期刊文献+
共找到20,689篇文章
< 1 2 250 >
每页显示 20 50 100
Kinematic deformation and intensity assessment of the 2021 Maduo M_(S)7.4 earthquake in Qinghai revealed by high-frequency GNSS
1
作者 Yu Li Yuebing Wang +2 位作者 Lijiang Zhao Hongbo Shi Pingping Wang 《Geodesy and Geodynamics》 EI CSCD 2024年第3期230-240,共11页
Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advance... Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advancement of GNSS observation and data processing makes it play an important role in this field,especially the high-frequency GNSS.We used the differential positioning method to calculate the 1 HZ GNSS data from 98 sites within 1000 km of the M_(S)7.4 Maduo earthquake epicenter.The kinematic deformation field and the distribution of the seismic intensity by using the peak ground velocity derived from displacement waveforms were obtained.The results show that:1)Horizontal coseismic response deformation levels ranging from 25 mm to 301 mm can be observed within a 1000 km radius from the epicenter.Coseismic response deformation on the east and west sides shows bilateral asymmetry,which markedly differs from the symmetry presented by surface rupture.2)The seismic intensity obtained through high-frequency GNSS and field investigations exhibits good consistency of the scope and orientation in the high seismic intensity area,although the former is generally slightly smaller than the latter.3)There may exist obstacles on the eastern side of the seismogenic fault.The Maduo earthquake induced a certain tectonic stress loading effect on the western Kunlun Pass-Jiangcuo fault(KPJF)and Maqin-Maqu segment,resulting in higher seismic risk in the future. 展开更多
关键词 Maduo earthquake high-frequency GNSS Kinematic deformation Seismic intensity
下载PDF
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
2
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
下载PDF
Review of the Analysis and Suppression for High-frequency Oscillations of the Grid-connected Wind Power Generation System
3
作者 Bo Pang Qi Si +4 位作者 Pan Jiang Kai Liao Xiaojuan Zhu Jianwei Yang Zhengyou He 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期127-142,共16页
High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is... High-frequency oscillation(HFO)of gridconnected wind power generation systems(WPGS)is one of the most critical issues in recent years that threaten the safe access of WPGS to the grid.Ensuring the WPGS can damp HFO is becoming more and more vital for the development of wind power.The HFO phenomenon of wind turbines under different scenarios usually has different mechanisms.Hence,engineers need to acquire the working mechanisms of the different HFO damping technologies and select the appropriate one to ensure the effective implementation of oscillation damping in practical engineering.This paper introduces the general assumptions of WPGS when analyzing HFO,systematically summarizes the reasons for the occurrence of HFO in different scenarios,deeply analyses the key points and difficulties of HFO damping under different scenarios,and then compares the technical performances of various types of HFO suppression methods to provide adequate references for engineers in the application of technology.Finally,this paper discusses possible future research difficulties in the problem of HFO,as well as the possible future trends in the demand for HFO damping. 展开更多
关键词 Damping method high-frequency oscillation STABILITY Wind power generation
下载PDF
Efficient activation of the Co/SBA-15catalyst by high-frequency AC-DBD plasma thermal effects for toluene removal
4
作者 李越 姜楠 +5 位作者 刘政妍 秦亮 彭邦发 王荣刚 孙玉荣 李杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期84-94,共11页
Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated d... Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated during the discharge process leads to energy waste and low energy utilization efficiency.In this work,an innovative DBD thermally-conducted catalysis(DBD-TCC)system,integrating high-frequency AC-DBD plasma and its generated thermal effects to activate the Co/SBA-15 catalyst,was employed for toluene removal.Specifically,Co/SBA-15 catalysts are closely positioned to the ground electrode of the plasma zone and can be heated and activated by the thermal effect when the voltage exceeds 10 k V.At12.4 k V,the temperature in the catalyst zone reached 261℃ in the DBD-TCC system,resulting in an increase in toluene degradation efficiency of 17%,CO_(2)selectivity of 21.2%,and energy efficiency of 27%,respectively,compared to the DBD system alone.In contrast,the DBD thermally-unconducted catalysis(DBD-TUC)system fails to enhance toluene degradation due to insufficient heat absorption and catalytic activation,highlighting the crucial role of AC-DBD generated heat in the activation of the catalyst.Furthermore,the degradation pathway and mechanism of toluene in the DBD-TCC system were hypothesized.This work is expected to provide an energy-efficient approach for high-frequency AC-DBD plasma removal of VOCs. 展开更多
关键词 high-frequency alternating-current power thermal effect dielectric barrier discharge toluene degradation Co/SBA-15 catalysts
下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
5
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
下载PDF
Radio-frequency measurements of energetic-electron-driven emissions using high-frequency magnetic probe on XuanLong-50 spherical torus
6
作者 王明远 伦秀春 +3 位作者 薄晓坤 刘兵 刘阿娣 石跃江 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期33-38,共6页
A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and dat... A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and data acquisition system of the probe are comprehensively examined.The fluctuation data from the EXL-50 plasma are analyzed in the time–frequency domain using fast Fourier transforms.Moreover,distinct high-frequency instabilities are detected using this diagnostic system.In particular,significant frequency chirping is observed,which is consistent with the bumpon-tail drive instability predicted using the Berk–Breizman model. 展开更多
关键词 high-frequency magnetic probe high-frequency instabilities XuanLong-50
下载PDF
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss
7
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
下载PDF
英汉笔译课程PROBE教学模式探究
8
作者 陈严春 《忻州师范学院学报》 2024年第2期114-118,共5页
作为本科翻译专业的一门核心课程,英汉笔译课程在培养学生英汉双语运用能力、翻译能力和跨文化能力,尤其是学生英译汉翻译实践能力作用明显。文章对“PROBE教学模式”进行概念诠释,从教学目标、课程设计、教学过程和学习评价四个方面探... 作为本科翻译专业的一门核心课程,英汉笔译课程在培养学生英汉双语运用能力、翻译能力和跨文化能力,尤其是学生英译汉翻译实践能力作用明显。文章对“PROBE教学模式”进行概念诠释,从教学目标、课程设计、教学过程和学习评价四个方面探讨了“PROBE教学模式”在英汉笔译课程中的应用,最后提出几点建议,以期提高英汉笔译课程的教学效果。 展开更多
关键词 英汉笔译 probe教学模式 教学效果
下载PDF
A Probe into Learners'Colligational Use of High-frequency Verbs
9
作者 李新利 《海外英语》 2011年第10X期339-342,共4页
This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the... This study attempts to examine the colligational use of the high-frequency verbs DO, HAVE and BE in Chinese EFL learners'written production in the CIA (Contrastive Interlanguage Analysis) approach. Findings of the study indicate that: Chinese learners use a much smaller variety of colligational patterns, they tend to underuse the inflected forms of these verbs in their colligations and they tend to use pronouns as the subject of these verbs. Though at advanced level, they still have difficulty with grammar in terms of tense, aspect and voice. The influence of L1 transfer, the learners'spoken style in writing, the classroom teaching and the learners'use of the avoidance strategy are thought to be the major reasons. The findings in this study may have some light to shed on the EFL teaching and research in China. 展开更多
关键词 high-frequency VERBS colligations CIA
下载PDF
Tuning magneto-dielectric properties of Co_(2)Z ferrites via Gd doping for high-frequency applications
10
作者 武剑 卢冰 +6 位作者 张颖 陈一鑫 孙凯 陈大明 李强 刘颖力 李颉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期468-473,共6页
Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,an... Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,and 0.20)materials are successfully prepared by using solid-state method at 925℃for 4 h with 2.5-wt%Bi_(2)O_(3)sintering aids.The content of Gd^(3+)ion can affect micromorphology,grain size,bulk density,and magneto-dielectric properties of the ferrite.With Gd^(3+)ion content increasing,saturation magnetization(Ms)first increases and then decreases.The maximum value of Ms is 44.86 emu/g at x=0.15.Additionally,sites occupied by Gd^(3+)ions can change magnetic anisotropy constant of the ferrite.Magnetocrystalline anisotropy constant(K_1)is derived from initial magnetization curve,and found to be related to spin-orbit coupling and intersublattice interactions between metal ions.The real part of magnetic permeability(μ′)and real part of dielectric permittivity(ε′)are measured in a frequency range of 10 MHz-1 GHz.When x=0.15,material has excellent magneto-dielectric properties(μ′≈12.2 andε′≈17.61),low magnetic loss(tanδμ≈0.03 at 500 MHz),and dielectric loss(tanδε≈0.04 at 500 MHz).The results show that Gd-doped Co_(2)Z ferrite has broad application prospects in multilayer filters and high-frequency antennas. 展开更多
关键词 Co_(2)Z ferrite magneto-dielectric properties Gd doping high-frequency applications
下载PDF
Measurement of Ion Cyclotron Emissions by Using High-Frequency Magnetic Probes in the LHD
11
作者 Kenji SAITO Ryuhei KUMAZAWA +13 位作者 Tetsuo SEKI Hiroshi KASAHARA Goro NOMURA Fujio SHIMPO Hiroe IGAMI Mitsutaka ISOBE Kunihiro OGAWA Kazuo TOI Masaki OSAKABE Masaki NISHIURA Tsuguhiro WATANABE Satoshi YAMAMOTO Makoto ICHIMURA Takashi MUTOH 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第3期209-212,共4页
Two pairs of high-frequency magnetic probes were installed in the Large Helical Device (LHD). During the injection of a perpendicular neutral beam, ion cyclotron emissions (ICEs) with the fundamental frequency cor... Two pairs of high-frequency magnetic probes were installed in the Large Helical Device (LHD). During the injection of a perpendicular neutral beam, ion cyclotron emissions (ICEs) with the fundamental frequency corresponding to the ion cyclotron frequency at the plasma edge were detected, which are the same type of ICE as measured with the former spare ion cyclotron range of frequencies (ICRF) heating antennas. This type of ICE was further investigated with regard to the phase and intensity of signals. Another type of ICE was found in the LHD, and these ICEs were synchronized with bursts of toroidicity induced Alfv^n eigenmodes (TAE) and the rise of intensity of lost ion flux. Therefore the source of these ICEs was thought to be the particles transferred from the core to the outer region of plasma by the TAE bursts. The frequency of ICEs induced by the TAE bursts increases linearly with the magnetic field strength, since the ion cyclotron frequency increases with the magnetic field strength. 展开更多
关键词 LHD ICE TAE lost particle high-frequency magnetic probe
下载PDF
An exo Probe-based Reverse Transcription and Recombinase Polymerase Amplification for Rapid Detection of Feline Calicivirus in Cats
12
作者 MU Hong Yun ZHOU Hong Lei +2 位作者 JING Zheng LU Wei ZHANG Jian Wei 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2024年第3期325-330,共6页
Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper... Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper respiratory tract disease(URTD)and virulent systemic disease(FCV-VSD)[1].Infected cats usually presented with mouth ulcers,salivation and gingivitis-stomatitis.Furthermore,both recovered cats and asymptomatic carriers can still carry and spread the FCV virus for extended periods of time,contributing to the potential for outbreak.This presented a significant threat to the health and lives of cats,and rare wildlife and took a heavy financial loss on the pet industry,making the prevention and control of the virus difficult.Hence,rapid identification of FCV in clinical samples was necessary to prevent the spread of FCV and avoid financial loss. 展开更多
关键词 prevention RESPIRATORY probe
下载PDF
Activatable fluorescent probes for imaging and diagnosis of rheumatoid arthritis
13
作者 Pan Luo Fu-Qiang Gao +5 位作者 Wei Sun Jun-You Li Cheng Wang Qing-Yu Zhang Zhi-Zhuo Li Peng Xu 《Military Medical Research》 SCIE CAS CSCD 2024年第2期287-307,共21页
Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affec... Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affecting locomotion ability and life quality.Consequently,good prognosis heavily relies on the early diagnosis and effective therapeutic monitoring of RA.Activatable fluorescent probes play vital roles in the detection and imaging of biomarkers for disease diagnosis and in vivo imaging.Herein,we review the fluorescent probes developed for the detection and imaging of RA biomarkers,namely reactive oxygen/nitrogen species(hypochlorous acid,peroxynitrite,hydroxyl radical,nitroxyl),pH,and cysteine,and address the related challenges and prospects to inspire the design of novel fluorescent probes and the improvement of their performance in RA studies. 展开更多
关键词 Rheumatoid arthritis Fluorescent probe IMAGING DIAGNOSIS BIOMARKER
下载PDF
Plasma potential measurements using an emissive probe made of oxide cathode
14
作者 李建泉 马海杰 陆文琪 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期571-577,共7页
A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparis... A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparison with a traditional tungsten emissive probe,including the operating temperature,the electron emission capability and the plasma potential measurement.Studies of the operating temperature and electron emission capability show that the tungsten emissive probe usually works at a temperature of 1800 K-2200 K while the oxide cathode emissive probe can function at about 1200 K-1400 K.In addition,plasma potential measurements using the oxide cathode emissive probe with different techniques have been accomplished in microwave electron cyclotron resonance plasmas with different discharge powers.It is found that a reliable plasma potential can be obtained using the improved inflection point method and the hot probe with zero emission limit method,while the floating point method is invalid for the oxide cathode emissive probe. 展开更多
关键词 emissive probe oxide cathode plasma potential filament temperature
下载PDF
Design of compact integrated diamond nitrogen-vacancy center quantum probe
15
作者 夏圣开 卢文韬 +10 位作者 赵旭彤 薛雅文 许增博 葛仕宇 汪洋 虞林嫣 卞雨辰 安思瀚 杨博 向建军 杜关祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期409-415,共7页
An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the... An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the substrate medium,we design a circular microstrip antenna,which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz,specifically suitable for NV center experiments.Subsequently,this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support,allowing the optical fiber tip to extend out of a dedicated aperture.To mitigate errors originating from processing,precise tuning within a narrow range can be achieved by adjusting the conformal amplitude.Finally,we image the microwave magnetic field around the integrated probe with high resolution,and determine the suitable area for placing the fiber tip(SAP). 展开更多
关键词 nitrogen-vacancy center conformal antenna integrated probe magnetic field imaging
下载PDF
Distal-scanning common path probe for optical coherence tomography
16
作者 Zhengyu Chen Bin He +8 位作者 Zichen Yin Zhangwei Hu Yejiong Shi Chengming Wang Xiao Zhang Ning Zhang Linkai Jing Guihuai Wang Ping Xue 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期84-92,共9页
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be... In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus. 展开更多
关键词 Common path optical coherence tomography endoscopic probe
下载PDF
Temperature-controlled DCP Fluorescent Probe Based on Hydrogel-immobilized Quantum Dots Composite
17
作者 童伊琳 杨坤 +2 位作者 HAN Xuecai YU Kan BAO Jiaqi 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2024年第4期931-936,共6页
A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examina... A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examination of this probe revealed its attributes and factors affecting its performance.By using temperature modulation,the probe was adept at detecting DCP concentrations ranging between 1.0×10^(-6)and 9.0×10^(-6)mol/L.Such a probe offers remarkable selectivity,repeatability,and robust stability,so that the detection of DCP can be carried out at different temperatures,and a fast,reliable,sensitive and low-cost intelligent detection method is realized. 展开更多
关键词 temperature-controlled fluorescent probe hydrogel-immobilized quantum dots composite DCP
下载PDF
Progress in Mechanical Modeling of Implantable Flexible Neural Probes
18
