期刊文献+
共找到46篇文章
< 1 2 3 >
每页显示 20 50 100
Tailoring of a robust asymmetric aramid nanofibers/MXene aerogel film for enhanced infrared thermal camouflage and Joule heating performances
1
作者 Wanbin Dang Wei Guo +1 位作者 Wenting Chen Qiuyu Zhang 《Nano Research》 SCIE EI CSCD 2024年第3期1990-1998,共9页
The development of infrared(IR)surveillance technology has led to a growing interest in thermal camouflage.However,the trade-off relationship between low IR-emissivity and thermal insulation hinders the advance of the... The development of infrared(IR)surveillance technology has led to a growing interest in thermal camouflage.However,the trade-off relationship between low IR-emissivity and thermal insulation hinders the advance of thermal camouflage materials.Herein,guided by multi-physics simulation,we show a design of asymmetric aramid nanofibers/MXene(ANF/MXene)aerogel film that realizes high-efficient thermal camouflage applications.The rationale is that the asymmetric structure contains a thermal-insulation three-dimensional(3D)network part to prevent effective heat transfer and a low IR-emissivity(~0.3)dense surface layer to suppress radiative heat emission.It is remarkable that the synergy mechanism in the topology structure contributes to over 40%reduction of target radiation temperature.Impressively,the tailored asymmetric ANF/MXene aerogel film also enables sound mechanical properties such as a Young’s modulus of 44.4 MPa and a tensile strength of 1.3 MPa,superior to most aerogel materials.It also exhibits great Joule heating performances including low driving voltage(4 V),fast thermal response(<10 s),and long-term stability,further enabling its versatile thermal camouflage applications.This work offers an innovative design concept to configure multifunctional structures for next-generation thermal management applications. 展开更多
关键词 asymmetric aerogel film low infrared(IR)-emissivity thermal insulation IR thermal camouflage Joule heating performance
原文传递
A Novel Technology for Preparation of High Performance Fiber by Radio Frequency Heating CVD 被引量:1
2
《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第6期637-638,共2页
关键词 A Novel Technology for Preparation of High performance Fiber by Radio Frequency heating CVD RADIO
下载PDF
Implementation of heat exchanger performance testing system of heat transfer and flow resistance 被引量:3
3
作者 操瑞兵 陈亚平 +2 位作者 吴嘉峰 董聪 盛艳军 《Journal of Southeast University(English Edition)》 EI CAS 2012年第1期46-51,共6页
A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, co... A heat transfer performance testing system is presented with its hardware structure, operation principle, and software control and measurement system. Working fluids of the subsystem include thermal conducting oil, compressed air, glycol water solution and water as the heating fluids, and air and water as the cooling fluids. The heat transfer performance testing of heat exchangers can be conducted not only for a conventional one heating fluid to one cooling fluid, but also for a compound air cooling heat exchanger with two or three heating fluids in parallel or in series. The control and measurement system is implemented based on a LabVIEW software platform, consisting of the data acquisition and process system, and the automotive operation and control system. By using advanced measuring instruments combined with sound computer software control, the testing system has characteristics of a compact structure, high accuracy, a wide range of testing scope and a friendly operation interface. The uncertainty of the total heat transfer coefficient K is less than 5%. The testing system provides a reliable performance testing platform for designing and developing new heat exchangers. 展开更多
关键词 heat exchanger heat transfer performance testing system LABVIEW
下载PDF
Large-scale physical simulation of injection and production of hot dry rock in Gonghe Basin,Qinghai Province,China
4
作者 ZHAO Peng ZHU Haiyan +4 位作者 LI Gensheng CHEN Zuo CHEN Shijie SHANGGUAN Shuantong QI Xiaofei 《Petroleum Exploration and Development》 SCIE 2024年第3期741-752,共12页
