A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and dat...A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and data acquisition system of the probe are comprehensively examined.The fluctuation data from the EXL-50 plasma are analyzed in the time–frequency domain using fast Fourier transforms.Moreover,distinct high-frequency instabilities are detected using this diagnostic system.In particular,significant frequency chirping is observed,which is consistent with the bumpon-tail drive instability predicted using the Berk–Breizman model.展开更多
BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagog...BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagogastroduodenoscopy(EGD)and high-frequency intraluminal ultrasound(HFIUS)for type 1 gastric varices(GOV1)after EVL and to identify the predictability for rebleeding of EGD and HFIUS.METHODS In liver cirrhosis patients with GOV1,we performed endoscopic follow-up using EGD and HFIUS synchronously after EVL for hemorrhage from GOV1.Endoscopic grading and red color signs were analyzed using EGD,and the largest variceal cross-sectional areas were measured using HFIUS.In addition,1-year follow-up was performed.Variceal rebleeding was defined as the presence of hematemesis,hematochezia,or melena without other evidence of bleeding on endoscopic follow-up.RESULTS In 26 patients with GOV1,variceal cross-sectional areas on HFIUS of GOV1 was poorly correlated with EGD grading of GOV1(r=0.36).In 17 patients who completed the 1-year follow-up,variceal cross-sectional areas on HFIUS was a good predictor of subsequent rebleeding,whereas EGD grading was not a predictor of subsequent rebleeding.CONCLUSION HFIUS measurement is more predictive of GOV1 rebleeding than EGD grading,so HFIUS measurement may be necessary for endoscopic follow-up after EVL in patients with GOV1.展开更多
<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging ev...<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types.展开更多
Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical t...Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Materials and Methods: Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. Gestational age at delivery was recorded and compared against cervical elasticity. Results: CM examination data were analyzed for 127 women at 24<sup>0/7</sup> - 28<sup>6/7</sup> gestational weeks. sPTB was observed in 6.3% of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70 ± 0.26 kPa/mm compared to the term group’s 1.63 ± 0.65 kPa/mm with a p-value of 1.1 × 10<sup>−</sup><sup>4</sup>. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5 - 100.0). Conclusion: These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe has the potential to predict spontaneous preterm birth in a cost-effective manner.展开更多
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ...High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.展开更多
Two pairs of high-frequency magnetic probes were installed in the Large Helical Device (LHD). During the injection of a perpendicular neutral beam, ion cyclotron emissions (ICEs) with the fundamental frequency cor...Two pairs of high-frequency magnetic probes were installed in the Large Helical Device (LHD). During the injection of a perpendicular neutral beam, ion cyclotron emissions (ICEs) with the fundamental frequency corresponding to the ion cyclotron frequency at the plasma edge were detected, which are the same type of ICE as measured with the former spare ion cyclotron range of frequencies (ICRF) heating antennas. This type of ICE was further investigated with regard to the phase and intensity of signals. Another type of ICE was found in the LHD, and these ICEs were synchronized with bursts of toroidicity induced Alfv^n eigenmodes (TAE) and the rise of intensity of lost ion flux. Therefore the source of these ICEs was thought to be the particles transferred from the core to the outer region of plasma by the TAE bursts. The frequency of ICEs induced by the TAE bursts increases linearly with the magnetic field strength, since the ion cyclotron frequency increases with the magnetic field strength.展开更多
Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clin...Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clinical medication and evaluation of therapeutic effect.Methods:From December 2018 to December 2019,110 patients with DPN who met the inclusion and exclusion criteria were divided into observation group and control group according to different treatment plans.The control group was treated withα-lipoic acid,and the observation group was treated withα-lipoic acid combined with traditional Chinese medicine encapsulation treatment,and used high-frequency ultrasound,nerve conduction velocity and serological examination to comprehensively evaluate the effectiveness of the two treatment methods.Results:The mean amplitude of glycemic excursions(MAGE)value of the observation group and the control group after treatment was significantly lower than before treatment(P<0.05);After treatment,the SCV of the ulnar nerve,median nerve,and common peroneal nerve in the two groups was significantly faster than before treatment(P<0.05).Similar to SCV,the MCV of the three nerves measured after treatment in the two groups was significantly faster than before treatment(P<0.05).Compared between the groups after treatment,the three kinds of nerve SCV and MCV in the observation group were significantly faster than those in the control group(P<0.05).The cross-sectional area(CSA)value of the ulnar nerve,median nerve and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).Compared with the control group after treatment,the three nerves CSA in the observation group was significantly lower than that in the control group(P<0.05).Abnormal ultrasound performance:The proportion of abnormal ultrasound performances of the ulnar nerve,median nerve,and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).The composition ratio of internal echo reduction and ambiguity in the observation group after three nerve treatments was significantly lower than that in the control group after treatment(P<0.05).In the correlation analysis,the three kinds of nerve CSA before and after treatment were negatively correlated with SCV and amplitude(P<0.05),and positively correlated with latency(P<0.05).Conclusion:The combination ofα-lipoic acid and Chinese medicine encapsulation technology has a good effect on the treatment and repair of DPN nerve damage,and can be routinely applied in clinical treatment.High-frequency ultrasound can intuitively observe changes in peripheral nerves and can be used to evaluate the prognosis of DPN.展开更多
Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in ha...Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in hand and foot were retrospectively analyzed,including the location,size,shape,boundary,internal echo and posterior echo,surrounding relationship and blood flow.Results:Among 65 cases,there were 26 cases of tendon sheath cyst,16 cases of tenosynovitis giant cell tumor,10 cases of hemangioma,4 cases of tendon sheath fibroma,3 cases of epidermoid cyst,2 cases of Schwannoma,2 cases of fibrolipoma,1 case of angiolipoma and 1 case of neurofibroma.The preoperative and postoperative pathological diagnoses of 45 cases,accounting for 69.23%,were consistent,3 cases(4.62%)were misdiagnosed,which included that 2 cases of tenosynovitis giant cell tumor were misdiagnosed as tendon sheath cyst,1 case of neurofibroma as epidermoid cyst,and the preoperative diagnosis of the rest 17 cases(26.15%)were indefinite.Conclusion:The high-frequency ultrasound can diagnose properties of lumps in foot and hand well,providing diagnosis basis for further treatment in clinic.展开更多
Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clini...Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clinical practice to evaluate the hepatic inflow, yet invasive. The phase-contrast-MRI(PC-MRI) is not invasive and potentially applicable in assessing the hepatic blood flow. In the present study, we compared the hepatic inflow rates using the PC-MRI and the TTUS probe, and evaluated their predictive value of post-hepatectomy adverse events. Methods: Eighteen large white pigs were anaesthetized for PC-MRI and approximately 75% hepatic resection was performed under a unified protocol. The blood flow was measured in the hepatic artery(Qha), the portal vein(Qpv), and the aorta above the celiac trunk(Qca) using PC-MRI, and was compared to the TTUS probe. The Bland-Altman method was conducted and a partial least squares regression(PLS) model was implemented. Results: The mean Qpv measured in PC-MRI was 0.55 ± 0.12 L/min, and in the TTUS probe was 0.74 ± 0.17 L/min. Qca was 1.40 ± 0.47 L/min