Multi-period heat exchanger network(HEN) retrofit is usually performed by targeting and matching heat transfer areas. In this paper, based on the reverse order matching method we proposed previously, three strategies ...Multi-period heat exchanger network(HEN) retrofit is usually performed by targeting and matching heat transfer areas. In this paper, based on the reverse order matching method we proposed previously, three strategies of matching heat transfer areas are proposed to minimize the investment cost for the retrofit of HEN in multiperiod, in which replacement of heat exchangers, addition of heat exchangers and addition of heat transfer areas are performed. We demonstrate the procedures through three scenarios, including maximum number of substituted heat exchangers after retrofit, minimum additional heat transfer areas in the retrofitted HEN, and minimum investment cost for retrofit. The strategies are extended to a single period HEN retrofit problem. The results of multi-period and single period HEN retro fit problems indicate the effectiveness of the strategies. Moreover, these results are better than those reported in literature. The strategies are simple and easy to implement,which are of great benefit to large-scale HEN retrofit in practice.展开更多
A calculation method of heat transfer area for vertical natural circulated steam generator was introduced. According to the design requirements of steam generator 55/19 of CPR1000, its heat transfer area was calculate...A calculation method of heat transfer area for vertical natural circulated steam generator was introduced. According to the design requirements of steam generator 55/19 of CPR1000, its heat transfer area was calculated based on this method. The results show that the accuracy of partitional and overall calculation method is almost the same, but the result is different when using different calculation models. And the results are compared with the foreign companies for 55/19 steam generator.展开更多
It is not ethical to conduct experiments on infants regarding the thermal environment. Therefore, to examine the thermal environment of infants, experiments and simulations using a human body thermal model may be feas...It is not ethical to conduct experiments on infants regarding the thermal environment. Therefore, to examine the thermal environment of infants, experiments and simulations using a human body thermal model may be feasible by clarifying the human body coefficient values of infants. When focusing on the heat transfer area of the infant’s body coefficient values, the body surface area and solar radiation area factor have only been clarified as the standard. The essential basic data for examining the thermal environment of infants have not been sufficiently obtained. Therefore, the purpose of this study was to determine the clothing area factor for infants’ clothing in a typical season. The clothing area factor of infants clothed in summer, mid-season, and winter clothing was measured using a photographic method. The clothing area factor was 1.22, 1.42, and 1.90 for summer, mid-season, and winter clothing, respectively, indicating a significant seasonal difference. It was also found that the clothing area factor was significantly greater for infants than for adults.展开更多
Understanding how the transpiration of this vegetation type responds to environmental stress is important for determining the wa-ter-balance dynamics of the riparian ecosystem threatened by groundwater depletion. Tran...Understanding how the transpiration of this vegetation type responds to environmental stress is important for determining the wa-ter-balance dynamics of the riparian ecosystem threatened by groundwater depletion. Transpiration and sap flow were measured using the heat-pulse technique. The results were then projected up to the stand level to investigate the stand’s water-use in relation to climate forcing in the desert riparian forest in an extreme arid region. This study took place from April through October 2003 and from May through October 2004. The experimental site was selected in the Populus euphratica Forest Reserve (101o10' E, 41o59' N) in Ejina county, in the lower Heihe River basin, China. The sapwood area was used as a scalar to extrapolate the stand-water consumption from the whole trees’ water consumption measured by the heat-pulse velocity recorder (HPVR). Scale transferring from a series of individual trees to a stand was done according to the existing natural variations between trees under given environmental conditions. The application of the biometric parameters available from individual tree and stand levels was proved suitable for this purpose. A significant correlation between the sapwood area and tree diameter at breast height (DBH) was found. The prediction model is well fitted by the power model. On the basis of the prediction model, the sapwood area can be cal-culated by DBH. The sap-flow density can then be used to extrapolate the stand-water use by means of a series of mathematical models.展开更多
基金Supported by the National Natural Science Foundation of China(21376188,21176198)
文摘Multi-period heat exchanger network(HEN) retrofit is usually performed by targeting and matching heat transfer areas. In this paper, based on the reverse order matching method we proposed previously, three strategies of matching heat transfer areas are proposed to minimize the investment cost for the retrofit of HEN in multiperiod, in which replacement of heat exchangers, addition of heat exchangers and addition of heat transfer areas are performed. We demonstrate the procedures through three scenarios, including maximum number of substituted heat exchangers after retrofit, minimum additional heat transfer areas in the retrofitted HEN, and minimum investment cost for retrofit. The strategies are extended to a single period HEN retrofit problem. The results of multi-period and single period HEN retro fit problems indicate the effectiveness of the strategies. Moreover, these results are better than those reported in literature. The strategies are simple and easy to implement,which are of great benefit to large-scale HEN retrofit in practice.
文摘A calculation method of heat transfer area for vertical natural circulated steam generator was introduced. According to the design requirements of steam generator 55/19 of CPR1000, its heat transfer area was calculated based on this method. The results show that the accuracy of partitional and overall calculation method is almost the same, but the result is different when using different calculation models. And the results are compared with the foreign companies for 55/19 steam generator.
文摘It is not ethical to conduct experiments on infants regarding the thermal environment. Therefore, to examine the thermal environment of infants, experiments and simulations using a human body thermal model may be feasible by clarifying the human body coefficient values of infants. When focusing on the heat transfer area of the infant’s body coefficient values, the body surface area and solar radiation area factor have only been clarified as the standard. The essential basic data for examining the thermal environment of infants have not been sufficiently obtained. Therefore, the purpose of this study was to determine the clothing area factor for infants’ clothing in a typical season. The clothing area factor of infants clothed in summer, mid-season, and winter clothing was measured using a photographic method. The clothing area factor was 1.22, 1.42, and 1.90 for summer, mid-season, and winter clothing, respectively, indicating a significant seasonal difference. It was also found that the clothing area factor was significantly greater for infants than for adults.
基金supported by the National Natural Science Foundation of China (40725001 40501012)+1 种基金drought mete-orological scientific research fund projects (IAM200707)the Knowledge Innovation Program from the Chinese Academy of Sciences (KZCX2-XB2-04)
文摘Understanding how the transpiration of this vegetation type responds to environmental stress is important for determining the wa-ter-balance dynamics of the riparian ecosystem threatened by groundwater depletion. Transpiration and sap flow were measured using the heat-pulse technique. The results were then projected up to the stand level to investigate the stand’s water-use in relation to climate forcing in the desert riparian forest in an extreme arid region. This study took place from April through October 2003 and from May through October 2004. The experimental site was selected in the Populus euphratica Forest Reserve (101o10' E, 41o59' N) in Ejina county, in the lower Heihe River basin, China. The sapwood area was used as a scalar to extrapolate the stand-water consumption from the whole trees’ water consumption measured by the heat-pulse velocity recorder (HPVR). Scale transferring from a series of individual trees to a stand was done according to the existing natural variations between trees under given environmental conditions. The application of the biometric parameters available from individual tree and stand levels was proved suitable for this purpose. A significant correlation between the sapwood area and tree diameter at breast height (DBH) was found. The prediction model is well fitted by the power model. On the basis of the prediction model, the sapwood area can be cal-culated by DBH. The sap-flow density can then be used to extrapolate the stand-water use by means of a series of mathematical models.