Microwave-assisted extraction(MAE)was used for extraction of effective components of sarcandra glabra(Thunb.),and then chromatographic fingerprint of sarcandra glabra(Thunb.)was studied by high performance liquid chro...Microwave-assisted extraction(MAE)was used for extraction of effective components of sarcandra glabra(Thunb.),and then chromatographic fingerprint of sarcandra glabra(Thunb.)was studied by high performance liquid chromatography/diode array detector(HPLC/DAD).The conditions of MAE were optimized by an orthogonal experiment,and then the authentication and validation of the chromatographic fingerprint were conducted.Nine peaks were identified as common peaks in the fingerprint chromatograms,and isofraxidin was considered as a reference compound and quantified.Relative standard deviations of retention time and peak area of each component were less than 3% and 8%,respectively.Similarity and difference analysis were conducted by use of PCA and relation coefficient.Twenty batches of sarcandra glabra(Thunb.)samples from two different producing areas could be classified into two different groups in the PCA model.The results showed that MAE-HPLC/DAD method was simple,efficient and stable for the study of complex chromatographic fingerprint of sarcandra glabra(Thunb.),which could provide more reliable and precise information for quality evaluation.展开更多
A high-performance liquid chromatographic method was applied to the determination of stachydrine hydrochloride concentration in TJF granule (Chinese name: Tiao-Jing-Fang), using a mobile phase of methanol-acetonitrile...A high-performance liquid chromatographic method was applied to the determination of stachydrine hydrochloride concentration in TJF granule (Chinese name: Tiao-Jing-Fang), using a mobile phase of methanol-acetonitrile (50:50, v/v) by the Agilent Kromasi NH2 column (250 mm × 4.6 mm, 5 μm, S/N: 22N25110). Detection wavelength was 201 nm. The result revealed good linearity of stachydrine hydrochloride and was obtained within the range of 0.20 - 1.98 μg/mL (R = 0.9995). The average recovery was 97.01%;the relative standard deviation (RSD) was 0.19%. To the best of our knowledge, this is the first report dedicated to the determination of stachydrine hydrochloride by the evaporative light scattering detector-high-performance liquid chromatographic (ELSD-HPLC) method.展开更多
基金supported the National Natural Science Foundation of China(Nos.20375050 and 20905080)National Key Technologies R&D Program of the 11th-five-year Plan(No.2006BAK03A08)Guangdong Provincial Department of Science and Technology(No.2009B010900021)
文摘Microwave-assisted extraction(MAE)was used for extraction of effective components of sarcandra glabra(Thunb.),and then chromatographic fingerprint of sarcandra glabra(Thunb.)was studied by high performance liquid chromatography/diode array detector(HPLC/DAD).The conditions of MAE were optimized by an orthogonal experiment,and then the authentication and validation of the chromatographic fingerprint were conducted.Nine peaks were identified as common peaks in the fingerprint chromatograms,and isofraxidin was considered as a reference compound and quantified.Relative standard deviations of retention time and peak area of each component were less than 3% and 8%,respectively.Similarity and difference analysis were conducted by use of PCA and relation coefficient.Twenty batches of sarcandra glabra(Thunb.)samples from two different producing areas could be classified into two different groups in the PCA model.The results showed that MAE-HPLC/DAD method was simple,efficient and stable for the study of complex chromatographic fingerprint of sarcandra glabra(Thunb.),which could provide more reliable and precise information for quality evaluation.
文摘A high-performance liquid chromatographic method was applied to the determination of stachydrine hydrochloride concentration in TJF granule (Chinese name: Tiao-Jing-Fang), using a mobile phase of methanol-acetonitrile (50:50, v/v) by the Agilent Kromasi NH2 column (250 mm × 4.6 mm, 5 μm, S/N: 22N25110). Detection wavelength was 201 nm. The result revealed good linearity of stachydrine hydrochloride and was obtained within the range of 0.20 - 1.98 μg/mL (R = 0.9995). The average recovery was 97.01%;the relative standard deviation (RSD) was 0.19%. To the best of our knowledge, this is the first report dedicated to the determination of stachydrine hydrochloride by the evaporative light scattering detector-high-performance liquid chromatographic (ELSD-HPLC) method.