in the PC-MRI and 2.00 ± 0.60 L/min in the TTUS probe. Qha was 0.17 ± 0.10 L/min in the PC-MRI, and 0.13 ± 0.06 L/min in the TTUS probe. The Bland-Altman method revealed that the estimated bias of Qca in the PC-MRI was 32%(95% CI:-49% to 15%); Qha 17%(95% CI:-15% to 51%); and Qpv 40%(95% CI:-62% to 18%). The TTUS probe had a higher weight in predicting adverse outcomes after 75% resection compared to the PC-MRI( β= 0.35 and 0.43 vs β = 0.22 and 0.07, for tissue changes and premature death, respectively). Conclusions: There is a tendency of the PC-MRI to underestimate the flow measured by the TTUS probes. The TTUS probe measures are more predictive of relevant post-hepatectomy outcomes.展开更多
We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance in...We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions.展开更多
AIM: To assess the therapeutic value of endoscopic mucosal resection (EMR) under micro-probe ultrasound guidance for rectal carcinoids less than 1 cm in diameter. METHODS: Twenty-one patients pathologically diagnosed ...AIM: To assess the therapeutic value of endoscopic mucosal resection (EMR) under micro-probe ultrasound guidance for rectal carcinoids less than 1 cm in diameter. METHODS: Twenty-one patients pathologically diagnosed with rectal carcinoids following colonoscopy in our hospital from January 2007 to November 2012 were included in this study. The patients consisted of 14 men and 7 women, with a mean age of 52.3 ± 12.2 years (range: 36-72 years). The patients with submucosal tumors less than 1 cm in diameter arising from the rectal and muscularis mucosa detected by micro-probe ultrasound were treated with EMR and followed up with conventional endoscopy and micro-probe ultrasound. RESULTS: All of the 21 tumors were confirmed by micro-probe ultrasound as uniform hypoechoic masses originating from the rectal and muscularis mucosa, without invasion of muscularis propria and vessels, and less than 1 cm in diameter. EMR was successfully completed without bleeding, perforation or other complications. The resected specimens were immunohistochemically confirmed to be carcinoids. Patients were followed up for one to two years, and no tumor recurrence was reported. CONCLUSION: EMR is a safe and effective treatment for rectal carcinoids less than 1 cm in diameter.展开更多
In vivo imaging of cerebral ischemia/reperfusion injury remains an important challenge.We injected porous Ag/Au@SiO_(2) bimetallic hollow nanoshells carrying anti-tropomyosin 4 as a molecular probe into mice with cere...In vivo imaging of cerebral ischemia/reperfusion injury remains an important challenge.We injected porous Ag/Au@SiO_(2) bimetallic hollow nanoshells carrying anti-tropomyosin 4 as a molecular probe into mice with cerebral ischemia/reperfusion injury and observed microvascular changes in the brain using photoacoustic imaging with ultrasonography.At each measured time point,the total photoacoustic signal was significantly higher on the affected side than on the healthy side.Twelve hours after reperfusion,cerebral perfusion on the affected side increased,cerebrovascular injury worsened,and anti-tropomyosin 4 expression increased.Twenty-four hours after reperfusion and later,perfusion on the affected side declined slowly and stabilized after 1 week;brain injury was also alleviated.Histopathological and immunohistochemical examinations confirmed the brain injury tissue changes.The nanoshell molecular probe carrying anti-tropomyosin 4 has potential for use in early diagnosis of cerebral ischemia/reperfusion injury and evaluating its progression.展开更多
基金supported by National Natural Science Foundation of China(No.11706151)。
文摘A high-frequency magnetic probe is designed and developed on the XuanL ong-50(EXL-50)spherical torus to measure high-frequency magnetic field fluctuation.The magnetic loop,radio filters,radio-frequency limiter,and data acquisition system of the probe are comprehensively examined.The fluctuation data from the EXL-50 plasma are analyzed in the time–frequency domain using fast Fourier transforms.Moreover,distinct high-frequency instabilities are detected using this diagnostic system.In particular,significant frequency chirping is observed,which is consistent with the bumpon-tail drive instability predicted using the Berk–Breizman model.
基金Konkuk University Medical Center Research Grant 2018.
