期刊文献+
共找到321,941篇文章
< 1 2 250 >
每页显示 20 50 100
High-resolution imaging of magnetic fields of banknote anti-counterfeiting strip using fiber diamond probe
1
作者 赵旭彤 何飞越 +5 位作者 薛雅文 马文豪 殷筱晗 夏圣开 曾明菁 杜关祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期720-727,共8页
Counterfeiting of modern banknotes poses a significant challenge,prompting the use of various preventive measures.One such measure is the magnetic anti-counterfeiting strip.However,due to its inherent weak magnetic pr... Counterfeiting of modern banknotes poses a significant challenge,prompting the use of various preventive measures.One such measure is the magnetic anti-counterfeiting strip.However,due to its inherent weak magnetic properties,visualizing its magnetic distribution has been a longstanding challenge.In this work,we introduce an innovative method by using a fiber optic diamond probe,a highly sensitive quantum sensor designed specifically for detecting extremely weak magnetic fields.We employ this probe to achieve high-resolution imaging of the magnetic fields associated with the RMB 50denomination anti-counterfeiting strip.Additionally,we conduct computer simulations by using COMSOL Multiphysics software to deduce the potential geometric characteristics and material composition of the magnetic region within the anti-counterfeiting strip.The findings and method presented in this study hold broader significance,extending the RMB 50 denomination to various denominations of the Chinese currency and other items that employ magnetic anti-counterfeiting strips.These advances have the potential to significantly improve and promote security measures in order to prevent the banknotes from being counterfeited. 展开更多
关键词 banknote anti-counterfeiting strip nitrogen-vacancy(NV)centers magnetic field imaging numerical simulation
下载PDF
A fast decoupled ISAR high-resolution imaging method using structural sparse information under low SNR 被引量:6
2
作者 XIANG Long LI Shaodong +2 位作者 YANG Jun CHEN Wenfeng XIANG Hu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第3期492-503,共12页
Inverse synthetic aperture radar (ISAR) image can be represented and reconstructed by sparse recovery (SR) approaches. However, the existing SR algorithms, which are used for ISAR imaging, have suffered from high comp... Inverse synthetic aperture radar (ISAR) image can be represented and reconstructed by sparse recovery (SR) approaches. However, the existing SR algorithms, which are used for ISAR imaging, have suffered from high computational cost and poor imaging quality under a low signal to noise ratio (SNR) condition. This paper proposes a fast decoupled ISAR imaging method by exploiting the inherent structural sparse information of the targets. Firstly, the ISAR imaging problem is decoupled into two sub-problems. One is range direction imaging and the other is azimuth direction focusing. Secondly, an efficient two-stage SR method is proposed to obtain higher resolution range profiles by using jointly sparse information. Finally, the residual linear Bregman iteration via fast Fourier transforms (RLBI-FFT) is proposed to perform the azimuth focusing on low SNR efficiently. Theoretical analysis and simulation results show that the proposed method has better performence to efficiently implement higher-resolution ISAR imaging under the low SNR condition. 展开更多
关键词 SPARSE recovery inverse synthetic APERTURE radar (ISAR) imaging high-resolution signal to noise ratio (SNR) STRUCTURAL SPARSE INFORMATION
下载PDF
Research on monopulse forward-looking high-resolution imaging algorithm based on adaptive iteration 被引量:1
3
作者 Cheng Cheng Xiao-dong Zhou +3 位作者 Min Gao Zhu-lin Zong Yong-xiang Ji Bo Yu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2020年第1期158-171,共14页
In this paper,we proposed a monopulse forward-looking high-resolution imaging algorithm based on adaptive iteration for missile-borne detector.Through iteration,the proposed algorithm automatically selects the echo si... In this paper,we proposed a monopulse forward-looking high-resolution imaging algorithm based on adaptive iteration for missile-borne detector.Through iteration,the proposed algorithm automatically selects the echo signal of isolated strong-scattering points from the receiving echo signal data to accurately estimate the actual optimal monopulse response curve(MRC) of the same distance range,and we applied optimal MRC to realize the azimuth self-focusing