期刊文献+
共找到306,846篇文章
< 1 2 250 >
每页显示 20 50 100
High-Precision Doppler Frequency Estimation Based Positioning Using OTFS Modulations by Red and Blue Frequency Shift Discriminator 被引量:1
1
作者 Shaojing Wang Xiaomei Tang +3 位作者 Jing Lei Chunjiang Ma Chao Wen Guangfu Sun 《China Communications》 SCIE CSCD 2024年第2期17-31,共15页
Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Dopple... Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Doppler frequency for positioning is a promising research direction on communication and navigation integration. To tackle the high Doppler frequency and low signal-to-noise ratio(SNR) in satellite communication, this paper proposes a Red and Blue Frequency Shift Discriminator(RBFSD) based on the pseudo-noise(PN) sequence.The paper derives that the cross-correlation function on the Doppler domain exhibits the characteristic of a Sinc function. Therefore, it applies modulation onto the Delay-Doppler domain using PN sequence and adjusts Doppler frequency estimation by red-shifting or blue-shifting. Simulation results show that the performance of Doppler frequency estimation is close to the Cramér-Rao Lower Bound when the SNR is greater than -15dB. The proposed algorithm is about 1/D times less complex than the existing PN pilot sequence algorithm, where D is the resolution of the fractional Doppler. 展开更多
关键词 channel estimation communication and navigation integration Orthogonal Time Frequency and Space pseudo-noise sequence red-blue frequency shift discriminator
下载PDF
New research trends on high-precision time transfer technology 被引量:5
2
作者 DONG Ruifang QUAN Run'ai +6 位作者 HOU Feiyan WANG Shaofeng XIANG Xiao ZHOU Conghua WANG Mengmeng LIU Tao ZHANG Shou'gang 《Instrumentation》 2015年第4期3-15,共13页
High-precision time transfer plays an important role in the areas of fundamental research and applications. Accompanying w ith the remarkable improvements in the ability of generating and measuring high-accuracy time-... High-precision time transfer plays an important role in the areas of fundamental research and applications. Accompanying w ith the remarkable improvements in the ability of generating and measuring high-accuracy time-frequency signal,seeking for new time-transfer techniques betw een distant clocks w ith much further improved accuracy attracts attentions w orld-w idely. The time-transfer technique based on optical pulses has the highest precision presently,and the further improvement in the accuracy is heavily dependent on the time-domain properties of the pulse as w ell as the sensitivity of the applied measurement on the exchanged pulse. The application of optical frequency comb in time transfer for a precision up to femtosecond level are currently the focus of much interest,and has recently achieved many breakthroughs. Further investigations show that,utilizing quantum techniques,i.e. quantum measurement technique and quantum optical pulse source,can lead to a new limit on the measured timing information. Furthermore,it can be immune from atmospheric parameters,such as pressure,temperature,humidity and so on.Such quantum improvements on time-transfer have a bright prospect in the future applications requiring extremely high-accuracy timing and ranging. The potential achievements w ill form a technical basis for the future realization of sub-femtosecond time transfer system. 展开更多
关键词 high-precision time TRANSFER QUANTUM improvement PULSE SHAPING QUANTUM frequency COMB
下载PDF
High-precision and wide-range real-time neutron flux monitor system through multipoint linear calibration 被引量:5
3
作者 Ren-Jie Zhu Xiang Zhou +9 位作者 Zi-Hao Liu Wen-Di Wang Xiao-Li Mou Teng-Fei Fang Qing-Li Ma Xiu-Feng Xu Guo-Liang Yuan Li Zhao Ling-Feng Wei Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第9期98-106,共9页
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea... The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results. 展开更多
关键词 Multipoint linear calibration Real time Simulated neutron signal Neutron flux monitoring ITER HL-2A
下载PDF
FPGA-based High-precision Measurement Algorithm for the Ultrasonic Echo Time of Flight 被引量:3
4
作者 王伯雄 张金 《Journal of Measurement Science and Instrumentation》 CAS 2010年第2期103-107,共5页
Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement, the req... Based on the evaluation of advantages and disadvantages of high-precision digital time interval measuring algorithms, and combined with the principle of the typical time-difference ultrasonic flow measurement, the requirements for the measurement of echo time of flight put forward by the ultrasonic flow measurement are analyzed. A new high-precision time interval measurement algorithm is presented, which combines the pulse counting method with the phase delay interpolation. The pulse counting method is used to ensure a large dynamic measuring range, and a double-edge triggering counter is designed to improve the accuracy and reduce the counting quantization error. The phase delay interpolation is used to reduce the quantization error of pulse counting for further improving the time measurement resolution. Test data show that the systexn for the measurement of the ultrasonic echo time of flight based on this algorithm and implemented on an Field Programmable Gate Army(FleA) needs a relatively short time for measurement, and has a measurement error of less than 105 ps. 展开更多
关键词 ultrasonic flow measurement time of flight phase delay interpolation
下载PDF
Study on Characteristics of a High-Precision Cold Gas Micro Thruster
5
作者 Zhaoli Wang Changbin Guan +2 位作者 Xudong Wang Weijie Zheng Longfei Su 《Engineering(科研)》 2024年第1期38-45,共8页
In order to improve the reliability of the spacecraft micro cold gas propulsion system and realize the precise control of the spacecraft attitude and orbit, a micro-thrust, high-precision cold gas thruster is carried ... In order to improve the reliability of the spacecraft micro cold gas propulsion system and realize the precise control of the spacecraft attitude and orbit, a micro-thrust, high-precision cold gas thruster is carried out, at the same time due to the design requirements of the spacecraft, this micro-thrust should be continuous working more than 60 minutes, the traditional solenoid valve used for the thrusts can’t complete the mission, so a long-life micro latching valve is developed as the control valve for this micro thruster, because the micro latching valve can keep its position when it cuts off the outage. Firstly, the authors introduced the design scheme and idea of the thruster. Secondly, the performance of the latching valve and the flow characteristics of the nozzle were simulated. Finally, from the experimental results and compared with the numerical study, it shows that the long-life micro cold gas thruster developed in this paper meets the mission requirements. 展开更多
关键词 high-precision Micro Thruster Performance Flow Characteristic EXPERIMENT
下载PDF
High-Precision Time Delay Estimation Based on Closed-Form Offset Compensation
6
作者 Yingying Li Hang Jiang +1 位作者 Lianjie Yu Jianfeng Li 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第3期2123-2136,共14页
To improve the estimation accuracy,a novel time delay estimation(TDE)method based on the closed-form offset compensation is proposed.Firstly,we use the generalized cross-correlation with phase transform(GCC-PHAT)metho... To improve the estimation accuracy,a novel time delay estimation(TDE)method based on the closed-form offset compensation is proposed.Firstly,we use the generalized cross-correlation with phase transform(GCC-PHAT)method to obtain the initial TDE.Secondly,a signal model using normalized cross spectrum is established,and the noise subspace is extracted by eigenvalue decomposition(EVD)of covariance matrix.Using the orthogonal relation between the steering vector and the noise subspace,the first-order Taylor expansion is carried out on the steering vector reconstructed by the initial TDE.Finally,the offsets are compensated via simple least squares(LS).Compared to other state-of-the-art methods,the proposed method significantly reduces the computational complexity and achieves better estimation performance.Experiments on both simulation and real-world data verify the efficiency of the proposed approach. 展开更多
关键词 Time delay estimation(TDE) time difference of arrival(TDOA) taylor expansion SUPER-RESOLUTION
下载PDF
Impact of time between meniscal injury and isolated meniscus repair on post-operative outcomes:A systematic review
7
作者 Kashif Javid Xavier Akins +2 位作者 Nicole G Lemaster Amer Ahmad Austin V Stone 《World Journal of Clinical Cases》 SCIE 2025年第7期39-45,共7页
