期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Determination of Trace Germanium in Marine Sediments by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS) 被引量:2
1
作者 LIJing ZHAOShilan +1 位作者 ZHANGZhaohui ZENGXianjie 《Journal of Ocean University of China》 SCIE CAS 2004年第2期179-182,共4页
A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier g... A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%. 展开更多
关键词 hydride generation-atomic fluorescence spectrometry (HG-AFS) GERMANIUM marine sediment TRACE
下载PDF
Determination of Selenium in Marine Aquatic Products by Hydride Generation-atomic Fluorescence Spectrometry (HG-AFS)
2
作者 ZHANG Zhaohui GAO Xin +1 位作者 Tashiro Yuri Hiroo Ogawa 《Journal of Ocean University of China》 SCIE CAS 2005年第3期252-256,共5页
A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The method is based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure... A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The method is based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure argon, and then swept to Ar-H2 flame quarts atomizer to measure its fluorescence intensity. The hydride generation, transportation, atomization and some instrumental parameters were studied by a kind of orthogonal design. The optimum conditions selected are as follows: reactive acidity, 20% HC1; the amount of NaBH4, 4.9mL; gas flow of argon, 600mLmin^-1; atomizing temperature, 200 ℃ ; negative high voltage, - 300V; light current, 100 mA; integral time, 7s. The detection limit of the presented method is 0.072μgL^-1 for selenium. The calibration curve shows a satisfactory line inthe concentration range from 0.000 to 1.000μgL^-1 Se. The recovery is 95.8%-102.2%. 展开更多
关键词 hydride generation-atomic fluorescence spectrometry(HG-AFS) SELENIUM marine aquatic products
下载PDF
Microwave Digestion Sample Hydride Generation-Atomic Fluorescence Spectrometry Determines Trace Selenium of Mogroside
3
作者 Xiujing Zhang 《International Journal of Technology Management》 2013年第7期128-130,共3页
0.2000g mogroside sample is digested by 7.0ml nitric acid and 3.0ml hydrogen peroxide, and generated by coprecipitation enrichment hydride - atomic fluorescence spectrometry determines trace selenium in it. Under opti... 0.2000g mogroside sample is digested by 7.0ml nitric acid and 3.0ml hydrogen peroxide, and generated by coprecipitation enrichment hydride - atomic fluorescence spectrometry determines trace selenium in it. Under optimum experiment conditions, a standard curve was produced using selenium standard solution, the linear equation is Ise=2890.6c+0.0012,compared wish the linear relaticnship is not by coprecipitation direct determination of standard series Ise=82.56c+0.0018 Selenium detection sensitivity was increased by 35.01 times,the correlation coefficient of obtained linear regression equation is 0.9996, the detection limit is 0.0012~tg/L and the relative standard deviation is 0.76% (n=5). Containing 0.1808pg.g-1 Se Luo Han Shen samples. Based on mogroside sample, add a certain of standard solution to do recovery experiment, the obtained recovery rate is in 95.8%-103.6% and the result is satisfactory. 展开更多
关键词 hydride generation-atomic Fluorescence Spectrometry MOGROSIDE SELENIUM
下载PDF
动物源性食品中痕量无机砷的测定 被引量:12
4
作者 蒋瑾华 温巧玲 胡思 《光谱实验室》 CAS CSCD 2006年第4期751-754,共4页
动物源性食品在6moL/L的盐酸溶液中,经微波萃取后,无机砷以氯化物的形式被提取,氢化物发生-原子荧光光谱法测定痕量无机砷。方法的检出限为:0.25mg/kg(0.5g);回收率为93.5%—103%。本方法适用动物源性食品的质量控制。