in the process of imaging.We use real-time echo data to perform error correction for obtaining the optimal MRC,and the azimuth angulation accuracy may reach the optimum at a certain distance dimension.We experimentally demonstrate the validity,reliability and high performance of the proposed algorithm.The azimuth angulation accuracy may reach up to ten times of the detection beam-width.The simulation experiments have verified the feasibility of this strategy,with the average height measurement error being 7.8%.In the out-field unmanned aerial vehicle(UAV) tests,the height measurement error is less than 25 m,and the whole response time can satisfy the requirements of a missile-borne detector. 展开更多
关键词 MONOPULSE imaging high-resolution Adaptive ITERATION MISSILE-BORNE DETECTOR
下载PDF
Near field 3-D imaging approach for joint high-resolution imaging and phase error correction 被引量:2
4
作者 Yang Fang Baoping Wang +2 位作者 Chao Sun Zuxun Song Shuzhen Wang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2017年第2期199-211,共13页
This paper combines compressed sensing (CS) imaging theory and range migration algorithm (RMA), and then proposes a near-field three-dimensional (3-D) imaging approach for joint high-resolution imaging and phase error... This paper combines compressed sensing (CS) imaging theory and range migration algorithm (RMA), and then proposes a near-field three-dimensional (3-D) imaging approach for joint high-resolution imaging and phase error correction. Firstly, a sparse measurement matrix construction method based on a logistic sequence is proposed, which conducts nonlinear transformation for the determined logistic sequence, making it obey uniform distribution, then conducts sign function mapping, and generates the pseudorandom sequence with Bernoulli distribution, thus leading to good signal recovery under down-sampling and easy availability for engineering realization. Secondly, in combination with the RMA imaging approach, the dictionary with all scene information and phase error correction is constructed for CS signal recovery and error correction. Finally, the non-quadratic solution model jointing imaging and phase error correction based on regularization is built, and it is solved by two steps - the separable surrogate functionals (SSF) iterative shrinkage algorithm is adopted to realize target scattering estimate; the iteration mode is adopted for the correction of the dictionary model, so as to achieve the goal of error correction and highly-focused imaging. The proposed approach proves to be effective through numerical simulation and real measurement in anechoic chamber. The results show that, the proposed approach can realize high-resolution imaging in the case of less data; the designed measurement matrix has better non-coherence and easy availability for engineering realization. The proposed approach can effectively correct the phase error, and achieve highly-focused target image. ? 2017 Beijing Institute of Aerospace Information. 展开更多
关键词 Compressed sensing Error correction image reconstruction Iterative methods Linear transformations Mathematical transformations Signal reconstruction Signal sampling
下载PDF
High-resolution Imaging of Living Retina through Optic Adaptive Retinal Imaging System 被引量:5
5
作者 ChunhuiJiang NingLing 《眼科学报》 2002年第3期131-135,共5页
Purpose: To evaluate the possibility as well as the usage of adaptive optics in high-resolution retinal imaging.Methods:From March to November 2001, the fundus of 25 adults were checked by using Optic Adaptive Retinal... Purpose: To evaluate the possibility as well as the usage of adaptive optics in high-resolution retinal imaging.Methods:From March to November 2001, the fundus of 25 adults were checked by using Optic Adaptive Retinal Imaging System (OAS). The age of the subjects varied from 18~48 years. All had normal visual acuity from 0.9 to 1.0. No abnormality was found in the ocular examination, and their medical as well as ocular history was unremarkable. Results: High-resolution images of the retinal cells, photoreceptor and bipolar cell, were analysed. In these images, the cells are clearly resolved. The density of the photoreceptor at area 1.5 degree from the foveloa is around 40 000~50 000/mm2. At area 3 degree, it drops to less than 30 000/mm2.Conclusion:Optic Adaptive Retinal Imaging System (AOS) is able to get high-resolution image of retinal cells in living human eyes. It may be widely used in ophthalmology experimentally and clinically. 展开更多
