期刊文献+
共找到8,060篇文章
< 1 2 250 >
每页显示 20 50 100
Flexible broadband WS_(2)/Si optical position-sensitive detector with high sensitivity and fast speed
1
作者 Yunjie Liu Yupeng Wu +5 位作者 Fuhai Guo Yingming Liu Shirong Zhao Siqi Li Weizhuo Yu Lanzhong Hao 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第6期1217-1224,共8页
Si-based optical position-sensitive detectors(PSDs)have stimulated the interest of researchers due to their wide range of practical applications.However,due to the rigidity and fragility of Si crystals,the application... Si-based optical position-sensitive detectors(PSDs)have stimulated the interest of researchers due to their wide range of practical applications.However,due to the rigidity and fragility of Si crystals,the applications of flexible PSDs have been limited.Therefore,we presented a flexible broadband PSD based on a WS_(2)/Si heterostructure for the first time.A scalable sputtering method was used to deposit WS_(2)thin films onto the etched ultrathin crystalline Si surface.The fabricated flexible PSD device has a broad spectral response in the wavelength range of 450-1350 nm,with a high position sensitivity of~539.8 mV·mm^(−1)and a fast response of 2.3μs,thanks to the strong light absorption,the built-in electrical field at the WS_(2)/Si interface,and facilitated transport.Furthermore,mechanical-bending tests revealed that after 200 mechanical-bending cycles,the WS_(2)/Si PSDs have excellent mechanical flexibility,stability,and durability,demonstrating the great potential in wearable PSDs with competitive performance. 展开更多
关键词 FLEXIBLE position-sensitive detectors WS^(2)heterostructure broad spectral response high sensitivity
下载PDF
Relationship of High Sensitivity C-Reactive Protein with Cardiovascular, Diabetic, and Hepatic Biomarkers
2
作者 Hari Krishnan Krishnamurthy Swarnkumar Reddy +6 位作者 Vasanth Jayaraman Karthik Krishna Qi Song Karenah E. Rajasekaran Tianhao Wang Kang Bei John J. Rajasekaran 《International Journal of Clinical Medicine》 2023年第9期389-401,共13页
Biomarkers are early predictors of various disorders, circulating level of C-reactive protein is a sensitive biomarker of systemic inflammation and may also be associated with the development of diabetic, hepatic, and... Biomarkers are early predictors of various disorders, circulating level of C-reactive protein is a sensitive biomarker of systemic inflammation and may also be associated with the development of diabetic, hepatic, and cardiovascular diseases. In the present study, we aimed to investigate the association between circulating levels of high sensitive C-reactive protein (hs-CRP) and various biomarkers for hepatic, diabetic, and cardiovascular health. The retrospective analysis included 438 individuals who were tested for these panels simultaneously at Vibrant America Clinical Laboratory. The study population included free-living individuals without any preexisting clinical conditions. Among the cardiovascular markers, a positive correlation and significant association was found between high levels of hs-CRP and serum levels of triglycerides (r = 0.0964, p −0.1423, p −0.1216, p < 0.0105) with circulating levels of hs-CRP. Among all the diabetic markers, glucose (r = 0.1547, p < 0.0011) and glycated serum protein (r = 0.1725, p < 0.0003) were positively correlated with circulating hs-CRP. In the hepatic panel, AST, a transaminase that plays a vital role in amino acid metabolism, was found to have a strong positive correlation with hs-CRP (r = 0.2139, p < 0.0001). In conclusion, the results clearly show the association of hs-CRP with diabetic, hepatic, and cardiovascular risk factors indicating its central value as a key marker for several lifestyle-associated disorders. 展开更多
关键词 high sensitive C-Reactive Protein Systemic Inflammation Cardiovascular Disorders DIABETES TRIGLYCERIDES
下载PDF
Introducing the nth-Order Features Adjoint Sensitivity Analysis Methodology for Nonlinear Systems (nth-FASAM-N): I. Mathematical Framework
3
作者 Dan Gabriel Cacuci 《American Journal of Computational Mathematics》 2024年第1期11-42,共32页
This work presents the “n<sup>th</sup>-Order Feature Adjoint Sensitivity Analysis Methodology for Nonlinear Systems” (abbreviated as “n<sup>th</sup>-FASAM-N”), which will be shown to be the... This work presents the “n<sup>th</sup>-Order Feature Adjoint Sensitivity Analysis Methodology for Nonlinear Systems” (abbreviated as “n<sup>th</sup>-FASAM-N”), which will be shown to be the most efficient methodology for computing exact expressions of sensitivities, of any order, of model responses with respect to features of model parameters and, subsequently, with respect to the model’s uncertain parameters, boundaries, and internal interfaces. The unparalleled efficiency and accuracy of the n<sup>th</sup>-FASAM-N methodology stems from the maximal reduction of the number of adjoint computations (which are considered to be “large-scale” computations) for computing high-order sensitivities. When applying the n<sup>th</sup>-FASAM-N methodology to compute the second- and higher-order sensitivities, the number of large-scale