●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria...●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.展开更多
Background: A number of meningeal neoplastic lesions may radiologically and clinically simulate meningioma, include hemangiopericytomas, solitary fibrous tumors, schwannomas, hematolymphoid lesions, metastases, and ot...Background: A number of meningeal neoplastic lesions may radiologically and clinically simulate meningioma, include hemangiopericytomas, solitary fibrous tumors, schwannomas, hematolymphoid lesions, metastases, and others very rarely, also may clinically mimic meningiomas. Case Description: We present the case of A 28-year-old male patient, with no notable medical history, who presented with worsening headaches for 3 months, imbalance, and visual deficits, An initial MRI revealed extra-axial lesion involving the right Parieto-occipital, The tumor was hypointense on T1-weighted MR images, hyperintense signals on T2-weightedMR images, and heterogeneously enhanced suggestive of a meningioma, total resection was achieved, and the histopathological analysis confirmed the diagnosis of an angioblastic meningioma. However, 15 months later, the patient presented with the same initial visual complaints. A subsequent MRI showed lesion recurrence, leading to a second surgical intervention. The histopathological analysis confirmed the diagnosis of an anaplastic xanthoastrocytoma. Conclusion: This represents an unusual location for an anaplastic pleomorphic xanthoastrocytoma, which should broaden the differential diagnosis of extra-axial lesions.展开更多
An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of ...An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures.展开更多
AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHOD...AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan.展开更多
AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were include...AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed.展开更多
The experimental investigation of axial-flow pump has been rapidly developed to meet the needs of South-to-North Water Diversion Project of China. Owing to the boundary conditions of hub, blade tip clearance, much of ...The experimental investigation of axial-flow pump has been rapidly developed to meet the needs of South-to-North Water Diversion Project of China. Owing to the boundary conditions of hub, blade tip clearance, much of the physical phenomena and laws involved in this complex flow field can't be fully determined. The flow characteristics of the high efficiency axial-flow pump have been simulated by RNG k-e turbulence model and SIMPLEC arithmetic based on FLUENT software. Numerical results indicate that the data from the prediction show agreement with the experimental results, static pressure on pressure side of blades increases slightly at circumferential direction with radius increasing, and keep almost constant at the same radial while increasing gradually from inlet to exit on the suction side along flow direction at design conditions. The static pressure, total pressure and velocity at inlet, impeller outlet and vane outlet were measured by a five-hole probe, and a contrastive experiment was done to investigate the influence of hub leakage. The experimental results show that inlet flow is almost axial and the prerotation is very small at various conditions. The meridional velocity and circulation distribution are almost identical at impeller outlet at design conditions due to steady flow and high efficiency. The residual circulation exits at downstream of the guide vane, and the circumferential velocity component increases linearly from hub to tip at small flow rate conditions. Hub leakage in adjustable blades results in the decrease of the meridional velocity and circulation at blade exit near hub. The results of numerical simulation and experiments supply important flow structure information for the high-efficiency axial-flow pump.展开更多
The seismic ductility of reinforced very-high-strength-concrete (VHSC) short columns was studied by combinatively applying axial load and low cyclic lateral load on specimens to simulate seismic impact. Twelve specime...The seismic ductility of reinforced very-high-strength-concrete (VHSC) short columns was studied by combinatively applying axial load and low cyclic lateral load on specimens to simulate seismic impact. Twelve specimens with concrete compressive strength ranging from 95.6 MPa to 118.6 MPa and a shear-span ratio of 2.0 were tested for shear failure pattern and fear force-displacement hysteretic responses. Combinative application of axial load and low cyclic lateral load to VHSC short columns incurs shear failure. The displacement ductility is much smaller when the axial load ratio is larger;whereas a larger stirrup ratio is accompanied with a better displacement ductility. The relationship of displacement ductility factor, μ?, with stirrup characteristic value, λv, and test axial load ratio, nt, is μ?=(1+8λv)/(0.33+nt). By this relationship and relevant codes for aseismatic design, the axial load ratio limits for aseismatic design of reinforced VHSC (C95 to C100) short columns for frame construction are respectively 0.5, 0.6, and 0.7 for seismic classes I, II, and Ⅲ;corresponding minimum characteristic values of stirrups are calculated according to the required characteristic values of at least 1.273 times of experimental results. These data are very useful to aseismatic engineering.展开更多