文摘BACKGROUND The efficacy of endoscopic ultrasonography for the follow-up of gastric varices treated with endoscopic variceal ligation(EVL)has not been established.AIM To evaluate the diagnostic correlation of esophagogastroduodenoscopy(EGD)and high-frequency intraluminal ultrasound(HFIUS)for type 1 gastric varices(GOV1)after EVL and to identify the predictability for rebleeding of EGD and HFIUS.METHODS In liver cirrhosis patients with GOV1,we performed endoscopic follow-up using EGD and HFIUS synchronously after EVL for hemorrhage from GOV1.Endoscopic grading and red color signs were analyzed using EGD,and the largest variceal cross-sectional areas were measured using HFIUS.In addition,1-year follow-up was performed.Variceal rebleeding was defined as the presence of hematemesis,hematochezia,or melena without other evidence of bleeding on endoscopic follow-up.RESULTS In 26 patients with GOV1,variceal cross-sectional areas on HFIUS of GOV1 was poorly correlated with EGD grading of GOV1(r=0.36).In 17 patients who completed the 1-year follow-up,variceal cross-sectional areas on HFIUS was a good predictor of subsequent rebleeding,whereas EGD grading was not a predictor of subsequent rebleeding.CONCLUSION HFIUS measurement is more predictive of GOV1 rebleeding than EGD grading,so HFIUS measurement may be necessary for endoscopic follow-up after EVL in patients with GOV1.
文摘<strong>Objective:</strong> To explore the application value of high-frequency ultrasound and contrast-enhanced ultrasound in different syndrome types of knee osteoarthritis, and to provide more imaging evidence for clinical diagnosis and treatment. <strong>Method:</strong> Sixty patients with KOA were selected according to TCM classification, which were mainly divided into Qi stagnation and blood stasis type and cold-dampness blockage type. All knee joints were routinely examined by high frequency ultrasound, and those with synovial hyperplasia were examined by contrast-enhanced ultrasound. High frequency ultrasound is the examination of synovium, cartilage and collateral ligament of knee joint based on two-dimensional ultrasound. Contrast-enhanced ultrasound (CEUS) refers to the contrast examination of synovium in knee joint patients with synovial hyperplasia. <strong>Result: </strong>Among them, the suprapatellar sac effusion and synovial thickening of Qi stagnation and blood stasis type were more obvious than those of cold-dampness arthralgia type (P < 0.05), and the degree of wear of the intercondylar cartilage of cold-dampness arthralgia type was more obvious than that of Qi stagnation. The blood stasis type is heavier and the meniscus bulge is higher (P < 0.05). The radiography of synovial hyperplasia showed that the area under the curve of Qi stagnation and blood stasis type was higher than that of cold dampness arthralgia type (P < 0.05), and the peak time was significantly shorter than that of cold dampness arthralgia type. There was no statistical difference in effective peak gradient and onset time of type (P > 0.05). <strong>Conclusion: </strong>To a certain extent, the high-frequency ultrasound and contrast-enhanced ultrasound performance of knee osteoarthritis can be used as a dialectical reference for different TCM syndrome types.
文摘Background: Premature cervical softening and shortening may be considered an early mechanical failure that predispose to preterm birth. Purpose: This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Materials and Methods: Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. Gestational age at delivery was recorded and compared against cervical elasticity. Results: CM examination data were analyzed for 127 women at 24<sup>0/7</sup> - 28<sup>6/7</sup> gestational weeks. sPTB was observed in 6.3% of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70 ± 0.26 kPa/mm compared to the term group’s 1.63 ± 0.65 kPa/mm with a p-value of 1.1 × 10<sup>−</sup><sup>4</sup>. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5 - 100.0). Conclusion: These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe has the potential to predict spontaneous preterm birth in a cost-effective manner.
文摘High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology.
基金supported by NIFS budgets NIFS10ULRR003,NIFS11ULRR703,and NIFS11PLRR302
文摘Two pairs of high-frequency magnetic probes were installed in the Large Helical Device (LHD). During the injection of a perpendicular neutral beam, ion cyclotron emissions (ICEs) with the fundamental frequency corresponding to the ion cyclotron frequency at the plasma edge were detected, which are the same type of ICE as measured with the former spare ion cyclotron range of frequencies (ICRF) heating antennas. This type of ICE was further investigated with regard to the phase and intensity of signals. Another type of ICE was found in the LHD, and these ICEs were synchronized with bursts of toroidicity induced Alfv^n eigenmodes (TAE) and the rise of intensity of lost ion flux. Therefore the source of these ICEs was thought to be the particles transferred from the core to the outer region of plasma by the TAE bursts. The frequency of ICEs induced by the TAE bursts increases linearly with the magnetic field strength, since the ion cyclotron frequency increases with the magnetic field strength.