computations is proportional to the number of “model features” as opposed to being proportional to the number of model parameters (which are considerably more than the number of features).When a model has no “feature” functions of parameters, but only comprises primary parameters, the n<sup>th</sup>-FASAM-N methodology becomes identical to the extant n<sup>th</sup> CASAM-N (“n<sup>th</sup>-Order Comprehensive Adjoint Sensitivity Analysis Methodology for Nonlinear Systems”) methodology. Both the n<sup>th</sup>-FASAM-N and the n<sup>th</sup>-CASAM-N methodologies are formulated in linearly increasing higher-dimensional Hilbert spaces as opposed to exponentially increasing parameter-dimensional spaces thus overcoming the curse of dimensionality in sensitivity analysis of nonlinear systems. Both the n<sup>th</sup>-FASAM-N and the n<sup>th</sup>-CASAM-N are incomparably more efficient and more accurate than any other methods (statistical, finite differences, etc.) for computing exact expressions of response sensitivities of any order with respect to the model’s features and/or primary uncertain parameters, boundaries, and internal interfaces. 展开更多
关键词 Computation of high-Order sensitivities sensitivities to Features of Model Parameters sensitivities to Domain Boundaries Adjoint sensitivity Systems
下载PDF
Introducing the nth-Order Features Adjoint Sensitivity Analysis Methodology for Nonlinear Systems (nth-FASAM-N): II. Illustrative Example
4
作者 Dan Gabriel Cacuci 《American Journal of Computational Mathematics》 2024年第1期43-95,共54页
This work highlights the unparalleled efficiency of the “n<sup>th</sup>-Order Function/ Feature Adjoint Sensitivity Analysis Methodology for Nonlinear Systems” (n<sup>th</sup>-FASAM-N) by con... This work highlights the unparalleled efficiency of the “n<sup>th</sup>-Order Function/ Feature Adjoint Sensitivity Analysis Methodology for Nonlinear Systems” (n<sup>th</sup>-FASAM-N) by considering the well-known Nordheim-Fuchs reactor dynamics/safety model. This model describes a short-time self-limiting power excursion in a nuclear reactor system having a negative temperature coefficient in which a large amount of reactivity is suddenly inserted, either intentionally or by accident. This nonlinear paradigm model is sufficiently complex to model realistically self-limiting power excursions for short times yet admits closed-form exact expressions for the time-dependent neutron flux, temperature distribution and energy released during the transient power burst. The n<sup>th</sup>-FASAM-N methodology is compared to the extant “n<sup>th</sup>-Order Comprehensive Adjoint Sensitivity Analysis Methodology for Nonlinear Systems” (n<sup>th</sup>-CASAM-N) showing that: (i) the 1<sup>st</sup>-FASAM-N and the 1<sup>st</sup>-CASAM-N methodologies are equally efficient for computing the first-order sensitivities;each methodology requires a single large-scale computation for solving the “First-Level Adjoint Sensitivity System” (1<sup>st</sup>-LASS);(ii) the 2<sup>nd</sup>-FASAM-N methodology is considerably more efficient than the 2<sup>nd</sup>-CASAM-N methodology for computing the second-order sensitivities since the number of feature-functions is much smaller than the number of primary parameters;specifically for the Nordheim-Fuchs model, the 2<sup>nd</sup>-FASAM-N methodology requires 2 large-scale computations to obtain all of the exact expressions of the 28 distinct second-order response sensitivities with respect to the model parameters while the 2<sup>nd</sup>-CASAM-N methodology requires 7 large-scale computations for obtaining these 28 second-order sensitivities;(iii) the 3<sup>rd</sup>-FASAM-N methodology is even more efficient than the 3<sup>rd</sup>-CASAM-N methodology: only 2 large-scale computations are needed to obtain the exact expressions of the 84 distinct third-order response sensitivities with respect to the Nordheim-Fuchs model’s parameters when applying the 3<sup>rd</sup>-FASAM-N methodology, while the application of the 3<sup>rd</sup>-CASAM-N methodology requires at least 22 large-scale computations for computing the same 84 distinct third-order sensitivities. Together, the n<sup>th</sup>-FASAM-N and the n<sup>th</sup>-CASAM-N methodologies are the most practical methodologies for computing response sensitivities of any order comprehensively and accurately, overcoming the curse of dimensionality in sensitivity analysis. 展开更多
关键词 Nordheim-Fuchs Reactor Safety Model Feature Functions of Model Parameters high-Order Response sensitivities to Parameters Adjoint sensitivity Systems
下载PDF
Evaluation of the Key Mechanism Justifying the High Sensitivity of Obese Rodents to Treptozotocin (STZ)
5
作者 Ngounou Eleonore Rochelle Van Wijk Hermann Ngouakam 《Journal of Biosciences and Medicines》 2023年第12期376-394,共19页
