期刊文献+
共找到1,931篇文章
< 1 2 97 >
每页显示 20 50 100
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
1
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
下载PDF
Early changes in corneal densitometry after FS-LASIK combined with accelerated corneal cross-linking for correction of high myopia
2
作者 Qing-Bao Wang Hong-Sheng Bi +3 位作者 Xiao-Fan Wang Hua Fan Li Li Peng Ji 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1307-1312,共6页
AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHO... AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHODS:In this prospectively study,130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia.Their right eyes were selected for inclusion in the study,of which 65 cases of 65 eyes in the FS-LASIK group,65 patients with 65 eyes in the FS-LASIK Xtra group.Patients were evaluated for corneal densitometry at 1,3,and 6mo postoperatively using Pentacam Scheimpflug imaging.RESULTS:Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant(P>0.05).Layer-by-layer analysis revealed statistically significant differences in the anterior(120μm),central,and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively(all P<0.05),the FS-LASIK Xtra group is higher than that of the FS-LASIK group.Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0–2,2–6,and 6–10 mm(both P<0.05);At 3mo postoperatively,the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0–2 and 2–6 mm(P<0.05).At 6mo postoperatively,there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges(all P>0.05).CONCLUSION:There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia.However,the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery,with the most significant changes observed in the superficial central zone. 展开更多
关键词 femtosecond laser accelerated corneal cross-linking corneal densitometry high myopia femtosecond laser in situ keratomileusis
下载PDF
Clinical Effect Analysis of Posterior Chamber Intraocular Lens Implantation for Correcting High Myopia and Astigmatism
3
作者 Bo Xia Dan Dan Zhao 《Journal of Clinical and Nursing Research》 2024年第8期99-104,共6页
Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the ca... Objective:To explore the corrective effect of posterior chamber intraocular lens implantation with phakic eyes in the treatment of high myopia and astigmatism.Methods:From May 2023,the hospital began to collect the case data of diagnosis and treatment of high myopia and astigmatism.By May 2024,310 cases were included,all of which were treated with posterior chamber intraocular lens implantation.The visual acuity,astigmatism and axial position of the intraocular lens were observed before and after treatment.Results:At different time points after the operation,the patient’s vision was significantly improved compared with that before the operation(P<0.05),and the vision level was equal to or greater than the best-corrected vision before the operation.At different time points after the operation,the average rotation of the intraocular lens was less than 5 degrees.Astigmatism was significantly lower than that before the operation(P<0.05).After the operation,the intraocular pressure increased in 11 cases,accounting for 3.55%,with no adverse complications such as lens turbidity,glare and obvious halo occurring.Conclusion:The posterior chamber intraocular lens implantation with phakic eyes has an ideal correction effect in the treatment of high myopia and astigmatism,which can effectively improve the vision level of patients and reduce the degree of astigmatism,and has high effectiveness and safety. 展开更多
关键词 Posterior chamber intraocular lens implantation in phakic eyes high myopia ASTIGMATISM Corrective effect
下载PDF
Long-term vision-threatening complications of phakic intraocular lens implantation for high myopia 被引量:14
4
作者 Isil Bahar Sayman Muslubas Baran Kandemir +2 位作者 Ayse Yesim Aydin Oral Suleyman Kugu Metin Dastan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期376-380,共5页
AIMTo report the long-term vision-threatening complications in patients who underwent phakic intraocular lens (pIOLs) implantation for high myopia.
