Objective:The clinical grading system for varicoceles is subjective and dependent on clinician experience.Color Doppler ultrasound(US)has not been standardized in the diagnosis of varicoceles.We aimed to determine if ...Objective:The clinical grading system for varicoceles is subjective and dependent on clinician experience.Color Doppler ultrasound(US)has not been standardized in the diagnosis of varicoceles.We aimed to determine if US measurement of varicocele could be predictive of World Health Organization(WHO)varicocele grade.Methods:Men who presented for either scrotal pain or infertility to a tertiary men’s health clinic underwent physical examination,and varicoceles were graded following WHO criteria(0Zsubclinical,1,2,3).US was used to measure largest venous diameter in the pampiniform plexus bilaterally at rest and during Valsalva maneuver.Receiver operator characteristic curve analysis was used to determine if resting diameter,diameter during Valsalva,or change in diameter between at rest and during Valsalva provided the highest sensitivity and specificity for determining clinical grade.Threshold values for diameter were determined from these receiver operator characteristic curves.Results:A total of 102 men(50 with clinical varicocele and 52 with subclinical varicocele)were included.Diameter at rest was the best ultrasonographic discriminator between subclinical and clinical varicoceles(area under the curve[AUC]Z0.67)with a diameter threshold of 3.0 mm(sensitivity 79%,specificity 42%).Diameter during Valsalva had the greatest AUC for determining clinical Grades 1 versus 2(AUCZ0.57)with diameter threshold of 5.7 mm(sensitivity 71%,specificity 33%).For differentiating between Grades 2 and 3,diameter at rest had the greatest AUC of 0.65 with a threshold of 3.6 mm(sensitivity 71%,specificity 58%).Conclusion:Our results corroborate other studies that have shown a weak correlation between US and clinical grading.The use of diameter during Valsalva was less predictive than diameter at rest and was only clinically significant in differentiating between Grade 1 and 2 varicocele.A standardized method for determining clinically relevant varicoceles on US would allow for improved patient counseling and clinical decision-making.展开更多
The World Journal of Cardiology published an article written by Kuwahara et al that we take the pleasure to comment on.We focused our attention on venous congestion.In intensive care settings,it is now widely accepted...The World Journal of Cardiology published an article written by Kuwahara et al that we take the pleasure to comment on.We focused our attention on venous congestion.In intensive care settings,it is now widely accepted that venous congestion is an important clinical feature worthy of investigation.Evaluating venous Doppler profile abnormalities at multiple sites could suggest adequate treatment and monitor its efficacy.Renal dysfunction could trigger or worsen fluid overload in heart disease,and cardio-renal syndrome is a well-characterized spectrum of disorders describing the complex interactions between heart and kidney diseases.Fluid overload and venous congestion,including renal venous hypertension,are major determinants of acute and chronic renal dysfunction arising in heart disease.Organ congestion from venous hypertension could be involved in the development of organ injury in several clinical situations,such as critical diseases,congestive heart failure,and chronic kidney disease.Ultrasonography and abnormal Doppler flow patterns diagnose clinically significant systemic venous congestion.Cardiologists and nephrologists might use this valuable,noninvasive,bedside diagnostic tool to establish fluid status and guide clinical choices.展开更多
AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:T...AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG.展开更多
BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagog...BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagogastroduodenoscopy(EGD)and high-frequency intraluminal ultrasound(HFIUS)for type 1 gastric varices(GOV1)after EVL and to identify the predictability for rebleeding of EGD and HFIUS.METHODS In liver cirrhosis patients with GOV1,we performed endoscopic follow-up using EGD and HFIUS synchronously after EVL for hemorrhage from GOV1.Endoscopic grading and red color signs were analyzed using EGD,and the largest variceal cross-sectional areas were measured using HFIUS.In addition,1-year follow-up was performed.Variceal rebleeding was defined as the presence of hematemesis,hematochezia,or melena without other evidence of bleeding on endoscopic follow-up.RESULTS In 26 patients with GOV1,variceal cross-sectional areas on HFIUS of GOV1 was poorly correlated with EGD grading of GOV1(r=0.36).In 17 patients who completed the 1-year follow-up,variceal cross-sectional areas on HFIUS was a good predictor of subsequent rebleeding,whereas EGD grading was not a predictor of subsequent rebleeding.CONCLUSION HFIUS measurement is more predictive of GOV1 rebleeding than EGD grading,so HFIUS measurement may be necessary for endoscopic follow-up after EVL in patients with GOV1.展开更多
<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging ev...<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types.展开更多
Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and in...Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties.展开更多
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ...High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.展开更多
Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clin...Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clinical medication and evaluation of therapeutic effect.Methods:From December 2018 to December 2019,110 patients with DPN who met the inclusion and exclusion criteria were divided into observation group and control group according to different treatment plans.The control group was treated withα-lipoic acid,and the observation group was treated withα-lipoic acid combined with traditional Chinese medicine encapsulation treatment,and used high-frequency ultrasound,nerve conduction velocity and serological examination to comprehensively evaluate the effectiveness of the two treatment methods.Results:The mean amplitude of glycemic excursions(MAGE)value of the observation group and the control group after treatment was significantly lower than before treatment(P<0.05);After treatment,the SCV of the ulnar nerve,median nerve,and common peroneal nerve in the two groups was significantly faster than before treatment(P<0.05).Similar to SCV,the MCV of the three nerves measured after treatment in the two groups was significantly faster than before treatment(P<0.05).Compared between the groups after treatment,the three kinds of nerve SCV and MCV in the observation group were significantly faster than those in the control group(P<0.05).The cross-sectional area(CSA)value of the ulnar nerve,median nerve and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).Compared with the control group after treatment,the three nerves CSA in the observation group was significantly lower than that in the control group(P<0.05).Abnormal ultrasound performance:The proportion of abnormal ultrasound performances of the ulnar nerve,median nerve,and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).The composition ratio of internal echo reduction and ambiguity in the observation group after three nerve treatments was significantly lower than that in the control group after treatment(P<0.05).In the correlation analysis,the three kinds of nerve CSA before and after treatment were negatively correlated with SCV and amplitude(P<0.05),and positively correlated with latency(P<0.05).Conclusion:The combination ofα-lipoic acid and Chinese medicine encapsulation technology has a good effect on the treatment and repair of DPN nerve damage,and can be routinely applied in clinical treatment.High-frequency ultrasound can intuitively observe changes in peripheral nerves and can be used to evaluate the prognosis of DPN.展开更多
Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in ha...Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in hand and foot were retrospectively analyzed,including the location,size,shape,boundary,internal echo and posterior echo,surrounding relationship and blood flow.Results:Among 65 cases,there were 26 cases of tendon sheath cyst,16 cases of tenosynovitis giant cell tumor,10 cases of hemangioma,4 cases of tendon sheath fibroma,3 cases of epidermoid cyst,2 cases of Schwannoma,2 cases of fibrolipoma,1 case of angiolipoma and 1 case of neurofibroma.The preoperative and postoperative pathological diagnoses of 45 cases,accounting for 69.23%,were consistent,3 cases(4.62%)were misdiagnosed,which included that 2 cases of tenosynovitis giant cell tumor were misdiagnosed as tendon sheath cyst,1 case of neurofibroma as epidermoid cyst,and the preoperative diagnosis of the rest 17 cases(26.15%)were indefinite.Conclusion:The high-frequency ultrasound can diagnose properties of lumps in foot and hand well,providing diagnosis basis for further treatment in clinic.展开更多
AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patien...AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding.展开更多
The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tu...The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tumors were enrolled in this study.After intravenous administration of levovist,the color Doppler signals of normal hepatic vessels were enhanced.In various hepatic tumors,the different patterns of tumor vascularity were observed,which had not been demonstrated in conventional non contrast color Doppler imaging.In 11 of 16 patients with hepatocarcinoma,additional color Doppler signals were observed in the central part of the tumors.On the contrary,3 patients with metastatic liver lesions the enhanced color Doppler signals appear only at the peripheral of tumors.A typical rim like color enhancement was seen in 2 of the 3 cases.In six patients with hepatic hemangiomas contrast enhanced color Doppler imaging demonstrated the blood vessels at the margin of the neoplasms.Contrast enhanced color Doppler imaging improves the visualization of the hepatic neoplasm vascularity.This technique holds great promise for detecting small liver tumors and differentiating hepatic neoplasms.展开更多
Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler u...Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler ultrasound guidance in choosing the optimal treatment modality. Methods Infantile patients who were clinical diagnosed as hemangiomas were randomly divided into group A, who had color Doppler ultrasound examinations before the treatment, and group B who had the treatment without ultrasound evaluation. Patients in the group A were assigned into subgroups according to the depth of lesion by sonography: group A-1 for those who had a lesion depth 〈1.2 mm, and took intense pulsed light therapy; group A-2 for those who had a lesion depth ≥1.2mm and 〈 3 mm, and took long pulse 1064 nm Nd:YAG laser therapy; group A-3 for those who had a lesion depth ≥3mm and 〈5 mm, and were treated by IPL combined with long pulse 1064 nm Nd:YAG laser treatment; Group A-4 for those who had a lesion depth ≥5 mm, and took lauromacrogol injection therapy. Patients in the group B took long pulse 1064 nm Nd:YAG laser treatment without preoperative ultrasound evaluation. The efficacy and adverse reactions of the treatments between the groups were evaluated and compared statistically. Results Totally 113 patients with 128 skin lesions were enrolled in this study, 85 in the group A (mean age 6.8±7.9 months) and 28 in the group B (mean age 6.9±9.9 months). The mean depth of hemangioma was 3.3±1.1 mm in the group A, ranging from 