期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Design and application of thickness measurement calibration system based on laser displacement sensor
1
作者 SUN Jin YU Zijin 《Baosteel Technical Research》 CAS 2024年第2期39-46,共8页
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th... This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing. 展开更多
关键词 steel plate thickness high precision measurement noncontact thickness measurement laser displace-ment sensor
下载PDF
High Precision Tungsten Isotope Measurements by MC-ICPMS
2
作者 MEI Qingfeng YANG Jinhui 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2017年第S1期273-274,共2页
1 Introduction The short-lived 182Hf-182W system is generally acknowledged as the best chronometer of metal-silicate segregation that occurred during the early evolution of asteroids and terrestrial planets due to its... 1 Introduction The short-lived 182Hf-182W system is generally acknowledged as the best chronometer of metal-silicate segregation that occurred during the early evolution of asteroids and terrestrial planets due to its following properties:(1)Hf-W fractionation commonly occurs during metal-silicate differentiation;(2)Both Hf and W are highly refractory elements,therefore most bulk 展开更多
关键词 high precision Tungsten Isotope measurements by MC-ICPMS HF MC
下载PDF
Establishment and Error Analysis of Model of Interference Fringe Contrast for Laser Tracing Measurement Optical System
3
作者 Hongfang Chen Mengyang Sun +3 位作者 Yinglun Ma Liang Tang Yu Wang Huixu Song 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第4期37-49,共13页
A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performa... A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performance.A comprehensive model of the interference fringe contrast based on the laser tracing system s measurement principle was established in this study.Simulation results based on ZEMAX verified the model.According to the simulation results,the placement angle of the analyzer had a direct influence on the interference fringe contrast.When the angle of the polarized light to the analyzer’s transmission axis increased from 65°to 85°,each contrast of the four-way interference fringes decreased from 0.9996 to 0.3528,the interference fringe contrast is decreased by 65%.Under the split ratio of beam splitters in the interference part(BS 1)of 5∶5,when the splitting ratio of BS 2 changed from 2∶8 to 8∶2,the fringe contrast of the interference signals received by the photodetectors increased,but the injection light intensity onto the PSD reflected by BS 2 decreased.The significant influence of the tracing performance was verified by the experiments.When splitting ratio of BS 2 increased,the contrast of the interference fringes increased.Due to the weakening of the incident light intensity of the PSD caused by the change of BS 2 splitting ratio,the response time of the tracing system is increased by 23.7 ms.As a result,the tracing performance of the laser tracing measurement optical system was degraded.An important theoretical basis was provided to evaluate and improve the accuracy and reliability of laser tracing measurement systems. 展开更多
关键词 interference fringe contrast laser tracing measurement high precision measurement ZEMAX.
下载PDF
Design of High Precision Horizontal Control Network for Large-Scale Hydropower Project
4
作者 ZHANG Zhenglu LUO Changlin +1 位作者 DENG Yong XIE Niansheng 《Geo-Spatial Information Science》 2006年第4期235-239,共5页
A new solution of combination network of GPS and high precise distance measurements with EDM is proposed. Meanwhile, it’s inadvisable only using GPS network without distance measurements. Three schemes: terrestrial n... A new solution of combination network of GPS and high precise distance measurements with EDM is proposed. Meanwhile, it’s inadvisable only using GPS network without distance measurements. Three schemes: terrestrial network, GPS network and combination network are discussed for horizontal control network design of Xiangjiaba Dam in view of precision, reliability, coordinate and outlay in detail. 展开更多
关键词 large-scale hydropower project terrestrial network GPS network combination network of GPS and high precise distance measurements with EDM
下载PDF
Research on key techniques of expendable conductivity temperature depth measuring system 被引量:5
5
作者 CHEN Guangyuan DU Libin +3 位作者 HE Haijing LEI Zhuo ZHANG Qisheng WU Chengxuan 《Instrumentation》 2015年第2期18-27,共10页
