期刊文献+
共找到71篇文章
< 1 2 4 >
每页显示 20 50 100
Effectiveness of high intensity interval training on cardiorespiratory fitness and endothelial function in type 2 diabetes:A systematic review
1
作者 Christos Kourek Eleftherios Karatzanos +4 位作者 Vasiliki Raidou Ourania Papazachou Anastassios Philippou Serafim Nanas Stavros Dimopoulos 《World Journal of Cardiology》 2023年第4期184-199,共16页
BACKGROUND Type 2 diabetes mellitus(T2DM)is a chronic metabolic syndrome characterized by insulin resistance and hyperglycemia that may lead to endothelial dysfunction,reduced functional capacity and exercise intolera... BACKGROUND Type 2 diabetes mellitus(T2DM)is a chronic metabolic syndrome characterized by insulin resistance and hyperglycemia that may lead to endothelial dysfunction,reduced functional capacity and exercise intolerance.Regular aerobic exercise has been promoted as the most beneficial non-pharmacological treatment of cardiovascular diseases.High intensity interval training(HIIT)seems to be superior than moderate-intensity continuous training(MICT)in cardiovascular diseases by improving brachial artery flow-mediated dilation(FMD)and cardiorespiratory fitness to a greater extent.However,the beneficial effects of HIIT in patients with T2DM still remain under investigation and number of studies is limited.AIM To evaluate the effectiveness of high intensity interval training on cardiorespiratory fitness and endothelial function in patients with T2DM.METHODS We performed a search on PubMed,PEDro and CINAHL databases,selecting papers published between December 2012 and December 2022 and identified published randomized controlled trials(RCTs)in the English language that included community or outpatient exercise training programs in patients with T2DM.RCTs were assessed for methodological rigor and risk of bias via the Physiotherapy Evidence Database(PEDro).The primary outcome was peak VO_(2 ) and the secondary outcome was endothelial function assessed either by FMD or other indices of microcirculation.RESULTS Twelve studies were included in our systematic review.The 12 RCTs resulted in 661 participants in total.HIIT was performed in 310 patients(46.8%),MICT to 271 and the rest 80 belonged to the control group.Peak VO_(2 ) increased in 10 out of 12 studies after HIIT.Ten studies compared HIIT with other exercise regimens(MICT or strength endurance)and 4 of them demonstrated additional beneficial effects of HIIT over MICT or other exercise regimens.Moreover,4 studies explored the effects of HIIT on endothelial function and FMD in T2DM patients.In 2 of them,HIIT further improved endothelial function compared to MICT and/or the control group while in the rest 2 studies no differences between HIIT and MICT were observed.CONCLUSION Regular aerobic exercise training has beneficial effects on cardiorespiratory fitness and endothelial function in T2DM patients.HIIT may be superior by improving these parameters to a greater extent than MICT. 展开更多
关键词 Type 2 diabetes mellitus EXERCISE high intensity interval training Cardiorespiratory fitness Peak VO_(2) Endothelial function
下载PDF
Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors 被引量:14
2
作者 Jian-Jun Li Guo-Liang Xu +4 位作者 Mo-Fa Gu Guang-Yu Luo Zhang Rong Pei-Hong Wu Jian-Chuan Xia 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第19期2747-2751,共5页
AIM: To analyze the local and systemic complications of high intensity focused ultrasound (HIFU) for patients with recurrent and metastatic abdominal tumors. METHODS: From Aug 2001 to Aug 2004, 17 patients with re... AIM: To analyze the local and systemic complications of high intensity focused ultrasound (HIFU) for patients with recurrent and metastatic abdominal tumors. METHODS: From Aug 2001 to Aug 2004, 17 patients with recurrent and metastatic abdominal tumors were enrolled in this study. Real-time sonography was taken, and vital signs, liver and kidney function, skin burns, local reactions, and systemic effects were observed and recored before, during, and after HIFU. CT and MR/were also taken before and after HIFU. RESULTS: All 17 patients had skin burns and pain in the treatment region; the next common complication was neurapraxia of the stomach and intestines to variable degrees. The other local and systemic complications were relatively rare. Severe complications were present in two patients; one developed a superior mesenteric artery infarction resulting in necrosis of the entire small intestines, and the other one suffered from a perforation in terminal ileum due to HIFU treatment. CONCLUSION: Although HIFU is a one of noninvasive treatments for the recurrent and metastatic abdominal tumors, there are still some common and severe complications which need serious consideration. 展开更多