AIM:To evaluate the influence of age and axial length(AL) on the position of the fovea in patients with high myopia(HM).METHODS:In this prospective study,96 patients(186 eyes) with HM were consecutively recrui...AIM:To evaluate the influence of age and axial length(AL) on the position of the fovea in patients with high myopia(HM).METHODS:In this prospective study,96 patients(186 eyes) with HM were consecutively recruited from the Third Affiliated Hospital of Nanchang University.DRI-OCT Atlantis,fundus imaging,and IOL Master were used in this study.Three indices were measured:the distance between the fovea and the optic nerve head(ONH) center(DFO),the vertical distance between the fovea and the horizontal line pass of the ONH center(VDFO),and the horizontal distance between the fovea and the vertical line pass of the ONH center(HDFO).These measurements were used to analyze the effects of different age groups(A1,A2,A3 groups) and AL(AL1,AL2,AL3,AL4 groups) on these indices.RESULTS:The results showed that there was no statistical significance in DFO among the age and AL groups(F=0.46,0.37;P=0.62,0.76,respectively).In HDFO,there was also no statistical significance among the age and AL groups(F=0.10,0.48;P=0.90,0.69,respectively).In VDFO,however,the difference in the age and AL groups was statistically significant(F=3.21,3.12;P=0.04,0.02,respectively).Thus,VDFO were correlated with age and AL(r=0.21,0.23,all P〈0.01),while HDFO and DFO were not correlated with age and AL(r=0.30,P〉0.05).CONCLUSION:In high myopia,the foveal position changes mainly in the vertical direction along with factors of age and AL.展开更多
The real-time measurement principle of high rotational projectile's angular velocity based on 2-axis acceleration sensor and the axial acceleration measurement error caused by the installation error are discussed.The...The real-time measurement principle of high rotational projectile's angular velocity based on 2-axis acceleration sensor and the axial acceleration measurement error caused by the installation error are discussed.The 2-axis acceleration sensor is applied to measure the high rotational projectile's angular velocity and the measurement value of axial acceleration,the axial acceleration of the high rotational projectile equals the measurement value of axial acceleration subtracting the centrifugal acceleration component,so that the high-accuracy real-time measurement of axial acceleration is realized.The memory test has confirmed the strike tally of the theoretical analysis and the test result.The measurement technique can satisfy the high-accuracy measurement of the high rotational projectile axial acceleration in the self-determination course correction fuze projectile.展开更多
文摘●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.
文摘Background: A number of meningeal neoplastic lesions may radiologically and clinically simulate meningioma, include hemangiopericytomas, solitary fibrous tumors, schwannomas, hematolymphoid lesions, metastases, and others very rarely, also may clinically mimic meningiomas. Case Description: We present the case of A 28-year-old male patient, with no notable medical history, who presented with worsening headaches for 3 months, imbalance, and visual deficits, An initial MRI revealed extra-axial lesion involving the right Parieto-occipital, The tumor was hypointense on T1-weighted MR images, hyperintense signals on T2-weightedMR images, and heterogeneously enhanced suggestive of a meningioma, total resection was achieved, and the histopathological analysis confirmed the diagnosis of an angioblastic meningioma. However, 15 months later, the patient presented with the same initial visual complaints. A subsequent MRI showed lesion recurrence, leading to a second surgical intervention. The histopathological analysis confirmed the diagnosis of an anaplastic xanthoastrocytoma. Conclusion: This represents an unusual location for an anaplastic pleomorphic xanthoastrocytoma, which should broaden the differential diagnosis of extra-axial lesions.
基金Project(51078294)supported by the National Natural Science Foundation of ChinaProject(201101411100025)supported by the Doctoral Fund of Ministry of Education of China
文摘An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures.
基金Supported by National Key Basic Research Program of China(973 Program,No.2013CB967000)National Natural Science Foundation of China(No.81271052)
文摘AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan.
文摘AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed.
