期刊文献+
共找到59,838篇文章
< 1 2 250 >
每页显示 20 50 100
Application Value of High-Frequency Ultrasound and Contrast-Enhanced Ultrasound in Patients with Knee Osteoarthritis with Different TCM Syndromes 被引量:1
1
作者 Yufei Wang Yingcong Xiao +5 位作者 Zhao Shen Peilu Wang He Chang Hongjuan Mao Xiufen Yao Youmin Guo 《Journal of Biosciences and Medicines》 2020年第12期149-156,共8页
<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging ev... <strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types. 展开更多
关键词 Knee Osteoarthritis high-frequency ultrasound Contrast-Enhanced ultrasound Syndrome
下载PDF
Development of a High-frequency Ultrasound System for High-speed Image Scanning 被引量:1
2
作者 WU Jian-xing CHEN Pei-zhan +2 位作者 WANG Jian-lin CHEN Guan-chun CHEN Tai-song 《Chinese Journal of Biomedical Engineering(English Edition)》 2013年第2期79-85,92,共8页
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ... High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology. 展开更多
关键词 high-frequency ultrasound time gain compensation (TGC) multi-focus scan
下载PDF
Efficacy evaluation of high-frequency ultrasound in the treatment of diabetic peripheral neuropathy with α-lipoic acid combined with traditional Chinese medicine package treatment
3
作者 Pei Hu Guang-Mei Zheng +4 位作者 Zheng-Sen Dong Rui Xue Hong-Cheng Ding De-Jiao Sun Bin Xiao 《Journal of Hainan Medical University》 2021年第6期20-25,共6页
Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clin... Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clinical medication and evaluation of therapeutic effect.Methods:From December 2018 to December 2019,110 patients with DPN who met the inclusion and exclusion criteria were divided into observation group and control group according to different treatment plans.The control group was treated withα-lipoic acid,and the observation group was treated withα-lipoic acid combined with traditional Chinese medicine encapsulation treatment,and used high-frequency ultrasound,nerve conduction velocity and serological examination to comprehensively evaluate the effectiveness of the two treatment methods.Results:The mean amplitude of glycemic excursions(MAGE)value of the observation group and the control group after treatment was significantly lower than before treatment(P<0.05);After treatment,the SCV of the ulnar nerve,median nerve,and common peroneal nerve in the two groups was significantly faster than before treatment(P<0.05).Similar to SCV,the MCV of the three nerves measured after treatment in the two groups was significantly faster than before treatment(P<0.05).Compared between the groups after treatment,the three kinds of nerve SCV and MCV in the observation group were significantly faster than those in the control group(P<0.05).The cross-sectional area(CSA)value of the ulnar nerve,median nerve and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).Compared with the control group after treatment,the three nerves CSA in the observation group was significantly lower than that in the control group(P<0.05).Abnormal ultrasound performance:The proportion of abnormal ultrasound performances of the ulnar nerve,median nerve,and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).The composition ratio of internal echo reduction and ambiguity in the observation group after three nerve treatments was significantly lower than that in the control group after treatment(P<0.05).In the correlation analysis,the three kinds of nerve CSA before and after treatment were negatively correlated with SCV and amplitude(P<0.05),and positively correlated with latency(P<0.05).Conclusion:The combination ofα-lipoic acid and Chinese medicine encapsulation technology has a good effect on the treatment and repair of DPN nerve damage,and can be routinely applied in clinical treatment.High-frequency ultrasound can intuitively observe changes in peripheral nerves and can be used to evaluate the prognosis of DPN. 展开更多
关键词 high-frequency ultrasound α-lipoic acid Traditional Chinese medicine package treatment Diabetic peripheral neuropathy Nerve conduction velocity
下载PDF
Analysis of High-Frequency Ultrasound in the differential Diagnosis of Lumps in Foot and Hand
4
作者 Huitong Yan Heying Li +1 位作者 Jianmei Han Yingbo Tang 《Proceedings of Anticancer Research》 2020年第4期27-31,共5页
Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in ha... Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in hand and foot were retrospectively analyzed,including the location,size,shape,boundary,internal echo and posterior echo,surrounding relationship and blood flow.Results:Among 65 cases,there were 26 cases of tendon sheath cyst,16 cases of tenosynovitis giant cell tumor,10 cases of hemangioma,4 cases of tendon sheath fibroma,3 cases of epidermoid cyst,2 cases of Schwannoma,2 cases of fibrolipoma,1 case of angiolipoma and 1 case of neurofibroma.The preoperative and postoperative pathological diagnoses of 45 cases,accounting for 69.23%,were consistent,3 cases(4.62%)were misdiagnosed,which included that 2 cases of tenosynovitis giant cell tumor were misdiagnosed as tendon sheath cyst,1 case of neurofibroma as epidermoid cyst,and the preoperative diagnosis of the rest 17 cases(26.15%)were indefinite.Conclusion:The high-frequency ultrasound can diagnose properties of lumps in foot and hand well,providing diagnosis basis for further treatment in clinic. 展开更多
关键词 high-frequency ultrasound Lumps Hand and foot Publication
下载PDF
High-frequency Ultrasound Evaluation of Effects of Early Treatment with Metoprolol on Myocardial Inflammatory Cytokine Expression in Rats with Acute Myocardial Infarction 被引量:4
5
作者 武文 黄晓玲 +2 位作者 张江霞 高宇 杨亚利 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2012年第5期774-778,共5页
This study evaluated the effects of early treatment with β-adrenergic blocker metoprolol on ventricular remodeling and function after acute myocardial infarction (AMI) by using high frequency ultrasound.The relations... This study evaluated the effects of early treatment with β-adrenergic blocker metoprolol on ventricular remodeling and function after acute myocardial infarction (AMI) by using high frequency ultrasound.The relationship between the efficacy and the expression level of cardiac myocardial inflammatory cytokine was examined in rats.The rat model of AMI was induced by ligating the left ante-rior descending artery.The surviving rats were randomly assigned to two experimental groups:MI control (MI) group and MI metoprolol (MI-B) group,with the rats undergoing sham operation serving as normal control (Sham).MI-B group was given metoprolol for 4 weeks (refer to the CCS-2 protocol) and the other two groups received equal volume of saline via intragastric (i.g.) administation.The ventricular remodeling and function were evaluated by high frequency ultrasound 4 weeks after the treatment.Then all rats were sacrificed for pathological examination and immunohistochemistrical detection of inflammatory cytokines,including IL-1β,IL-6,IL-10 and TNF-α.Compared with the MI group,the left ventricular end-systolic dimension,end-diastolic dimension,end-systolic volume and end-diastolic volume of the MI-B group were significantly decreased (P<0.01),while the left ventricular anterior wall end-diastolic thickness,ejection fraction and fractional shortening were obviously increased (P<0.01).The conspicuous improvement in the left ventricular morphology and function was coincident with the markedly reduced TNF-α and IL-1β expression and the increased IL-10 expression.We are led to conclude that early metoprolol treatment for AMI can regulate myocardial inflammatory cytokine expression to improve cardiac function and the underlying mechanism might be that it decreases the level of pro-inflammatory cytokines and increases the level of its anti-inflammatory counterparts in cardiac myocytes.Our study also showed that echocardiography is a useful technique for the structural and functional assessment of left ventricle after acute myocardial infarction. 展开更多
关键词 high frequency ultrasound myocardial infarction METOPROLOL CYTOKINES inflammation
下载PDF
Kinematic deformation and intensity assessment of the 2021 Maduo M_(S)7.4 earthquake in Qinghai revealed by high-frequency GNSS
6
作者 Yu Li Yuebing Wang +2 位作者 Lijiang Zhao Hongbo Shi Pingping Wang 《Geodesy and Geodynamics》 EI CSCD 2024年第3期230-240,共11页
Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advance... Rapid acquisition of the kinematic deformation field and seismic intensity distribution of large earthquakes is crucial for postseismic emergency rescue,disaster assessment,and future seismic risk research.The advancement of GNSS observation and data processing makes it play an important role in this field,especially the high-frequency GNSS.We used the differential positioning method to calculate the 1 HZ GNSS data from 98 sites within 1000 km of the M_(S)7.4 Maduo earthquake epicenter.The kinematic deformation field and the distribution of the seismic intensity by using the peak ground velocity derived from displacement waveforms were obtained.The results show that:1)Horizontal coseismic response deformation levels ranging from 25 mm to 301 mm can be observed within a 1000 km radius from the epicenter.Coseismic response deformation on the east and west sides shows bilateral asymmetry,which markedly differs from the symmetry presented by surface rupture.2)The seismic intensity obtained through high-frequency GNSS and field investigations exhibits good consistency of the scope and orientation in the high seismic intensity area,although the former is generally slightly smaller than the latter.3)There may exist obstacles on the eastern side of the seismogenic fault.The Maduo earthquake induced a certain tectonic stress loading effect on the western Kunlun Pass-Jiangcuo fault(KPJF)and Maqin-Maqu segment,resulting in higher seismic risk in the future. 展开更多
关键词 Maduo earthquake high-frequency GNSS Kinematic deformation Seismic intensity
下载PDF
Dynamic Response of Foundations during Startup of High-Frequency Tunnel Equipment
7
作者 Dawei Ruan Mingwei Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第7期821-844,共24页
The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is ... The specialized equipment utilized in long-line tunnel engineering is evolving towards large-scale,multifunctional,and complex orientations.The vibration caused by the high-frequency units during regular operation is supported by the foundation of the units,and the magnitude of vibration and the operating frequency fluctuate in different engineering contexts,leading to variations in the dynamic response of the foundation.The high-frequency units yield significantly diverse outcomes under different startup conditions and times,resulting in failure to meet operational requirements,influencing the normal function of the tunnel,and causing harm to the foundation structure,personnel,and property in severe cases.This article formulates a finite element numerical computation model for solid elements using three-dimensional elastic body theory and integrates field measurements to substantiate and ascertain the crucial parameter configurations of the finite element model.By proposing a comprehensive startup timing function for high-frequency dynamic machines under different startup conditions,simulating the frequency andmagnitude variations during the startup process,and suggesting functions for changes in frequency and magnitude,a simulated startup schedule function for high-frequency machines is created through coupling.Taking into account the selection of the transient dynamic analysis step length,the dynamic response results for the lower dynamic foundation during its fundamental frequency crossing process are obtained.The validation checks if the structural magnitude surpasses the safety threshold during the critical phase of unit startup traversing the structural resonance region.The design recommendations for high-frequency units’dynamic foundations are provided,taking into account the startup process of the machine and ensuring the safe operation of the tunnel. 展开更多
关键词 Tunnel equipment high-frequency units startup conditions transient dynamics dynamic response foundation design
下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
8
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
下载PDF
Therapeutic efficacy of methylprednisolone sodium succinate via diverse administration routes for mid-to high-frequency sudden sensorineural hearing loss
9
作者 Xiang-Da Meng Ting-Ting Li Li-Min Deng 《World Journal of Clinical Cases》 SCIE 2024年第18期3321-3331,共11页
BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use o... BACKGROUND Sudden sensorineural hearing loss(SSNHL),characterized by a rapid and unexplained loss of hearing,particularly at moderate to high frequencies,presents a significant clinical challenge.The therapeutic use of methylprednisolone sodium succinate(MPSS)via different administration routes,in combination with conventional medications,remains a topic of interest.AIM To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid-to high-frequency SSNHL.METHODS The medical records of 109 patients with mid-to high-frequency SSNHL were analyzed.The patients were divided into three groups based on the route of administration:Group A[intratympanic(IT)injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection],Group B(intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection),and Group C(single IT injection of MPSS).The intervention effects were compared and analyzed.RESULTS The posttreatment auditory thresholds in Group A(21.23±3.34)were significantly lower than those in Groups B(28.52±3.36)and C(30.23±4.21;P<0.05).Group A also exhibited a significantly greater speech recognition rate(92.23±5.34)than Groups B and C.The disappearance time of tinnitus,time to hearing recovery,and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C(P<0.05).The total effective rate in Group A(97.56%)was significantly greater than that in Groups B and C(77.14%and 78.79%,χ^(2)=7.898,P=0.019).Moreover,the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B(4.88%,3.03%vs 2.57%,χ^(2)=11.443,P=0.003),and the recurrence rate in Group A was significantly lower than that in Groups B and C(2.44%vs 20.00%vs 21.21%,χ^(2)=7.120,P=0.028).CONCLUSION IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS.This approach effectively improves patients'hearing and reduces the risk of disease recurrence. 展开更多
关键词 Sudden loss of hearing at middle-and high-frequency of the descending type Methylprednisolone sodium succinate Intratympanic injection Intravenous injection
下载PDF
Differential diagnosis of isolated calf muscle vein thrombosis and gastrocnemius hematoma by high-frequency ultrasound 被引量:14
10
作者 SU Li-ya GUO Fa-jin XU Guang HAN Xiu-jie SUN Chang-kun ZHANG Zheng JING Qing-hong 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第23期4448-4452,共5页
Background Differential diagnosis of isolated calf muscle vein thrombosis (ICMVT) and gastrocnemius hematoma is essential for early identification of deep vein thrombosis (DVT).This study aimed to investigate the ... Background Differential diagnosis of isolated calf muscle vein thrombosis (ICMVT) and gastrocnemius hematoma is essential for early identification of deep vein thrombosis (DVT).This study aimed to investigate the diagnostic value of high-frequency color Doppler ultrasound for differential diagnosis of ICMVT and gastrocnemius hematoma.Methods A retrospective case series of 35 ICMVT (M∶F,21∶14; mean age (64.5±10.6) years) and 23 gastrocnemius hematoma (M∶F,16∶7; mean age (75.4±11.8) years) patients with bilateral/unilateral lower limb pain was conducted between January 2006 and September 2012.Characteristics and the morphology of high-frequency color Doppler ultrasonography of the lower limb deep vein,great saphenous vein,calf muscles,skin,and soft tissue were examined.Results ICMVT hypoechoic signals were characterized by long,tube-like masses on longitudinal sections and oval masses on transverse sections,with apparent muscle thrombosis boundaries,distal and proximal venous connections,and,often,lower limb DVT.Gastrocnemius hematoma hypoechoic signals were characterized by large volumes,enhanced posterior hematoma echo,hyperechoic muscle boundaries,no hematoma blood flow,and no DVT,and clear differences in trauma/exercise-and oral anticoagulant-induced hematomas were readily apparent.According to the measurement,the ratio of long diameter/transverse diameter (D/T) in ICMVT patients was about less than 2.0,whereas in gastrocnemius hematoma patients the ratio was more than 2.0.Early stage isoechoic and hypoechoic signals were detected with gradually increasing ovular anechoic areas.Partial muscle fibers in the hematoma due to muscle fractures were apparent.Conclusion High-frequency color Doppler ultrasound was found to be a sensitive and reliable method for differential diagnosis of ICMVT and gastrocnemius hematoma due to trauma and exercise or prolonged oral anticoagulant use. 展开更多
关键词 high-frequency ultrasound CALF venous thrombosis HEMATOMA
原文传递
High-frequency ultrasound features of basal cell carcinoma and its association with histological recurrence risk 被引量:13
11
作者 Shi-Qi Wang Jie Liu +5 位作者 Qing-Li Zhu Chen-Yang Zhao Tao Qu Feng Li Ximena Wortsman Hong-Zhong Jin 《Chinese Medical Journal》 SCIE CAS CSCD 2019年第17期2021-2026,共6页