关键词 适应性光学系统 视网膜 高分辨率成像
下载PDF
Investigating the relationship between intracranial atherosclerotic plaque remodelling and diabetes using high-resolution vessel wall imaging
6
作者 Yong-Qian Mo Hai-Yu Luo +5 位作者 Han-Wen Zhang Yu-Feng Liu Kan Deng Xiao-Lei Liu Biao Huang Fan Lin 《World Journal of Diabetes》 SCIE 2024年第1期72-80,共9页
BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imag... BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imaging(HR-VWI).AIM To investigate the factors of intracranial atherosclerotic remodelling patterns and the relationship between intracranial atherosclerotic remodelling and diabetes mellitus using HR-VWI.METHODS Ninety-four patients diagnosed with middle cerebral artery or basilar artery INTRODUCTION Intracranial atherosclerotic disease is one of the main causes of ischaemic stroke in the world,accounting for approx-imately 10%of transient ischaemic attacks and 30%-50%of ischaemic strokes[1].It is the most common factor among Asian people[2].The adaptive changes in the structure and function of blood vessels that can adapt to changes in the internal and external environment are called vascular remodelling,which is a common and important pathological mechanism in atherosclerotic diseases,and the remodelling mode of atherosclerotic plaques is closely related to the occurrence of stroke.Positive remodelling(PR)is an outwards compensatory remodelling where the arterial wall grows outwards in an attempt to maintain a constant lumen diameter.For a long time,it was believed that the degree of stenosis can accurately reflect the risk of ischaemic stroke[3-5].Previous studies have revealed that lesions without significant luminal stenosis can also lead to acute events[6,7],as summarized in a recent meta-analysis study in which approximately 50%of acute/subacute ischaemic events were due to this type of lesion[6].Research[8,9]has pointed out that the PR of plaques is more dangerous and more likely to cause acute ischaemic stroke.Previous studies[10-13]have found that there are specific vascular remodelling phenomena in the coronary and carotid arteries of diabetic patients.However,due to the deep location and small lumen of intracranial arteries and limitations of imaging techniques,the relationship between intracranial arterial remodelling and diabetes is still unclear.In recent years,with the development of magnetic resonance technology and the emergence of high-resolution(HR)vascular wall imaging,a clear and multidimensional display of the intracranial vascular wall has been achieved.Therefore,in this study,HR wall imaging(HR-VWI)was used to display the remodelling characteristics of bilateral middle cerebral arteries and basilar arteries and to explore the factors of intracranial vascular remodelling and its relationship with diabetes. 展开更多
关键词 high-resolution vessel wall imaging Intracranial atherosclerosis Vascular remodelling Magnetic resonance imaging
下载PDF
In vivo pilot study into superficial microcirculatory characteristics of colorectal adenomas using novel high-resolution magnifying endoscopy with blue laser imaging
7
作者 Hai-Bin Dong Tao Chen +2 位作者 Xiao-Fei Zhang Yu-Tang Ren Bo Jiang 《World Journal of Gastrointestinal Endoscopy》 2024年第4期206-213,共8页
BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a n... BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a novel high-resolution magnification endoscopy with blue laser imaging(BLI),thus providing a new insight into the microcirculation of early colon tumors.AIM To observe the superficial microcirculation of colorectal adenomas using the novel magnifying colonoscope with BLI and quantitatively analyzed the changes in hemodynamic parameters.METHODS From October 2019 to January 2020,11 patients were screened for colon adenomas with the novel high-resolution magnification endoscope with BLI.Video images were recorded and processed with Adobe Premiere,Adobe Photoshop and Image-pro Plus software.Four microcirculation parameters:Microcirculation vessel density(MVD),mean vessel width(MVW)with width standard deviation(WSD),and blood flow velocity(BFV),were calculated for adenomas and the surrounding normal mucosa.RESULTS A total of 16 adenomas were identified.Compared with the normal surrounding mucosa,the superficial vessel density in the adenomas was decreased(MVD:0.95±0.18 vs 1.17±0.28μm/μm2,P<0.05).MVW(5.11±1.19 vs 4.16±0.76μm,P<0.05)and WSD(11.94±3.44 vs 9.04±3.74,P<0.05)were both increased.BFV slowed in the adenomas(709.74±213.28 vs 1256.51±383.31μm/s,P<0.05).CONCLUSION The novel high-resolution magnification endoscope with BLI can be used for in vivo study of adenoma superficial microcirculation.Superficial vessel density was decreased,more irregular,with slower blood flow. 展开更多