基金National natural science foundation of China(No.81701891)Guided scientific research project of Shiyan science and technology bureau(No.18Y63)。
文摘Objective:To use high-frequency ultrasound to evaluate the efficacy ofα-lipoic acid combined with traditional Chinese medicine in the treatment of diabetic peripheral neuropathy(DPN),so as to provide a basis for clinical medication and evaluation of therapeutic effect.Methods:From December 2018 to December 2019,110 patients with DPN who met the inclusion and exclusion criteria were divided into observation group and control group according to different treatment plans.The control group was treated withα-lipoic acid,and the observation group was treated withα-lipoic acid combined with traditional Chinese medicine encapsulation treatment,and used high-frequency ultrasound,nerve conduction velocity and serological examination to comprehensively evaluate the effectiveness of the two treatment methods.Results:The mean amplitude of glycemic excursions(MAGE)value of the observation group and the control group after treatment was significantly lower than before treatment(P<0.05);After treatment,the SCV of the ulnar nerve,median nerve,and common peroneal nerve in the two groups was significantly faster than before treatment(P<0.05).Similar to SCV,the MCV of the three nerves measured after treatment in the two groups was significantly faster than before treatment(P<0.05).Compared between the groups after treatment,the three kinds of nerve SCV and MCV in the observation group were significantly faster than those in the control group(P<0.05).The cross-sectional area(CSA)value of the ulnar nerve,median nerve and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).Compared with the control group after treatment,the three nerves CSA in the observation group was significantly lower than that in the control group(P<0.05).Abnormal ultrasound performance:The proportion of abnormal ultrasound performances of the ulnar nerve,median nerve,and common peroneal nerve in the observation group after treatment was significantly lower than before treatment(P<0.05).The composition ratio of internal echo reduction and ambiguity in the observation group after three nerve treatments was significantly lower than that in the control group after treatment(P<0.05).In the correlation analysis,the three kinds of nerve CSA before and after treatment were negatively correlated with SCV and amplitude(P<0.05),and positively correlated with latency(P<0.05).Conclusion:The combination ofα-lipoic acid and Chinese medicine encapsulation technology has a good effect on the treatment and repair of DPN nerve damage,and can be routinely applied in clinical treatment.High-frequency ultrasound can intuitively observe changes in peripheral nerves and can be used to evaluate the prognosis of DPN.
文摘Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in hand and foot were retrospectively analyzed,including the location,size,shape,boundary,internal echo and posterior echo,surrounding relationship and blood flow.Results:Among 65 cases,there were 26 cases of tendon sheath cyst,16 cases of tenosynovitis giant cell tumor,10 cases of hemangioma,4 cases of tendon sheath fibroma,3 cases of epidermoid cyst,2 cases of Schwannoma,2 cases of fibrolipoma,1 case of angiolipoma and 1 case of neurofibroma.The preoperative and postoperative pathological diagnoses of 45 cases,accounting for 69.23%,were consistent,3 cases(4.62%)were misdiagnosed,which included that 2 cases of tenosynovitis giant cell tumor were misdiagnosed as tendon sheath cyst,1 case of neurofibroma as epidermoid cyst,and the preoperative diagnosis of the rest 17 cases(26.15%)were indefinite.Conclusion:The high-frequency ultrasound can diagnose properties of lumps in foot and hand well,providing diagnosis basis for further treatment in clinic.
