire anemometers were 60.6% and 15.2% higher than those from the PIV method during cooling and heating operation, respectively. Compensation formulas are generated using the results of the Scanning PIV method to correct the measurements from the hot wire anemometers. This compensation formula reduced the error generated by the nonuniformity of velocity distribution. It was 60.6% to 2.5% in cooling operation and 15.2% to 0.9% in heating operation, respectively. The compensation formulas were applied to evaluate the performance of a GSHP system, and the result shows that the GSHP system provides improved performance stability compared to traditional air conditioning systems. 展开更多
关键词 SCANNING PIV CALORIMETRY GEOTHERMAL heat pump system
下载PDF
Efficiency of Combined Solar Thermal Heat Pump Systems
8
作者 Werner Lerch AndreasHeinz Richard Heimrath Christoph Hochenauer 《Journal of Civil Engineering and Architecture》 2015年第6期734-740,共7页
关键词 热泵系统 太阳能 空气热交换器 光热 动态仿真系统 生活热水 P系统 集电极
下载PDF
Case Studies of Energy Saving and CO<sub>2</sub>Reduction by Cogeneration and Heat Pump Systems
9
作者 Satoru Okamoto 《Open Journal of Energy Efficiency》 2013年第2期107-120,共14页
This paper describes two case studies: 1) a cogeneration system of a hospital and 2) a heat pump system installed in an aquarium that uses seawater for latent heat storage. The cogeneration system is an autonomous sys... This paper describes two case studies: 1) a cogeneration system of a hospital and 2) a heat pump system installed in an aquarium that uses seawater for latent heat storage. The cogeneration system is an autonomous system that combines the generation of electrical, heating, and cooling energies in a hospital. Cogeneration systems can provide simultaneous heating and cooling. No technical obstacles were identified for implementing the cogeneration system. The average ratio between electric and thermal loads in the hospital was suitable for the cogeneration system operation. An analysis performed for a non-optimized cogeneration system predicted large potential for energy savings and CO2 reduction. The heat pump system using a low-temperature unutilized heat source is introduced on a heat source load responsive heat pump system, which combines a load variation responsive heat pump utilizing seawater with a latent heat-storage system (ice and water slurry), using nighttime electric power to level the electric power load. The experimental coefficient of performance (COP) of the proposed heat exchanger from the heat pump system, assisted by using seawater as latent heat storage for cooling, is discussed in detail. 展开更多
关键词 COGENERATION system heat pump system Energy Saving CO2 REDUCTION Hospital AQUARIUM
下载PDF
Possibilities of Reducing Energy Consumption by Optimization of Ground Source Heat Pump Systems in Babylon, Iraq
10
作者 Jenny Lindblom Nadhir Al-Ansari Qais Al-Madhlom 《Engineering(科研)》 2016年第3期130-139,共10页
Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with ti... Iraq is located in the Middle East with an area that reaches 437,072 km2 and a population of about 36 million. This country is suffering from severe electricity shortage problems which are expected to increase with time. In this research, an attempt is made to minimize this problem by combining the borehole thermal energy storage (BTES) with a heat pump, the indoor temperature of a residential building or other facility may be increased or reduced beyond the temperature interval of the heat carrier fluid. Due to the relatively high ground temperature in Middle Eastern countries, the seasonal thermal energy storages (STES) and ground source heat pump (GSHP) systems have a remarkable potential, partly because the reduced thermal losses from the underground storage and the expected high COP (ratio of thermal energy gain to required driving energy (electricity)) of a heat pump, partly because of the potential for using STES directly for heating and cooling. In this research, groundwater conditions of Babylon city in Iraq were investigated to evaluate the possibility of using GSHP to reduce energy consumption. It is believed that such system will reduce consumed energy by about 60%. 展开更多
关键词 Ground Source heat pump Seasonal Thermal Energy Storages Energy Saving BABYLON Iraq
下载PDF
Zoning operation of energy piles to alleviate the soil thermal imbalance of ground source heat pump systems 被引量:2
11
作者 Tian You Weitao Zeng 《Energy and Built Environment》 2023年第1期57-63,共7页
Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-fe... Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-ference between the heating and cooling loads,the system will suffer from a soil thermal imbalance which may further decline the system performance and even cause a system failure.A hybrid ground source heat pump sys-tem that integrates auxiliary equipment can solve the problem,however,it needs additional investment and a complicated control strategy.In this paper,the zoning operation of energy piles can effectively improve the tem-perature recovery ability of soil in the energy pile group and thus alleviate the soil thermal imbalance.Specifically,a heating-dominated residential building in Beijing is selected for a case study,with 144 energy piles arranged in a 12×12 layout.An analytical model of the spiral-coil energy pile group with seepage will be adopted,which can consider the groundwater flow,the geometry of spiral coils,and the thermal interaction among different energy piles,achieving high calculation accuracy and fast calculation speed.Based on this analytical energy pile model,a system model will be built to investigate the system performance influenced by different zoning operation strategies.Results show that intensive heat injection into the center of the pile group(Strategy 2 and Strategy 3)or heat extraction from the outer layer of the pile group(Strategy 4)can relieve the cold accumulation.Strategy 2 can relieve the outlet temperature decline from 5.54℃ to 4.46℃ and improve the heating COP from 3.297 to 3.423 compared to the conventional full operation strategy.Although the annual heat pump COP of Strategy 2 is a little lower than that of conventional full operation strategy,Strategy 2 has the shortest unmet heating or cooling time.Therefore,the proposed zoning operation strategy can achieve good system efficiency and excellent system reliability compared to the conventional strategy. 展开更多
关键词 Ground source heat pump Energy pile Zoning operation Soil thermal imbalance Cold accumulation
原文传递
Optimized design and integration of energy storage in Solar-Assisted Ground-Source Heat Pump systems
12
作者 Maria Ferrara Enrico Fabrizio 《Building Simulation》 SCIE EI CSCD 2023年第10期1933-1948,共16页
The integrated use of multiple renewable energy sources to increase the efficiency of heat pump systems,such as in Solar Assisted Geothermal Heat Pumps(SAGHP),may lead to significant benefits in terms of increased eff... The integrated use of multiple renewable energy sources to increase the efficiency of heat pump systems,such as in Solar Assisted Geothermal Heat Pumps(SAGHP),may lead to significant benefits in terms of increased efficiency and overall system performance especially in extreme climate contexts,but requires careful integrated optimization of the different system components.In particular,thermal storages take a fundamental role in optimizing the integration of renewable energy sources and the system operation.This work investigates the potential design optimization of a SAGHP system in a mountain site by exploring many different alternatives to optimize the mutual relationship between the solar field,the geothermal field and the water thermal storages.This is done through an original simulation-based multi-objective optimization framework considering energy efficiency and economic feasibility,which allows appraising the impact of the different design alternatives on the overall system performance and on the dynamics of the different system components.Results identify a set of optimized system configurations that optimize the integrated exploitation of the different thermal sources showing a potential increase of the overall system performance leading to 34%lower global cost compared to the initial design.High robustness of the optimal design solutions is reported with respect to the current context of high economic uncertainty. 展开更多
关键词 thermal storage geothermal energy heat pumps building simulation artificial intelligence cost optimization energy flexibility
原文传递
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
13
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
14
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Photovoltaic-thermal solar-assisted heat pump systems for building applications:Integration and design methods
15
作者 Alessandro Miglioli NiccolòAste +1 位作者 Claudio Del Pero Fabrizio Leonforte 《Energy and Built Environment》 2023年第1期39-56,共18页