关键词 ADENOMA MICROCIRCULATION high-resolution magnification endoscopy Blue laser imaging
下载PDF
High-Resolution Imaging of Latent Fingerprints through Near-Infrared Organoboron AIEgens
8
作者 Lijie Liu Jinjin Wang +11 位作者 Xingxiao Wang Haoran Wang Mengzhen Li Tongyuan Wu Guangqin Gao Xin Zheng Guoxing Liu Liangxin Fan Wenbo Shen Guangxin Ru Zheng Zhao Ben Zhong Tang 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2023年第12期1465-1470,共6页
A new class of near-infrared(NIR)fluorescent organoboron AIEgens was successfully developed for latent fingerprints(LFPs)imaging.They exhibit real-time and in situ high-resolution imaging performance at 1-3 levels of ... A new class of near-infrared(NIR)fluorescent organoboron AIEgens was successfully developed for latent fingerprints(LFPs)imaging.They exhibit real-time and in situ high-resolution imaging performance at 1-3 levels of LFPs by spraying method.In addition,we systematically elucidate the fingerprint imaging mechanism of these AIEgens.Significantly,the excellent level 3 structural imaging capabilities enable the application of them for analyzing incomplete LFPs and identifying individuals in different scenarios. 展开更多
关键词 Organoboron AIEgens Aggregation-induced emission Near-infrared emission high-resolution imaging of latent fingerprints
原文传递
High-resolution x-ray monochromatic imaging for laser plasma diagnostics based on toroidal crystal 被引量:2
9
作者 司昊轩 董佳钦 +3 位作者 方智恒 蒋励 伊圣振 王占山 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期181-186,共6页
Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for ... Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge(531)wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3-7μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility. 展开更多
关键词 laser plasma diagnostics toroidal crystal monochromatic x-ray imaging
下载PDF
High-resolution visible imaging with piezoelectric deformable secondary mirror: experimental results at the 1.8-m adaptive telescope 被引量:2
10
作者 Youming Guo Kele Chen +7 位作者 Jiahui Zhou Zhengdai Li Wenyu Han Xuejun Rao Hua Bao Jinsheng Yang Xinlong Fan Changhui Rao 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第12期15-26,共12页
Integrating deformable mirrors within the optical train of an adaptive telescope was one of the major innovations in astronomical observation technology,distinguished by its high optical throughput,reduced optical sur... Integrating deformable mirrors within the optical train of an adaptive telescope was one of the major innovations in astronomical observation technology,distinguished by its high optical throughput,reduced optical surfaces,and the incorporation of the deformable mirror.Typically,voice-coil actuators are used,which require additional position sensors,internal control electronics,and cooling systems,leading to a very complex structure.Piezoelectric deformable secondary mirror technologies were proposed to overcome these problems.Recently,a high-order piezoelectric deformable secondary mirror has been developed and installed on the 1.8-m telescope at Lijiang Observatory in China to make it an adaptive telescope.The system consists of a 241-actuator piezoelectric deformable secondary mirror,a 192-sub-aperture Shack-Hartmann wavefront sensor,and a multi-core-based real-time controller.The actuator spacing of the PDSM measures 19.3 mm,equivalent to approximately 12.6 cm when mapped onto the primary mirror,significantly less than the voicecoil-based adaptive telescopes such as LBT,Magellan and VLT.As a result,stellar images with Strehl ratios above 0.49 in the R band have been obtained.To our knowledge,these are the highest R band images captured by an adaptive telescope with deformable secondary mirrors.Here,we report the system description and on-sky performance of this adaptive telescope. 展开更多
关键词 adaptive optics deformable secondary mirror visible imaging
下载PDF
High-resolution seismicity imaging and early aftershock migration of the 2023 Kahramanmara?(SE Türkiye)M_W7.9&7.8 earthquake doublet 被引量:1