关键词 phakic intraocular lens high myopia COMPLICATIONS corneal decompensation rhegmatogenous retinal detachment
下载PDF
Diagnostic ability of ganglion cell complex thickness to detect glaucoma in high myopia eyes by Fourier domain optical coherence tomography 被引量:9
5
作者 Wei-Wei Wang Huai-Zhou Wang +4 位作者 Jian-Rong Liu Xi-Fang Zhang Meng Li Yan-Jiao Huo Xin-Guang Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第5期791-796,共6页
AIM:To evaluate the ability of macular ganglion cell complex(GCC) thickness using Fourier domain optical coherence tomography(FD-OCT) to detect glaucoma in highly myopic eyes.METHODS:Cross-sectional study.A tota... AIM:To evaluate the ability of macular ganglion cell complex(GCC) thickness using Fourier domain optical coherence tomography(FD-OCT) to detect glaucoma in highly myopic eyes.METHODS:Cross-sectional study.A total of 114 participants,consecutively were enrolled.Macular GCC thickness and peripapillary retinal nerve fiber layer(RNFL) thickness were obtained with RTVue FD-OCT.Receiver operating characteristics curves were constructed for each measurement parameter,and areas under the curves(AUCs) were compared.RESULTS:Both the average GCC and average RNFL thickness showed negative correlations with axial length(rGCC=-0.404,P=0.001;rRNFL=-0.561,P〈0.001).The largest AUCs from GCC,and RNFL parameters were 0.968 [global loss volume(GLV)],and 0.855(average RNFL),respectively.GLV was significantly better for detecting high myopic glaucoma than average RNFL(P〈0.001).CONCLUSION:Macular GCC thickness has higher diagnostic power than peripapillary RNFL thickness to discriminate glaucoma patients from non-glaucoma subjects in high myopia. 展开更多
关键词 optical coherence tomography GLAUCOMA high myopia ganglion cell complex
下载PDF
Comparison axial length measurements from three biometric instruments in high myopia 被引量:6
6
作者 Xiao-Gang Wang Jing Dong +2 位作者 Yu-Lan Pu Hui-Jun Liu Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第6期876-880,共5页
AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were include... AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed. 展开更多
关键词 axial length BIOMETRY REPEATABILITY intraocular lens high myopia
下载PDF
The association of lumican polymorphisms and high myopia in a Southern Chinese population 被引量:6
7
作者 Gui-Fang Wang Qing-Shan Ji +3 位作者 Bing Qi Guo-Cheng Yu Lian Liu Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1516-1520,共5页
AIM:To investigate the correlation between lumican(LUM)gene and high myopia in a Southern Chinese population.METHODS:The study comprised of 95 high myopia patients with a spherical equivalent≤-6.5 diopters(D).T... AIM:To investigate the correlation between lumican(LUM)gene and high myopia in a Southern Chinese population.METHODS:The study comprised of 95 high myopia patients with a spherical equivalent≤-6.5 diopters(D).The control group recruited 95 individuals with a spherical equivalent ranging from-0.5 D to+0.5 D.Direct sequencing was used to detect the single nucleotide polymorphisms(SNPs)of LUM gene in coding region.Genotype distributions were tested for Hardy-Weinberg disequilibrium.Genotypic and allelic frequencies were analyzed through Chi-square test or Fisher’s exact test.RESULTS:We identified 3 SNPs of the LUM gene:LUM c.32(rs577456426),LUM c.507(rs17853500)and LUM c.849(rs181915277).Among the three SNPs,the genotype and allele frequencies of rs17853500 showed a significant difference between patients and control subjects(P〈0.05).However,there were no significant differences in rs181915277and rs577456426 between the two groups(P〉0.05).CONCLUSION:LUM c.507 polymorphism may be a risk factor for the pathogenesis of high myopia in the Southern Chinese population. 展开更多
关键词 LUMICAN sclem high myopia single nucleotidepolymorphisms
下载PDF
High myopia as a risk factor in primary open angle glaucoma 被引量:13
8
作者 Sheng-Ju Chen Peng Lu +1 位作者 Wen-Fang Zhang Jian-Hua Lu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第6期750-753,共4页
Glaucoma, one of the leading causes of irreversible blindness in the adult population worldwide, is a progressive optic neuropathy. Primary open angle glaucoma (POAG) is the most commonly reported type of glaucoma in ... Glaucoma, one of the leading causes of irreversible blindness in the adult population worldwide, is a progressive optic neuropathy. Primary open angle glaucoma (POAG) is the most commonly reported type of glaucoma in population based prevalence studies worldwide. Elevated intraocular pressure is a well-known major risk factor for POAG. In addition, there is growing evidence that other risk factors like age, gender, race, refractive error, heredity and systemic factors may play a role in glaucoma pathogenesis. Many studies found that high myopia has been associated with POAG, however, direct and convincing evidences are still lacking. The aim of this review is to summarize the evidences implicating high myopia as a risk factor in the pathogenesis of POAG. 展开更多
关键词 high myopia primary open angle glaucoma risk factor
下载PDF
Association between lumican gene-1554 T/C polymorphism and high myopia in Asian population:a meta-analysis 被引量:5
9
作者 Xuan Liao Xu-Bo Yang +2 位作者 Meng Liao Chang-Jun Lan Long-Qian Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期696-701,共6页
AIMTo investigate the association between lumican gene -1554 T/C polymorphism and high myopia susceptibility.