0.5-7.8 mm, with 0.8±0.4 mm, 2.2±0.4 mm, 4.2±0.6 mm and 6.2±0.7 mm in group A1, A2, A3 and A4, respectively. The cure rates and effective rates in the group A were significantly higher than those in the group B (cure rates: 64.5% vs 56.3%, U=3.378, P=0.045; effective rates: 89.5% vs 78.1%, U=4.163, P=0.041). The adverse effect rates of the group A (vesicle 20.0%, pigmentation 46.9%, scarring 17.7%) were lower than those of the group B (vesicle 21.9%, pigmentation 60.4%, scarring 25.0%). Incidences of pigmentation and scarring were statistically significantly different (U=3.884, P=0.034, and U=4.016, P=0.032 respectively) between the two groups. Conclusion With the guidance of color Doppler ultrasound, the efficacy and safety of long pulse 1064 nmNd:YAG laser, intense pulsed light, and lauromacrogol injection in the treatment of infantile hemangioma have better outcomes compared to laser treatment alone without preoperative ultrasound examination.展开更多
Purpose: Intrapartum Doppler velocimetry is a non-invasive investigation method. This method is useful for evaluating the pathophysiological mechanisms underlying changes in fetal heart rate. This study aimed to deter...Purpose: Intrapartum Doppler velocimetry is a non-invasive investigation method. This method is useful for evaluating the pathophysiological mechanisms underlying changes in fetal heart rate. This study aimed to determine the usefulness of Doppler ultrasound findings during labor in high-risk women on determining the mode of delivery and outcome of the newborn. Methods: A cross-sectional study was conducted from January 1, 2015 to December 31, 2015 on 100 high-risk pregnant women during labor. The study was performed in the Maternity Teaching Hospital in Erbil City, Kurdistan Region, Iraq. Results: The majority of women (77%) had a normal end-diastolic blood flow pattern through the umbilical artery. A total of 76.9% of those with abnormal Doppler results had a Cesarean delivery compared with only 9.5% of those with normal Doppler results (p p p = 0.07) and fifth minutes (p = 0.01). Conclusions: Abnormal umbilical artery Doppler ultrasound findings in high-risk pregnancies for women in labor are associated with increased rates of emergency cesarean sections and a poor outcome of the newborn.展开更多
Background: Semen evaluation is used to estimate the testicular function. In bulls, the spermatozoa present in the ejaculate are the result of a process that begun more than 2 mo earlier, bequeathing a delayed depicti...Background: Semen evaluation is used to estimate the testicular function. In bulls, the spermatozoa present in the ejaculate are the result of a process that begun more than 2 mo earlier, bequeathing a delayed depiction of the actual function of the testis. Since testis vascularization might be critical for the gonad function, selected pulse wave Doppler ultrasound parameters were assessed in this study, for instance the peak systolic velocity, the end diastolic velocity and the resistive index of the testicular artery along the spermatic cord, the marginal portion of the testicular artery and the intratesticular branches of the testicular artery both in healthy adult and young bulls.Correlations between these parameters and characteristics of semen that was collected numerous times, before and after the Doppler ultrasound examination.Results: The peak systolic velocity and the end diastolic velocity measured in the testicular artery along the spermatic cord(supratesticular artery – SA) were variable among the bulls and within individual bulls, likely due to the convoluted course of the vessel. The resistive index was found highly repeatable in the same bull. A reduction in the resistive index was found between the supratesticular artery and the marginal portion of the testicular artery(P < 0.01), and between the marginal portion of the testicular artery and the intratesticular branches of the testicular artery(P < 0.05). No differences were recorded for the pulse wave Doppler ultrasound parameters in young bulls compared with adults. A significant correlation was found between the resistive index of the marginal portion of the testicular artery and total sperm in the ejaculate(r = 0.516, P < 0.05), the immature sperm(r = 0.462, P < 0.05), the teratoid sperm(r = 0.375, P < 0.05), and the "Dag defect" sperm(r = 0.389, P < 0.05). Similarly, the resistive index of the intratesticular branches of the testicular artery were found correlated with the total sperm number in the ejaculate(r = 0.568, P < 0.05), the immature sperm(r = 0.523, P < 0.05), the teratoid sperm(r = 0.418, P < 0.05), and the "Dag defect" sperm(r = 0.341, P < 0.05).Conclusions: The data presented in this study suggest that the resistive index, measured at the marginal portion of the testicular artery, could be an easy-to-perform parameter to evaluate the spermatogenesis quality in young bulls and normal adults.展开更多
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu...The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.展开更多
Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. ...Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. Out of 120 patients, 106 (88.3%) female and 14 (11.7%) male patients. Out of 106 female patients, 64 (91.45) had benign and 42 had malignant thyroid nodules. Out of 14 (11.7) male patients, 6 had benign and 8 had malignant thyroid nodules. The youngest patient in our study was 31 years and the oldest patient was 76 years. The common range of patients age was ≥ 60 years and consisting of twenty (28.6%) benign thyroid nodules and fourteen (28%) malignant thyroid nodules. The majority of patients’ age group with malignant thyroid nodules were between 50 - 60 years and consisting of twenty (40%) malignant nodules. In our study, according to the result of gray scale and color Doppler ultrasonography, hypo-echogenicity, solid echo structure, micro-calcification and intra-nodular vascularity were the significant characteristics of malignancy in nodules with sensitivity (72%, 74%, 48% and 88% respectively), specificity (66%, 63%, 94% and 69% respectively), PPV (60%, 59%, 86% and 67% respectively) and NPV (77%, 77%, 72% and 89% respectively).展开更多
Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infert...Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited. Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection. Group A, endometrial and subendometrial blood flows were 2 branches and below; group B, endometrial and subendometrial blood flows were between 3 and 4 branches; group C, endometrial and subendometrial blood flows were 5 branches and above. Patients were transferred 1-3 embryos each. Demographic data, ovarian responses, endometrial thickness, PI, RI, development of embryo and IVF result among groups were compared. Results Demographic data, ovarian responses, endometrial thickness, PI, RI and development of embryo among groups have no significant difference. The pregnancy rate of group A was significantly lower than that of group B (P〈0.05) and group C (P〈0.01). The implantation rate of group A was significantly lower than than of group C (P〈0.01). There was no significant difference of the rate of pregnancy and implantation between group B and group C (P〉0.05). Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment. A good endometrial and subendometrial blood flows is benefit for the result of IVF.展开更多
Accurate assessment of the hemodynamic status is vital for appropriate management of patients with critical illness.As such,there has been a constant quest for reliable and non-invasive bedside tools to assess and mon...Accurate assessment of the hemodynamic status is vital for appropriate management of patients with critical illness.As such,there has been a constant quest for reliable and non-invasive bedside tools to assess and monitor circulatory status in order to ensure end-organ perfusion.In the recent past,point of care ultrasonography(POCUS)has emerged as a valuable adjunct to physical examination in various specialties,which basically is a clinician-performed bedside ultrasound to answer focused questions.POCUS allows visualization of the internal anatomy and flow dynamics in real time,guiding apt interventions.While both arterial(forward flow)and venous(organ outflow or afterload)limbs of hemodynamic circuit are important for tissue perfusion,the venous side remains relatively under-explored.With recent data underscoring the deleterious consequences of iatrogenic volume overload,objective evaluation of venous congestion is gaining attention.Bedside Doppler ultrasound serves this purpose and aids in diagnosing and monitoring the congestion/venous blood flow pattern.In this article,we summarize the rationale for integrating this technology into routine care of patients with volume-related disorders,discuss the normal and abnormal waveforms,limitations,and future directions.展开更多
Background: Diabetic foot is a frequent complication of diabetes, of multifactorial origin, associating nervous and/or circulatory disorders to which infection is often added. Its care is multidisciplinary and require...Background: Diabetic foot is a frequent complication of diabetes, of multifactorial origin, associating nervous and/or circulatory disorders to which infection is often added. Its care is multidisciplinary and requires coordination between different actors. In this context, arterial doppler ultrasound is essential in the diagnosis of diabetic arteriopathy and participates in therapeutic decision-making. The aim of this study was to describe the abnormalities found on Doppler ultrasonography of patients hospitalized for the diabetic foot in the Ivory Coast. Methods: We conducted a retrospective descriptive study including 235 patients hospitalized for the diabetic foot in the Endocrinology department of the Yopougon University Hospital from February 2002 to December 2015. All records of patients who performed arterial Doppler ultrasound of the lower limbs were selected and the various abnormalities were described. Results: The sex ratio (M/F) was 1.1 (124 men to 111 women). The predominant age group was 61.2 years. Type 2 diabetes was found in 97.4% of cases. The average evolution of diabetes was 8.9 years with extremes of 1 and 32 years. Wet gangrene was the most common type of lesion found in 75.8% of cases. On ultrasonography, 98.7% of the patients had an arterial abnormality of the lower limbs. It was bilateral in 62.2% of cases, dominated by atheromatous overloads and mediacalcosis in 46.4% and 43.8% of cases, respectively. Arterial stenosis was lesions hemodynamically found in 76.3% of cases and arterial occlusions in 32.7% of cases. The amputation rate was 72.7%. Conclusion: This study shows the high frequency of arterial abnormalities in patients with the diabetic foot with a predominantly distal involvement. Arterial Doppler ultrasound of the lower limbs remains an essential tool in the care of diabetic foot. This easily accessible, non-invasive examination has a key role in therapeutic decision-making.展开更多
Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017...Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017 to March 2018 were selected for study. All patients underwent color Doppler ultrasound diagnosis. According to the diagnostic data, benign thyroid nodules and thyroid cancer were analyzed. The nodule nature was grouped into benign nodules group and malignant nodules group. The aspect ratio and boundary of the two groups were compared in blurring, calcification, blood flow signal classification, etc. Results: A total of 95 nodules were diagnosed by color doppler ultrasonography in 60 cases of thyroid nodules. 49 cases were benign nodules. There were 80 nodules, accounting for 82.11%, 11 cases of thyroid cancer, and 15 nodules. Accounted for 15.79%. Biopsy puncture pathology confirmed 77 benign nodules and 18 malignant nodules. The pathological results were gold standard. The specificity of color Doppler ultrasound was 90%, the sensitivity was 66.67%, and the accuracy of ultrasound diagnosis was 86.32%.The two nodules were statistically significant in terms of boundary, aspect ratio, calcification, echo, and resistance index (P<0.05), but the end-diastolic blood flow velocity (EDV) and peak systolic blood flow velocity ( There was no statistical difference between the PSV levels (P>0.05).Conclusion: Color Doppler ultrasound has the advantages of simple operation, high accuracy, non-invasive and painless, and reproducible detection. The high-frequency probe can clearly display changes such as minute lesions, blood flow signals, echoes, calcifications, etc., and can diagnose thyroid cancer in time. It provides a favorable basis for clinical treatment and has important clinical warning value, especially for children with thyroid examination.展开更多
文摘Objective:The clinical grading system for varicoceles is subjective and dependent on clinician experience.Color Doppler ultrasound(US)has not been standardized in the diagnosis of varicoceles.We aimed to determine if US measurement of varicocele could be predictive of World Health Organization(WHO)varicocele grade.Methods:Men who presented for either scrotal pain or infertility to a tertiary men’s health clinic underwent physical examination,and varicoceles were graded following WHO criteria(0Zsubclinical,1,2,3).US was used to measure largest venous diameter in the pampiniform plexus bilaterally at rest and during Valsalva maneuver.Receiver operator characteristic curve analysis was used to determine if resting diameter,diameter during Valsalva,or change in diameter between at rest and during Valsalva provided the highest sensitivity and specificity for determining clinical grade.Threshold values for diameter were determined from these receiver operator characteristic curves.Results:A total of 102 men(50 with clinical varicocele and 52 with subclinical varicocele)were included.Diameter at rest was the best ultrasonographic discriminator between subclinical and clinical varicoceles(area under the curve[AUC]Z0.67)with a diameter threshold of 3.0 mm(sensitivity 79%,specificity 42%).Diameter during Valsalva had the greatest AUC for determining clinical Grades 1 versus 2(AUCZ0.57)with diameter threshold of 5.7 mm(sensitivity 71%,specificity 33%).For differentiating between Grades 2 and 3,diameter at rest had the greatest AUC of 0.65 with a threshold of 3.6 mm(sensitivity 71%,specificity 58%).Conclusion:Our results corroborate other studies that have shown a weak correlation between US and clinical grading.The use of diameter during Valsalva was less predictive than diameter at rest and was only clinically significant in differentiating between Grade 1 and 2 varicocele.A standardized method for determining clinically relevant varicoceles on US would allow for improved patient counseling and clinical decision-making.
文摘The World Journal of Cardiology published an article written by Kuwahara et al that we take the pleasure to comment on.We focused our attention on venous congestion.In intensive care settings,it is now widely accepted that venous congestion is an important clinical feature worthy of investigation.Evaluating venous Doppler profile abnormalities at multiple sites could suggest adequate treatment and monitor its efficacy.Renal dysfunction could trigger or worsen fluid overload in heart disease,and cardio-renal syndrome is a well-characterized spectrum of disorders describing the complex interactions between heart and kidney diseases.Fluid overload and venous congestion,including renal venous hypertension,are major determinants of acute and chronic renal dysfunction arising in heart disease.Organ congestion from venous hypertension could be involved in the development of organ injury in several clinical situations,such as critical diseases,congestive heart failure,and chronic kidney disease.Ultrasonography and abnormal Doppler flow patterns diagnose clinically significant systemic venous congestion.Cardiologists and nephrologists might use this valuable,noninvasive,bedside diagnostic tool to establish fluid status and guide clinical choices.
文摘AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG.
基金Konkuk University Medical Center Research Grant 2018.
文摘BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagogastroduodenoscopy(EGD)and high-frequency intraluminal ultrasound(HFIUS)for type 1 gastric varices(GOV1)after EVL and to identify the predictability for rebleeding of EGD and HFIUS.METHODS In liver cirrhosis patients with GOV1,we performed endoscopic follow-up using EGD and HFIUS synchronously after EVL for hemorrhage from GOV1.Endoscopic grading and red color signs were analyzed using EGD,and the largest variceal cross-sectional areas were measured using HFIUS.In addition,1-year follow-up was performed.Variceal rebleeding was defined as the presence of hematemesis,hematochezia,or melena without other evidence of bleeding on endoscopic follow-up.RESULTS In 26 patients with GOV1,variceal cross-sectional areas on HFIUS of GOV1 was poorly correlated with EGD grading of GOV1(r=0.36).In 17 patients who completed the 1-year follow-up,variceal cross-sectional areas on HFIUS was a good predictor of subsequent rebleeding,whereas EGD grading was not a predictor of subsequent rebleeding.CONCLUSION HFIUS measurement is more predictive of GOV1 rebleeding than EGD grading,so HFIUS measurement may be necessary for endoscopic follow-up after EVL in patients with GOV1.
文摘<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types.
文摘Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties.
文摘High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.