11
作者 Hongyang Ding Yijian Zhou +5 位作者 Zengxi Ge Tuncay Taymaz Abhijit Ghosh Haoyu Xu Tahir Serkan Irmak Xiaodong Song 《Earthquake Science》 2023年第6期417-432,共16页
We build a high-resolution early aftershock catalog for the 2023 SE Türkiye seismic sequence with PALM,a seamless workflow that sequentially performs phase picking,association,location,and matched filter for cont... We build a high-resolution early aftershock catalog for the 2023 SE Türkiye seismic sequence with PALM,a seamless workflow that sequentially performs phase picking,association,location,and matched filter for continuous data.The catalog contains 29,519 well-located events in the two mainshocks rupture region during 2023-02-01–2023-02-28,which significantly improves the detection completeness and relocation precision compared to the public routine catalog.Employing the new PALM catalog,we analyze the structure of the seismogenic fault system.We find that the Eastern Anatolian Fault(EAF)that generated the first M_(W)7.9 mainshock is overall near-vertical,whereas complexities are revealed in a small-scale,such as subparallel subfaults,unmapped branches,and stepovers.The seismicity on EAF is shallow(<15 km)and concentrated in depth distribution,indicating a clear lock-creep transition.In contrast,the SürgüFault(SF)that is responsible for the second M_(W)7.8 mainshock is shovel-shaped for the nucleation segment and has overall low dip angles(~40°–80°).Aftershocks on the SF distribute in a broad range of depth,extending down to~35 km.We also analyze the temporal behavior of seismicity,discovering no immediate foreshocks within~5 days preceding the first mainshock,and no seismic activity on the SF before the second mainshock. 展开更多
关键词 2023 Türkiye Earthquake Doublet aftershock catalog PALM fault imaging aftershock migration
下载PDF
Combining High-Resolution Imaging,Deep Learning,and Dynamic Modeling to Separate Disease and Senescence in Wheat Canopies
12
作者 Jonas Anderegg Radek Zenkl +1 位作者 Achim Walter Andreas Hund 《Plant Phenomics》 SCIE EI CSCD 2023年第2期295-312,共18页
Maintenance of sufficiently healthy green leaf area after anthesis is key to ensuring an adequate assimilate supply for grain filling.Tightly regulated age-related physiological senescence and various biotic and abiot... Maintenance of sufficiently healthy green leaf area after anthesis is key to ensuring an adequate assimilate supply for grain filling.Tightly regulated age-related physiological senescence and various biotic and abiotic stressors drive overall greenness decay dynamics under field conditions.Besides direct effects on green leaf area in terms of leaf damage,stressors often anticipate or accelerate physiological senescence,which may multiply their negative impact on grain filling.Here,we present an image processing methodology that enables the monitoring of chlorosis and necrosis separately for ears and shoots(stems+leaves)based on deep learning models for semantic segmentation and color properties of vegetation.A vegetation segmentation model was trained using semisynthetic training data generated using image composition and generative adversarial neural networks,which greatly reduced the risk of annotation uncertainties and annotation effort.Application of the models to image time series revealed temporal patterns of greenness decay as well as the relative contributions of chlorosis and necrosis.Image-based estimation of greenness decay dynamics was highly correlated with scoring-based estimations(r≈0.9).Contrasting patterns were observed for plots with different levels of foliar diseases,particularly septoria tritici blotch.Our results suggest that tracking the chlorotic and necrotic fractions separately may enable(a)a separate quantification of the contribution of biotic stress and physiological senescence on overall green leaf area dynamics and(b)investigation of interactions between biotic stress and physiological senescence.The high-throughput nature of our methodology paves the way to conducting genetic studies of disease resistance and tolerance. 展开更多
关键词 WHEAT enable imagE
原文传递
Ultra-thin temperature controllable microwell array chip for continuous real-time high-resolution imaging of living single cells
13
作者 Yuanyuan Wu Lei Zhao +3 位作者 Yaran Chang Liang Zhao Guangsheng Guo Xiayan Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2021年第11期3446-3449,共4页