关键词 LUMICAN high myopia gene polymorphism META-ANALYSIS
下载PDF
Genetic association of COL1A1 polymorphisms with high myopia in Asian population: a Meta-analysis 被引量:5
10
作者 Bo Gong Chao Qu +6 位作者 Xiao-Fang Huang Zi-Meng Ye Ding-Ding Zhang Yi Shi Rong Chen Yu-Ping Liu Ping Shuai 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第8期1187-1193,共7页
AIM: To comprehensively evaluate the potential association of COL1A1 polymorphisms with high myopia by a systematic review and Meta-analysis. METHODS: All association studies on COL1A1 and high myopia reported up to J... AIM: To comprehensively evaluate the potential association of COL1A1 polymorphisms with high myopia by a systematic review and Meta-analysis. METHODS: All association studies on COL1A1 and high myopia reported up to June 10, 2014 in PubMed, Embase, Web of Science, and the Chinese Biomedical Database were retrieved. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were analyzed for single-nucleotide polymorphisms (SNPs) using fixed- and random - effects models according to between-study heterogeneity. Publication bias analyses were conducted by Eggers test. RESULTS: A total of four studies from reported papers were included in this analysis. The Meta-analyses for COL1A1 rs2075555, composed of 2304 high myopia patients and 2272 controls, failed to detect any significant association with high myopia. A total of 971 cases and 649 controls were tested for COL1A1 rs2269336. The association of COL1A1 rs2269336 with high myopia was observed in recessive model (CC vs CG+GG, P = 0.03) and in heterozygous model (CG vsGG, P = 0.04), but not in other models. CONCLUSION: This Meta-analysis shows that COL fill rs2269336 (CC vs CG +GG) affects individual susceptibility to high myopia, whereas there is no association detected between SNPs rs2075555 and high myopia. Given the limited sample size, further investigations including more ethnic groups are required to validate the association. 展开更多
关键词 COL1A1 high myopia ASSOCIATION META-ANALYSIS
下载PDF
Five-year results of refractive outcomes and visionrelated quality of life after SMILE for the correction of high myopia 被引量:7
11
作者 Min Lang Kai-Wei Cao +2 位作者 Ting Liu Ying Zhu Jian Ye 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第9期1365-1370,共6页
AIM:To evaluate the long-term visual,refractive outcomes and vision-related quality of life after small incision lenticule extraction(SMILE)for the correction of high myopia.METHODS:Thirty patients(60 eyes)with high m... AIM:To evaluate the long-term visual,refractive outcomes and vision-related quality of life after small incision lenticule extraction(SMILE)for the correction of high myopia.METHODS:Thirty patients(60 eyes)with high myopia who underwent SMILE more than 5y were selected as the SMILE group.Another 30 high myopia patients(60 eyes)who had worn corrective spectacles for more than 5y were selected as the control group.In SMILE group,the postoperative follow-up time were 3,6 mo,1 and 5y.Uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),spherical equivalent(SE),and ocular axial length(AL)were analyzed.The Chinese version of the National Eye Institute Visual Function Questionnaire-25(CHI-NEI-VFQ-25)was used to evaluate the vision-related quality of life in the SMILE group and the control group.RESULTS:In SMILE group,the mean preoperative SE was-7.29±0.87 D(range-6.00 to-9.125 D).At 5-year follow up,the efficacy index and safety index of SMILE were 1.09±0.18 and 1.19±0.12,respectively.Five years postoperatively,44 eyes(73%)obtained a visual acuity of 20/20 or better.There were no eyes with CDVA loss of one or more Snellen lines.Forty-nine eyes(82%)and 57 eyes(95%)were within±0.50 and±1.00 D of attempted correction at 5-year follow-up,respectively.Forty-eight eyes(80%)had astigmatism<0.50 D at 5-year followup.The postoperative mean SE values at 3,6 mo,1,and 5y were 