Based on the independently developed true triaxial multi-physical field large-scale physical simulation system of in-situ injection and production,we conducted physical simulation of long-term multi-well injection and... Based on the independently developed true triaxial multi-physical field large-scale physical simulation system of in-situ injection and production,we conducted physical simulation of long-term multi-well injection and production in the hot dry rocks of the Gonghe Basin,Qinghai Province,NW China.Through multi-well connectivity experiments,the spatial distribution characteristics of the natural fracture system in the rock samples and the connectivity between fracture and wellbore were clarified.The injection and production wells were selected to conduct the experiments,namely one injection well and two production wells,one injection well and one production well.The variation of several physical parameters in the production well was analyzed,such as flow rate,temperature,heat recovery rate and fluid recovery.The results show that under the combination of thermal shock and injection pressure,the fracture conductivity was enhanced,and the production temperature showed a downward trend.The larger the flow rate,the faster the decrease.When the local closed area of the fracture was gradually activated,new heat transfer areas were generated,resulting in a lower rate of increase or decrease in the mining temperature.The heat recovery rate was mainly controlled by the extraction flow rate and the temperature difference between injection and production fluid.As the conductivity of the leak-off channel increased,the fluid recovery of the production well rapidly decreased.The influence mechanisms of dominant channels and fluid leak-off on thermal recovery performance are different.The former limits the heat exchange area,while the latter affects the flow rate of the produced fluid.Both of them are important factors affecting the long-term and efficient development of hot dry rock. 展开更多
关键词 hot dry rock simulation of injection and production heat extraction performance CONDUCTIVITY dominant channel fluid leak-off
下载PDF
Numerical simulation of heat release performance of filling body under condition of heat extracted by fluid flowing in buried tube 被引量:6
5
作者 ZHANG Xiao-yan LIU Li +2 位作者 LIU Lang LIU Lu JIA Yu-hang 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第8期2160-2174,共15页
It is the basic requirement of the synergetic exploitation of deep mineral resources and geothermal resources to arrange the heat transfer tube in filling body. The heat release performance of filling body directly im... It is the basic requirement of the synergetic exploitation of deep mineral resources and geothermal resources to arrange the heat transfer tube in filling body. The heat release performance of filling body directly impacts on the exploiting efficiency of geothermal energy. Based on heat transfer theory, a three-dimensional unsteady heat transfer model of filling body is established by using FLUENT simulation software. Taking the horizontal U-shaped buried pipe as research object, the variation of temperature field in filling body around buried pipe is analyzed during the heat release process of filling body;the initial temperature of filling body, the diameter of buried pipe, the inlet temperature and inlet velocity of heat transfer fluid influencing of coupling heat transfer, which exists between heat transfer fluid and surrounding filling body within a certain axial distance of buried tube, and influencing of temperature difference between inlet and outlet of heat transfer fluid and on heat transfer performance of filling body are also discussed. It not only lays a theoretical foundation for the synergetic exploitation of mineral resources and geothermal energy in deep mines, but also provides a reference basis for the arrangement of buried pipes in filling body as well as the selection of working conditions for heat transfer fluid. 展开更多
关键词 filling body buried pipe heat transfer fluid heat release performance
下载PDF
Effects of bending on heat transfer performance of axial micro-grooved heat pipe 被引量:5
6
作者 蒋乐伦 汤勇 潘敏强 《Journal of Central South University》 SCIE EI CAS 2011年第2期580-586,共7页
Heat pipe is always bent in the typical application of electronic heat dissipation at high heat flux,which greatly affects its heat transfer performance. The capillary limit of heat transport in the bent micro-grooved... Heat pipe is always bent in the typical application of electronic heat dissipation at high heat flux,which greatly affects its heat transfer performance. The capillary limit of heat transport in the bent micro-grooved heat pipes was analyzed in the vapor pressure drop,the liquid pressure drop and the interaction of the vapor with wick fluid. The bent heat pipes were fabricated and tested from the bending angle,the bending position and the bending radius. The results show that temperature difference and thermal resistance increase while the heat transfer capacity of the heat pipe decreases,with the increase of the bending angles and the bending position closer to the vapor section. However,the effects of bending radius can be ignored. The result agrees well with the predicted equations. 展开更多