关键词 Abdominal cavity RECURRENT METASTATIC TUMOR high intensity focused ultrasound Ultrasonic therapy
下载PDF
High intensity focused ultrasound: A noninvasive therapy for locally advanced pancreatic cancer 被引量:14
3
作者 Feng Wu 《World Journal of Gastroenterology》 SCIE CAS 2014年第44期16480-16488,共9页
The noninvasive ablation of pancreatic cancer with high intensity focused ultrasound(HIFU) energy is received increasingly widespread interest. With rapidly temperature rise to cytotoxic levels within the focal volume... The noninvasive ablation of pancreatic cancer with high intensity focused ultrasound(HIFU) energy is received increasingly widespread interest. With rapidly temperature rise to cytotoxic levels within the focal volume of ultrasound beams, HIFU can selectively ablate a targeted lesion of the pancreas without any damage to surrounding or overlying tissues. Preliminary studies suggest that this approach is technical safe and feasible, and can be used alone or in combination with systemic chemotherapy for the treatment of patients with locally advanced pancreatic cancer. It can effectively alleviate cancer-related abdominal pain, and may confer an additional survival benefit with few significant complications. This review provides a brief overview of HIFU, describes current clinical applications, summarizes characteristics of continuous and pulsed HIFU, and discusses future applications and challenges in the treatment of pancreatic cancer. 展开更多
关键词 Pancreatic cancer high intensity focused ultrasound Focused ultrasound surgery Thermal ablation HYPERTHERMIA Therapeutic ultrasound
下载PDF
Effect of high intensity ultrasound on the allergenicity of shrimp 被引量:13
4
作者 LI Zhen-xing LIN Hong +1 位作者 CAO Li-min JAMEEL Khalid 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2006年第4期251-256,共6页
The tropomyosin fraction of shrimp proteins is potentially responsible for allergic reaction in individuals with genetic predisposition to allergy. However, there are no efficient and safe methods to reduce its allerg... The tropomyosin fraction of shrimp proteins is potentially responsible for allergic reaction in individuals with genetic predisposition to allergy. However, there are no efficient and safe methods to reduce its allergenicity. High intensity ultrasound is known to change the structure of proteins. This study is aimed at assessing high intensity ultmsound's effect on the allergenicity of shrimp allergen. Shrimp and purified shrimp allergen were treated with high intensity ultrasound for 30-180 min. Extracts of treated samples were analyzed by enzyme-linked immunosorbent assay (ELISA) with pool serum of shrimp allergy patients and polyclonal anti-allergen antibodies and by immunoblotting after polyacrylamide gel electrophoresis. Shrimp treated with high intensity ultrasound showed a decrease in allergenicity measured with ELISA. A linear relationship between the immune response induced by treated shrimp allergen and the applied treatment time was observed. The decrease in allergenicity was confirmed by immunoblot assays with shrimp allergic patients serum. Allergenicity of shrimp allergen extracted from treated shrimp was higher than that of purified shrimp allergen with the same treatment time. Gel-filtration HPLC was applied for analysis of shrimp allergen after treatment with high intensity ultrasound. Some fractions were appeared with increasing treatment time. The results suggested that high intensity ultrasound could be used to reduce the allergenicity of shrimp. 展开更多
关键词 SHRIMP ALLERGEN ALLERGENICITY high intensity ultrasound
下载PDF
Spatial correlation of the high intensity zone in deep-water acoustic field 被引量:8
5
作者 李鋆 李整林 任云 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第12期69-76,共8页
The spatial correlations of acoustic field have important implications for underwater target detection and other ap- plications in deep water. In this paper, the spatial correlations of the high intensity zone in the ... The spatial correlations of acoustic field have important implications for underwater target detection and other ap- plications in deep water. In this paper, the spatial correlations of the high intensity zone in the deep-water acoustic field are investigated by using the experimental data obtained in the South China Sea. The experimental results show that the structures of the spatial correlation coefficient at different ranges and depths are similar to the transmission loss structure in deep water. The