0.11±0.44,0.07±0.45,-0.02±0.41,and-0.15±0.46 D,respectively.No significant change was observed in the ocular AL from before operation to 5y postoperatively(26.08±0.96 mm vs 26.01±0.94 mm,P=0.068).Compared to the control group,the SMILE group showed a significantly higher total score on the CHI-NEI-VFQ-25(90.14 vs 81.43,P<0.001).CONCLUSION:In the present study,in a long-term follow-up we demonstrate that correcting high myopia with SMILE is safe,effective,and predictable.Vision-related quality of life after SMILE is better in the SMILE group than in the control group who wore corrective spectacles. 展开更多
关键词 small incision lenticule extraction high myopia long-term follow-up
下载PDF
Trends in research related to high myopia from 2010 to 2019:a bibliometric and knowledge mapping analysis 被引量:5
12
作者 Xiao-Dan Zhang Chun-Xia Wang +3 位作者 Hong-Hu Jiang Shuo—Lan Jing Jiang-Yue Zhao Zi-Yan Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第4期589-599,共11页
AIM:To evaluate the global trends in and explore hotspots of high myopia(HM)research.METHODS:This bibliometric analysis was used to reveal the publication trends in HM research field based on the Web of Science Core C... AIM:To evaluate the global trends in and explore hotspots of high myopia(HM)research.METHODS:This bibliometric analysis was used to reveal the publication trends in HM research field based on the Web of Science Core Collection(WoSCC).VOSviewer version 1.6.13 software was used to analyze the data and construct a knowledge map including the yearly publication number,journals,countries,international collaborations,authors,research hotspots,and intellectual base in HM.RESULTS:The search engine found 3544 peer-reviewed publications on HM between 2010 and 2019,and the yearly research output substantially elevated over the past decade.China is the top publishing country,and Sun Yatsen University was the most active academic institution.Jonas JB is the top publishing scientist,and Investigative Ophthalmology and Visual Science(IOVS)was the most productive journal.The highest cited references mainly focused on epidemiology and management.The keywords formed 6 clusters:1)refractive surgery;2)etiology and clinical characteristics;3)the mechanism of eye growth;4)management for myopic maculopathy;5)vitrectomy surgical treatment;6)myopia-associated glaucoma-like optic neuropathy.CONCLUSION:The evaluation of development trends based on the data extracted from WoSCC can provide valuable information and guidance for ophthalmologists and public health researchers to improve management procedures in HM field. 展开更多
关键词 high myopia pathological myopia bibliometric analysis VOSviewer
下载PDF
Measurements of the parapapillary atrophy area and other fundus morphological features in high myopia with or without posterior staphyloma and myopic traction maculopathy 被引量:5
13
作者 Xiao-Xiao Guo Xi Chen +5 位作者 Shan-Shan Li Min Li Xiu-Fen Yang Lu Zhao Ran You Yan-Ling Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第8期1272-1280,共9页
AIM:To investigate the affecting factors of parapapillary gamma and delta zones and other fundus morphological features in high myopia.METHODS:Seventy high myopia patients were included in this retrospective observati... AIM:To investigate the affecting factors of parapapillary gamma and delta zones and other fundus morphological features in high myopia.METHODS:Seventy high myopia patients were included in this retrospective observational study and 47 patients were female.Patients were divided into three groups:no posterior staphyloma(no PS),PS with myopic traction maculopathy(PS with MTM),and PS without MTM using 3-dimensional magnetic resonance imaging and optical coherence tomography.MTM patients were fur ther classified into three types[epiretinal membrane,macular hole,and macular retinoschisis(MRS)].Diameters of the gamma and delta zones were measured among other morphometric variables