关键词 electronics cooling system axial micro-grooved heat pipe BENDING heat transfer performance
下载PDF
Performance of underground heat storage system in a double-film-covered greenhouse 被引量:4
7
作者 WANG Yong-wei LIANG Xi-feng 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2006年第4期279-282,共4页
An underground heat storage system in a double-film-covered greenhouse and an adjacent greenhouse without the heat storage system were designed on the basis of plant physiology to reduce the energy consumption in gree... An underground heat storage system in a double-film-covered greenhouse and an adjacent greenhouse without the heat storage system were designed on the basis of plant physiology to reduce the energy consumption in greenhouses. The results indicated that the floor temperature was respectively 5.2℃, 4.6℃ and 2.0 ℃ higher than that of the soil in the adjacent reference greenhouse after heat storage in a clear, cloudy and overcast sky in winter. Results showed that the temperature and humidity were feasible for plant growth in the heat saving greenhouse. 展开更多
关键词 GREENHOUSE Underground heat storage system performance of heat storage Energy saving
下载PDF
Heat transfer performance testing of a new type of phase change heat sink for high power light emitting diode 被引量:2
8
作者 XIANG Jian-hua ZHANG Chun-liang +2 位作者 ZHOU Chao LIU Gui-yun ZHOU Wei 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第7期1708-1716,共9页
In view of the limitations of solid metal heat sink in the heat dissipation of high power light emitting diode (LED), a kind of miniaturized phase change heat sink is developed for high power LED packaging. First, t... In view of the limitations of solid metal heat sink in the heat dissipation of high power light emitting diode (LED), a kind of miniaturized phase change heat sink is developed for high power LED packaging. First, the fabrication process of miniaturized phase change heat sink is investigated, upon which all parts of the heat sink are fabricated including main-body and end-cover of the heat sink, the formation of three-dimensional boiling structures at the evaporation end, the sintering of the wick, and the encapsulation of high power LED phase change heat sink. Subsequently, with the assistance of the developed testing system, heat transfer performance of the heat sink is tested under the condition of natural convection, upon which the influence of thermal load and working medium on the heat transfer performance is investigated. Finally, the heat transfer performance of the developed miniaturized phase change heat sink is compared with that of metal solid heat sink. Results show that the developed miniaturized phase change heat sink presents much better heat transfer performance over traditional metal solid heat sink, and is suitable for the packaging of high power LED. 展开更多
关键词 miniaturized phase change heat sink three-dimensional microgrooves sintered wick heat transfer performance testing
下载PDF
Monitoring actual performance of ground source heat pump system using GPRS-based data transmission: A case analysis in Tangshan 被引量:2
9
作者 杜红普 孔祥飞 +1 位作者 李敏 齐承英 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1554-1562,共9页
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is... The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability. 展开更多
关键词 ground source heat pump monitoring operation performance
下载PDF
Heat Transfer Performance and Structural Optimization of a Novel Micro-channel Heat Sink
10
作者 Jianhua Xiang Liangming Deng +3 位作者 Chao Zhou Hongliang Zhao Jiale Huang Sulian Tao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第2期189-200,共12页
With the advent of the 5G era,the design of electronic equipment is developing towards thinness,intelligence and multi-function,which requires higher cooling performance of the equipment.Micro-channel heat sink is pro... With the advent of the 5G era,the design of electronic equipment is developing towards thinness,intelligence and multi-function,which requires higher cooling performance of the equipment.Micro-channel heat sink is promising for the heat dissipation of super-thin electronic equipment.In this study,thermal resistance theoretical model of the micro-channel heat sink was first established.Then,fabrication process of the micro-channel heat sink was introduced.Subsequently,heat transfer performance of the fabricated micro-channel heat sink was tested through the developed testing platform.Results show that the developed micro-channel heat sink has more superior heat dissipation performance over conventional metal solid heat sink and it is well suited for high power LEDs application.Moreover,the micro-channel structures in the heat sink were optimized by orthogonal test.Based on the orthogonal optimization,heat dissipation performance of the micro-channel radiator was further improved. 展开更多