BACKGROUND Meniscal tears are one of the most common knee injuries.After the diagnosis of a meniscal tear has been made,there are several factors physicians use to guide clinical decision-making.The influence of time ... BACKGROUND Meniscal tears are one of the most common knee injuries.After the diagnosis of a meniscal tear has been made,there are several factors physicians use to guide clinical decision-making.The influence of time between injury and isolated meniscus repair on patient outcomes is not well described.Assessing this relationship is important as it may influence clinical decision-making and can add to the preoperative patient education process.We hypothesized that increasing the time from injury to meniscus surgery would worsen postoperative outcomes.AIM To investigate the current literature for data on the relationship between time between meniscus injury and repair on patient outcomes.METHODS PubMed,Academic Search Complete,MEDLINE,CINAHL,and SPORTDiscus were searched for studies published between January 1,1995 and July 13,2023 on isolated meniscus repair.Exclusion criteria included concomitant ligament surgery,incomplete outcomes or time to surgery data,and meniscectomies.Patient demographics,time to injury,and postoperative outcomes from each study were abstracted and analyzed.RESULTS Five studies met all inclusion and exclusion criteria.There were 204(121 male,83 female)patients included.Three of five(60%)studies determined that time between injury and surgery was not statistically significant for postoperative Lysholm scores(P=0.62),Tegner scores(P=0.46),failure rate(P=0.45,P=0.86),and International Knee Documentation Committee scores(P=0.65).Two of five(40%)studies found a statistically significant increase in Lysholm scores with shorter time to surgery(P=0.03)and a statistically significant association between progression of medial meniscus extrusion ratio(P=0.01)and increasing time to surgery.CONCLUSION Our results do not support the hypothesis that increased time from injury to isolated meniscus surgery worsens postoperative outcomes.Decision-making primarily based on injury interval is thus not recommended. 展开更多
关键词 MENISCUS Meniscal Meniscus repair MENISCECTOMY Patient reported outcomes Postoperative outcomes Time to surgery Injury interval
下载PDF
Storage time affects the level and diagnostic efficacy of plasma biomarkers for neurodegenerative diseases
8
作者 Lifang Zhao Mingkai Zhang +4 位作者 Qimeng Li Xuemin Wang Jie Lu Ying Han Yanning Cai 《Neural Regeneration Research》 SCIE CAS 2025年第8期2373-2381,共9页
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k... Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results. 展开更多
关键词 Alzheimer’s disease amyloid-β diagnostic ability glial fibrillary acidic protein NEURODEGENERATION neurofilament light chain plasma biomarkers single molecule array storage time tau
下载PDF
High-precision automatic measurement of two-dimensional geometric features based on machine vision 被引量:6
9
作者 何博侠 何勇 +1 位作者 薛蓉 杨洪锋 《Journal of Southeast University(English Edition)》 EI CAS 2012年第4期428-433,共6页
To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition a... To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition and working principle are introduced. The mapping relationship between the feature image coordinates and the measuring space coordinates is established. The method of measuring path planning of small field of view (FOV) images is proposed. With the cooperation of the panoramic image of the object to be measured, the small FOV images with high object plane resolution are acquired automatically. Then, the auxiliary measuring characteristics are constructed and the parameters of the features to be measured are automatically extracted. Experimental results show that the absolute value of relative error is less than 0. 03% when applying the cooperative measurement system to gauge the hole distance of 100 mm nominal size. When the object plane resolving power of the small FOV images is 16 times that of the large FOV image, the measurement accuracy of small FOV images is improved by 14 times compared with the large FOV image. It is suitable for high-precision automatic measurement of two-dimensional complex geometric features distributed on large scale parts. 展开更多