main reason for this phenomenon is analyzed by combining the normal mode theory with the ray theory. It is shown that the received signals in the high intensity zone mainly include one or two main pulses which are contributed by the interference of a group of waterbome modes with similar phases. The horizontal-longitudinal correlations at the same receiver depth but in different high intensity zones are analyzed. At some positions, more pulses are received in the arrival structure of the signal due to bottom reflection and the horizontal-longitudinal correlation coefficient decreases accordingly. The multi-path arrival structure of receiving signal becomes more complex with increasing receiver depth. 展开更多
关键词 spatial correlations deep water high intensity zone normal mode
下载PDF
Non-thermal ablation of rabbit liver VX2 tumor by pulsed high intensity focused ultrasound with ultrasound contrast agent:Pathological characteristics 被引量:6
6
作者 Cheng-Wen Zhou Fa-Qi Li +3 位作者 Yan Qin Chun-Mei Liu Xiao-Lin Zheng Zhi-Biao Wang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第43期6743-6747,共5页
AIM: To investigate the pathological characteristics of non-thermal damage induced by pulsed high intensity focused ultrasound (PHIFU) combined with ultrasound contrast agent (UCA), SonoVue (Bracco SpA, Milan, I... AIM: To investigate the pathological characteristics of non-thermal damage induced by pulsed high intensity focused ultrasound (PHIFU) combined with ultrasound contrast agent (UCA), SonoVue (Bracco SpA, Milan, Italy) in rabbit liver VX2 tumor. METHODS: Liver VX2 tumor models were established in 20 rabbits, which were divided randomly into PHIFU combined with ultrasound contrast agent group (PHIFU + UCA group) and sham group. In the PHIFU + UCA group, 0.2 mL of SonoVue was injected intravenously into the tumor, followed by ultrasound exposure of Isp 5900 W/cm^2. The rabbits were sacrificed one day after ultrasound exposure. Specimens of the exposed tumor tissues were obtained and observed pathologically under light microscope and transmission electron microscope. The remaining tumor tissues were sent for 2,3,5-Triphenyltetrazolium chloride (TTC) staining. RESULTS: Before Trc staining, tumor tissues in both the sham and the PHIFU + UCA groups resembled gray fish meat, After TIC staining, the tumor tissues were uniformly stained red, with a clear boundary between tumor tissue and normal tissue, Histological examination showed signs of tumor cell injury in PHIFU + UCA group, with cytoplasmic vacuoles of various sizes, chromatin margination and karyopyknosis. Electron microscopic examination revealed tumor cell volume reduction, karyopyknosis, chromatin margination, intercellular space widening, the presence of high electro'n-density apoptotic bodies and vacuoles in cytoplasm. CONCLUSION: The non-thermal effects of PHIFU combined with UCA can be used to ablate rabbit liver VX2 tumors. 展开更多
关键词 Pulsed high intensity focused ultrasound Ultrasound contrast agent Non-thermal effects Rabbitliver VX2 tumors HISTOPATHOLOGY
下载PDF
Mechanism and Kinetic Model of In-situ TiB_2/7055Al Nanocomposites Synthesized under High Intensity Ultrasonic Field 被引量:5
7
作者 陈登斌 赵玉涛 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第5期920-925,共6页
In-situ TiB2/7055Al nanocomposites are fabricated by in situ melt chemical reaction from 7055Al-K2TiF6-KBF4 system under high intensity ultrasonic field,and the mechanism and kinetic model of in-situ melt chemical rea... In-situ TiB2/7055Al nanocomposites are fabricated by in situ melt chemical reaction from 7055Al-K2TiF6-KBF4 system under high intensity ultrasonic field,and the mechanism and kinetic model of in-situ melt chemical reaction are investigated.X-ray diffraction (XRD) and scanning electron microscope (SEM) analyses indicate that the sizes of in-situ TiB2 nanoparticles are in the range of 80-120 nm.The results of ice-water quenched samples show that the whole process contains four stages,and the overall in-situ reaction time is 10 minutes.The in situ synthesis process is controlled mainly by chemical reaction in earlier stage (former 3 minutes),and by the particulate diffusing in later stage.The mechanism of key reaction between Al3Ti and AlB2 under high intensity ultrasonic in the 7055Al-K2TiF6-KBF4 system is the reaction-diffusion-crack-rediffusion.Furthermore,the reactive kinetic models in 7055Al-K2TiF6-KBF4 system are established. 展开更多
关键词 in-situ nanocomposites high intensity ultrasonic field reactive mechanism kinetic model
下载PDF
Recovering limonite from Australia iron ores by flocculation-high intensity magnetic separation 被引量:5