基金National natural science foundation of China(No.81701891)Guided scientific research project of Shiyan science and technology bureau(No.18Y63)。
文摘Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clinical medication and evaluation of therapeutic effect.Methods:From December 2018 to December 2019,110 patients with DPN who met the inclusion and exclusion criteria were divided into observation group and control group according to different treatment plans.The control group was treated withα-lipoic acid,and the observation group was treated withα-lipoic acid combined with traditional Chinese medicine encapsulation treatment,and used high-frequency ultrasound,nerve conduction velocity and serological examination to comprehensively evaluate the effectiveness of the two treatment methods.Results:The mean amplitude of glycemic excursions(MAGE)value of the observation group and the control group after treatment was significantly lower than before treatment(P<0.05);After treatment,the SCV of the ulnar nerve,median nerve,and common peroneal nerve in the two groups was significantly faster than before treatment(P<0.05).Similar to SCV,the MCV of the three nerves measured after treatment in the two groups was significantly faster than before treatment(P<0.05).Compared between the groups after treatment,the three kinds of nerve SCV and MCV in the observation group were significantly faster than those in the control group(P<0.05).The cross-sectional area(CSA)value of the ulnar nerve,median nerve and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).Compared with the control group after treatment,the three nerves CSA in the observation group was significantly lower than that in the control group(P<0.05).Abnormal ultrasound performance:The proportion of abnormal ultrasound performances of the ulnar nerve,median nerve,and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).The composition ratio of internal echo reduction and ambiguity in the observation group after three nerve treatments was significantly lower than that in the control group after treatment(P<0.05).In the correlation analysis,the three kinds of nerve CSA before and after treatment were negatively correlated with SCV and amplitude(P<0.05),and positively correlated with latency(P<0.05).Conclusion:The combination ofα-lipoic acid and Chinese medicine encapsulation technology has a good effect on the treatment and repair of DPN nerve damage,and can be routinely applied in clinical treatment.High-frequency ultrasound can intuitively observe changes in peripheral nerves and can be used to evaluate the prognosis of DPN.
文摘Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in hand and foot were retrospectively analyzed,including the location,size,shape,boundary,internal echo and posterior echo,surrounding relationship and blood flow.Results:Among 65 cases,there were 26 cases of tendon sheath cyst,16 cases of tenosynovitis giant cell tumor,10 cases of hemangioma,4 cases of tendon sheath fibroma,3 cases of epidermoid cyst,2 cases of Schwannoma,2 cases of fibrolipoma,1 case of angiolipoma and 1 case of neurofibroma.The preoperative and postoperative pathological diagnoses of 45 cases,accounting for 69.23%,were consistent,3 cases(4.62%)were misdiagnosed,which included that 2 cases of tenosynovitis giant cell tumor were misdiagnosed as tendon sheath cyst,1 case of neurofibroma as epidermoid cyst,and the preoperative diagnosis of the rest 17 cases(26.15%)were indefinite.Conclusion:The high-frequency ultrasound can diagnose properties of lumps in foot and hand well,providing diagnosis basis for further treatment in clinic.
基金Supported by the Natural Science Foundation of Shanghai, No. 034119921
文摘AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding.
文摘The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tumors were enrolled in this study.After intravenous administration of levovist,the color Doppler signals of normal hepatic vessels were enhanced.In various hepatic tumors,the different patterns of tumor vascularity were observed,which had not been demonstrated in conventional non contrast color Doppler imaging.In 11 of 16 patients with hepatocarcinoma,additional color Doppler signals were observed in the central part of the tumors.On the contrary,3 patients with metastatic liver lesions the enhanced color Doppler signals appear only at the peripheral of tumors.A typical rim like color enhancement was seen in 2 of the 3 cases.In six patients with hepatic hemangiomas contrast enhanced color Doppler imaging demonstrated the blood vessels at the margin of the neoplasms.Contrast enhanced color Doppler imaging improves the visualization of the hepatic neoplasm vascularity.This technique holds great promise for detecting small liver tumors and differentiating hepatic neoplasms.
基金Supported by grants of the National Natural Science of China(No.81000700No.81573072)
文摘Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler ultrasound guidance in choosing the optimal treatment modality. Methods Infantile patients who were clinical diagnosed as hemangiomas were randomly divided into group A, who had color Doppler ultrasound examinations before the treatment, and group B who had the treatment without ultrasound evaluation. Patients in the group A were assigned into subgroups according to the depth of lesion by sonography: group A-1 for those who had a lesion depth 〈1.2 mm, and took intense pulsed light therapy; group A-2 for those who had a lesion depth ≥1.2mm and 〈 3 mm, and took long pulse 1064 nm Nd:YAG laser therapy; group A-3 for those who had a lesion depth ≥3mm and 〈5 mm, and were treated by IPL combined with long pulse 1064 nm Nd:YAG laser treatment; Group A-4 for those who had a lesion depth ≥5 mm, and took lauromacrogol injection therapy. Patients in the group B took long pulse 1064 nm Nd:YAG laser treatment without preoperative ultrasound evaluation. The efficacy and adverse reactions of the treatments between the groups were evaluated and compared statistically. Results Totally 113 patients with 128 skin lesions were enrolled in this study, 85 in the group A (mean age 6.8±7.9 months) and 28 in the group B (mean age 6.9±9.9 months). The mean depth of hemangioma was 3.3±1.1 mm in the group A, ranging from 0.5-7.8 mm, with 0.8±0.4 mm, 2.2±0.4 mm, 4.2±0.6 mm and 6.2±0.7 mm in group A1, A2, A3 and A4, respectively. The cure rates and effective rates in the group A were significantly higher than those in the group B (cure rates: 64.5% vs 56.3%, U=3.378, P=0.045; effective rates: 89.5% vs 78.1%, U=4.163, P=0.041). The adverse effect rates of the group A (vesicle 20.0%, pigmentation 46.9%, scarring 17.7%) were lower than those of the group B (vesicle 21.9%, pigmentation 60.4%, scarring 25.0%). Incidences of pigmentation and scarring were statistically significantly different (U=3.884, P=0.034, and U=4.016, P=0.032 respectively) between the two groups. Conclusion With the guidance of color Doppler ultrasound, the efficacy and safety of long pulse 1064 nmNd:YAG laser, intense pulsed light, and lauromacrogol injection in the treatment of infantile hemangioma have better outcomes compared to laser treatment alone without preoperative ultrasound examination.