using fundus photographs.RESULTS:Of the 70 individuals(127 eyes),the mean age was 57.46±13.56y.In univariate analysis,morphological features changed most dramatically in PS with MTM patients,who had the largest gamma zone diameters,the largest disk-fovea distance(DFD)and disk-fovea angle,and the smallest angle kappa and vertical distance of temporal arterial arcade.However,their horizontal delta zone diameter was smaller than in the patients with PS yet without MTM.In multivariate analysis,with axial length(AL)and age adjusted,the horizontal diameter in the delta zone of the PS without MTM group was still significantly larger than in the PS with MTM group(P=0.024).Comparing the three subtypes of MTM patients,the diameters of the gamma zone and DFD in MRS group were the largest.CONCLUSION:The characteristics of the gamma and delta zones change inconsistently in different stages of high myopia.These changes may be associated with anatomical changes caused by local traction.Factors such as PS,AL and age play an important role.These findings may provide a hint about the pathogenesis of traction in high myopia. 展开更多
关键词 high myopia myopization myopic traction maculopathy parapapillary delta zone parapapillary gamma zone posterior staphyloma
下载PDF
Macular Bruch's membrane defects and other myopic lesions in high myopia 被引量:8
14
作者 Li-Hui Meng Ming-Zhen Yuan +1 位作者 Xin-Yu Zhao You-Xin Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第3期466-473,共8页
AIM: To compare the ocular fundus features of highly myopic eyes with and without macular Bruch’s membrane(BM) defects and investigate the associations between macular BM defects and other myopic lesions.METHODS: Thi... AIM: To compare the ocular fundus features of highly myopic eyes with and without macular Bruch’s membrane(BM) defects and investigate the associations between macular BM defects and other myopic lesions.METHODS: This retrospective, observational case series included 262 eyes(139 patients) with high myopia(HM) refractive error ≥-6.0 diopters(D) or axial length ≥26.5 mm from March 2019 to December 2019.The patients underwent a comprehensive ophthalmic examination, including sweptsource optical coherence tomography(SS-OCT).The features of macular BM defects and other ocular fundus lesions were examined in OCT images.RESULTS: Totally 51 eyes(19.5%) were detected with macular BM defects, which were characterized by a lack of BM, retinal pigment epithelium(RPE), and an almost complete loss of photoreceptors or choriocapillaris.Eyes with macular BM defects had worse best-corrected visual acuity(BCVA) than those without(P<0.001).Dome-shaped macula(DSM, P=0.042), retinal cysts(P=0.006), choroidal neovascularization(CNV, P<0.001), choroidal defects and abnormality(P=0.003), scleral defects(P=0.015), scleral deformation(P=0.005), posterior staphyloma(P=0.011), and perforating vessels(P<0.001) occurred more frequently in eyes with macular BM defects.In multivariate analysis, the presence of macular BM defects remained the significant association with presence of DSM(P=0.013), scleral defects(P=0.015), posterior staphyloma(P=0.001), perforating vessels(P<0.001) and CNV(P=0.004).CONCLUSION: Macular BM defects has a prevalence of approximately 20% in HM and it has tight association with other myopic fundus lesions.BM might be crucial in the pathogenesis of myopic fundus lesions due to its biomechanical function.A comprehensive understanding of BM’s role is useful for further researches about myopic lesions. 展开更多
关键词 Bruch’s membrane high myopia swept source optical coherence tomography
下载PDF
Abnormal resting-state functional network centrality in patients with high myopia: evidence from a voxel-wise degree centrality analysis 被引量:4
15
作者 Yu-Xiang Hu Jun-Rong He +7 位作者 Bo Yang Xin Huang Yu-Ping Li Fu-Qing Zhou Xiao-Xuan Xu Yu-Lin Zhong Jun Wang Xiao-Rong Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第11期1814-1820,共7页