Diabetes mellitus (DM) is a metabolic disease caused by the absence or dysfunction of insulin;a hormone secreted by the pancreatic beta cell (β-cell) whenever blood glucose exceeds the normal physiological value. The... Diabetes mellitus (DM) is a metabolic disease caused by the absence or dysfunction of insulin;a hormone secreted by the pancreatic beta cell (β-cell) whenever blood glucose exceeds the normal physiological value. The long-term effects of the disease on the body’s organs are one of the leading causes of death in the world. To alleviate this global burden of DM, a number of studies have been conducted to lower blood glucose levels in patients. For genetic and ethical reasons, humans are far from being appropriate subjects in such investigations and the use of animal models has therefore been the way forward. Streptozotocin (STZ) is a glucosamine-nitrosourea compound that selectively destroys β-cells and has been widely used to induce Type I diabetes in several animal species. Recent literature has shown that a non-diabetic dose of STZ, combined with a high-fat diet (HFD), can mimic Type II diabetes. Yet, researchers seldom provide data to corroborate the high sensitivity of STZ on these animal models. In addition, there are few reports of potentially fatal effects of the use of STZ as a supplement in obese HFD animals when attempting to induce Type II diabetes. The present review article highlights the parameters that could be at the origin of the extreme sensitivity and vulnerability of obese animals to STZ. 展开更多
关键词 STREPTOZOTOCIN high-Fat Diet OBESITY sensitivity
下载PDF
Highly sensitive and stable probe refractometer based on configurable plasmonic resonance with nano-modified fiber core 被引量:1
6
作者 Jianying Jing Kun Liu +3 位作者 Junfeng Jiang Tianhua Xu Shuang Wang Tiegen Liu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第6期38-51,共14页
A dispersion model is developed to provide a generic tool for configuring plasmonic resonance spectral characteristics.The customized design of the resonance curve aiming at specific detection requirements can be achi... A dispersion model is developed to provide a generic tool for configuring plasmonic resonance spectral characteristics.The customized design of the resonance curve aiming at specific detection requirements can be achieved.According to the model,a probe-type nano-modified fiber optic configurable plasmonic resonance(NMF-CPR)sensor with tip hot spot enhancement is demonstrated for the measurement of the refractive index in the range of 1.3332-1.3432 corresponding to the low-concentration biomarker solution.The new-type sensing structure avoids excessive broadening and redshift of the resonance dip,which provides more possibilities for the surface modification of other functional nanomaterials.The tip hot spots in nanogaps between the Au layer and Au nanostars(AuNSs),the tip electric field enhancement of AuNSs,and the high carrier mobility of the WSe_(2)layer synergistically and significantly enhance the sensitivity of the sensor.Ex-perimental results show that the sensitivity and the figure of merit of the tip hot spot enhanced fiber NMF-CPR sensor can achieve up to 2995.70 nm/RIU and 25.04 RIU^(−1),respectively,which are 1.68 times and 1.29 times higher than those of the conventional fiber plasmonic resonance sensor.The results achieve good agreements with numerical simulations,demonstrate a better level compared to similar reported studies,and verify the correctness of the dispersion model.The detection resolution of the sensor reaches up to 2.00×10^(−5)RIU,which is obviously higher than that of the conventional side-polished fiber plasmonic resonance sensor.This indicates a high detection accuracy of the sensor.The dense Au layer effectively prevents the intermediate nanomaterials from shedding and chemical degradation,which enables the sensor with high stability.Furthermore,the terminal reflective sensing structure can be used as a practical probe and can allow a more convenient operation. 展开更多
关键词 fiber photonics sensor customized plasmonic resonance curve nano-modified fiber core tip hot spot effect high sensitivity and stability
下载PDF
Parameters Sensitivity Characteristics of Highly Integrated Valve-Controlled Cylinder Force Control System 被引量:8
7
作者 Kai-Xian Ba Bin Yu +4 位作者 Xiang-Dong Kong Chun-He Li Qi-Xin Zhu Hua-Long Zhao Ling-Jian Kong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第2期159-175,共17页
Nowadays, a highly integrated valve?controlled cylinder(HIVC) is applied to drive the joints of legged robots. Although the adoption of HIVC has resulted in high?performance robot control, the hydraulic force system s... Nowadays, a highly integrated valve?controlled cylinder(HIVC) is applied to drive the joints of legged robots. Although the adoption of HIVC has resulted in high?performance robot control, the hydraulic force system still has problems, such as strong nonlinearity, and time?varying parameters. This makes HIVC force control very diffcult and complex. How to improve the control performance of the HIVC force control system and find the influence rule of the system parameters on the control performance is very significant. Firstly, the mathematical model of HIVC force control system is established. Then the mathematical expression for parameter sensitivity matrix is obtained by applying matrix sensitivity analysis(PSM). Then, aimed