关键词 MICRO-CHANNEL Phase change heat sink Heat transfer performance testing Finite element simulation Orthogonal test
下载PDF
Theoretical and experimental research on heat transfer performance of the semi-open heat pipe
11
作者 Hua ZHU Bo ZHUAN +1 位作者 Jin-jun TAN Rong-hua HONG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第3期410-415,共6页
This paper focuses on the heat transfer performance of semi-open heat pipe which is a new type of heat pipe. After analyzing its condensation heat transfer mechanisms theoretically, several semi-open heat pipes in dif... This paper focuses on the heat transfer performance of semi-open heat pipe which is a new type of heat pipe. After analyzing its condensation heat transfer mechanisms theoretically, several semi-open heat pipes in different length ratios and upper hole diameters are studied experimentally and compared with the same dimensions closed heat pipes. Experimental results show that the heat transfer performance of semi-open heat pipe becomes better by increasing heat transfer rate. At the first transitional point, the heat transfer performance of semi-open heat pipe approaches the level of the closed heat pipe. It is suitable to choose upper small hole about 1 mm in diameter and length ratio larger than 0.6 for the semi-open heat pipe. 展开更多
关键词 Semi-open heat pipe Heat transfer performance Closed heat pipe First transitional point
下载PDF
Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target
12
作者 Lei LI Le HAN +6 位作者 Pengfei ZI Lei CAO Tiejun XU Nanyu MOU Zhaoliang WANG Lei YIN Damao YAO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第9期194-205,共12页
The divertor target components for the Chinese fusion engineering test reactor(CFETR)and the future experimental advanced superconducting tokamak(EAST)need to remove a heat flux of up to20 MW m-2.In view of such a hig... The divertor target components for the Chinese fusion engineering test reactor(CFETR)and the future experimental advanced superconducting tokamak(EAST)need to remove a heat flux of up to20 MW m-2.In view of such a high heat flux removal requirement,this study proposes a conceptual design for a flat-tile divertor target based on explosive welding and brazing technology.Rectangular water-cooled channels with a special thermal transfer structure(TTS)are designed in the heat sink to improve the flat-tile divertor target’s heat transfer performance(HTP).The parametric design and optimization methods are applied to study the influence of the TTS variation parameters,including height(H),width(W*),thickness(T),and spacing(L),on the HTP.The research results show that the flat-tile divertor target’s HTP is sensitive to the TTS parameter changes,and the sensitivity is T>L>W*>H.The HTP first increases and then decreases with the increase of T,L,and W*and gradually increases with the increase of H.The optimal design parameters are as follows:H=5.5 mm,W*=25.8 mm,T=2.2 mm,and L=9.7 mm.The HTP of the optimized flat-tile divertor target at different flow speeds and tungsten tile thicknesses is studied using the numerical simulation method.A flat-tile divertor mock-up is developed according to the optimized parameters.In addition,high heat flux(HHF)tests are performed on an electron beam facility to further investigate the mock-up HTP.The numerical simulation calculation results show that the optimized flat-tile divertor target has great potential for handling the steady-state heat load of 20 MW m-2under the tungsten tile thickness<5 mm and the flow speed7 m s^(-1).The heat transfer efficiency of the flat-tile divertor target with rectangular cooling channels improves by13%and30%compared to that of the flat-tile divertor target with circular cooling channels and the ITER-like monoblock,respectively.The HHF tests indicate that the flat-tile divertor mock-up can successfully withstand 1000 cycles of20 MW m-2of heat load without visible deformation,damage,and HTP degradation.The surface temperature of the flat-tile divertor mock-up at the 1000th cycle is only930℃.The flat-tile divertor target’s HTP is greatly improved by the parametric design and optimization method,and is better than the ITER-like monoblock and the flat-tile mock-up for the WEST divertor.This conceptual design is currently being applied to the engineering design of the CFETR and EAST flat-tile divertors. 展开更多