基金supported mainly by the “Agence de la Biomedecine” through its program of Research(AOR 2009)BM,AC,BP,WM,VCI and VE acknowledged funding of project ANR-13-TECS-0006 by the Agence Nationale de la Recherche
文摘Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clinical practice to evaluate the hepatic inflow, yet invasive. The phase-contrast-MRI(PC-MRI) is not invasive and potentially applicable in assessing the hepatic blood flow. In the present study, we compared the hepatic inflow rates using the PC-MRI and the TTUS probe, and evaluated their predictive value of post-hepatectomy adverse events. Methods: Eighteen large white pigs were anaesthetized for PC-MRI and approximately 75% hepatic resection was performed under a unified protocol. The blood flow was measured in the hepatic artery(Qha), the portal vein(Qpv), and the aorta above the celiac trunk(Qca) using PC-MRI, and was compared to the TTUS probe. The Bland-Altman method was conducted and a partial least squares regression(PLS) model was implemented. Results: The mean Qpv measured in PC-MRI was 0.55 ± 0.12 L/min, and in the TTUS probe was 0.74 ± 0.17 L/min. Qca was 1.40 ± 0.47 L/min in the PC-MRI and 2.00 ± 0.60 L/min in the TTUS probe. Qha was 0.17 ± 0.10 L/min in the PC-MRI, and 0.13 ± 0.06 L/min in the TTUS probe. The Bland-Altman method revealed that the estimated bias of Qca in the PC-MRI was 32%(95% CI:-49% to 15%); Qha 17%(95% CI:-15% to 51%); and Qpv 40%(95% CI:-62% to 18%). The TTUS probe had a higher weight in predicting adverse outcomes after 75% resection compared to the PC-MRI( β= 0.35 and 0.43 vs β = 0.22 and 0.07, for tissue changes and premature death, respectively). Conclusions: There is a tendency of the PC-MRI to underestimate the flow measured by the TTUS probes. The TTUS probe measures are more predictive of relevant post-hepatectomy outcomes.
基金supported by Hunan Health and Family Planning Commission program[C2017060]
文摘We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions.
文摘AIM: To assess the therapeutic value of endoscopic mucosal resection (EMR) under micro-probe ultrasound guidance for rectal carcinoids less than 1 cm in diameter. METHODS: Twenty-one patients pathologically diagnosed with rectal carcinoids following colonoscopy in our hospital from January 2007 to November 2012 were included in this study. The patients consisted of 14 men and 7 women, with a mean age of 52.3 ± 12.2 years (range: 36-72 years). The patients with submucosal tumors less than 1 cm in diameter arising from the rectal and muscularis mucosa detected by micro-probe ultrasound were treated with EMR and followed up with conventional endoscopy and micro-probe ultrasound. RESULTS: All of the 21 tumors were confirmed by micro-probe ultrasound as uniform hypoechoic masses originating from the rectal and muscularis mucosa, without invasion of muscularis propria and vessels, and less than 1 cm in diameter. EMR was successfully completed without bleeding, perforation or other complications. The resected specimens were immunohistochemically confirmed to be carcinoids. Patients were followed up for one to two years, and no tumor recurrence was reported. CONCLUSION: EMR is a safe and effective treatment for rectal carcinoids less than 1 cm in diameter.
基金supported by the National Natural Science Foundation of China,No.81730050(to WH).
文摘In vivo imaging of cerebral ischemia/reperfusion injury remains an important challenge.We injected porous Ag/Au@SiO_(2) bimetallic hollow nanoshells carrying anti-tropomyosin 4 as a molecular probe into mice with cerebral ischemia/reperfusion injury and observed microvascular changes in the brain using photoacoustic imaging with ultrasonography.At each measured time point,the total photoacoustic signal was significantly higher on the affected side than on the healthy side.Twelve hours after reperfusion,cerebral perfusion on the affected side increased,cerebrovascular injury worsened,and anti-tropomyosin 4 expression increased.Twenty-four hours after reperfusion and later,perfusion on the affected side declined slowly and stabilized after 1 week;brain injury was also alleviated.Histopathological and immunohistochemical examinations confirmed the brain injury tissue changes.The nanoshell molecular probe carrying anti-tropomyosin 4 has potential for use in early diagnosis of cerebral ischemia/reperfusion injury and evaluating its progression.