at the sinusoidal response under(three factors and three levels) working conditions, the simulation and the experiment are conducted. While the error between the simulation and experiment can’t be avoided. Therefore, combined with the range analysis, the error in the two performance indexes of sinusoidal response under the whole working condition is analyzed. Besides, the sensitivity variation pattern for each system parameter under the whole working condition is figured out. Then the two sensitivity indexes for the three system parameters, which are supply pressure, proportional gain and initial displacement of piston, are proved experimentally. The proposed method significantly reveals the sensitivity characteristics of HIVC force control system, which can make the contribution to improve the control performance. 展开更多
关键词 highly integrated valve?controlled cylinder system Force control system Matrix sensitivity analysis Orthogonal test design sensitivity index
下载PDF
High sensitivity C-reactive protein and cardfiac resynchronization therapy in patients with advanced heart failure 被引量:11
8
作者 Chi CAI Wei HUA Li-Gang DING Jing WANG Ke-Ping CHEN Xin-Wei YANG Zhi-Min LIU Shu ZHANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2014年第4期296-302,共7页
Background The data on the prognostic values of high sensitivity C-reactive protein (hsCRP) levels in patients with advanced symp-tomatic heart failure (HF) receiving cardiac resynchronization therapy (CRT) are ... Background The data on the prognostic values of high sensitivity C-reactive protein (hsCRP) levels in patients with advanced symp-tomatic heart failure (HF) receiving cardiac resynchronization therapy (CRT) are scarce. The aim of present study was to investigate the association of serum hsCRP levels with left ventricle reverse remodeling after six months of CRT as well as long-term outcome. Methods A total of 232 CRT patients were included. The assessment of hsCRP values, clinical status and echocardiographic data were performed at baseline and after six months of CRT. Long-term follow-up included all-cause mortality and hospitalizations for HF. Results During the mean follow-up periods of 31.3 ± 31.5 months, elevated hsCRP (〉3 mg/L) prior to CRT was associated with a significant 2.39-fold increase (P=0.006) in the risk of death or HF hospitalizations. At 6-month follow-up, patients who responded to CRT showed significant reductions or maintained low in hsCRP levels (–0.5 ± 4.1 mg/L reduction) compared with non-responders (1.7 ± 6.1 mg/L increase, P=0.018). Com-pared with patients in whom 6-month hsCRP levels were reduced or remained low, patients in whom 6-month hsCRP levels were increased or maintained high experienced a significantly higher risk of subsequent death or HF hospitalizations (Log-rank P〈0.001). The echocardio-graphic improvement was also better among patients in whom 6-month hsCRP levels were reduced or remained low compared to those in whom 6-month hsCRP levels were raised or maintained high. Conclusions Our findings demonstrated that measurement of baseline and follow-up hsCRP levels may be useful as prognostic markers for timely potential risk stratification and subsequent appropriate treatment strategies in patients with advanced HF undergoing CRT. 展开更多
关键词 Cardiac resynchronization therapy Clinical outcome Heart failure high sensitivity C-reactive protein
下载PDF
Myeloperoxidase and High-Sensitivity C-Reactive Protein for Predicting Major Adverse Cardiovascular Events in Patients with Coronary Heart Disease 被引量:6
9
作者 Chenggui Liu Linong Chen +3 位作者 Yinzhong Yang Cheng Huang Jun Luo Duanliang Peng 《International Journal of Clinical Medicine》 2015年第4期262-270,共9页
Background: Research has shown that high-sensitivity C-reactive protein (hs-CRP) is a major inflammatory marker for prediction of acute coronary syndrome (ACS). Myeloperoxidase (MPO) also plays an important role in at... Background: Research has shown that high-sensitivity C-reactive protein (hs-CRP) is a major inflammatory marker for prediction of acute coronary syndrome (ACS). Myeloperoxidase (MPO) also plays an important role in atherosclerosis initiation and development. In present study, the major adverse cardiovascular events (MACEs) of patients with coronary heart disease (CHD) were investigated. Methods: MPO, hs-CRP and ACS-related risk factors from 201 ACS (78 AMI and 123 UAP) and 210 non-ACS (84 SAP and 126 non-CHD) patients confirmed by coronary angiography were detected, and the data were analyzed with receiver operating characteristic (ROC) curve and Spearman’s correlation coefficients. MACEs of 285 CHD patients were investigated during the 4-year period follow-up from March 2010 to May 2014. Results: The areas under ROC curve for diagnosing ACS were 0.888 (95% CI 0.843 - 0.933) for MPO, and 0.862 (95% CI 0.815-0.910) for hs-CRP, respectively. There were significantly correlations between MPO and hs-CRP in both ACS and non-ACS groups. Regarding to ACS patients, both MPO and hs-CRP were positively correlated with BMI, TC, TG, LDL-C and Hcy. Prospective study demonstrated that the incidences of MACEs associated significantly with elevated MPO baseline level (yes vs no, OR 7.383, 95% CI 4.095 - 13.309) and high hs-CRP baseline level (yes vs no, OR 4.186, 95% CI 2.469 - 7.097) in CHD patients. Conclusions: The present study provides the epidemiological evidence that elevated baseline MPO and hs-CRP levels are both valuable predictors of MACEs in CHD patients. MPO and hs-CRP would prompt the progression of atherosclerosis and development from SAP to ACS. 展开更多