文摘Purpose: Intrapartum Doppler velocimetry is a non-invasive investigation method. This method is useful for evaluating the pathophysiological mechanisms underlying changes in fetal heart rate. This study aimed to determine the usefulness of Doppler ultrasound findings during labor in high-risk women on determining the mode of delivery and outcome of the newborn. Methods: A cross-sectional study was conducted from January 1, 2015 to December 31, 2015 on 100 high-risk pregnant women during labor. The study was performed in the Maternity Teaching Hospital in Erbil City, Kurdistan Region, Iraq. Results: The majority of women (77%) had a normal end-diastolic blood flow pattern through the umbilical artery. A total of 76.9% of those with abnormal Doppler results had a Cesarean delivery compared with only 9.5% of those with normal Doppler results (p p p = 0.07) and fifth minutes (p = 0.01). Conclusions: Abnormal umbilical artery Doppler ultrasound findings in high-risk pregnancies for women in labor are associated with increased rates of emergency cesarean sections and a poor outcome of the newborn.
基金the Provincial Breeders Federation of Trento for their support
文摘Background: Semen evaluation is used to estimate the testicular function. In bulls, the spermatozoa present in the ejaculate are the result of a process that begun more than 2 mo earlier, bequeathing a delayed depiction of the actual function of the testis. Since testis vascularization might be critical for the gonad function, selected pulse wave Doppler ultrasound parameters were assessed in this study, for instance the peak systolic velocity, the end diastolic velocity and the resistive index of the testicular artery along the spermatic cord, the marginal portion of the testicular artery and the intratesticular branches of the testicular artery both in healthy adult and young bulls.Correlations between these parameters and characteristics of semen that was collected numerous times, before and after the Doppler ultrasound examination.Results: The peak systolic velocity and the end diastolic velocity measured in the testicular artery along the spermatic cord(supratesticular artery – SA) were variable among the bulls and within individual bulls, likely due to the convoluted course of the vessel. The resistive index was found highly repeatable in the same bull. A reduction in the resistive index was found between the supratesticular artery and the marginal portion of the testicular artery(P < 0.01), and between the marginal portion of the testicular artery and the intratesticular branches of the testicular artery(P < 0.05). No differences were recorded for the pulse wave Doppler ultrasound parameters in young bulls compared with adults. A significant correlation was found between the resistive index of the marginal portion of the testicular artery and total sperm in the ejaculate(r = 0.516, P < 0.05), the immature sperm(r = 0.462, P < 0.05), the teratoid sperm(r = 0.375, P < 0.05), and the "Dag defect" sperm(r = 0.389, P < 0.05). Similarly, the resistive index of the intratesticular branches of the testicular artery were found correlated with the total sperm number in the ejaculate(r = 0.568, P < 0.05), the immature sperm(r = 0.523, P < 0.05), the teratoid sperm(r = 0.418, P < 0.05), and the "Dag defect" sperm(r = 0.341, P < 0.05).Conclusions: The data presented in this study suggest that the resistive index, measured at the marginal portion of the testicular artery, could be an easy-to-perform parameter to evaluate the spermatogenesis quality in young bulls and normal adults.
文摘The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.
文摘Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. Out of 120 patients, 106 (88.3%) female and 14 (11.7%) male patients. Out of 106 female patients, 64 (91.45) had benign and 42 had malignant thyroid nodules. Out of 14 (11.7) male patients, 6 had benign and 8 had malignant thyroid nodules. The youngest patient in our study was 31 years and the oldest patient was 76 years. The common range of patients age was ≥ 60 years and consisting of twenty (28.6%) benign thyroid nodules and fourteen (28%) malignant thyroid nodules. The majority of patients’ age group with malignant thyroid nodules were between 50 - 60 years and consisting of twenty (40%) malignant nodules. In our study, according to the result of gray scale and color Doppler ultrasonography, hypo-echogenicity, solid echo structure, micro-calcification and intra-nodular vascularity were the significant characteristics of malignancy in nodules with sensitivity (72%, 74%, 48% and 88% respectively), specificity (66%, 63%, 94% and 69% respectively), PPV (60%, 59%, 86% and 67% respectively) and NPV (77%, 77%, 72% and 89% respectively).