AIM: To investigate the functional networks underlying the brain-activity changes of patients with high myopia using the voxel-wise degree centrality(DC) method.METHODS: In total, 38 patients with high myopia(HM... AIM: To investigate the functional networks underlying the brain-activity changes of patients with high myopia using the voxel-wise degree centrality(DC) method.METHODS: In total, 38 patients with high myopia(HM)(17 males and 21 females), whose binocular refractive diopter were-6.00 to-7.00 D, and 38 healthy controls(17 males and 21 females), closely matched in age, sex, and education levels, participated in the study. Spontaneous brain activities were evaluated using the voxel-wise DC method. The receiver operating characteristic curve was measured to distinguish patients with HM from healthy controls. Correlation analysis was used to explore the relationship between the observed mean DC values of the different brain areas and the behavioral performance.RESULTS: Compared with healthy controls, HM patients had significantly decreased DC values in the right inferior frontal gyrus/insula, right middle frontal gyrus, and right supramarginal/inferior parietal lobule(P〈0.05). In contrast, HM patients had significantly increased DC values in the right cerebellum posterior lobe, left precentral gyrus/postcentral gyrus, and right middle cingulate gyrus(P〈0.05). However, no relationship was found between the observed mean DC values of the different brain areas and the behavioral performance(P〉0.05).CONCLUSION: HM is associated with abnormalities in many brain regions, which may indicate the neural mechanisms of HM. The altered DC values may be used as a useful biomarker for the brain activity changes in HM patients. 展开更多
关键词 high myopia degree centrality functional magnetic resonance imaging resting state
下载PDF
Clinical outcomes of transepithelial photorefractive keratectomy versus femtosecond laser assisted keratomileusis for correction of high myopia in South Egyptian population 被引量:4
16
作者 Amr Mounir Engy Mohamed Mostafa +4 位作者 Hatem Ammar Osama Ali Mohammed Alahmady Hamad Alsmman Mahmoud Mohamed Farouk Mohamed Gamal Elghobaier 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第1期129-134,共6页
AIM: To evaluate the safety and efficacy of transepithelial photorefractive keratectomy(t-PRK) with adjuvant mitomycin C(MMC) versus femtosecond laser assisted keratomileusis(Femto-LASIK) in correction of high myopia.... AIM: To evaluate the safety and efficacy of transepithelial photorefractive keratectomy(t-PRK) with adjuvant mitomycin C(MMC) versus femtosecond laser assisted keratomileusis(Femto-LASIK) in correction of high myopia.METHODS: Prospective randomized comparative study including 156 eyes of 156 patients with high myopia and a spherical equivalent refraction(SER) <-6.00 D. They were divided randomly into two groups: Group A included 72 eyes treated with t-PRK with adjuvant MMC and Group B included 84 eyes treated with Femto-LASIK. Visual acuity, SER, corneal topography, pachymetry and keratometry were assessed for 12 mo postoperatively.RESULTS: The preoperative mean SER was-8.86±1.81 and-9.25±1.70 D in t-PRK MMC group and Femto-LASIK respectively(P=0.99) which improved to-0.65±0.43 D and-0.69±0.50 D at 12 mo follow up. Mean SER remained stable during the 12 mo of follow-up, with no statistically significant difference between the two groups(P=0.64). In t-PRK MMC group, only six eyes needed retreatment after six months of follow up. And two eyes showed haze(one reversible haze grade 2, while the other had dense irreversible haze grade 4).CONCLUSION: t-PRK MMC provides safe and satisfactory visual outcomes and acceptable risk as Femto-LASIK in patients with high myopia. 展开更多
关键词 transepithelial photorefractive keratectomy femtosecond laser assisted keratomileusis high myopia corneal haze Egypt