关键词 machine vision two-dimensional geometric features high-precision measurement automatic measurement
下载PDF
A High-Precision Time Handling Library 被引量:1
10
作者 Irina Fedotova Eduard Siemens Hao Hu 《通讯和计算机(中英文版)》 2013年第8期1076-1086,共11页
关键词 时间处理 高精度 网络性能 时间计数器 Linux 计算机资源 时间控制 测量程序
下载PDF
Coordinate unification method of high-precision composite measurement in two dimensions 被引量:1
11
作者 文信 付鲁华 +2 位作者 赵炎 张恒 王仲 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第3期205-213,共9页
Multi-sensor coordinate unification in dimensional metrology is used in order to get holistic, more accurate and reliable information about a workpiece based on several or multiple measurement values from ... Multi-sensor coordinate unification in dimensional metrology is used in order to get holistic, more accurate and reliable information about a workpiece based on several or multiple measurement values from one or more sensors. Because of the problem that standard ball is deficient as a standard artifact in the coordinate unification of high-precision composite measurement in two dimensions (2D) , a new method is proposed in this paper which uses angle gauge blocks as standard artifacts to achieve coordinate unification between the image sensor and the tactile probe. By comparing the standard ball with the angle gauge block as a standard artifact, theoretical analysis and experimental results are given to prove that it is more precise and more convenient to use angle gauge blocks as standard artifacts to achieve coordinate unification of high-precision composite measurement in two dimensions. 展开更多
关键词 high-precision composite measurement image sensor tactile probe coordinate unification angle gauge block
下载PDF
4种植物源性成分多重real-time PCR检测方法的建立及其在食用淀粉中的应用 被引量:3
12
作者 范维 高晓月 +4 位作者 董雨馨 刘虹宇 李贺楠 赵文涛 郭文萍 《食品科学》 EI CAS CSCD 北大核心 2024年第1期210-216,共7页
建立一种可同时快速检测红薯、木薯、马铃薯、玉米源性成分的多重实时聚合酶链式反应(real-time polymerase chain reaction,real-time PCR)方法。分别以红薯g3pdh基因、木薯g3pdh基因、马铃薯UGPase基因、玉米zSSIIb基因为靶基因设计... 建立一种可同时快速检测红薯、木薯、马铃薯、玉米源性成分的多重实时聚合酶链式反应(real-time polymerase chain reaction,real-time PCR)方法。分别以红薯g3pdh基因、木薯g3pdh基因、马铃薯UGPase基因、玉米zSSIIb基因为靶基因设计特异性引物和TaqMan探针,以18S rRNA基因为内参基因,建立多重real-time PCR方法,开展方法学验证,并对不同掺入比例模拟样品和实际淀粉样品进行检测。结果显示,该方法具有高通量、特异性强、灵敏度高等优点。与15种非目标源性均无交叉反应;对目标DNA的检测灵敏度可达到3×10^(-3) ng/μL,且具有良好的线性关系和扩增效率;对淀粉样品的检出限可达0.1%,对50份实际样品进行检测,结果与参比方法一致,说明建立的多重real-time PCR法可用于食用淀粉种类掺假鉴别检测。 展开更多
关键词 多重实时聚合酶链式反应 食用淀粉 木薯 红薯 马铃薯 玉米
下载PDF
Moho depth inversion in the Tibetan Plateau from high-precision gravity data 被引量:4
13
作者 HuiYou He Jian Fang +3 位作者 HePing Sun DongMei Guo ZhiXin Xue Jing Hou 《Earth and Planetary Physics》 CAS CSCD 2023年第4期487-498,共12页
The Tibetan Plateau(TP)is the youngest orogenic belt resulting from a continental collision on the Earth.It is a natural laboratory for studying continental dynamics,such as continental convergence,plate subduction,an... The Tibetan Plateau(TP)is the youngest orogenic belt resulting from a continental collision on the Earth.It is a natural laboratory for studying continental dynamics,such as continental convergence,plate subduction,and plateau uplift.Investigating the deep structure of the TP has always been a popular issue in geological research.The Moho is the boundary between the crust and the mantle and therefore plays a crucial role in the Earth’s structure.Parameters such as depth and lateral variation,as well as the fine structure of the crust-mantle interface,reveal the lithospheric dynamics in the TP.Two methods are generally employed to study the Moho surface:seismic detection and gravity inversion.Seismic detection has the characteristic of high precision,but it is limited to a few cross-sectional lines and is quite costly.It is not suitable for and cannot be carried out over a large area of the TP.The Moho depth over a large area can be obtained through gravity inversion,but this method is affected by the nature of gravity data,and the accuracy of the inversion method is lower than that of seismic detection.In this work,a high-precision gravity field model was selected.The Parker-Oldenburg interface inversion method was used,within the constraints of seismic observations,and the Bott iteration method was introduced to enhance the inversion efficiency.The Moho depth in the TP was obtained with high precision,consistent