This paper analysis the developing of expendable conductivity temperature depth measuring system(XCTD)and introduce its principle of measuring about temperature,salinity and depth of ocean.Some key techniques are put ... This paper analysis the developing of expendable conductivity temperature depth measuring system(XCTD)and introduce its principle of measuring about temperature,salinity and depth of ocean.Some key techniques are put forward.According to the real needs of XCTD,conductivity sensor with high sensitivity is designed by principle of electromagnetic induce,the ocean conductivity from induced electromotive force has been calculated.Adding temperature correction circuit would help to reduce error of conductivity measurement because of sharply changing temperature.Advanced temperature measuring circuit of high precision and the constant current source is used to weaken effect of self-heating of resistance and fluctuation of the source.On respect of remote data transmission,LVDS is a good choice for the purpose of guarantee the quality of data transmitted and the transmission distance is reaching to thousand meters in the seawater.Modular programming method is also brought into this research aimed at improve the stability,reliability and maintainability of the whole measuring system.In February,2015,the trials in South China Sea demonstrate that the developed XCTD realize effective measurement at a speed of 6 knots and detection depth at 800 m.The consistency coefficient of the acquired data is greater than 0.99 and the success rate of probe launching is above 90%. 展开更多
关键词 expendable device XCTD conductivity sensor high precision temperature measuring circuit remote data transmission
下载PDF
A portable high precision three dimensional trace measuring system for underwater target with high speed 被引量:1
6
作者 TIAN Tan, DING Yuzhong and YAO Lan (Harbin Shipbuilding Engineering Institute) 《Chinese Journal of Acoustics》 1991年第1期53-62,共10页
The paper describes a portable high precision three-dimensional trace measuring system for underwater target with high speed. The mathematical model for location, the main error sources, the calibration method for the... The paper describes a portable high precision three-dimensional trace measuring system for underwater target with high speed. The mathematical model for location, the main error sources, the calibration method for the underwater array and the way to correct its state are discussed. Problems about the distance ambiguity and multi-path interference are also analyzed. Part of experimental results on lake and at sea are given as well. 展开更多
关键词 A portable high precision three dimensional trace measuring system for underwater target with high speed high
原文传递
Prototype of time digitizing system for BESⅢ endcap TOF upgrade
7
作者 曹平 孙维佳 +4 位作者 季筱璐 范欢欢 王思宇 刘树彬 安琪 《Chinese Physics C》 SCIE CAS CSCD 2014年第4期55-63,共9页
The prototype of a time digitizing system for the BESⅢ endcap TOF (ETOF) upgrade is introduced in this paper, The ETOF readout electronics has a distributed architecture. Hit signals from the multi-gap resistive pl... The prototype of a time digitizing system for the BESⅢ endcap TOF (ETOF) upgrade is introduced in this paper, The ETOF readout electronics has a distributed architecture. Hit signals from the multi-gap resistive plate chamber (MRPC) are signaled as LVDS by front-end electronics (FEE) and are then sent to the back-end time digitizing system via long shield differential twisted pair cables. The ETOF digitizing system consists of two VME crates, each of which contains modules for time digitization, clock, trigger, fast control, etc. The time digitizing module (TDIG) of this prototype can support up to 72 electrical channels for hit information measurement. The fast control (FCTL) module can operate in barrel or endcap mode. The barrel FCTL fans out fast control signals from the trigger system to the endcap FCTLs, merges data from the endcaps and then transfers to the trigger system. Without modifying the barrel TOF (BTOF) structure, this time digitizing architecture benefits from improved ETOF performance without degrading the BTOF performance. Lab experiments show that the time resolution of this digitizing system can be lower than 20 ps, and the data throughput to the DAQ can be about 92 Mbps. Beam experiments show that the total time resolution can be lower than 45 ps. 展开更多
关键词 BESⅢ endcap upgrade TIME-OF-FLIGHT high precision time measurement readout electronics
原文传递
上一页 1 下一页 到第