下载PDF
Novel TRPM1 mutations in two Chinese families with early-onset high myopia, with or without complete congenital stationary night blindness 被引量:3
17
作者 Lin Zhou Tuo Li +3 位作者 Yi-Qiao Xing Yin Li Qing-Song Wu Mao-Ju Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第10期1396-1402,共7页
AIM:To investigate the relationship between high myopia [with or without complete congenital stationary night blindness(CSNB1)] and TRPM1 and NYX.METHODS: Two unrelated families with early-onset high myopia(eo HM... AIM:To investigate the relationship between high myopia [with or without complete congenital stationary night blindness(CSNB1)] and TRPM1 and NYX.METHODS: Two unrelated families with early-onset high myopia(eo HM) and 96 normal controls were recruited.Sanger sequencing or clone sequencing were used for mutation screening.Further analyses of the available family members and the 96 normal controls were subsequently conducted to obtain additional evidence of the pathogenicity of these variants.The initial diagnosis of the probands was eo HM.We performed a further comprehensive examination of the available family members after mutations were detected in TRPM1 or NYX. RESULTS: Two novel compound heterozygous mutations in TRPM1 were detected in the recruited families.The proband in family A with eo HM carried a c.2594 C 〉T missense mutation in exon 19 and a c.669 +3_669 +6del AAGT splicing mutation,which was co-segregated with CSNB1 in this family.A patient in family B with a compound heterozygous missense mutation(c.3262 G〉A and c.3250 T〉C) was detected.No mutations were found in NYX.These two identified compound heterozygous mutations were not found in the 96 normal controls.After further examination of the family members,the patients in family A could be diagnosed as eo HM with CSNB1.However due to the limited clinic data,the patient in family B cloud not clearly diagnosed as CSNB1.CONCLUSION: This study has expanded the mutation spectrum of TRPM1 for CSNB1 and additional studiesare needed to elucidate the association between isolated high myopia and TRPM1 and NYX. 展开更多
关键词 TRPM1 NYX MUTATIONS high myopia complete congenital stationary night blindness
下载PDF
Optic disc and peripapillary changes by optic coherence tomography in high myopia 被引量:3
18
作者 Ting Pan Yun Su +3 位作者 Song-Tao Yuan Hang-Cheng Lu Zi-Zhong Hu Qing-Huai Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第5期874-880,共7页
Myopia,a worldwide condition,is a multifactorial disease resulting in many ocular complications.Early onset of myopia has a great tendency to develop high myopia and pathological myopia later in life.The pathophysiolo... Myopia,a worldwide condition,is a multifactorial disease resulting in many ocular complications.Early onset of myopia has a great tendency to develop high myopia and pathological myopia later in life.The pathophysiology and progression of myopia is still unclear.Owing to its involving in visual function,optic disc and peripapillary change in high myopia can't be neglected,and it may help in better understanding of the pathophysiology or mechanism of myopia progression.Recently,advanced imaging techniques have been developed,such as optical coherence tomography(OCT),allowing for better detecting of optic disc and peripapillary change.OCT is a highresolution and noninvasive measurement for detection of ocular structure.Herein,we provide an updated review of optic disc and peripapillary change in OCT image,including its characteristics and clinical significance.We also propose some problems needed further investigation. 展开更多
关键词 high myopia optical coherence tomography optic disc peripapillary
下载PDF
Vitrectomy with internal limiting membrane peeling versus its flap insertion for macular hole in high myopia: a Meta-analysis 被引量:3
19
作者 Ya-Jun Wu Jie Rao +7 位作者 Kang-Rui Wu Na Wu Yi Cheng Xiao-Xuan Xu Li Yan Yi Shao Yu Tian Xiao-Rong Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第1期141-148,共8页