关键词 MYELOPEROXIDASE high sensitivity C-Reactive Protein Acute CORONARY SYNDROME CORONARY HEART Disease Major ADVERSE CARDIOVASCULAR Events
下载PDF
Influence and sensitivity analysis of thermal parameters on temperature field distribution of active thermal insulated roadway in high temperature mine 被引量:6
10
作者 Weijing Yao Jianyong Pang +1 位作者 Qinyong Ma Happiness Lyimo 《International Journal of Coal Science & Technology》 EI CAS CSCD 2021年第1期47-63,共17页
To study active heat insulation roadway in high temperature mines,the typical high temperature roadway of−965 m in Zhujidong Coal Mine of Anhui,China,is selected as prototype.The ANSYS numerical simulation method is u... To study active heat insulation roadway in high temperature mines,the typical high temperature roadway of−965 m in Zhujidong Coal Mine of Anhui,China,is selected as prototype.The ANSYS numerical simulation method is used for sensitivity analysis of heat insulation layer with different thermal conductivity and thickness,as well as surrounding rock with different thermal conductivity and temperature on a heat-adjusting zone radius,surrounding rock temperature field and wall temperature.The results show that the heat-adjusting zone radius will entirely be in the right power index relationship to the ventilation time.Decrease in thermal conductivity and increase in thickness of insulation layer can effectively reduce the disturbance of airflow on the surrounding rock temperature,hence,beneficial for decreasing wall temperature.This favourable trend significantly decreases with ventilation time,increase in thermal conductivity and temperature of surrounding rock,heat-adjusting zone radius,surrounding rock temperature field,and wall temperature.Sensitivity analysis shows that the thermal physical properties of surrounding rock determine the temperature distribution of the roadway,hence,temperature of surrounding rock is considered as the most sensitive factor of all influencing factors.For the spray layer,thermal conductivity is more sensitive,compared to thickness.It is concluded that increase in the spray layer thickness is not as beneficial as using low thermal conductivity insulation material.Therefore,roadway preferential consideration should be given to the rocks with low temperature and thermal conductivity.The application of the insulation layer has positive significance for the thermal environment control in mine roadway,however,increase in the layer thickness without restriction has a limited effect on the thermal insulation. 展开更多
关键词 high temperature mine Active thermal insulation Temperature field of surrounding rock Numerical simulation sensitivity analysis
下载PDF
The prognostic role of high-sensitivity C-reactive protein in patients with acute myocardial infarction 被引量:5
11
作者 Ekaterina A Polyakova Evgeny N Mikhaylov 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第7期379-383,共5页
1 Introduction Inflammation is one of the main mechanisms in the pathogenesis of atherosclerosis,and the interest to the evaluation of inflammatory biomarkers in coronary artery disease(CAD)has been increasing over th... 1 Introduction Inflammation is one of the main mechanisms in the pathogenesis of atherosclerosis,and the interest to the evaluation of inflammatory biomarkers in coronary artery disease(CAD)has been increasing over the last decade.[1,2]Destabilization of chronic artery plaques,which leads to acute coronary syndromes,has been associated with inflammatory status.[1,3]。 展开更多
关键词 Atrial fibrillation Coronary artery disease high sensitive C-reactive protein Myocardial infarction PROGNOSIS
下载PDF
Relationship between high sensitivity C-reactive protein and angiographic severity of coronary artery disease 被引量:4
12
作者 Nadia Bouzidi Mejdi Ben Messaoud +2 位作者 Faouzi Maatouk Habib Gamra Salima Ferchichi 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第5期256-263,共8页