Single-cell imaging,a powerful analytical method to study single-cell behavior,such as gene expression and protein profiling,provides an essential basis for modern medical diagnosis.The coding and localization functio... Single-cell imaging,a powerful analytical method to study single-cell behavior,such as gene expression and protein profiling,provides an essential basis for modern medical diagnosis.The coding and localization function of microfluidic chips has been developed and applied in living single-cell imaging in recent years.Simultaneously,chip-based living single-cell imaging is also limited by complicated trapping steps,low cell utilization,and difficult high-resolution imaging.To solve these problems,an ultra-thin temperature-controllable microwell array chip(UTCMA chip)was designed to develop a living single-cell workstation in this study for continuous on-chip culture and real-time high-resolution imaging of living single cells.The chip-based on ultra-thin ITO glass is highly matched with an inverted microscope(or confocal microscope)with a high magnification objective(100×oil lens),and the temperature of the chip can be controlled by combining it with a home-made temperature control device.High-throughput single-cell patterning is realized in one step when the microwell array on the chip uses hydrophilic glass as the substrate and hydrophobic SU-8 photoresist as the wall.The cell utilization rate,single-cell capture rate,and microwell occupancy rate are all close to 100%in the microwell array.This method will be useful in rare single-cell research,extending its application in the biological and medical-related fields,such as early diagnosis of disease,personalized therapy,and research-based on single-cell analysis. 展开更多
关键词 Ultra-thin microchip Temperature controllable Living single cells One-step patterning Continuous culture high-resolution imaging
原文传递
Operation Control of a High-resolution Plasma Imaging System in KT5D Torus
14
作者 孙翔 许敏 +9 位作者 余羿 闻一之 俞昌旋 马锦绣 王之江 陆荣华 王俊 朱振华 前川孝 打田 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期2999-3001,共3页
This paper describes the control software together with the operational hardware, which successfully realizes the operation of a new fully programmable imaging system with high spatial and temporal resolutions on the ... This paper describes the control software together with the operational hardware, which successfully realizes the operation of a new fully programmable imaging system with high spatial and temporal resolutions on the KT5D magnetic torus, for observing the visible l ight emission from the plasma discharge. 展开更多
关键词 magnetically confined plasma high-resolution imaging programmable hard-ware operation control software
下载PDF
Exploratory study of non-invasive,high-resolution functional macular imaging in subjects with diabetic retinopathy
15
作者 Thalmon R.Campagnoli Gábor Márk Somfai +2 位作者 Jing Tian Delia Cabrera DeBuc William E.Smiddy 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第1期57-63,共7页
AIM:To evaluate a high-resolution functional imaging device that yields quantitative data regarding macular blood flow and capillary network features in eyes with diabetic retinopathy(DR).METHODS:Prospective,cross-sec... AIM:To evaluate a high-resolution functional imaging device that yields quantitative data regarding macular blood flow and capillary network features in eyes with diabetic retinopathy(DR).METHODS:Prospective,cross-sectional comparative case-series in which blood flow velocities(BFVs)and noninvasive capillary perfusion maps(nCPMs)in macular vessels were measured in patients with DR and in healthy controls using the Retinal Functional Imager(RFI)device.RESULTS:A total of 27 eyes of 21 subjects were studied[9 eyes nonproliferative diabetic retinopathy(NPDR),9 eyes proliferative diabetic retinopathy(PDR)and 9 controls].All diabetic patients were type 2.All patients with NPDR and 5 eyes with PDR also had diabetic macular edema(DME).The NPDR group included eyes with severe(n=3)and moderate NPDR(n=6),and were symptomatic.A significant decrease in venular BFVs was observed in the macular region of PDR eyes when compared to controls(2.61±0.6 mm/s and 2.92±0.72 mm/s in PDR and controls,respectively,P=0.019)as well as PDR eyes with DME compared to NPDR eyes(2.36±0.51 mm/s and 2.94±1.09 mm/s in PDR with DME and NPDR,respectively,P=0.01).CONCLUSION:The RFI,a non-invasive imaging tool,provides high-resolution functional imaging of the retinal microvasculature and quantitative measurement of BFVs in visually impaired DR patients.The isolated diminish venular BFVs in PDR eyes compared to healthy eyes and PDR eyes with DME in comparison to NPDR eyes may indicate the possibility of more retinal vein compromise than suspected in advanced DR. 展开更多