作者 Xiaoli You Ruiyu Bai +9 位作者 Kai Xue Zimo Zhang Minghao Wang Xuanqi Wang Jiahao Wang Jinku Guo Qiang Shen Honglong Chang Xu Long Bowen Ji 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第8期1205-1231,共27页
Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,... Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,the rigid neural probes,such as Utah arrays,Michigan probes,and metal microfilament electrodes,are mechanically unmatched with brain tissue and are prone to rejection and glial scarring after implantation,which leads to a significant degradation in the signal quality with the implantation time.In recent years,flexible neural electrodes are rapidly developed with less damage to biological tissues,excellent biocompatibility,and mechanical compliance to alleviate scarring.Among them,the mechanical modeling is important for the optimization of the structure and the implantation process.In this review,the theoretical calculation of the flexible neural probes is firstly summarized with the processes of buckling,insertion,and relative interaction with soft brain tissue for flexible probes from outside to inside.Then,the corresponding mechanical simulation methods are organized considering multiple impact factors to realize minimally invasive implantation.Finally,the technical difficulties and future trends of mechanical modeling are discussed for the next-generation flexible neural probes,which is critical to realize low-invasiveness and long-term coexistence in vivo. 展开更多
关键词 Mechanical modeling flexible neural probes INVASIVE theoretical calculation simulation
下载PDF
Tb^(3+)-nucleic acid probe-based label-free and rapid detection of mercury pollution in food
19
作者 Xuhan Xia Chenxi Zhou +7 位作者 Yulin Zhu Yi Dong Qiang He Mohammad Rizwan Khan Yuanlong Chi Rosa Busquets Ruijie Deng Yao Ren 《Food Science and Human Wellness》 SCIE CSCD 2024年第2期993-998,共6页
Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluor... Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluorescence of terbium ions(Tb^(3+))via binding with single-strand DNA.Mercury ion,Hg^(2+)induced thymine(T)-rich DNA strand to form a double-strand structure(T-Hg^(2+)-T),thus leading to fluorescence reduction.Based on the principle,Hg^(2+)can be quantified based on the fluorescence of Tb^(3+),the limit of detection was 0.0689μmol/L and the linear range was 0.1-6.0μmol/L.Due to the specificity of T-Hg^(2+)-T artificial base pair,the assay could distinguish Hg^(2+)from other metal ions.The recovery rate was ranged in 98.71%-101.34%for detecting mercury pollution in three food samples.The assay is low-cost,separation-free and mix-to-read,thus was a competitive tool for detection of mercury pollution to ensure food safety. 展开更多
关键词 Mercury pollution Food safety Nucleic acid probe LABEL-FREE TERBIUM
下载PDF
A Study of Radiation-Induced Telomere Instability Using Multiplex Ligation-Dependent Probe Amplification (MLPA)
20
作者 Alan Chant Ahmad Chaudary Christina M. Kraemer-Chant 《Advances in Biological Chemistry》 CAS 2024年第3期73-85,共13页
The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA).... The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA). The TK6 cell line has the native p53 tumor-suppressor gene, whereas WTK1 cells contain a p53 mutation. Each cell line was isolated pre- and post-irradiation (2 and 3 Gy) and analyzed by MLPA. The impact of irradiation on these two cell lines was investigated using probes that target specific regions on chromosomes associated with subtelomeric regions. Results indicate that WTK1 and TK6 are impacted differently after irradiation, and that each cell line presents its own unique MLPA profile. The most notable differences are the appearance of a number of probes in the post-irradiated MLPA profile that are not present in the controls, and two unique probe signals only seen in WTK1 cells. These results build on our previous studies that indicate how different human cell lines can be affected by radiation in significantly different ways depending on the presence or absence of wild type p53. 展开更多
关键词 Ionizing Radiation Multiplex Ligation-Dependent probe Amplification (MLPA) p53 Tumor Suppressor Telomere Instability
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部