Background Coronary artery disease(CAD)remains a leading cause of morbidity and mortality.Cytokines play a potential role in atherosclerosis pathogenesis and progression.We investigated the association between high se... Background Coronary artery disease(CAD)remains a leading cause of morbidity and mortality.Cytokines play a potential role in atherosclerosis pathogenesis and progression.We investigated the association between high sensitive C-reactive protein(hs CRP)and severity of CAD.Methods CAD patients were stratified according to hs CRP cut-off value into high levels hs CRP group(≥8.4 mg/L)and low levels hs CRP group(<8.4 mg/L).Severity of CAD was assessed according to artery stenosis degree and the number of vessel involved.Statistical analysis was performed using Statistical Package for the Social Sciences(SPSS,version 23.0).Results The mean age was 60.3±11.0 years.The level of hs CRP was increased and ranged from 0.2 to 1020.0 mg/L.Biochemical risk factors and severity of CAD didn’t show significant differences between the two groups.In multivariate linear analysis,cardiac troponin I(c Tn I)and serum amyloid A(SAA)were predictors of hs CRP.As shown in receiver operating characteristic(ROC)curve analysis performed in patients with ST-segment elevation myocardial infarction(STEMI)and compared to myonecrosis biomarkers,hs CRP(area under the curve(AUC):0.905;95%CI:0.844-0.966;P<0.001)could be a powerful predictor marker in evaluating the infarct size after myocardial infarction but not better than c Tn I.Conclusions Hs CRP levels were not associated with the severity of CAD but could be useful in the evaluation of myocardial necrosis in patients with STEMI. 展开更多
关键词 Coronary artery disease high sensitive C-reactive protein SEVERITY
下载PDF
High-Porosity Foam-Based Iontronic Pressure Sensor with Superhigh Sensitivity of 9280 kPa^(-1) 被引量:3
13
作者 Qingxian Liu Yuan Liu +3 位作者 Junli Shi Zhiguang Liu Quan Wang Chuan Fei Guo 《Nano-Micro Letters》 SCIE EI CAS CSCD 2022年第2期12-23,共12页
Flexible pressure sensors with high sensitivity are desired in the fields of electronic skins,human-machine interfaces,and health monitoring.Employing ionic soft materials with microstructured architectures in the fun... Flexible pressure sensors with high sensitivity are desired in the fields of electronic skins,human-machine interfaces,and health monitoring.Employing ionic soft materials with microstructured architectures in the functional layer is an effective way that can enhance the amplitude of capacitance signal due to generated electron double layer and thus improve the sensitivity of capacitive-type pressure sensors.However,the requirement of specific apparatus and the complex fabrication process to build such microstructures lead to high cost and low productivity.Here,we report a simple strategy that uses open-cell polyurethane foams with high porosity as a continuous three-dimensional network skeleton to load with ionic liquid in a one-step soak process,serving as the ionic layer in iontronic pressure sensors.The high porosity(95.4%) of PU-IL composite foam shows a pretty low Young's modulus of 3.4 kPa and good compressibility.A superhigh maximum sensitivity of 9,280 kPa^(-1) in the pressure regime and a high pressure resolution of 0.125% are observed in this foam-based pressure sensor.The device also exhibits remarkable mechanical stability over 5,000 compression-release or bending-release cycles.Such high porosity of composite structure provides a simple,cost-effective and scalable way to fabricate super sensitive pressure sensor,which has prominent capability in applications of water wave detection,underwater vibration sensing,and mechanical fault monitoring. 展开更多
关键词 high porosity Elastic modulus Compression deformation Iontronic pressure sensor Superhigh sensitivity
下载PDF
High Sensitivity Acquisition Algorithm for DSSS Signal with Data Modulation 被引量:3
14
作者 SHEN Yuyao WANG Yongqing +1 位作者 CHEN Jingyao WU Siliang 《China Communications》 SCIE CSCD 2015年第4期76-85,共10页
In direct sequence spread spectrum communication both for satelliteto-ground and inter-satellite links, the system constrains due to radio frequency spectral occupation, channel data throughput and link performances i... In direct sequence spread spectrum communication both for satelliteto-ground and inter-satellite links, the system constrains due to radio frequency spectral occupation, channel data throughput and link performances in terms of data channel coding which might result in a signal structure where the symbol duration is shorter than the pseudo code period. This can generate some difficulties in the DSSS signal acquisition due to the polarity inversion caused by the data modulation. To eliminate the influence due to polarity inversion, this paper proposes a novel acquisition algorithm based on the simultaneous search of the code phase, data phase and Doppler frequency. In the proposed algorithm the data phase is predicted and the correlation period for the coherent integration can be set equal to the symbol duration. Then non-coherent accumulation over different symbol is implemented in order to enhance the acquisition algorithm sensitivity; the interval of non-coherent accumulation is the least common multiple between the symbol duration and the pseudo code period. The algorithm proposed can largely minimize the SNR loss caused by data polarity inversion and enhance acquisition performance without a noticeable increase in hardware complexity. Theoretical analysis, simulation and measured results verify the validity of the algorithm. 展开更多
关键词 DSSS signal acquisition dataphase prediction data polarity inversion segment search high sensitivity
下载PDF
High-Sensitivity Acquisition of Ultrahigh Dynamic Direct Sequence Spread Spectrum Signals in Space Communications 被引量:2
15