文摘Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited. Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection. Group A, endometrial and subendometrial blood flows were 2 branches and below; group B, endometrial and subendometrial blood flows were between 3 and 4 branches; group C, endometrial and subendometrial blood flows were 5 branches and above. Patients were transferred 1-3 embryos each. Demographic data, ovarian responses, endometrial thickness, PI, RI, development of embryo and IVF result among groups were compared. Results Demographic data, ovarian responses, endometrial thickness, PI, RI and development of embryo among groups have no significant difference. The pregnancy rate of group A was significantly lower than that of group B (P〈0.05) and group C (P〈0.01). The implantation rate of group A was significantly lower than than of group C (P〈0.01). There was no significant difference of the rate of pregnancy and implantation between group B and group C (P〉0.05). Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment. A good endometrial and subendometrial blood flows is benefit for the result of IVF.
文摘Accurate assessment of the hemodynamic status is vital for appropriate management of patients with critical illness.As such,there has been a constant quest for reliable and non-invasive bedside tools to assess and monitor circulatory status in order to ensure end-organ perfusion.In the recent past,point of care ultrasonography(POCUS)has emerged as a valuable adjunct to physical examination in various specialties,which basically is a clinician-performed bedside ultrasound to answer focused questions.POCUS allows visualization of the internal anatomy and flow dynamics in real time,guiding apt interventions.While both arterial(forward flow)and venous(organ outflow or afterload)limbs of hemodynamic circuit are important for tissue perfusion,the venous side remains relatively under-explored.With recent data underscoring the deleterious consequences of iatrogenic volume overload,objective evaluation of venous congestion is gaining attention.Bedside Doppler ultrasound serves this purpose and aids in diagnosing and monitoring the congestion/venous blood flow pattern.In this article,we summarize the rationale for integrating this technology into routine care of patients with volume-related disorders,discuss the normal and abnormal waveforms,limitations,and future directions.
文摘Background: Diabetic foot is a frequent complication of diabetes, of multifactorial origin, associating nervous and/or circulatory disorders to which infection is often added. Its care is multidisciplinary and requires coordination between different actors. In this context, arterial doppler ultrasound is essential in the diagnosis of diabetic arteriopathy and participates in therapeutic decision-making. The aim of this study was to describe the abnormalities found on Doppler ultrasonography of patients hospitalized for the diabetic foot in the Ivory Coast. Methods: We conducted a retrospective descriptive study including 235 patients hospitalized for the diabetic foot in the Endocrinology department of the Yopougon University Hospital from February 2002 to December 2015. All records of patients who performed arterial Doppler ultrasound of the lower limbs were selected and the various abnormalities were described. Results: The sex ratio (M/F) was 1.1 (124 men to 111 women). The predominant age group was 61.2 years. Type 2 diabetes was found in 97.4% of cases. The average evolution of diabetes was 8.9 years with extremes of 1 and 32 years. Wet gangrene was the most common type of lesion found in 75.8% of cases. On ultrasonography, 98.7% of the patients had an arterial abnormality of the lower limbs. It was bilateral in 62.2% of cases, dominated by atheromatous overloads and mediacalcosis in 46.4% and 43.8% of cases, respectively. Arterial stenosis was lesions hemodynamically found in 76.3% of cases and arterial occlusions in 32.7% of cases. The amputation rate was 72.7%. Conclusion: This study shows the high frequency of arterial abnormalities in patients with the diabetic foot with a predominantly distal involvement. Arterial Doppler ultrasound of the lower limbs remains an essential tool in the care of diabetic foot. This easily accessible, non-invasive examination has a key role in therapeutic decision-making.
文摘Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017 to March 2018 were selected for study. All patients underwent color Doppler ultrasound diagnosis. According to the diagnostic data, benign thyroid nodules and thyroid cancer were analyzed. The nodule nature was grouped into benign nodules group and malignant nodules group. The aspect ratio and boundary of the two groups were compared in blurring, calcification, blood flow signal classification, etc. Results: A total of 95 nodules were diagnosed by color doppler ultrasonography in 60 cases of thyroid nodules. 49 cases were benign nodules. There were 80 nodules, accounting for 82.11%, 11 cases of thyroid cancer, and 15 nodules. Accounted for 15.79%. Biopsy puncture pathology confirmed 77 benign nodules and 18 malignant nodules. The pathological results were gold standard. The specificity of color Doppler ultrasound was 90%, the sensitivity was 66.67%, and the accuracy of ultrasound diagnosis was 86.32%.The two nodules were statistically significant in terms of boundary, aspect ratio, calcification, echo, and resistance index (P<0.05), but the end-diastolic blood flow velocity (EDV) and peak systolic blood flow velocity ( There was no statistical difference between the PSV levels (P>0.05).Conclusion: Color Doppler ultrasound has the advantages of simple operation, high accuracy, non-invasive and painless, and reproducible detection. The high-frequency probe can clearly display changes such as minute lesions, blood flow signals, echoes, calcifications, etc., and can diagnose thyroid cancer in time. It provides a favorable basis for clinical treatment and has important clinical warning value, especially for children with thyroid examination.