with the seismic detection results.The research results showed that the shape of the Moho in the TP is complex and the variation range is large,reaching 60−80 km.In contrast with the adjacent area,a clear zone of sharp variation appears at the edge of the plateau.In the interior of the TP,the buried depth of the Moho is characterized by two depressions and two uplifts.To the south of the Yarlung Zangbo River,the Moho inclines to the north,and to the north,the Moho depresses downward,which was interpreted as the Indian plate subducting to the north below Tibet.The Moho depression on the north side of the Qiangtang block,reaching 72 km deep,may be a result of the southward subduction of the lithosphere.The Moho uplift of the Qiangtang block has the same strike as the Bangong−Nujiang suture zone,which may indicate that the area is compensated by a low-density and low-velocity mantle. 展开更多
关键词 GRAVITY MOHO Tibetan Plateau SGG-UGM-2(2159-order high-precision gravity field model)
下载PDF
High-precision nonisothermal transient wellbore drift flow model suitable for the full flow pattern domain and full dip range 被引量:2
14
作者 Wen-Qiang Lou Da-Lin Sun +5 位作者 Xiao-Hui Sun Peng-Fei Li Ya-Xin Liu Li-Chen Guan Bao-Jiang Sun Zhi-Yuan Wang 《Petroleum Science》 SCIE EI CAS CSCD 2023年第1期424-446,共23页
A reliable multiphase flow simulator is an important tool to improve wellbore integrity and production decision-making.To develop a multiphase flow model with high adaptability and high accuracy,we first build a multi... A reliable multiphase flow simulator is an important tool to improve wellbore integrity and production decision-making.To develop a multiphase flow model with high adaptability and high accuracy,we first build a multiphase flow database with 3561 groups of data and developed a drift closure relationship with stable continuity and high adaptability.Second,a high-order numerical scheme with strong fault capture ability is constructed by effectively combining MUSCL technology,van Albada slope limiter and AUSMV numerical scheme.Finally,the energy equation is coupled into the AUSMV numerical scheme of the drift flow model in the form of finite difference.A transient non-isothermal wellbore multiphase flow model with wide applicability is formed by integrating the three technologies,and the effects of various factors on the calculation accuracy are studied.The accuracy of the simulator is verified by comparing the measurement results with the blowout experiment of a full-scale experimental well. 展开更多
关键词 Drift closure relation Non-isothermal model high-precision Multiphase flow solver Wellbore pressure control
下载PDF
Research on the principle of space high-precision temperature control system of liquid crystals based Stokes polarimeter 被引量:1
15
作者 Xin-Wei Zhang Yang Zhang +2 位作者 Jia-Ben Lin Jun-Feng Hou Yuan-Yong Deng 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第1期97-104,共8页
The magnetic field is one of the most important parameters in solar physics,and a polarimeter is the key device to measure the solar magnetic field.Liquid crystals based Stokes polarimeter is a novel technology,and wi... The magnetic field is one of the most important parameters in solar physics,and a polarimeter is the key device to measure the solar magnetic field.Liquid crystals based Stokes polarimeter is a novel technology,and will be applied for magnetic field measurement in the first space-based solar observatory satellite developed by China,Advanced Space-based Solar Observatory.However,the liquid crystals based Stokes polarimeter in space is not a mature technology.Therefore,it is of great scientific significance to study the control method and characteristics of the device.The retardation produced by a liquid crystal variable retarder is sensitive to the temperature,and the retardation changes 0.09°per 0.10℃.The error in polarization measurement caused by this change is 0.016,which affects the accuracy of magnetic field measurement.In order to ensure the stability of its performance,this paper proposes a high-precision temperature control system for liquid crystals based Stokes polarimeter in space.In order to optimize the structure design and temperature control system,the temperature field of liquid crystals based Stokes polarimeter is analyzed by the