作者 徐颖 袁洪 《China Communications》 SCIE CSCD 2013年第10期26-36,共11页
According to the requirements of the high-sensitivity acquisition of Direct Sequence Spread Spectrum(DSSS) signals under ultrahigh dynamic environments in space communications, a three-dimensional joint search of the ... According to the requirements of the high-sensitivity acquisition of Direct Sequence Spread Spectrum(DSSS) signals under ultrahigh dynamic environments in space communications, a three-dimensional joint search of the phase of Pseudo-Noise-code(PN-code),Doppler frequency and its rate-of-change is presented to achieve high sensitivity in sensing high-frequency dynamics. By eliminating the correlation peak loss caused by ultrahigh Doppler frequency and its rate-of-change offset,the proposed method improves the acquisition sensitivity by increasing the non-coherent accumulation time. The validity of the algorithm is proved by theoretical analysis and simulation results. It is shown that signals with a carrier- to-noise ratio as low as 39 dBHz can be captured with high performance when the Doppler frequency is up to ±1 MHz and its rate-of-change is up to ±200 kHz/s. 展开更多
关键词 direct sequence spread spectrum signals space communications ACQUISITION high sensitivity ultrahigh dynamic
下载PDF
High-Sensitivity Ozone Sensing Using 280 nm Deep Ultraviolet Light-Emitting Diode for Detection of Natural Hazard Ozone 被引量:1
16
作者 Yoshinobu Aoyagi Misaichi Takeuchi +6 位作者 Kaoru Yoshida Masahito Kurouchi Tsutomu Araki Yasushi Nanishi Hiroyasi Sugano Yumi Ahiko Hirotaka Nakamura 《Journal of Environmental Protection》 2012年第8期695-699,共5页
Recently ozone is one of natural hazards which comes from cars, industry using ozone for sterilization of organic and inorganic materials and for water purification. So, ozone sensing becomes very important, and conve... Recently ozone is one of natural hazards which comes from cars, industry using ozone for sterilization of organic and inorganic materials and for water purification. So, ozone sensing becomes very important, and convenient and accurate ozone sensor is required. A new high sensitivity ozone sensing system using an deep ultra-violet light emitting diode (DUV-LED) operated at the wavelength of 280 nm has been successfully constructed. The fabrication of diode operated at 280 nm is much easier than that of DUV-LED operated at Hg lamp wavelength of 254 nm. The system is compact and possible to sense the ozone concentration less than 0.1 ppm with an accuracy of 0.5% easily with low power DUV-LED of around 200 micro Watts operated at 280 nm without any data processing circuit. 展开更多
关键词 OZONE SENSING Deep Ultra VIOLET Light EMITTING Diode DUV-LED high sensitivity Long Life Compact
下载PDF
Optimal configuration strategy of energy storage system in high photovoltaic penetration micro-grid based on voltage sensitivity analysis 被引量:1
17
作者 Ouyang Jing Pan Guobin +2 位作者 Chen Jinxin Chai Fushuai Zhang Libin 《High Technology Letters》 EI CAS 2019年第3期294-302,共9页
Energy storage is an effective measure to deal with internal power fluctuation of micro-grid and ensure stable operation, especially in the micro-grid with high photovoltaic(PV) penetration. Its capacity configuration... Energy storage is an effective measure to deal with internal power fluctuation of micro-grid and ensure stable operation, especially in the micro-grid with high photovoltaic(PV) penetration. Its capacity configuration is related to the steady, safety and economy of micro-grid.In order to improve the absorptive capacity of micro-grid on maximizing the use of distributed PV power in micro-grid, and improve the power quality, an optimal energy storage configuration strategy is proposed, which takes many factors into account, such as the topology of micro-grid, the change of irradiance, the load fluctuation and the cable. The strategy can optimize the energy storage allocation model to minimize the storage power capacity and optimize the node configuration.The key electrical nodes are identified by using the sensitivity coefficient of the voltage, and then the model is optimized to simplify calculation. Finally, an example of the European low-voltage micro-grid and a micro-grid system in the laboratory is used to verify the effectiveness of the proposed method.The results show that the proposed method can optimize the allocation of capacity and the node of the energy storage system. 展开更多
关键词 high photovoltaic(PV) penetration MICRO-GRID energy storage configuration voltage sensitive coefficient
下载PDF
HIGH RESOLUTION, HIGH SENSITIVITY MOIRE METHOD
18
作者 王朝阳 戴福隆 蒋小林 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1999年第2期176-181,共6页