8
作者 罗立群 张泾生 余永富 《Journal of Central South University of Technology》 EI 2005年第6期682-687,共6页
Successful recovery of limonite from iron fines was achieved by using flocculation-high intensity magnetic separation (FIMS) and adding hydrolyzed and causticized flocculants according to the characteristic of iron ... Successful recovery of limonite from iron fines was achieved by using flocculation-high intensity magnetic separation (FIMS) and adding hydrolyzed and causticized flocculants according to the characteristic of iron fines. The separation results of the three iron samples are as follows: iron grade 66.77%- 67.98% and the recovery of iron 69.26%-70.70% by the FIMS process with flocculants. The comparative results show that under the same separation conditions the F1MS process can effectively increase the recovery of iron by 10. 97%- 15.73%. The flowsheet results confirm the reliability of the process in a SHP high intensity magnetic separator. The concentrate product can he used as raw materials for direct reduction iron-smelting. The hydrolyzed and causticized flocculants can selectively flocculate fine feebly-magnetic iron mineral particles to increase their apparent separation sizes. The larger the separation size, the stronger the magnetic force. By comparing the separation results of the three samples it is found that among the three samples the higher the limonite content, the better the separation result. This means that the separation result relates closely to the flocculation process and the adding pattern of the flocculant. 展开更多
关键词 Australia iron ores FLOCCULATION high intensity magnetic separation LIMONITE
下载PDF
Identification of denatured and normal biological tissues based on compressed sensing and refined composite multi-scale fuzzy entropy during high intensity focused ultrasound treatment 被引量:4
9
作者 Shang-Qu Yan Han Zhang +2 位作者 Bei Liu Hao Tang Sheng-You Qian 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期601-607,共7页
In high intensity focused ultrasound(HIFU)treatment,it is crucial to accurately identify denatured and normal biological tissues.In this paper,a novel method based on compressed sensing(CS)and refined composite multi-... In high intensity focused ultrasound(HIFU)treatment,it is crucial to accurately identify denatured and normal biological tissues.In this paper,a novel method based on compressed sensing(CS)and refined composite multi-scale fuzzy entropy(RCMFE)is proposed.First,CS is used to denoise the HIFU echo signals.Then the multi-scale fuzzy entropy(MFE)and RCMFE of the denoised HIFU echo signals are calculated.This study analyzed 90 cases of HIFU echo signals,including 45 cases in normal status and 45 cases in denatured status,and the results show that although both MFE and RCMFE can be used to identify denatured tissues,the intra-class distance of RCMFE on each scale factor is smaller than MFE,and the inter-class distance is larger than MFE.Compared with MFE,RCMFE can calculate the complexity of the signal more accurately and improve the stability,compactness,and separability.When RCMFE is selected as the characteristic parameter,the RCMFE difference between denatured and normal biological tissues is more evident than that of MFE,which helps doctors evaluate the treatment effect more accurately.When the scale factor is selected as 16,the best distinguishing effect can be obtained. 展开更多
关键词 compressed sensing high intensity focused ultrasound(HIFU)echo signal multi-scale fuzzy entropy refined composite multi-scale fuzzy entropy
下载PDF
Femoral neck stress fracture and medial tibial stress syndrome following high intensity interval training: A case report and review of literature 被引量:1
10
作者 Dawn Suwanie Tan Fiona Millicent Cheung +1 位作者 Dekai Ng Tin Lung Alan Cheung 《World Journal of Clinical Cases》 SCIE 2022年第23期8323-8329,共7页
BACKGROUND Femoral and tibial stress injuries are commonly found in long distance running athletes.Stress fractures have rarely been reported in athletes performing high intensity interval training(HIIT)exercise.The o... BACKGROUND Femoral and tibial stress injuries are commonly found in long distance running athletes.Stress fractures have rarely been reported in athletes performing high intensity interval training(HIIT)exercise.The objective of this study was to report a case of a patient who presented with medial tibial stress syndrome and femoral neck stress fracture after performing HIIT exercises.CASE SUMMARY A 26 year old female presented with bilateral medial tibial pain.She had been performing HIIT exercise for 45 min,five times weekly,for a