A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier g...A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%.展开更多
A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The method is based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure...A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The method is based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure argon, and then swept to Ar-H2 flame quarts atomizer to measure its fluorescence intensity. The hydride generation, transportation, atomization and some instrumental parameters were studied by a kind of orthogonal design. The optimum conditions selected are as follows: reactive acidity, 20% HC1; the amount of NaBH4, 4.9mL; gas flow of argon, 600mLmin^-1; atomizing temperature, 200 ℃ ; negative high voltage, - 300V; light current, 100 mA; integral time, 7s. The detection limit of the presented method is 0.072μgL^-1 for selenium. The calibration curve shows a satisfactory line inthe concentration range from 0.000 to 1.000μgL^-1 Se. The recovery is 95.8%-102.2%.展开更多
0.2000g mogroside sample is digested by 7.0ml nitric acid and 3.0ml hydrogen peroxide, and generated by coprecipitation enrichment hydride - atomic fluorescence spectrometry determines trace selenium in it. Under opti...0.2000g mogroside sample is digested by 7.0ml nitric acid and 3.0ml hydrogen peroxide, and generated by coprecipitation enrichment hydride - atomic fluorescence spectrometry determines trace selenium in it. Under optimum experiment conditions, a standard curve was produced using selenium standard solution, the linear equation is Ise=2890.6c+0.0012,compared wish the linear relaticnship is not by coprecipitation direct determination of standard series Ise=82.56c+0.0018 Selenium detection sensitivity was increased by 35.01 times,the correlation coefficient of obtained linear regression equation is 0.9996, the detection limit is 0.0012~tg/L and the relative standard deviation is 0.76% (n=5). Containing 0.1808pg.g-1 Se Luo Han Shen samples. Based on mogroside sample, add a certain of standard solution to do recovery experiment, the obtained recovery rate is in 95.8%-103.6% and the result is satisfactory.展开更多
In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generat...In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generation atomic fluorescence spectrometry (HG-AFS) method, and distribution proportions of elements in four phases were calculated. This method was based on the reaction of cadmium with 1.5% (m/v) KBH4 solution and 0.5% KOH(m/v) solution to form the hydride gas in medium of 2% (v/v) HCl. The detection limit for cadmium as low as 0.008μg/L was obtained. The lineally correlation coefficient was 0.99992. The relative standard deviation (n=5, C=1.00μg/L) was 3.26%. The proposed method was applied for the determination of cadmium in atmosphere aerosol samples and the recoveries in the range of 95-102.2% were obtained. This method was simple, rapid, less matrix interference and high sensitivity.展开更多
Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was susp...Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was suspended in agar solution by an ultrasound water bath before the HG-AFS determination. The results for the reference material of soil (serial number GBW-07411) agreed satisfactorily with the certified values. Results obtained by the developed procedure compared well with those after traditional acid digestion of samples. The detection limit are 6.7ngL-1 for Hg respectively, with average relative standard deviation values of 6.4% for analysis of a series of soil samples of different origin. The recoveries of the anatytes varied in the range from 95 to 107%. This observation has stimulated interest in fast, accurate and sensitive analytical methods for determination of metals in soil.展开更多
基金supported by the Key Science and Technology pnasp Minsty of Educaton umder contr act(N0.200010-0079).
文摘A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%.
文摘A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The method is based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure argon, and then swept to Ar-H2 flame quarts atomizer to measure its fluorescence intensity. The hydride generation, transportation, atomization and some instrumental parameters were studied by a kind of orthogonal design. The optimum conditions selected are as follows: reactive acidity, 20% HC1; the amount of NaBH4, 4.9mL; gas flow of argon, 600mLmin^-1; atomizing temperature, 200 ℃ ; negative high voltage, - 300V; light current, 100 mA; integral time, 7s. The detection limit of the presented method is 0.072μgL^-1 for selenium. The calibration curve shows a satisfactory line inthe concentration range from 0.000 to 1.000μgL^-1 Se. The recovery is 95.8%-102.2%.
文摘0.2000g mogroside sample is digested by 7.0ml nitric acid and 3.0ml hydrogen peroxide, and generated by coprecipitation enrichment hydride - atomic fluorescence spectrometry determines trace selenium in it. Under optimum experiment conditions, a standard curve was produced using selenium standard solution, the linear equation is Ise=2890.6c+0.0012,compared wish the linear relaticnship is not by coprecipitation direct determination of standard series Ise=82.56c+0.0018 Selenium detection sensitivity was increased by 35.01 times,the correlation coefficient of obtained linear regression equation is 0.9996, the detection limit is 0.0012~tg/L and the relative standard deviation is 0.76% (n=5). Containing 0.1808pg.g-1 Se Luo Han Shen samples. Based on mogroside sample, add a certain of standard solution to do recovery experiment, the obtained recovery rate is in 95.8%-103.6% and the result is satisfactory.
文摘In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generation atomic fluorescence spectrometry (HG-AFS) method, and distribution proportions of elements in four phases were calculated. This method was based on the reaction of cadmium with 1.5% (m/v) KBH4 solution and 0.5% KOH(m/v) solution to form the hydride gas in medium of 2% (v/v) HCl. The detection limit for cadmium as low as 0.008μg/L was obtained. The lineally correlation coefficient was 0.99992. The relative standard deviation (n=5, C=1.00μg/L) was 3.26%. The proposed method was applied for the determination of cadmium in atmosphere aerosol samples and the recoveries in the range of 95-102.2% were obtained. This method was simple, rapid, less matrix interference and high sensitivity.
文摘Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was suspended in agar solution by an ultrasound water bath before the HG-AFS determination. The results for the reference material of soil (serial number GBW-07411) agreed satisfactorily with the certified values. Results obtained by the developed procedure compared well with those after traditional acid digestion of samples. The detection limit are 6.7ngL-1 for Hg respectively, with average relative standard deviation values of 6.4% for analysis of a series of soil samples of different origin. The recoveries of the anatytes varied in the range from 95 to 107%. This observation has stimulated interest in fast, accurate and sensitive analytical methods for determination of metals in soil.