关键词 CFETR heat transfer performance parametric design and optimization HHF tests flat-tile divertor target
下载PDF
Heat Dissipation Performance of Metal Core Printed Circuit Board with Micro Heat Exchanger
13
作者 Diancheng Qin Kewei Liang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2020年第1期91-96,共6页
A Metal Core Printed Circuit Board with Micro Heat Exchanger(MHE MCPCB)was introduced for thermal management of high power LED.A comparative study was performed between 4 W/(m·K)regular MCPCB and this novel MCPCB... A Metal Core Printed Circuit Board with Micro Heat Exchanger(MHE MCPCB)was introduced for thermal management of high power LED.A comparative study was performed between 4 W/(m·K)regular MCPCB and this novel MCPCB to investigate the heat dissipation performance of this novel MCPCB.It was found that MHE MCPCB can obviously enhance the comprehensive optical properties of LED in comparison with 4 W/(m·K)regular MCPCB.Additionally,thermal contact resistance confining a dominant part of heat within the micro heat exchanger to achieve high efficient heat dissipation was proved. 展开更多
关键词 MHE MCPCB heat dissipation performance LED optical property
下载PDF
Effects of Heat Exchange Tube Structural Parameters on Performance of Vehicle Radiator
14
作者 Zeyan Liu Xilei Kong +3 位作者 Xiaobiao Han Hui Liu Quanzhen Wang Zhenling Wang 《Journal of Power and Energy Engineering》 2020年第9期1-7,共7页
In order to improve the performance of vehicle radiators, a two-dimensional heat transfer steady-state model of the radiator was set up. The influence of the structural parameters (axial ratio) of the heat exchange tu... In order to improve the performance of vehicle radiators, a two-dimensional heat transfer steady-state model of the radiator was set up. The influence of the structural parameters (axial ratio) of the heat exchange tube on the windward side on the heat transfer performance of the radiator was studied. With the increase of the axial ratio of the heat exchange tube on the windward side, the heat exchange capacity of the heat exchange tube surface slightly decreases. The heat exchange area increases significantly, which increases the total heat exchange of the radiator and improves the heat transfer performance of the radiator. When the axial ratio increases from 1.0 to 2.0, the average surface heat transfer capacity decreases from 5664.16</span><span style="font-family:""> </span><span style="font-family:Verdana;">W/m<sup>2</sup> to 5623.57</span><span style="font-family:""> </span><span style="font-family:Verdana;">W/m<sup>2</sup>. 展开更多
关键词 Vehicle Radiator Heat Transfer performance Heat Exchange Tube Structure Parameters Axial Ratio
下载PDF
Experimental study on the operating performance of the air source heat pump(ASHP)with variable outdoor airflow rate under the standard frosting condition
15
作者 Shimin Liang Han Wang +4 位作者 Xuefeng Gao Xiaohui Tian Hui Zhu Songtao Hu Chunwen Lin 《Energy and Built Environment》 EI 2024年第5期719-726,共8页
Frosting is a common phenomenon of the ASHP under the heating mode in winter,and the outdoor air flow rate flowing through the evaporator of the ASHP was always thought to be a major contributor.In order to validate i... Frosting is a common phenomenon of the ASHP under the heating mode in winter,and the outdoor air flow rate flowing through the evaporator of the ASHP was always thought to be a major contributor.In order to validate its contribution,effects of outdoor fan airflow rate on the performance of air source heat pumps(ASHPs)were investigated under the winter heating condition.The experiment was conducted in a laboratory at the standard 2℃ air dry bulb temperature(DB)/1℃ air wet bulb temperature(WB)frosting condition,which enabled the analysis of the operating performance,frosting performance,and heating performance of the ASHP unit by changing the airflow rate of the outdoor fan.Results showed that as the airflow rate of the outdoor fan reduced from 100%to 36%,the operating performance decline and the elevated frosting-defrosting loss were observed.Meanwhile,both the frosting rate and the operating efficiency during frosting-defrosting cycles showed an increasing trend then followed by decreasing tendency.The maximum frosting rate and operating efficiency were 0.92 g/m^(2).min and 2.92,respectively,which were observed at 74%airflow rate of the outdoor fan of the ASHP unit.The observation implied the existence of the“minimum frosting suppression airflow rate”.At 36%airflow rate of the outdoor fan of the ASHP unit,however,the performance of the ASHP unit was attenuated greatly,with the frosting-defrosting efficiency loss coefficient of 0.47,the heating capacity and COP reduction by 51.5 and 38.8%,respectively.These findings provided significant references to the optimization of ASHPs performance with variable airflow rate of the outdoor fan under frosting conditions. 