seven month period.Her tibial pain was gradual in onset,and was now severe and worse on exercise,despite six weeks of rest.Magnetic resonance imaging(MRI)revealed bilateral medial tibial stress syndrome.As she was taking norethisterone for birth control,a dual energy X-ray absorbitometry scan was performed which demonstrated normal bone mineral density of her lumbar spine and femoral neck.She was managed conservatively with analgesia and physiotherapy,but continued to exercise against medical advice.She presented again six months later with severe right hip pain.MRI of her right hip demonstrated an incomplete stress fracture of her subtrochanteric region.Her symptoms resolved with strict rest and physiotherapy.CONCLUSION HIIT may cause stress injury of the tibia and femur in young individuals. 展开更多
关键词 high intensity interval training Medial tibial stress syndrome Femoral neck stress fracture EXERCISE FRACTURE Case report
下载PDF
Role of acoustic interface layer during high intensity focused ultrasound therapeutics 被引量:1
11
作者 Li Quanyi Fu Liyuan Qin Yan Li Faqi Wang Zhibiao 《Journal of Medical Colleges of PLA(China)》 CAS 2008年第4期223-227,共5页
After interface layer was simulated by the magnetic nano-particles in the egg white phantom, high intensity focused ultrasound (HIFU) at the same dosage was introduced to radiate the phantom in different depths to b... After interface layer was simulated by the magnetic nano-particles in the egg white phantom, high intensity focused ultrasound (HIFU) at the same dosage was introduced to radiate the phantom in different depths to blow the acoustic interface layer to mimic "point" exposure. The results showed that the volumes of biological focal region (BFR) were enlarged when the acoustic focal region (AFR) is close with interface layer. This meant that the magnetic nano-particles enhanced the therapeutic efficiency of HIFU. When the distance of the AFR from the interface layer was 10 mm, the size and shape of the BFR were similar with those of the control group, but a larger lesion at the interface, which was harmful for treatment, was observed. When the distance of the AFR to the interface layer increased to 30 mm, the size and shape of the BFR were also similar to those of the control group. When the thickness of the interface layer diminished, the utility of enhancement decreased. Continuous increase of the safe area for treatment and decrease of the utility of enhancement were observed along with the abatement of the thickness of the interface layer 展开更多
关键词 Magnetic nano-particles Interface layer Biological focal region high intensity focused ultrasound
下载PDF
Analgesic effect of high intensity focused ultrasound in patients with advanced pancreatic cancer
12
作者 Xinjin Tan Jian Chen +2 位作者 Li Ren Ruilu Lin Zailian Chen 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第8期385-388,共4页
Objective: The aim of this study was to evaluate the analgesic effect of high intensity focused ultrasound (HIFU) in patients with advanced pancreatic cancer. Methods: A total of 106 patients with advanced pancrea... Objective: The aim of this study was to evaluate the analgesic effect of high intensity focused ultrasound (HIFU) in patients with advanced pancreatic cancer. Methods: A total of 106 patients with advanced pancreatic cancer accompanied by abdominal pain were treated by HIFU. Pain intensities and quantities of morphine consumption before and after treatment were observed and compared. Results: The average pain intensities before treatment, and at d3, d7 after treatment were 5.80 ±2.14, 2.73 ± 2.68, 2.45 ± 2.43 respectively (P 〈 0.01). Fifty-nine cases (55.7%) got to extremely effective, and 29 cases (27.4%) effective. Total efficient rate was 83.0 %. The average quantities of morphine consumption before and after treatment in the patients with grade III pain were 114.9 ± 132.5 rag, 16.8 ± 39.7 mg each person everyday respectively (P 〈 0.01). Conclusion: HIFU can relieve pain suffered by patients with pancreatic cancer effectively. It is a new adjuvant treatment for pancreatic cancer pain. 展开更多
关键词 high intensity focused ultrasound pancreatic cancer PAIN
下载PDF
Novel Automotive High Intensity Discharge(HID) Lamps with Electronic Ballasts
13
作者 JIANG Xin WANG Fuzhong YUAN Shenlong 《Semiconductor Photonics and Technology》 CAS 2010年第1期57-61,共5页