Background: Due to advances in high-frequency ultrasound technology, it is easier to detect fine structures of skin lesions. The aim of this study was to examine the ultrasonographic features and use recurrence risk s... Background: Due to advances in high-frequency ultrasound technology, it is easier to detect fine structures of skin lesions. The aim of this study was to examine the ultrasonographic features and use recurrence risk stratification to assess the diagnostic performance of pre-operative ultrasound examination of basal cell carcinoma (BCC). Methods: This was a retrospective study. Forty-six BCC lesions underwent pre-operative ultrasound examination using 50- and 20- MHz probes. Ultrasonographic shape, margin, internal echoes, hyper-echoic spots, posterior echoes, and depth of the lesion were evaluated and correlated with the risk of recurrence based on histological features. Results: Forty-two patients had 46 skin lesions in total. The high-risk (n = 6) and low-risk (n = 40) groups exhibited considerable overlap in the ultrasonographic manifestations and no significant difference in margin (χ^2 = 3.231, P = 0.072), internal echo (χ^2 = 1.592, P = 0.207), or posterior echo (P = 0.169). However, high-risk BCCs tended to be irregular in shape than low-risk lesions (χ^2 = 4.313, P = 0.038). Both types presented hyper-echoic spots (χ^2 = 1.850, P = 0.174). Additionally, 78% of low-risk lesions were confined to the dermis (31/40), and 100% of high-risk lesions infiltrated into the sub-cutaneous tissue, resulting in a significant difference between the two groups (χ^2 = 10.951, P = 0.001). Ultrasound detected sub-clinical lesions in five patients. Conclusions: High-frequency ultrasound can provide important information for pre-operative evaluation of risk in BCC foci and reveal hidden lesions. The technique may play a crucial role in guiding therapeutic options for BCC. 展开更多
关键词 high-frequency ultrasound BASAL cell carcinoma ultrasound SKIN ultrasound SKIN CANCER ultrasound SKIN CANCER
原文传递
Comparative study for predictability of type 1 gastric variceal rebleeding after endoscopic variceal ligation:High-frequency intraluminal ultrasound study 被引量:1
12
作者 Jeong Hwan Kim Won Hyeok Choe +3 位作者 Sun-Young Lee So Young Kwon In-Kyung Sung Hyung Seok Park 《World Journal of Clinical Cases》 SCIE 2021年第34期10566-10575,共10页
BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagog... BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagogastroduodenoscopy(EGD)and high-frequency intraluminal ultrasound(HFIUS)for type 1 gastric varices(GOV1)after EVL and to identify the predictability for rebleeding of EGD and HFIUS.METHODS In liver cirrhosis patients with GOV1,we performed endoscopic follow-up using EGD and HFIUS synchronously after EVL for hemorrhage from GOV1.Endoscopic grading and red color signs were analyzed using EGD,and the largest variceal cross-sectional areas were measured using HFIUS.In addition,1-year follow-up was performed.Variceal rebleeding was defined as the presence of hematemesis,hematochezia,or melena without other evidence of bleeding on endoscopic follow-up.RESULTS In 26 patients with GOV1,variceal cross-sectional areas on HFIUS of GOV1 was poorly correlated with EGD grading of GOV1(r=0.36).In 17 patients who completed the 1-year follow-up,variceal cross-sectional areas on HFIUS was a good predictor of subsequent rebleeding,whereas EGD grading was not a predictor of subsequent rebleeding.CONCLUSION HFIUS measurement is more predictive of GOV1 rebleeding than EGD grading,so HFIUS measurement may be necessary for endoscopic follow-up after EVL in patients with GOV1. 展开更多
关键词 Endoscopic variceal ligation ESOPHAGOGASTRODUODENOSCOPY high-frequency intraluminal ultrasound REBLEEDING Type 1 gastric varices
下载PDF
Radio-frequency measurements of energetic-electron-driven emissions using high-frequency magnetic probe on XuanLong-50 spherical torus
13
作者 王明远 伦秀春 +3 位作者 薄晓坤 刘兵 刘阿娣 石跃江 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期33-38,共6页
A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and dat... A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and data acquisition system of the probe are comprehensively examined.The fluctuation data from the EXL-50 plasma are analyzed in the time–frequency domain using fast Fourier transforms.Moreover,distinct high-frequency instabilities are detected using this diagnostic system.In particular,significant frequency chirping is observed,which is consistent with the bumpon-tail drive instability predicted using the Berk–Breizman model. 展开更多