Based on geometric moire method, moire interferometry and microscopic moire interferometry, a high spatial resolution and high sensitivity geometric microscopic moire method is presented. Geometric micron-moire patter... Based on geometric moire method, moire interferometry and microscopic moire interferometry, a high spatial resolution and high sensitivity geometric microscopic moire method is presented. Geometric micron-moire patterns are produced by the superposition of two high frequency gratings through a microscope system. Compared with other grating-based photo-mechanics methods, microscopic moire method could provide whole-field moire patterns of both high spatial resolution and high sensitivity. The frequency of specimen and reference gratings used in this method can be from 1 line/mm to 10000 lines/mm. Additionally, a 4F optical filter system is used to enhance the contrast of microscopic moire patterns effectively. 展开更多
关键词 high spatial resolution high sensitivity geometric moire MICROSCOPE
下载PDF
High-sensitivity cardiac troponins in everyday clinical practice 被引量:4
19
作者 Johannes Mair 《World Journal of Cardiology》 CAS 2014年第4期175-182,共8页
High-sensitivity cardiac troponin(hs-cTn) assays are increasingly being used in many countries worldwide,however,a generally accepted definition of high-sen-sitivity is still pending.These assays enable cTn mea-sureme... High-sensitivity cardiac troponin(hs-cTn) assays are increasingly being used in many countries worldwide,however,a generally accepted definition of high-sen-sitivity is still pending.These assays enable cTn mea-surement with a high degree of analytical sensitivity with a low analytical imprecision at the low measuring range of cTn assays(coefficient of variation of < 10% at the 99th percentile upper reference limit).One of the most important advantages of these new assays is that they allow novel,more rapid approaches to rule in or rule out acute coronary syndromes(ACSs) than with previous cTn assay generations which are still more commonly used in practice worldwide.hs-cTn is also more sensitive for the detection of myocardial damage unrelated to acute myocardial ischemia.Therefore,the increase in early diagnostic sensitivity of hs-cTn assays for ACS comes at the cost of a reduced ACS specificity,because more patients with other causes of acute or chronic myocardial injury without overt myocardial isch-emia are detected than with previous cTn assays.As hs-cTn assays are increasingly being adopted in clinical practice and more hs-cTn assays are being developed,this review attempts to synthesize the available clinical data to make recommendations for their everyday clini-cal routine use. 展开更多
关键词 Cardiac TROPONIN high-sensitivity Diagno-sis ACUTE MYOCARDIAL INFARCTION ACUTE coronary syn-drome Review
下载PDF
Elderly patients with non-cardiac admissions and elevated highsensitivity troponin:the prognostic value of renal function
20
作者 Ioanna Samara Stavroula Tsiara +6 位作者 Michail I Papafaklis Konstantinos Pappas Georgios Kolios Nikolaos Vryzas Lampros K Michalis Eleni T Bairaktari Christos S Katsouras 《World Journal of Cardiology》 2021年第10期566-573,共8页
BACKGROUND High-sensitivity cardiac troponin(hs-cTn)levels are frequently elevated in elderly patients presenting to the emergency department for non-cardiac events.However,most studies on the role of elevated hs-cTn ... BACKGROUND High-sensitivity cardiac troponin(hs-cTn)levels are frequently elevated in elderly patients presenting to the emergency department for non-cardiac events.However,most studies on the role of elevated hs-cTn in elderly populations have investigated the prognostic value of hs-cTn in patients with a specific diagnosis or have assessed the relationship between hs-cTn and comorbidities.AIM To investigate the in-hospital prognosis of consecutive elderly patients admitted to the Internal Medicine Department with acute non-cardiac events and increased hs-cTnI levels.METHODS In this retrospective study,we selected patients who were aged≥65 years and admitted to the Internal Medicine Department of our hospital between January 2019 and December 2019 for non-cardiac reasons.Eligible patients were those who had hs-cTnI concentrations≥100 ng/L.We investigated the independent predictors of in-hospital mortality by multivariable logistic regression analysis.RESULTS One hundred and forty-six patients(59%female)were selected with an age range from 65 to 100(mean±SD:85.4±7.61)years.The median hs-cTnI value was 284.2 ng/L.For 72(49%)patients the diagnosis of hospitalization was an infectious disease.The overall in-hospital mortality was 32%(47 patients).Individuals who died did not have higher hs-cTnI levels compared with those who were discharged alive(median:314.8 vs 282.5 ng/L;P=0.565).There was no difference in mortality in patients with infectious vs non-infectious disease(29%vs 35%).Multivariable analysis showed that age(OR 1.062 per 1 year increase,95%CI:1.000-1.127;P=0.048)and creatinine levels(OR 2.065 per 1 mg/dL increase,95%CI:1.383-3.085;P<0.001)were the only independent predictors of death.Mortality was 49%in patients with eGFR<30 mL/min/1.73 m2.CONCLUSION Myocardial injury is a malignant condition in elderly patients admitted to the hospital for non-cardiac reasons.The presence of severe renal impairment is a marker of extremely high in-hospital mortality. 展开更多
关键词 Internal medicine high sensitivity troponin ELDERLY Non-cardiac admissions Renal function PROGNOSIS
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部