A new scheme of automotive high intensity discharge(HID) lamps with electronic ballasts is proposed. The design of the proposed ballast and some experimental results are presented. The proposed scheme is consisted of ... A new scheme of automotive high intensity discharge(HID) lamps with electronic ballasts is proposed. The design of the proposed ballast and some experimental results are presented. The proposed scheme is consisted of the high frequency DC-DC converter and the low frequency DC-AC inverter. This system separates the input voltage of the ignitor from DC link voltage using auxiliary winding, then it could use the lower voltage rating power devices for HID lamp ballast system and reduce the size of HID lamp ballast. The proposed ballast controller using micro-controller unit(MCU) controls the frequency to operate the DC-DC converter in critical conduction mode, which reduces the noise of the circuit and improves the efficiency by 2%~4%. 展开更多
关键词 automotive high intensity discharge lamp BALLAST critical conduction mode microprogrammed control unit
下载PDF
High intensity focused ultrasound in combination with chemotherapy by the regime of PFC: a clinical study for advanced gastric carcinoma
14
作者 Qingxia Mu Yongqian Shu +2 位作者 Puwen Huang Kaihua Lu Rongsheng Wang 《Journal of Nanjing Medical University》 2005年第4期203-205,共3页
Objective: To evaluate the recent curative efficacy and security of High intensity focused ultrasound (HIFU) in combination with chemotherapy(PFC) in patients with advanced gastric carcinoma. Method: Sixty patie... Objective: To evaluate the recent curative efficacy and security of High intensity focused ultrasound (HIFU) in combination with chemotherapy(PFC) in patients with advanced gastric carcinoma. Method: Sixty patients with measurable advanced gastric carcinoma, proved pathologically, were divided into Group A and Group B. Group A: Patients were treated by HIFU(FEP-BY01) in combination with chemotherapy(PFC, paclitaxel, cisplatin and 5-fluorouracil). Group B: Patients were treated with the single regime of PFC. Results: All cases could be evaluated, ha group A, 5 patients achieved complete response, 17 patients achieved partial response,and a response rate was 73.3%. The stable disease(SD) and the inefficiency all were 13.3% (4/30) respectively, and msurvival time(MST) was 13.9 months. In group B, 2 patients achieved complete response, 14 patients achieved partial response, and a response rate was 53.3%. The stable disease(SD) was 23.3%(7/30). The inefficiency all were 23.3%(7/30) respectively, and median survival time was 9.6 months. There was significant difference between two groups MST( P 〈 0.05). Major toxicities included bone marrow depression, nausea, vomiting and alopecia, without significant differences between two groups( P 〉 0.05). Conclusion: This study shows that HIFU in combination with chemotherapy(PFC) was a new efficent and secure therapy for the patients with advanced gastric carcinoma. It was observed that the MST was prolonged. Prospective trials should be warranted to determine the result. 展开更多
关键词 PFC CHEMOTHERAPY HIFU(high intensity Focused Ultrasound) gastric carcinoma
下载PDF
The Comparison of the Effects of Two Types of High Intensity Interval Training (HILT) on Body Mass and Physiological Indexes in Inactive Female Students
15
作者 Sahar Avazpor Jamal Fazel Kalkhoran Hojat Allah Amini 《Journal of Sports Science》 2016年第4期219-225,共7页
The aim of this study was to compare the effects of two types of high intensity interval training (HIIT) on body mass and physiological indexes in inactive female students. 27 inactive female students (mean age 24.... The aim of this study was to compare the effects of two types of high intensity interval training (HIIT) on body mass and physiological indexes in inactive female students. 27 inactive female students (mean age 24.81 ±0.66 yr, height 162.09 ±0.67 cm, weight 59.41 ±0.33 kg) were voluntarily selected and randomly assigned to three groups (each group = 9 subjects) of high intensity interval training (type I), high intensity interval training (type 2) and control. HIIT (type 1) (8 seconds of sprint running and 12 seconds of active recovery) was performed for 4 weeks, 3 sessions per week, 6-9 min. per session with above 90% maxHR. HIlT (type 2) (40-m shuttle run test with maximum speed) was performed with above 90% max HR while the control group did not participate in any training. Data analysis with dependent t test showed that HIIT (type 1) and HIlT (type 2) significantly increased VO2max while they decreased fat percentage and BMI. The intergroup data were analyzed by one-way ANOVA at P 〈 0.05. The results showed a significant difference among HIlT (type 1), HIIT (type 2) and control groups in VO2max, BMI and fat percentage. 展开更多
关键词 high intensity Interval Training (HIIT) VO2MAX BMI WHR body fat percentage.
