期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Neutral-point-clamped hybrid multilevel converter with DC fault blocking capability for medium-voltage DC transmission 被引量:3
1
作者 Xinyu YU Yingdong WEI +3 位作者 Qirong JIANG Xiaorong XIE Yuquan LIU Ke WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期524-536,共13页
This paper proposes a novel hybrid multilevel converter with DC fault-blocking capability, i.e., the neutral-point clamped hybrid multilevel converter(NHMC).By employing two types of unipolar full-bridge submodules al... This paper proposes a novel hybrid multilevel converter with DC fault-blocking capability, i.e., the neutral-point clamped hybrid multilevel converter(NHMC).By employing two types of unipolar full-bridge submodules along with director switches, which are composed of seriesconnected insulated-gate bipolar transistors, the NHMC combines the features and advantages of the neutral-point clamped converter and the modular multilevel converter.The basic topology, operating principles, modulation scheme, and energy-balancing scheme of the NHMC are presented. The DC fault-blocking capability of the NHMC is investigated. The number of power electronic devices used by the NHMC is calculated and compared with other multilevel converters, showing that the proposed NHMC can be an economical and feasible option for medium-voltage DC transmission with overhead lines. Simulation results demonstrate the features and operating scheme of the proposed NHMC. 展开更多
关键词 Neutral-point-clamped hybrid multilevel converter(NHMC) Unipolar full-bridge submodule(UFBSM) DC fault blocking capability Modulation scheme
原文传递
A Model Predictive Control Method for Hybrid Energy Storage Systems 被引量:2
2
作者 Siyuan Chen Qiufan Yang +1 位作者 Jianyu Zhou Xia Chen 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第2期329-338,共10页
The traditional PI controller for a hybrid energy storage system(HESS)has certain drawbacks,such as difficult tuning of the controller parameters and the additional filters to allocate high-and low-frequency power flu... The traditional PI controller for a hybrid energy storage system(HESS)has certain drawbacks,such as difficult tuning of the controller parameters and the additional filters to allocate high-and low-frequency power fluctuations.This paper proposes a model predictive control(MPC)method to control three-level bidirectional DC/DC converters for grid-connections to a HESS in a DC microgrid.First,the mathematical model of a HESS consisting of a battery and ultra capacitor(UC)is established and the neutral point voltage imbalance of a three-level converter is solved by analyzing the operating modes of the converter.Secondly,for the control of the grid-connected converters,an MPC method is proposed for calculating steady-state reference values in the outer layer and the dynamic rolling optimization in the inner layer.The outer layer ensures the voltage regulation and establishes the current predictive model,while the inner layer,using the model predictive current control,makes the current follow the predictive value,thus reducing the system current ripple.This cascaded topology has two independent controllers and is free of filters to realize the high-and low-frequency power allocation for a HESS.Therefore,it allows two types of energy storage devices to independently regulate the voltage and realizes the power allocation of the battery and UC.Finally,simulation studies are conducted in PSCAD/EMTDC,and the effectiveness of the proposed HESS control strategy is verified in a case,such as a controller comparison and fault scenario. 展开更多
关键词 Double layer control method hybrid energy storage system(HESS) model predictive control(MPC) three-level DC/DC converter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部