关键词 无机砷 动物源性食品 微波萃取 氢化物发生-原子荧光光谱法
下载PDF
压力罐消解-氢化物原子荧光光谱法测定婴儿配方乳粉中硒的方法探讨 被引量:3
5
作者 谭靖怡 王晶 +1 位作者 罗欣阳 梁旭霞 《食品安全质量检测学报》 CAS 2018年第12期2980-2985,共6页
目的探讨压力罐消解-氢化物原子荧光光谱法测定婴儿配方乳粉中硒的测定条件。方法通过压力罐消解和微波消解对比实验、样品重复性实验,用氢化物发生原子荧光光谱(hydride generation atomic fluorescence spectrometry,HG-AFS)和电感耦... 目的探讨压力罐消解-氢化物原子荧光光谱法测定婴儿配方乳粉中硒的测定条件。方法通过压力罐消解和微波消解对比实验、样品重复性实验,用氢化物发生原子荧光光谱(hydride generation atomic fluorescence spectrometry,HG-AFS)和电感耦合等离子体质谱(inductively coupled plasma mass spectrometry,ICP-MS)测定的结果相互比对,确定压力罐消解的可行性以及消解最佳温度;通过测定10μg/L硒溶液和一系列含不同浓度干扰元素的10μg/L硒溶液中硒的荧光强度,计算硒含量的回收率,并与各元素在婴儿配方乳粉中的最高限量对比,讨论HG-AFS法测定时添加铁氰化钾的不必要性。结果采用压力罐消解,消解温度为160℃时,HG-AFS法和ICP-MS法的测定结果无显著差异,精密度分别为1.95%和1.49%;在其他必需矿物质元素含量符合限量要求时,各元素对HG-AFS法测定硒的含量没有干扰。结论压力罐消解法适合于作为HG-AFS法测定婴儿配方乳粉中的硒的前处理方法,该方法操作简单,稳定性好,试剂消耗量少,适合处理大批量样品;HG-AFS法测定婴儿配方乳粉中的硒不必添加铁氰化钾。 展开更多
关键词 婴儿配方乳粉 压力罐消解法 氢化物原子荧光光谱法 铁氰化钾
下载PDF
氢化物原子吸收法与氢化物原子荧光法测定饮用水中砷的方法比较 被引量:5
6
作者 张丽 《广东微量元素科学》 CAS 2013年第8期10-13,共4页
目的建立快速准确测定饮用水中砷的方法。方法用氢化物原子吸收与氢化物原子荧光两种方法检测饮用水中砷含量。结果在选定的最佳仪器条件下,氢化物原子吸收法与氢化物原子荧光法测定饮用水中砷的检出限分别为3.030μg/L和0.027μg/L... 目的建立快速准确测定饮用水中砷的方法。方法用氢化物原子吸收与氢化物原子荧光两种方法检测饮用水中砷含量。结果在选定的最佳仪器条件下,氢化物原子吸收法与氢化物原子荧光法测定饮用水中砷的检出限分别为3.030μg/L和0.027μg/L,RSD分别为0.89%和0.65%,凹收率分别为97.8%~103.4%。结论通过检测方法对比试验发现两种方法检测同一水样结果基本一致,均可达到快速、便捷、准确的目的。 展开更多
关键词 氢化物原子吸收 氢化物原子荧光
下载PDF
Synthesis of a Novel Imidazole Ionic Liquid Modified Mesoporous Silica SBA15 for Selective Separation and Determination of Inorganic Arsenic in Rice
7
作者 CHEN Tuan-Wei ZHEN Wen-Bo +3 位作者 YAN Zhi-Ming LIN He-Tong CHEN Guo-Ying CHEN Shao-Jun 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2018年第12期2024-2035,1848,共13页
A novel 1-methylimidazole ionic liquid modified SBA15 mesoporous silica(1-MIIL@SBA15) was synthesized and applied to selective separation of inorganic arsenic(iAs) in rice by dispersive solid phase extraction(DSPE), f... A novel 1-methylimidazole ionic liquid modified SBA15 mesoporous silica(1-MIIL@SBA15) was synthesized and applied to selective separation of inorganic arsenic(iAs) in rice by dispersive solid phase extraction(DSPE), followed by hydride generation-atomic fluorescence spectrometric(HG-AFS) quantification. The prepared sorbent was characterized by FTIR, FESEM, BET and Zeta potential. Key parameters of adsorption and desorption in DSPE were optimized using standard reference material 1568 b rice flour. Under optimal conditions, the limit of detection was 8.776 ng/kg, relative standard deviation was ≤2.0%, and recoveries of iAs were in the 92.3~94.4% range. This method was successfully applied to the determination of iAs in rice. Under acidic condition, the electrostatic interaction between the positively charged 1-MIIL@SBA15 and anionic iAs played an important role in selective iAs separation, rendering this method suitable for iAs analysis. 展开更多
关键词 SBA15 ionic liquid inorganic arsenic dispersive solid phase extraction hydride generation-atomic fluorescence spectrometric(HG-AFS)
下载PDF
氢化物发生-原子荧光光谱法测定进口未焙烧黄铁矿中总砷含量的不确定度评定 被引量:1
8
作者 吕晓华 《光谱实验室》 CAS 2013年第6期3209-3214,共6页
以氢化物发生-原子荧光光谱法测定进口未焙烧黄铁矿中总砷含量为例,建立了数学模型,对测试过程中的各个分量进行分步计算和合成,计算出扩展不确定度为0.007%,评定结果表明校准曲线是氢化物发生-原子荧光光谱法测定进口未焙烧黄铁矿中总... 以氢化物发生-原子荧光光谱法测定进口未焙烧黄铁矿中总砷含量为例,建立了数学模型,对测试过程中的各个分量进行分步计算和合成,计算出扩展不确定度为0.007%,评定结果表明校准曲线是氢化物发生-原子荧光光谱法测定进口未焙烧黄铁矿中总砷含量不确定度的主要影响因素。 展开更多
关键词 不确定度 总砷 氢化物发生-原子荧光光谱法 未焙烧黄铁矿
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部