下载PDF
A fast emittance measurement unit for high intensity DC beam
16
作者 张艾霖 任海涛 +7 位作者 彭士香 张滔 徐源 张景丰 温佳美 武文斌 郭之虞 陈佳洱 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期446-449,共4页
A combined unit, which has the ability to measure the current and emittance of the high intensity direct current(DC)ion beam, is developed at Peking University(PKU). It is a multi-slit single-wire(MSSW)-type bea... A combined unit, which has the ability to measure the current and emittance of the high intensity direct current(DC)ion beam, is developed at Peking University(PKU). It is a multi-slit single-wire(MSSW)-type beam emittance meter combined with a water-cooled Faraday Cup, named high intensity beam emittance measurement unit-6(HIBEMU-6). It takes about 15 seconds to complete one measurement of the beam current and its emittance. The emittance of a 50-mA@50-kV DC proton beam is measured. 展开更多
关键词 emittance measurement high intensity DC beam MSSW
下载PDF
Fine particle aggregating and flotation behavior induced by high intensity conditioning of a CO_2 saturation slurry 被引量:5
17
作者 SUN Wei DENG Mei-jiao HU Yue-hua 《Mining Science and Technology》 EI CAS 2009年第4期483-488,共6页
The influence on fine particle aggregation and flotation behavior induced by high intensity conditioning(HIC) from saturated of the slurry with CO2 saturation was investigated.Bubble size measurements were conducted.T... The influence on fine particle aggregation and flotation behavior induced by high intensity conditioning(HIC) from saturated of the slurry with CO2 saturation was investigated.Bubble size measurements were conducted.The effect of dissolved gas,xanthate addition and agitation speed on fine sphalerite particle aggregation-and flotation-behavior were studied.The results show that during HIC in air or CO2 saturated water xanthate acts as a frother.The dissolved gas content in the pulp and HIC play a synergistic role in promoting fine particle aggregation and hence flotation;a significantly enhanced aggregation of fine sphalerite particles in a CO2 saturated slurry by HIC is observed.The aggregate size increased when the agitation speed was increased from 700 r/min to 1500 r/min.Increasing the HIC speed to 1500 r/min caused a positive impact on flotation kinetics.Further increasing the speed to 2000 r/min resulted in an adverse effect on flotation kinetics. 展开更多
关键词 CO2 saturation high intensive conditioning CAVITATION aggregation FLOTATION
下载PDF
Formation of Nanoscale Intermetallic Phases in Ni Surface Layer at High Intensity Implantation of Al Ions 被引量:1
18
作者 I.A.Bozhko S.V.Fortuna +3 位作者 I.A.Kurzina I.B.Stepanov E.V.Kozlov Yu.P.Sharkeev 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2004年第5期583-586,共4页
The results of experimental study of nanoscale intermetallic formation in surface layer of a metal target at ion implantation are presented. To increase the thickness of the ion implanted surface layer the high intens... The results of experimental study of nanoscale intermetallic formation in surface layer of a metal target at ion implantation are presented. To increase the thickness of the ion implanted surface layer the high intensive ion implantation is used. Compared with the ordinary ion implantation, the high intensive ion implantation allows a much thicker modified surface layer. Pure polycrystalline nickel was chosen as a target. Nickel samples were irradiated with Al ions on the vacuum-arc ion beam and plasma flow source 'Raduga-5'. It was shown that at the high intensity ion implantation the fine dispersed particles of Ni3AI, NiAl intermetallic compounds and solid solution Al in Ni are formed in the nickel surface layer of 200 nm and thicker. The formation of phases takes place in complete correspondence with the Ni-AI phase diagram. 展开更多
关键词 high intensive ion implantation Ion-plasma source Intermetallic nanophases
下载PDF
Effects of High-Intensity Intermittent Training on Metabolic Parameters and Irisin Levels in High-Fat-Fed Rats
19
作者 Dongping Tan Wenbin Zhang +1 位作者 Longxia Zheng Huijun Lin 《Journal of Clinical and Nursing Research》 2024年第8期52-59,共8页