关键词 macular blood flow capillary perfusion map non-invasive vascular imaging high-resolution imaging diabetic retinopathy retinal function imager
下载PDF
Verification and Validation of High-Resolution Inviscid and Viscous Conical Nozzle Flows
16
作者 Luciano K.Araki Rafael B.de R.Borges +1 位作者 Nicholas Dicati P.da Silva Chi-Wang Shu 《Communications on Applied Mathematics and Computation》 EI 2024年第1期533-549,共17页
Capturing elaborated flow structures and phenomena is required for well-solved numerical flows.The finite difference methods allow simple discretization of mesh and model equations.However,they need simpler meshes,e.g... Capturing elaborated flow structures and phenomena is required for well-solved numerical flows.The finite difference methods allow simple discretization of mesh and model equations.However,they need simpler meshes,e.g.,rectangular.The inverse Lax-Wendroff(ILW)procedure can handle complex geometries for rectangular meshes.High-resolution and high-order methods can capture elaborated flow structures and phenomena.They also have strong mathematical and physical backgrounds,such as positivity-preserving,jump conditions,and wave propagation concepts.We perceive an effort toward direct numerical simulation,for instance,regarding weighted essentially non-oscillatory(WENO)schemes.Thus,we propose to solve a challenging engineering application without turbulence models.We aim to verify and validate recent high-resolution and high-order methods.To check the solver accuracy,we solved vortex and Couette flows.Then,we solved inviscid and viscous nozzle flows for a conical profile.We employed the finite difference method,positivity-preserving Lax-Friedrichs splitting,high-resolution viscous terms discretization,fifth-order multi-resolution WENO,ILW,and third-order strong stability preserving Runge-Kutta.We showed the solver is high-order and captured elaborated flow structures and phenomena.One can see oblique shocks in both nozzle flows.In the viscous flow,we also captured a free-shock separation,recirculation,entrainment region,Mach disk,and the diamond-shaped pattern of nozzle flows. 展开更多
关键词 high-resolution COMPRESSIBLE NAVIER-STOKES Free-shock separation Nozzle flow
下载PDF
A synthetic diagnostics platform for microwave imaging diagnostics in tokamaks
17
作者 李子涵 杨尚川 +5 位作者 徐新航 张立夫 渠承明 李诚普 庄革 谢锦林 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期38-45,共8页
Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee... Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering. 展开更多
关键词 synthetic diagnostics tokamak plasmas microwave imaging diagnostics microwave imaging reflectometer electron cyclotron emission imaging
下载PDF
Self-confocal NIR-II fluorescence microscopy for multifunctional in vivo imaging
18
作者 Jing Zhou Tianxiang Wu +5 位作者 Runze Chen Liang Zhu Hequn Zhang Yifei Li Liying Chen Jun Qian 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期105-119,共15页
Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imagi... Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imaging with high spatial resolution.However,the traditional NIR-IIfluorescence confocal microscope with separate excitation focus and detection pinhole makes it possess low confocal e±ciency,as well as di±cultly to adjust.Two types of upgraded NIR-IIfluorescence confocal microscopes,sharing the same pinhole by excitation and emission focus,leading to higher confocal e±ciency,are built in this work.One type is-ber-pinhole-based confocal microscope applicable to CW laser excitation.It is constructed forfluorescence intensity imaging with large depth,high stabilization and low cost,which could replace multiphotonfluorescence microscopy in some applications(e.g.,cerebrovascular and hepatocellular imaging).The other type is air-pinhole-based confocal microscope applicable to femtosecond(fs)laser excitation.It can be employed not only for NIR-IIfluorescence intensity imaging,but also for multi-channelfluorescence lifetime imaging to recognize different structures with similarfluorescence spectrum.Moreover,it can be facilely combined with multiphotonfluorescence microscopy.A single fs pulsed laser is utilized to achieve up-conversion(visible multiphotonfluorescence)and down-conversion(NIR-II one-photonfluorescence)excitation simultaneously,extending imaging spectral channels,and thus facilitates multi-structure and multi-functional observation. 展开更多