关键词 high-frequency magnetic probe high-frequency instabilities XuanLong-50
下载PDF
Tuning magneto-dielectric properties of Co_(2)Z ferrites via Gd doping for high-frequency applications
14
作者 武剑 卢冰 +6 位作者 张颖 陈一鑫 孙凯 陈大明 李强 刘颖力 李颉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期468-473,共6页
Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,an... Magneto-dielectric properties of Co_(2)Z ferrite materials are tuned via Gd doping for applications in high-frequency antennas and filters in the present work.Ba_(3)Co_(2)Fe_(24-x)Gd_(x)O_(41)(x=0.00,0.05,0.10,0.15,and 0.20)materials are successfully prepared by using solid-state method at 925℃for 4 h with 2.5-wt%Bi_(2)O_(3)sintering aids.The content of Gd^(3+)ion can affect micromorphology,grain size,bulk density,and magneto-dielectric properties of the ferrite.With Gd^(3+)ion content increasing,saturation magnetization(Ms)first increases and then decreases.The maximum value of Ms is 44.86 emu/g at x=0.15.Additionally,sites occupied by Gd^(3+)ions can change magnetic anisotropy constant of the ferrite.Magnetocrystalline anisotropy constant(K_1)is derived from initial magnetization curve,and found to be related to spin-orbit coupling and intersublattice interactions between metal ions.The real part of magnetic permeability(μ′)and real part of dielectric permittivity(ε′)are measured in a frequency range of 10 MHz-1 GHz.When x=0.15,material has excellent magneto-dielectric properties(μ′≈12.2 andε′≈17.61),low magnetic loss(tanδμ≈0.03 at 500 MHz),and dielectric loss(tanδε≈0.04 at 500 MHz).The results show that Gd-doped Co_(2)Z ferrite has broad application prospects in multilayer filters and high-frequency antennas. 展开更多
关键词 Co_(2)Z ferrite magneto-dielectric properties Gd doping high-frequency applications
下载PDF
Novel approach of ultrasound-guided lateral recess block for a patient with lateral recess stenosis: A case report 被引量:1
15
作者 Jiao Yang Xin-Ling Li Qing-Bing Li 《World Journal of Clinical Cases》 SCIE 2024年第5期1010-1017,共8页
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso... BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS. 展开更多
关键词 Lateral recess stenosis ultrasound Lateral recess block Real-time visualization Low back pain Case report
下载PDF
Potassium sodium niobate based lead-free ceramic for high-frequency ultrasound transducer applications 被引量:3
16
作者 Jie Xing Laiming Jiang +6 位作者 Chunlin Zhao Zhi Tan Qian Xu Jiagang Wu Qiang Chen Dingquan Xiao Jianguo Zhu 《Journal of Materiomics》 SCIE EI 2020年第3期513-522,共10页
The BiAlO_(3)(BA)and(Bi_(0.5)Na_(0.5))ZrO_(3)(BNZ)are selected to form a solid solution with(K_(0.48)Na_(0.52))NbO_(3) via traditional solid state technique to optimize the electrical performance and temperature stabi... The BiAlO_(3)(BA)and(Bi_(0.5)Na_(0.5))ZrO_(3)(BNZ)are selected to form a solid solution with(K_(0.48)Na_(0.52))NbO_(3) via traditional solid state technique to optimize the electrical performance and temperature stability of KNNbased lead-free ceramics,simultaneously.Here we show that doped BA has a great influence on phase structure,morphologies,and electrical properties.The XRD patterns and dielectric constant versus temperature curves reveal that an increase in the BA content results in a transform of phase structures from a coexistence state of rhombohedral,orthorhombic and tetragonal phases to pseudocubic phase.Owing to the construction of R-O-T phase boundary,optimized performances(T_(C)~336℃,d_(33)~306 pC/N,kp=0.48)are obtained in 0.962(K_(0.48)Na_(0.52))NbO_(3)-0.003BiAlO_(3)-0.035(Bi_(0.5)Na_(0.5))ZrO_(3)(KNN-3)ceramics.Based on the sintered KNN-3 ceramic samples,high-frequency ultrasound imaging transducers are designed and fabricated,which exhibits a high center frequency of 24.5 MHz,a broad -6 dB bandwidth of 97% and a high-sensitivity.Finally,the imaging characteristic of the lead-free transducers is demonstrated via ex vivo imaging of biological tissue structure.As environment friendly materials,the excellent electrical and acoustic performance of developed KNN-based ceramics has great potential for practical applications. 展开更多
关键词 Potassium sodium niobate Lead free piezoceramics Thermal stability ultrasound imaging transducers
原文传递
Is endoscopic ultrasound a promising technique in the diagnosis and treatment of liver diseases?