AIM: To compare the anatomic and functional outcomes between vitrectomy with internal limiting membrane(ILM) peeling and internal ILM flap insertion technique for high myopia macular hole(MH).METHODS: Pub Med, Cochran... AIM: To compare the anatomic and functional outcomes between vitrectomy with internal limiting membrane(ILM) peeling and internal ILM flap insertion technique for high myopia macular hole(MH).METHODS: Pub Med, Cochrane Library, EMBASE, and CNKI were systematically searched, and all studies involved MH were included. The closure rate of MH and the postoperative best-corrected visual acuity(BCVA) at 6 mo after the initial surgery were the primary measures. All statistical tests were performed in Review Manager 5.3.RESULTS: Five studies that included 151 eyes of 151 patients were finally included, all of which were retrospectively comparative studies. Between the pars plana vitrectomy(PPV) with ILM peeling surgery and the ILM insertion technique, the latter had significantly better efficacy with respect to the closure rate of MH(OR=21.32, 95%CI=7.25-62.67, P<0.001);However, regarding BCVA at 6 mo after the initial surgery in MH, there was no statistical significance between the groups(OR=-0.04, 95%CI=-0.22-0.14, P=0.66). In addition, regarding the rate of retinal reattachment after the initial surgery, the two different methods were not significantly different(OR=2.22, 95%CI=0.34-14.32, P=0.4).CONCLUSION: Both ILM peeling and ILM insertion technique could significantly improve anatomic outcomes of MH in high myopia with or without retinal detachment(RD), and anatomic outcomes are more effective. However, there is no statistical significance in BCVA at 6 mo after the initial surgery in MH, or in the rate of retinal reattachment after the first surgery, between the two methods. 展开更多
关键词 macular hole high myopia best-corrected visual acuity retinal attachment META-ANALYSIS
下载PDF
AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia:one-year follow-up results 被引量:2
20
作者 Rui-Bo Yang Shao-Zhen Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期360-365,共6页
AIM: To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults. METHODS: In this pros... AIM: To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults. METHODS: In this prospective study performed in Tianjin Medical University Eye Center & College of Optometry, Tianjin, China, 25 eyes of 13 patients were implanted with AcrySof phakic angle-supported IOLs and followed for 1 year postoperatively. Preoperative manifest refractive sphere was (-12.08 +/- 2.44) diopters (D) and cylinder was (-1.35 +/- 0.62)D. Visual acuity, predictability and stability of manifest refraction spherical equivalent (MRSE), adverse events, and endothelial cell density were analyzed during 1-year of follow-up. RESULTS: After 1 year of follow-up, no eyes lost 1 line (best spectacle-corrected visual acuity)BSCVA; an uncorrected visual acuity (UCVA) of 20/20 or better was achieved in 60% of eyes; 100% had an UCVA of 20/40 or better; a BSCVA of 20/30 or better was achieved by 100% of eyes; 84% had a BSCVA of 20/20 or better. The overall mean percentage change in endothelial cell density 1 year after surgery was (-0.27 +/- 3.60)%. Two eyes (8%) had increased intraocular pressure (IOP) on the day of surgery. No pupil ovalization, pupillary block, or retinal detachment events were observed. CONCLUSION: After 1 year of follow-up, the implantation of AcrySof phakic angle-supported IOL is proved to be safe, effective and predictable with minimal complications in patients with high-to-extremely high myopia. Due to the limitation of visiting time, long-term of clinical investigation is necessary to verify the safety and efficacy of this IOL. 展开更多
关键词 phakic eye lens INTRAOCULAR high myopia foldable angle-supported
下载PDF
上一页 1 2 97 下一页 到第
使用帮助 返回顶部