A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the ne...A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324.展开更多
To achieve CO2 emissions reductions,the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as Sta...To achieve CO2 emissions reductions,the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as Standard Assessment Procedure(SAP 2005) or,more recently SAP 2009.SAP encompasses all domestic heat consumption and a limited proportion of the electricity consumption.However,these calculations are rarely verified with real energy consumption and related CO2 emissions.This work presents the results of an analysis based on weekly heat demand data for more than 200 individual flats.The data were collected from a recently built residential development connected to a district heating network.A method for separating out the domestic hot water(DHW) use and space heating(SH) demand has been developed and these values are compared to the demand calculated using SAP 2005 and SAP 2009 methodologies.The analysis also shows the variation in DHW and SH consumption with size of flats and with tenure(privately owned or social housing).Evaluation of the space heating consumption also includes an estimate of the heating degree day(HDD) base temperature for each block of flats and compares this to the average base temperature calculated using the SAP 2005 methodology.展开更多
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ...The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.展开更多
Corrosion has been reported to occur in the copper tubes of heat ex-changers in multiple-circulation hot water supply systems. We have been investigating the applicability of high-strength Cu-0.65 mass% Sn-0.014 mass%...Corrosion has been reported to occur in the copper tubes of heat ex-changers in multiple-circulation hot water supply systems. We have been investigating the applicability of high-strength Cu-0.65 mass% Sn-0.014 mass% Zr-0.020 mass% P alloy to counteract this corrosion. Immersion tests, electrochemical measurements, and field tests were performed. Excellent corrosion resistance of the alloy was established under conditions with flowing water due to the formation of composite films containing tin. The alloy is expected to be better than copper as a corrosion-resistant material for heat exchanger tubes.展开更多
基金Project(2010DFA72740-06) supported by International Science & Technology Cooperation Program of China
文摘A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324.
文摘To achieve CO2 emissions reductions,the UK Building Regulations require developers of new residential buildings to calculate expected CO2 emissions arising from their energy consumption using a methodology such as Standard Assessment Procedure(SAP 2005) or,more recently SAP 2009.SAP encompasses all domestic heat consumption and a limited proportion of the electricity consumption.However,these calculations are rarely verified with real energy consumption and related CO2 emissions.This work presents the results of an analysis based on weekly heat demand data for more than 200 individual flats.The data were collected from a recently built residential development connected to a district heating network.A method for separating out the domestic hot water(DHW) use and space heating(SH) demand has been developed and these values are compared to the demand calculated using SAP 2005 and SAP 2009 methodologies.The analysis also shows the variation in DHW and SH consumption with size of flats and with tenure(privately owned or social housing).Evaluation of the space heating consumption also includes an estimate of the heating degree day(HDD) base temperature for each block of flats and compares this to the average base temperature calculated using the SAP 2005 methodology.
文摘The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.
文摘Corrosion has been reported to occur in the copper tubes of heat ex-changers in multiple-circulation hot water supply systems. We have been investigating the applicability of high-strength Cu-0.65 mass% Sn-0.014 mass% Zr-0.020 mass% P alloy to counteract this corrosion. Immersion tests, electrochemical measurements, and field tests were performed. Excellent corrosion resistance of the alloy was established under conditions with flowing water due to the formation of composite films containing tin. The alloy is expected to be better than copper as a corrosion-resistant material for heat exchanger tubes.