17
作者 Enver Zerem Željko Puljiz +3 位作者 Boris Zdilar Suad Kunosic Admir Kurtcehajic Omar Zerem 《World Journal of Gastroenterology》 SCIE CAS 2024年第22期2920-2922,共3页
Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,su... Percutaneous ultrasound has been a longstanding method in the diagnostics and interventional procedures of liver diseases.In some countries,its use is restricted to radiologists,limiting access for other clinicians,such as gastroenterologists.Endoscopic ultrasound,as a novel technique,plays a crucial role in diagnosis and treatment of digestive diseases.However,its use is sometimes recommended for conditions where no clear advantage over percutaneous ultrasound exists,leaving the impression that clinicians sometimes resort to an endoscopic approach due to the unavailability of percutaneous options. 展开更多
关键词 Endoscopic ultrasound Percutaneous ultrasound Liver biopsy Fine needle aspiration Focal liver lesion Liver abscess drainage
下载PDF
Dynamic contrast enhanced ultrasound in differential diagnosis of hepatocellular carcinoma: A systematic review and meta-analysis
18
作者 Giorgio Esposto Paolo Santini +5 位作者 Fabrizio Termite Linda Galasso Irene Mignini Maria Elena Ainora Antonio Gasbarrini Maria Assunta Zocco 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第6期2804-2815,共12页
BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histologic... BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histological exam.The patterns of enhancement and wash-out of liver nodules can be used to stratify the risk of malignancy only in cirrhotic patients and HCC frequently shows atypical features.Dynamic contrast-enhanced ultrasound(DCEUS)with standardized software could help to overcome these obstacles,providing functional and quantitative parameters and potentially improving accuracy in the evaluation of tumor perfusion.AIM To explore clinical evidence regarding the application of DCEUS in the differential diagnosis of liver nodules.METHODS A comprehensive literature search of clinical studies was performed to identify the parameters of DCEUS that could relate to histological diagnosis.In accordance with the study protocol,a qualitative and quantitative analysis of the evidence was planned.RESULTS Rise time was significantly higher in HCC patients with a standardized mean difference(SMD)of 0.83(95%CI:0.48-1.18).Similarly,other statistically significant parameters were mean transit time local with a SMD of 0.73(95%CI:0.20-1.27),peak enhancement with a SMD of 0.37(95%CI:0.03-0.70),area wash-in area under the curve with a SMD of 0.47(95%CI:0.13-0.81),wash-out area under the curve with a SMD of 0.55(95%CI:0.21-0.89)and wash-in and wash-out area under the curve with SMD of 0.51(95%CI:0.17-0.85).SMD resulted not significant in fall time and wash-in rate,but the latter presented a trend towards greater values in HCC compared to intrahepatic cholangiocarcinoma.CONCLUSION DCEUS could improve non-invasive diagnosis of HCC,leading to less liver biopsy and early treatment.This quantitative analysis needs to be applied on larger cohorts to confirm these preliminary results. 展开更多
关键词 Dynamic contrast enhanced ultrasound Hepatocellular carcinoma Intracellular cholangiocarcinoma Quantitative ultrasound Liver cancer Time-intensity curve
下载PDF
Quick and easy assessment of sarcopenia in cirrhosis: Can ultrasound be the solution?
19
作者 Francesca Campani Tancredi Vincenzo Li Cavoli +3 位作者 Umberto Arena Fabio Marra Erica Nicola Lynch Claudia Campani 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2287-2293,共7页
Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and aff... Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and affects the response to treatment of patients with hepatocellular carcinoma(HCC).For these reasons,identifying an easy-to-perform method to assess sarcopenia in is a key element in the optimization of care in this patient population.Assessment of muscle mass by computed tomography is considered the standard of care for the diagnosis of sarcopenia,but exposure to radiation and high costs limit its application in this setting,especially for repeated assessments.We believe that ultrasound,a cheap and harmless technique also used for HCC screening in cirrhotic patients,could have an expanding role in the diagnosis and follow-up of sarcopenia in these patients. 展开更多
关键词 SARCOPENIA ultrasound CIRRHOSIS Hepatocellular carcinoma Computed tomography
下载PDF
Seeing beneath the surface:Harnessing point-of-care ultrasound for internal jugular vein evaluation
20
作者 Vichayut Chayapinun Abhilash Koratala Taweevat Assavapokee 《World Journal of Cardiology》 2024年第2期73-79,共7页
Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to... Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data. 展开更多
关键词 Point-of-care ultrasound Bedside ultrasound Internal jugular vein Right atrial pressure Central venous pressure
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部