The photovoltaic-thermal collector is one of the most interesting technology for solar energy conversion,com-bining electric and thermal energy production in a single device.Vapour-compression heat pump is already con... The photovoltaic-thermal collector is one of the most interesting technology for solar energy conversion,com-bining electric and thermal energy production in a single device.Vapour-compression heat pump is already considered the most suitable clean technology for buildings thermal energy needs.The combination of these two technologies in an integrated“photovoltaic-thermal solar-assisted heat pump”(PVT-SAHP)system allows reaching a high fraction of the building thermal needs covered by renewable energy sources and to improve the performances of both the photovoltaic-thermal collector and the heat pump.The first is cooled down increasing its energy conversion efficiency,while providing low-temperature thermal energy to the second,which benefits from a higher evaporation temperature.The review study presents the state-of-art of photovoltaic-thermal solar-assisted heat pump systems intended to cover thermal energy needs in buildings,with a particular focus on the integration methodologies,the possible configurations,the use of different sources and the design of sub-system components.These issues are addressed by much scientific research,to improve the reliability and applicability of this technology,as an option for the building decarbonization.This study aims to present PVT-SAHP systems in an organic and critical way to propose a useful tool for future research developments.More in detail,the work highlights the fact that the integration of photovoltaic-thermal collectors as evaporator of the heat pump in direct-expansion systems allows the highest heat recovery and performances.However,the distinction of the two circuits lead to more reliable,flexible and robust systems,especially when combined with a second heat source,being able to cover both heating and cooling needs.The implementation of real-time control strategy,as well as the continuous development of the compressor and refrigerant industries is positively influencing this technology,which is receiving more and more attention from scientific research as a suitable solution for nearly zero energy buildings. 展开更多
关键词 Solar-assisted heat pump Photovoltaic-thermal collector PVT-SAHP Renewable energy HVAC Technology review
原文传递
Experiment Investigation and Control Strategies on Two-Phase Refrigerant Injection Heat Pump System for Electric Vehicle in Start-up Stage 被引量:1
16
作者 QIN Fei LIU Hanzhou +2 位作者 ZOU Huiming CHEN Deqi TIAN Changqing 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第3期828-839,共12页
Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with r... Due to the poor heating performance and operating safety in low ambient temperature,traditional Air Source Heat Pump(ASHP)for Electric Vehicles(EVs)has many limits in cold region,which can be solved by the ASHP with refrigerant injection.During the start-up stage of EV in winter,the inlet air temperature of the in-car condenser is the same as the ambient temperature.At this situation,the performance and control strategy of the heat pump require special attention.In the present study,a series of experiments were carried out on the heating performance of the Refrigerant Injection Heat Pump(RIHP)system in start-up stage of EV,at the ambient temperature from–20℃ to–5℃.The effects of compressor speed and injected refrigerant state on the heating performance of the system were discussed in depth.According to the results,the control strategies during start-up stage have been discussed in the end of the article.The study provides a practical control strategy for the RIHP system during the start-up stage of electric vehicles,helping to efficiently operate electric vehicles in cold regions. 展开更多
关键词 refrigerant injection heat pump system heating performance electric vehicle start-up stage control optimization
原文传递
Thermal Efficiency Optimization of a Ground Source Heat Pump System by Assistant Preheating/Precooling: A Case Study on a Heating-Load Dominated Building
17
作者 LUO Jin ZHANG Qi +1 位作者 PRIESS Anna ROHN Joachim 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第6期1948-1958,共11页
Operation strategies of Ground Source Heat Pump System(GSHPS) such as continuous or intermittent approaches have been extensively studied. In this work, a novel strategy was proposed to maximize the energy efficiency ... Operation strategies of Ground Source Heat Pump System(GSHPS) such as continuous or intermittent approaches have been extensively studied. In this work, a novel strategy was proposed to maximize the energy efficiency of GSHPS. In this approach, the buildings was first air-conditioned by the preheating/precooling mode and the rest thermal load was covered by the heat pump(HP) mode. The system performance can then be optimized by considering the combination of these two operating modes. A case study was made to examine the thermal performance of a GSHPS installed in Nuremberg, Germany. Thermal performance of the HP and the preheating/precooling operating modes was examined. The system was optimized by deploying the assistant preheating/precooling approach and over one-year period monitoring showed that the seasonal Coefficient of Performance(COP) of the GSHPS was 4.12 in winter and 5.01 in summer. These COP values are higher than that of the conventional GSHPS. Thus, this proposed strategy could be an efficient way to improve the thermal performance of GSHPS. 展开更多