Objective:To investigate the effects of high-intensity intermittent training(HIIT)on preventing significant weight gain and provide scientific theoretical support and practical guidance for reducing the occurrence of ... Objective:To investigate the effects of high-intensity intermittent training(HIIT)on preventing significant weight gain and provide scientific theoretical support and practical guidance for reducing the occurrence of obesity.Methods:Twenty-four Sprague-Dawley rats were randomly divided into four groups:the control sedentary group(CS),the high-fat sedentary group(HS),the high-fat continuous exercise group(HE),and the high-fat intermittent exercise group(HI).The HE and HI groups underwent five days of continuous low-intensity exercise and eight weeks of high-intensity intermittent exercise.Weekly monitoring included measurements of food intake and body weight.An automatic biochemical analyzer was used to assess blood lipid and glucose levels,while ELISA kits measured serum insulin and irisin content.H&E staining was used to observe adipocyte size.Results:In the HS group,body weight,blood lipid levels,blood glucose levels,and adipocyte size significantly increased,while the QUICKI index decreased.In the HI group,body weight,blood lipid levels,blood glucose levels,and adipocyte size decreased,and the QUICKI index increased.The effects of high-intensity intermittent exercise were superior to those of continuous low-intensity exercise.In the HI group,serum irisin levels did not change significantly after exercise,while in the HE group,there was a slight upward trend in irisin levels.Conclusion:A high-fat diet induced abnormal metabolism in rats.HIIT effectively prevents metabolic abnormalities induced by a high-fat diet,and its effects are more pronounced than those of low-intensity exercise.HIIT stimulates the secretion of blood irisin,affecting secretion levels,and may represent a novel mechanism for maintaining metabolic homeostasis.This has important implications for controlling significant weight gain. 展开更多
关键词 high intensity interval training RATS Metabolic characterization Irisin
下载PDF
Suppressive effects of exercise-conditioned serum on cancer cells:A narrative review of the influence of exercise mode,volume,and intensity 被引量:1
20
作者 Francesco Bettariga Dennis R.Taaffe +3 位作者 Daniel A.Galvao Chris Bishop Jin-Soo Kim Robert U.Newton 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第4期484-498,F0003,共16页
Cancer is a major cause of morbidity and mortality worldwide,and the incidence is increasing,highlighting the need for effective strategies to treat this disease.Exercise has emerged as fundamental therapeutic medicin... Cancer is a major cause of morbidity and mortality worldwide,and the incidence is increasing,highlighting the need for effective strategies to treat this disease.Exercise has emerged as fundamental therapeutic medicine in the management of cancer,associated with a lower risk of recur-rence and increased survival.Several avenues of research demonstrate reduction in growth,proliferation,and increased apoptosis of cancer cells,including breast,prostate,colorectal,and lung cancer,when cultured by serum collected after exercise in vitro(i.e.,the cultivation of cancer cell lines in an experimental setting,which simplifies the biological system and provides mechanistic insight into cell responses).The underlying mechanisms of exercise-induced cancer suppressive effects may be attributed to the alteration in circulating factors,such as skeletal muscle-induced cytokines(i.e.,myokines)and hormones.However,exercise-induced tumor suppressive effects and detailed information about training interventions are not well investigated,constraining more precise application of exercise medicine within clinical oncology.To date,it remains unclear what role different training modes(i.e.,resistance and aerobic training)as well as volume and intensity have on exercise-condi-tioned serum and its effects on cancer cells.Nevertheless,the available evidence is that a single bout of aerobic training at moderate to vigorous intensity has cancer suppressive effects,while for chronic training interventions,exercise volume appears to be an influential candidate driving cancer inhibitory effects regardless of training mode.Insights for future research investigating training modes,volume and intensity are provided to further our understanding of the effects of exercise-conditioned serum on cancer cells. 展开更多
关键词 Cancer cells high intensity interval training Moderate intensity continuous training Resistance training MYOKINES
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部