Under harmonic wave excitation, the dynamic response of a bilinear SDOF system can be expressed by the Hilbert spectrum. The Hilbert spectrum can be formulated by (1) the inter-wave combination mechanism between the s...Under harmonic wave excitation, the dynamic response of a bilinear SDOF system can be expressed by the Hilbert spectrum. The Hilbert spectrum can be formulated by (1) the inter-wave combination mechanism between the steady response and the transient response when the system behaves linearly, or (2) the intra-wave modulation mechanism embedded in one intrinsic mode function (IMF) component when the system behaves nonlinearly. The temporal variation of the instantaneous frequency of the IMF component is consistent with the system nonlinear behavior of yielding and unloading. As a thorough study of this fundamental structural dynamics problem, this article investigates the influence of the amplitude of the harmonic wave excitation on the Hilbert spectrum and the intrinsic oscillatory mode of the dynamic response of a bilinear SDOF system.展开更多
为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流...为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流暂态过程频谱特性具有相似变化规律。以此为基础,应用生物电流信号高频IMF分量幅值的突变特征,作为触电故障时刻确定判据,建立生物触电故障时刻判定方法,实际数据的仿真处理正确率为94.17%;筛选剩余电流分解的相关性较高的有限个数的低频固有模态IMF分量,应用逐步多元线性回归方法,提出基于剩余电流固有模态分量的生物触电支路电流幅值检测方法,仿真试验结果的平均相对误差值5.46%,具有良好的适应性和实用性,为研发基于生物体触电电流而动作的剩余电流保护装置提供参考。展开更多
基金National Natural Science Foundation of China Under Grant No.50278090
文摘Under harmonic wave excitation, the dynamic response of a bilinear SDOF system can be expressed by the Hilbert spectrum. The Hilbert spectrum can be formulated by (1) the inter-wave combination mechanism between the steady response and the transient response when the system behaves linearly, or (2) the intra-wave modulation mechanism embedded in one intrinsic mode function (IMF) component when the system behaves nonlinearly. The temporal variation of the instantaneous frequency of the IMF component is consistent with the system nonlinear behavior of yielding and unloading. As a thorough study of this fundamental structural dynamics problem, this article investigates the influence of the amplitude of the harmonic wave excitation on the Hilbert spectrum and the intrinsic oscillatory mode of the dynamic response of a bilinear SDOF system.
文摘为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流暂态过程频谱特性具有相似变化规律。以此为基础,应用生物电流信号高频IMF分量幅值的突变特征,作为触电故障时刻确定判据,建立生物触电故障时刻判定方法,实际数据的仿真处理正确率为94.17%;筛选剩余电流分解的相关性较高的有限个数的低频固有模态IMF分量,应用逐步多元线性回归方法,提出基于剩余电流固有模态分量的生物触电支路电流幅值检测方法,仿真试验结果的平均相对误差值5.46%,具有良好的适应性和实用性,为研发基于生物体触电电流而动作的剩余电流保护装置提供参考。