finite element method,and the influence of light on the temperature field of the liquid crystal variable retarder is analyzed theoretically.By analyzing the principle of highprecision temperature measurement in space,a high-precision temperature measurement circuit based on integrated operational amplifier,programmable amplifier and 12 bit A/D is designed,and a high-precision space temperature control system is developed by applying the integral separation PI temperature control algorithm and PWM driving heating films.The experimental results show that the effect of temperature control is accurate and stable,whenever the liquid crystals based Stokes polarimeter is either in the air or vacuum.The temperature stability is within±0.0150℃,which demonstrates greatly improved stability for the liquid crystals based Stokes polarimeter. 展开更多
关键词 liquid crystals based Stokes polarimeter high-precision temperature measurement space high-precision temperature control temperature field analysis PID control
下载PDF
A Design of High-precision High-Voltage Fiber-Optic Analog Signal Isolation Converter 被引量:1
16
作者 李建伟 许留伟 +1 位作者 刘小宁 杨雷 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第3期1281-1287,共7页
This paper introduces a design of high-precision high-voltage fiber-optic analog sig-nal isolation converter based on the technology of Voltage-to-Frequency (V/F) and Frequency-to-Voltage (F/V) conversion. It describe... This paper introduces a design of high-precision high-voltage fiber-optic analog sig-nal isolation converter based on the technology of Voltage-to-Frequency (V/F) and Frequency-to-Voltage (F/V) conversion. It describes the principle, system configuration and hardware design. 展开更多
关键词 In DESIGN A Design of high-precision High-Voltage Fiber-Optic Analog Signal Isolation Converter FVC VFC
下载PDF
Real-Time Timing Channel Detection in a Software-Defined Networking Virtual Environment 被引量:2
17
作者 Anyi Liu Jim X. Chen Harry Wechsler 《Intelligent Information Management》 2015年第6期283-302,共20页
Despite extensive research, timing channels (TCs) are still known as a principal category of threats that aim to leak and transmit information by perturbing the timing or ordering of events. Existing TC detection appr... Despite extensive research, timing channels (TCs) are still known as a principal category of threats that aim to leak and transmit information by perturbing the timing or ordering of events. Existing TC detection approaches use either signature-based approaches to detect known TCs or anomaly-based approach by modeling the legitimate network traffic in order to detect unknown TCs. Un-fortunately, in a software-defined networking (SDN) environment, most existing TC detection approaches would fail due to factors such as volatile network traffic, imprecise timekeeping mechanisms, and dynamic network topology. Furthermore, stealthy TCs can be designed to mimic the legitimate traffic pattern and thus evade anomalous TC detection. In this paper, we overcome the above challenges by presenting a novel framework that harnesses the advantages of elastic re-sources in the cloud. In particular, our framework dynamically configures SDN to enable/disable differential analysis against outbound network flows of different virtual machines (VMs). Our framework is tightly coupled with a new metric that first decomposes the timing data of network flows into a number of using the discrete wavelet-based multi-resolution transform (DWMT). It then applies the Kullback-Leibler divergence (KLD) to measure the variance among flow pairs. The appealing feature of our approach is that, compared with the existing anomaly detection approaches, it can detect most existing and some new stealthy TCs without legitimate traffic for modeling, even with the presence of noise and imprecise timekeeping mechanism in an SDN virtual environment. We implement our framework as a prototype system, OBSERVER, which can be dynamically deployed in an SDN environment. Empirical evaluation shows that our approach can efficiently detect TCs with a higher detection rate, lower latency, and negligible performance overhead compared to existing approaches. 展开更多
关键词 Covert CHANNEL timing CHANNEL INTRUSION Detection VIRTUALIZATION Software-Defined Network
下载PDF