展开更多
关键词 ASHP Variable outdoor airflow rate FROSTING heating performance
原文传递
Numerical simulation of flow and heat transfer of n-decane in sub-millimeter spiral tube at supercritical pressure
16
作者 Jiahao Xing Huaizhi Han +1 位作者 Ruitian Yu Wen Luo 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第8期173-185,共13页
The flow and heat transfer characteristics of n-decane in the sub-millimeter spiral tube(SMST) at supercritical pressure(p = 3 MPa) are studied by the RNG k-ε numerical model in this paper. The effects of various Rey... The flow and heat transfer characteristics of n-decane in the sub-millimeter spiral tube(SMST) at supercritical pressure(p = 3 MPa) are studied by the RNG k-ε numerical model in this paper. The effects of various Reynolds numbers(Re) and structural parameters pitch(s) and spiral diameter(D) are analyzed.Results indicate that the average Nusselt numberNu and friction factorNu increase with an increase in Re, and decrease with an increase in D/d(tube diameter). In terms of the structural parameter s/d, it is found that as s/d increases, the Nu first increase, and then decrease. and the critical structural parameter is s/d = 4. Compared with the straight tube, the SMST can improve Nu by 34.8% at best, while it can improve Nu by 102.1% at most. In addition, a comprehensive heat transfer coefficient is applied to analyze the thermodynamic properties of SMST. With the optimal structural parameters of D/d = 6 and s/d = 4, the comprehensive heat transfer factor of supercritical pressure hydrocarbon fuel in the SMST can reach 1.074. At last, correlations of the average Nusselt number and friction factor are developed to predict the flow and heat transfer of n-decane at supercritical pressure. 展开更多
关键词 Sub-millimeter spiral tube Supercritical pressure Numerical simulation Heat transfer performance
下载PDF
Heat Storage Performance of PCM in a Novel Vertical Pointer-Shaped Finned Latent Heat Tank
17
作者 MAO Qianjun ZHU Yuanyuan LI Tao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第2期422-434,共13页
The heat storage performance of latent heat storage systems is not good due to the poor thermal conductivity of phase change materials.In this paper,a new type of pointer-shaped fins combining rectangular and triangul... The heat storage performance of latent heat storage systems is not good due to the poor thermal conductivity of phase change materials.In this paper,a new type of pointer-shaped fins combining rectangular and triangular fins has been employed to numerically simulate the melting process in the heat storage tank,and the fin geometry parameter effects on heat storage performance have been studied.The results indicate that compared with the bare tube and the rectangular finned tank,the melting time of the phase change material in the pointer-shaped finned tank is reduced by 64.2%and 15.1%,respectively.The closer the tip of the triangular fin is to the hot wall,the better the heat transfer efficiency.The optimal height of the triangular fin is about 8 mm.Increasing the number of fins from 4 to 6 and from 6 to 8 reduces the melting time by 16.0%and 16.7%respectively.However,increasing the number of fins from 8 to 10 only reduces the melting time by 8.4%.When the fin dimensionless length is increased from 0.3 to 0.5 and from 0.5 to 0.7,the melting time is shortened by 17.5%and 13.0%.But the melting time is only reduced by 2.9%when the dimensionless fin length is increased from 0.7 to 0.9.For optimising the design of the thermal storage system,the results can provide a reference value. 展开更多
关键词 thermal energy storage phase change material pointer-shaped fins heat storage performance
原文传递
Geothermal extraction performance in fractured granite from Gonghe Basin,Qinghai province,China:Long-term injection and production experiment
18
作者 Haiyan Zhu Shijie Chen +2 位作者 Qiang Fu Peng Zhao John D.McLennan 《Rock Mechanics Bulletin》 2024年第2期111-123,共13页