关键词 Self-confocal fiber-pinhole air-pinhole multi-channe fluorescence lifetime imaging multi-color imaging
下载PDF
Microwave-induced thermoacoustic elastic imaging:A simulation study
19
作者 Lin Huang Zheng Liang +1 位作者 Shuaiqi Qiao Weipeng Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第2期1-11,共11页
Microwave-induced thermoacoustic imaging(MTI)has the advantages of high resolution,high contrast,non-ionization,and non-invasive.Recently,MTI was used in the¯eld of breast cancer screening.In this paper,based on ... Microwave-induced thermoacoustic imaging(MTI)has the advantages of high resolution,high contrast,non-ionization,and non-invasive.Recently,MTI was used in the¯eld of breast cancer screening.In this paper,based on the¯nite element method(FEM)and COMSOL Multiphysics software,a three-dimensional breast cancer model suitable for exploring the MTI process is proposed to investigate the in°uence of Young's modulus(YM)of breast cancer tissue on MTI.It is found that the process of electromagnetic heating and initial pressure generation of the entire breast tissue is earlier in time than the thermal expansion process.Besides,compared with normal breast tissue,tumor tissue has a greater temperature rise,displacement,and pressure rise.In particular,YM of the tumor is related to the speed of thermal expansion.In particular,the larger the YM of the tumor is,the higher the heating and contraction frequency is,and the greater the maximum pressure is.Di®erent Young's moduli correspond to di®erent thermoacoustic signal spectra.In MTI,this study can be used to judge di®erent degrees of breast cancer based on elastic imaging.In addition,this study is helpful in exploring the possibility of microwave-induced thermoacoustic elastic imaging(MTAE). 展开更多
关键词 Thermoacoustic imaging breast cancer multi-physics simulation elastic imaging
下载PDF
Topic highlight on texture and color enhancement imaging in gastrointestinal diseases
20
作者 Osamu Toyoshima Toshihiro Nishizawa Keisuke Hata 《World Journal of Gastroenterology》 SCIE CAS 2024年第14期1934-1940,共7页
Olympus Corporation developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.This topic highlights a series of hot-topic articles that investigated the efficacy of TXI for ga... Olympus Corporation developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.This topic highlights a series of hot-topic articles that investigated the efficacy of TXI for gastrointestinal disease identification in the clinical setting.A randomized controlled trial demonstrated improvements in the colorectal adenoma detection rate(ADR)and the mean number of adenomas per procedure(MAP)of TXI compared with those of white-light imaging(WLI)observation(58.7%vs 42.7%,adjusted relative risk 1.35,95%CI:1.17-1.56;1.36 vs 0.89,adjusted incident risk ratio 1.48,95%CI:1.22-1.80,respectively).A cross-over study also showed that the colorectal MAP and ADR in TXI were higher than those in WLI(1.5 vs 1.0,adjusted odds ratio 1.4,95%CI:1.2-1.6;58.2%vs 46.8%,1.5,1.0-2.3,respectively).A randomized controlled trial demonstrated non-inferiority of TXI to narrow-band imaging in the colorectal mean number of adenomas and sessile serrated lesions per procedure(0.29 vs 0.30,difference for non-inferiority-0.01,95%CI:-0.10 to 0.08).A cohort study found that scoring for ulcerative colitis severity using TXI could predict relapse of ulcerative colitis.A cross-sectional study found that TXI improved the gastric cancer detection rate compared to WLI(0.71%vs 0.29%).A cross-sectional study revealed that the sensitivity and accuracy for active Helicobacter pylori gastritis in TXI were higher than those of WLI(69.2%vs 52.5%and 85.3%vs 78.7%,res-pectively).In conclusion,TXI can improve gastrointestinal lesion detection and qualitative diagnosis.Therefore,further studies on the efficacy of TXI in clinical practice are required. 展开更多
关键词 Endoscopy Texture and color enhancement imaging White-light imaging Narrow-band imaging Colorectal neoplasm Gastric cancer Adenoma Ulcerative colitis Helicobacter infections Colonoscopy
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部