End-to-end learning for high-precision lane keeping via multi-state model 被引量:2
18
作者 Wei Yuan Ming Yang +2 位作者 Hao Li Chunxiang Wang Bing Wang 《CAAI Transactions on Intelligence Technology》 2018年第4期185-190,共6页
High-precision lane keeping is essential for the future autonomous driving.However,due to the imbalanced and inaccurate datasets collected by human drivers,current end-to-end driving models have poor lane keeping the ... High-precision lane keeping is essential for the future autonomous driving.However,due to the imbalanced and inaccurate datasets collected by human drivers,current end-to-end driving models have poor lane keeping the effect.To improve the precision of lane keeping,this study presents a novel multi-state model-based end-to-end lane keeping method.First,three driving states will be defined:going straight,turning right and turning left.Second,the finite-state machine(FSM)table as well as three kinds of training datasets will be generated based on the three driving states.Instead of collecting the dataset by human drivers,the accurate dataset will be collected by the high-performance path following controller.Third,three sets of parameters based on 3DCNN-LSTM model will be trained for going straight,turning left and turning right,which will be combined with FSM table to form a multi-state model.This study evaluates the multi-state model by testing it on five tracks and recording the lane keeping error.The result shows the multi-state model-based end-to-end method performs the higher precision of lane keeping than the traditional single end-to-end model. 展开更多
关键词 high-precision LANE keeping
下载PDF
Multi-channel & high-precision data acquisition devi ce for aerospace 被引量:1
19
作者 郑永秋 任勇峰 +1 位作者 刘鑫 储成群 《Journal of Measurement Science and Instrumentation》 CAS 2013年第2期184-189,共6页
This paper describes the detailed desi gn of data acquisition device with multi-channel and high-precision for aerosp ace.Based on detailed analysis of the advantages and disadvantages of tw o common acquisition circu... This paper describes the detailed desi gn of data acquisition device with multi-channel and high-precision for aerosp ace.Based on detailed analysis of the advantages and disadvantages of tw o common acquisition circuits,the design factors of acquisition device focus o n accuracy,sampling rate,hardware overhead and design space.The me chanical structure of the system is divided into different card layers according to different functions and the structure has the characteristics of high reliability,conveni ence to install and scalability.To ens ure reliable operation mode,the interface uses the optocoupler isolated from th e e xternal circuit.The transmission of signal is decided by the current in the cur rent loop that consists of optocouplers between acquisition device and t est bench.In multi-channel switching circuit,by establ ishing analog multiplexer model,the selection principles of circuit modes are given. 展开更多
关键词 data acquisition MULTI-CHANNEL high-precision analog multiplexer field-programmable gate array(FPGA)
下载PDF
A Timing Skew Calibration Scheme in Time-Interleaved ADC 被引量:1
20
作者 Jing Li Yang Liu +3 位作者 Hao Liu Shuangyi Wu Ning Ning Qi Yu 《Journal of Computer and Communications》 2013年第6期37-40,共4页
This paper proposes a digital background calibration scheme for timing skew in time-interleaved analog-to-digital converters (TIADCs). It detects the relevant timing error by subtracting the output difference with the... This paper proposes a digital background calibration scheme for timing skew in time-interleaved analog-to-digital converters (TIADCs). It detects the relevant timing error by subtracting the output difference with the sum of the first derivative of the digital output. The least-mean-square (LMS) loop is exploited to compensate the timing skew. Since the calibration scheme depends on the digital output, all timing skew sources can be calibrated and the main ADC is maintained. The proposed scheme is effective within the entire frequency range of 0 ? fs/2. Compared with traditional calibration schemes, the proposed approach is more feasible and consumes significantly lesser power and smaller area. 展开更多
关键词 timing SKEW BACKGROUND CALIBRATION Time-Interleaved Analog-to-Digital CONVERTERS
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部