The efficient exploitation of geothermal energy through enhanced geothermal systems(EGS)has been a relevant topic for hot dry rock(HDR)geothermal resources.When cryogenic fluid is injected into a thermal reservoir,imp... The efficient exploitation of geothermal energy through enhanced geothermal systems(EGS)has been a relevant topic for hot dry rock(HDR)geothermal resources.When cryogenic fluid is injected into a thermal reservoir,improving heat exchange efficiency is key to achieving the optimal exploitation of HDR.In this paper,granite outcrops from Gonghe Basin were used as the testing sample.The natural fractures in the granite samples were relatively well developed.To simulate long-term injection and production from multi-wells in situ,physical ex-periments were performed in a newly-developed,in-house large-scale true triaxial experimental system.Geothermal extraction performance of an HDR was simulated for long-term injection and production operations.Simultaneously,the mode of one-injection and multiple-production wells was represented.In the paper,the ef-fects of the production-injection well spacing,the number of production wells and the injection rate on the production temperature and flow rate are discussed.The results show that,during long-term injection and pro-duction,there are two stages of production temperature variation,namely stabilization and attenuation.When the number of the production wells is increased,the heat extraction efficiency is accelerated.Moreover,competitive diversion of fluid among fractures occurred due to different conductivities.Furthermore,under different pro-duction modes,the production flow rate contributed differently to the heat extraction.Finally,the effect of the production-injection wells spacing on the heat exchange performance was analyzed;this is mainly reflected in the change of the effective heat exchange area between the rock and the injected fluid.The results emphasize the importance of designing an appropriate production mode and optimizing the injection-production parameters to ensure efficient HDR exploitation. 展开更多
关键词 Enhanced geothermal system(EGS) Long-term injection and production experiment One-injection and multiple-productions mode Large-scale physical simulation experiment Heat extraction performance
原文传递
Fabrication and testing of phase change heat sink for high power LED 被引量:1
19
作者 向建化 张春良 +2 位作者 江帆 刘晓初 汤勇 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第9期2066-2071,共6页
A novel phase change heat sink was fabricated for packaging cooling of high power light emitting diode (LED). 3D structures as enhanced boiling structure in the evaporation surface were composed of a spiral micro-gr... A novel phase change heat sink was fabricated for packaging cooling of high power light emitting diode (LED). 3D structures as enhanced boiling structure in the evaporation surface were composed of a spiral micro-groove along circumferential direction and radial micro-grooves which were processed by ploughing-extrusion (P-E) and stamping, respectively. Meanwhile, the cycle power of refrigerant was supplied by wick of sintered copper powder on internal surface of phase change heat sink. Operational characteristics were tested under different heat loads and refrigerants. The experimental results show that phase change heat sink is provided with a good heat transfer capability and the temperature of phase change heat sink reaches 86.8 ℃ under input power of 10 W LED at ambient temperature of 20 ℃. 展开更多
关键词 high power light emitting diode phase change heat sink enhanced boiling WICK heat transfer performance
下载PDF
Numerical Simulation and Optimization of a Mid-Temperature Heat Pipe Exchanger 被引量:7
20
作者 Jun Du Xin Wu +1 位作者 Ruonan Li Ranran Cheng 《Fluid Dynamics & Materials Processing》 EI 2019年第1期77-87,共11页
In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.... In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.The effects of different operating parameters and fin parameters on the heat transfer performance of heat exchangers are studied.The results show that the heat transfer performance of the mid-temperature gravity heat pipe exchanger is the best when the fin spacing is between 5 mm and 6 mm,the height of the heat pipe is between 12 mm and 13 mm,and the inlet velocity of the fluid is between 2.5 m/s to 3 m/s. 展开更多
关键词 Gravity heat pipe heat exchanger FLUENT numerical simulation heat transfer performance
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部