基金supported by National Hi-tech Research and Development Program of China (863 Program, Grant No. 2007AA05Z207)National Science and Technology Support Scheme of China (Grant No. 2008BAF34B10)Jiangsu Provincial Graduate Student Innovation Foundation of China (Grant No. CX08B_064Z)
文摘The experimental investigation of axial-flow pump has been rapidly developed to meet the needs of South-to-North Water Diversion Project of China. Owing to the boundary conditions of hub, blade tip clearance, much of the physical phenomena and laws involved in this complex flow field can't be fully determined. The flow characteristics of the high efficiency axial-flow pump have been simulated by RNG k-e turbulence model and SIMPLEC arithmetic based on FLUENT software. Numerical results indicate that the data from the prediction show agreement with the experimental results, static pressure on pressure side of blades increases slightly at circumferential direction with radius increasing, and keep almost constant at the same radial while increasing gradually from inlet to exit on the suction side along flow direction at design conditions. The static pressure, total pressure and velocity at inlet, impeller outlet and vane outlet were measured by a five-hole probe, and a contrastive experiment was done to investigate the influence of hub leakage. The experimental results show that inlet flow is almost axial and the prerotation is very small at various conditions. The meridional velocity and circulation distribution are almost identical at impeller outlet at design conditions due to steady flow and high efficiency. The residual circulation exits at downstream of the guide vane, and the circumferential velocity component increases linearly from hub to tip at small flow rate conditions. Hub leakage in adjustable blades results in the decrease of the meridional velocity and circulation at blade exit near hub. The results of numerical simulation and experiments supply important flow structure information for the high-efficiency axial-flow pump.
基金the key project of the National Natural Science Foundation of China (No.50438010)
文摘The seismic ductility of reinforced very-high-strength-concrete (VHSC) short columns was studied by combinatively applying axial load and low cyclic lateral load on specimens to simulate seismic impact. Twelve specimens with concrete compressive strength ranging from 95.6 MPa to 118.6 MPa and a shear-span ratio of 2.0 were tested for shear failure pattern and fear force-displacement hysteretic responses. Combinative application of axial load and low cyclic lateral load to VHSC short columns incurs shear failure. The displacement ductility is much smaller when the axial load ratio is larger;whereas a larger stirrup ratio is accompanied with a better displacement ductility. The relationship of displacement ductility factor, μ?, with stirrup characteristic value, λv, and test axial load ratio, nt, is μ?=(1+8λv)/(0.33+nt). By this relationship and relevant codes for aseismatic design, the axial load ratio limits for aseismatic design of reinforced VHSC (C95 to C100) short columns for frame construction are respectively 0.5, 0.6, and 0.7 for seismic classes I, II, and Ⅲ;corresponding minimum characteristic values of stirrups are calculated according to the required characteristic values of at least 1.273 times of experimental results. These data are very useful to aseismatic engineering.
基金Supported by the Research and Development Project of Science and Technology of the Jiangxi Province(No.20171BBG70100)the Ophthalmic Innovation Project of Nanchang City(No.2016114)
文摘AIM:To evaluate the influence of age and axial length(AL) on the position of the fovea in patients with high myopia(HM).METHODS:In this prospective study,96 patients(186 eyes) with HM were consecutively recruited from the Third Affiliated Hospital of Nanchang University.DRI-OCT Atlantis,fundus imaging,and IOL Master were used in this study.Three indices were measured:the distance between the fovea and the optic nerve head(ONH) center(DFO),the vertical distance between the fovea and the horizontal line pass of the ONH center(VDFO),and the horizontal distance between the fovea and the vertical line pass of the ONH center(HDFO).These measurements were used to analyze the effects of different age groups(A1,A2,A3 groups) and AL(AL1,AL2,AL3,AL4 groups) on these indices.RESULTS:The results showed that there was no statistical significance in DFO among the age and AL groups(F=0.46,0.37;P=0.62,0.76,respectively).In HDFO,there was also no statistical significance among the age and AL groups(F=0.10,0.48;P=0.90,0.69,respectively).In VDFO,however,the difference in the age and AL groups was statistically significant(F=3.21,3.12;P=0.04,0.02,respectively).Thus,VDFO were correlated with age and AL(r=0.21,0.23,all P〈0.01),while HDFO and DFO were not correlated with age and AL(r=0.30,P〉0.05).CONCLUSION:In high myopia,the foveal position changes mainly in the vertical direction along with factors of age and AL.
基金Supported by the National Natural Science Foundation of China(10772029)
文摘The real-time measurement principle of high rotational projectile's angular velocity based on 2-axis acceleration sensor and the axial acceleration measurement error caused by the installation error are discussed.The 2-axis acceleration sensor is applied to measure the high rotational projectile's angular velocity and the measurement value of axial acceleration,the axial acceleration of the high rotational projectile equals the measurement value of axial acceleration subtracting the centrifugal acceleration component,so that the high-accuracy real-time measurement of axial acceleration is realized.The memory test has confirmed the strike tally of the theoretical analysis and the test result.The measurement technique can satisfy the high-accuracy measurement of the high rotational projectile axial acceleration in the self-determination course correction fuze projectile.