关键词 ground source heat pump system ground-air heat exchanger ground temperature response preheating and precooling
原文传递
Investigation of energy-efficient heat pump assisted heterogeneous azeotropic distillation for separating of acetonitrile/ethyl acetate/n-hexane mixture 被引量:1
18
作者 Xinhao Li Qing Ye +4 位作者 Jinlong Li Lingqiang Yan Xue Jian Licheng Xie Jianyu Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第3期20-33,共14页
The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ... The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ternary mixture. The proposed scheme is optimized via the simulated annealing algorithm and minimum total annual cost(TAC) is used as objective functions. To minimize energy consumption,heat pump is added on the basis of optimal heterogeneous azeotropic distillation and heat integration technology is used to further improve the energy recovery. The TAC, gas emission, energy consumption and exergy destruction are used to discuss the economy and environmental protection of processes.Among all the processes, the heat pump with higher preheating temperature(HPT) assisted HAD process by combining with heat integration(HAD-HPT-HI) has best performances on economic, environment,energy and exergy. Compared with conventional HAD process, the HAD-HPT-HI achieves the reductions of 52.17%, 68.86%, 65.87% and 65.46% on TAC, total energy consumption, gas emissions and exergy destruction, respectively. 展开更多
关键词 Heterogeneous azeotropic distillation ENERGY-SAVING SA algorithm heat pump
下载PDF
Novel Radiation-Adjustable Heating Terminal Based on Flat Heat Pipe Combined with Air Source Heat Pump
19
作者 Yifan Wu Hongli Sun +3 位作者 Mengfan Duan Borong Lin Hengxin Zhao Chaohung Liu 《Engineering》 SCIE EI CAS CSCD 2023年第1期192-207,共16页
The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking c... The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. However, as a major component of space heating, heating terminals might not fit well with ASHP in order to achieve both intermittency and comfort. Therefore, this study proposes a novel radiation-adjustable heating terminal combined with an ASHP to achieve electrification, intermittency, and better thermal comfort. Radiant terminals currently suffer from three major problems: limited maximum heating capacity, inability to freely adapt, and difficulty with combining them with ASHPs. These problems were solved by improving the structural design of the novel terminal (Improvement A–E). Results showed that the maximum heating capacity increased by 23.6% and radiation heat transfer ratio from 10.1% to 30.9% was provided for users with the novel terminal. Further, new flat heat pipe (FHP) design improved stability (compressor oil return), intermittency (refrigerant thermal inertia), and safety (refrigerant leakage risk) by reducing the length of exposed refrigerant pipes. Furthermore, a new phased operation strategy was proposed for the novel terminal, and the adjustability of the terminal was improved. The results can be used as reference information for decarbonizing buildings by electrifying heating terminals. 展开更多
关键词 Novel heating terminal Air-source heat pump Structural impr ovement design Maximum heating capacity Rapid adjustability Room temperature distribution
下载PDF
Synthesis and Design of Distillation Columns for Wide-Boiling Binary Mixtures with Vapor Recompression Heat Pumps
20
作者 Shi Li 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2023年第4期127-138,共12页
The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column... The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column. However, the separation of wide-boiling binary mixtures leads to substantial temperature differences between the top and bottom of the column. This limits the applicability of conventional VRHP due to high capital costs and strict performance requirements of the compressor. To overcome these challenges and to accommodate compressor operating conditions, a novel synthesis and design method is introduced to integrate VRHPs with wide-boiling binary mixture distillation columns(WBMDCs). This method enables quick determination of an initial configuration for the integrated WBMDC-VRHP system and helps identify the optimum configuration with the minimum total annual cost. Two examples, namely the separation of benzene/toluene and isopropanol/chlorobenzene, are employed to derive optimum configurations of the WBMDC-VRHP and compare them with the WBMDC. A systematic comparison between the WBMDC-VRHP and WBMDC demonstrates the superior steady-state performance and economic efficiency of the WBMDC-VRHP. 展开更多
关键词 vapor recompression heat pump wide-boiling binary mixtures distillation column energy saving synthesis and design
下载PDF
上一页 1 2 141 下一页 到第