期刊文献+
共找到1,151篇文章
< 1 2 58 >
每页显示 20 50 100
Determination of Hg in soil by ultrasonic slurry sampling hydride generation atomic fluorescence spectrometry
1
作者 LIANG Shu-xuan LV Tian-feng ZHOU Wei-jing SUN Han-wen 《Journal of Environmental Science and Engineering》 2008年第5期9-13,共5页
Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was susp... Ultrasonic aided slurry sampling hydride generation atomic fluorescence spectrometry (USS-HG-AFS) was developed for the determination of Hg in soil samples from a sewage-irrigated farm. 500 mg grounded soil was suspended in agar solution by an ultrasound water bath before the HG-AFS determination. The results for the reference material of soil (serial number GBW-07411) agreed satisfactorily with the certified values. Results obtained by the developed procedure compared well with those after traditional acid digestion of samples. The detection limit are 6.7ngL-1 for Hg respectively, with average relative standard deviation values of 6.4% for analysis of a series of soil samples of different origin. The recoveries of the anatytes varied in the range from 95 to 107%. This observation has stimulated interest in fast, accurate and sensitive analytical methods for determination of metals in soil. 展开更多
关键词 hydride generation ultrasonic slurry sampling atomic fluorescence spectrometry SOIL trace element
下载PDF
Determination of Cadmium in TSP, PM10 in urban areas by hydride generation atomic fluorescence spectrometry
2
作者 LIANG Shu-xuan LI Ling ZHOU Wei-jing LV Tian-feng SUN Han-wen 《Journal of Environmental Science and Engineering》 2007年第1期39-43,54,共6页
In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generat... In this paper, two different diameter particles (TSP, PM10) were collected by TH-16A four-channels classification air sampler. The samples were treated by HNO3. Analysis of cadmium was carried out by hydride generation atomic fluorescence spectrometry (HG-AFS) method, and distribution proportions of elements in four phases were calculated. This method was based on the reaction of cadmium with 1.5% (m/v) KBH4 solution and 0.5% KOH(m/v) solution to form the hydride gas in medium of 2% (v/v) HCl. The detection limit for cadmium as low as 0.008μg/L was obtained. The lineally correlation coefficient was 0.99992. The relative standard deviation (n=5, C=1.00μg/L) was 3.26%. The proposed method was applied for the determination of cadmium in atmosphere aerosol samples and the recoveries in the range of 95-102.2% were obtained. This method was simple, rapid, less matrix interference and high sensitivity. 展开更多
关键词 hydride generation atomic fluorescence spectrometry atmosphere aerosol CADMIUM
下载PDF
Determination of total arsenic by photo-decomposition of organoarsenic compounds and hydride generation electrothermal atomic absorption spectrometry 被引量:4
3
作者 Han Hengbin, Liu Yanbing, Zhang Shuzhen Ni ZhemingResearch Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing 100085, China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1993年第1期99-107,共9页
A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a p... A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a palladium coated graphite tube with subsequent atomization and detection by AAS. The organoarsenicals include monomethylarsenic, dimethylarsenic, arsenobetaine, arsenocholine, o -aminobenzenarsenate and p -aminobenzenarsenate. The method is simple and sensitive. Detection limit was obtained from different arsenic compounds over the range from 0. 058 to 0.063 ng/ml as As (based on three times of the standard deviation of 10 blank measurements) and the relative standard deviations for ten replicate measurements were from 2.0 to 3.8%. The calibration curves of arsenic compounds including inorganic and organic arsenicals were linear over the range from 0.1 to 3.0 ng/ml as As. The recommended method has been applied to the determination of total arsenic in tap and lake water samples at ng/ml levels. 展开更多
关键词 electrothermal atomic absorption spectrometry photo -decomposition organoarsenic compounds arsenic hydride generation tap/lake water
下载PDF
Effect of sample treatment on determination of arsenic (Ⅲ) and arsenic (Ⅴ) in aqueous and tissue samples by hydride generation atomic absorption spectrometry 被引量:1
4
作者 Jamileh Salar-Amoli Tahereh Ali-Esfahani Jalal Hassan 《Journal of Chemistry and Chemical Engineering》 2009年第6期49-53,共5页
The purpose of this procedure was to optimize and improve a method that used for the determination of arsenic (Ⅲ) and arsenic (Ⅴ) in biological and environmental samples. The method is based on hydride generatio... The purpose of this procedure was to optimize and improve a method that used for the determination of arsenic (Ⅲ) and arsenic (Ⅴ) in biological and environmental samples. The method is based on hydride generation and atomic absorption spectrometry. For both As (Ⅲ) and As (Ⅴ) the parameters such as NaBH4, HCI concentration, and pH were optimized. Absorption signal of As (Ⅴ) was approximately 17% of As (Ⅲ) signal. Therefore, for estimation of As (Ⅲ) and As (Ⅴ) concentrations in various samples the difference between the absorbance obtained for arsenic, without and with previous treatment of samples with potassium iodide (KI), can be applied. The calibration graphs were linear (r〉0.99), and the detection limits of the method based on three times the standard deviation of the blank were 0.14 and 0.64 μL^-1 for As (Ⅲ) and As (Ⅴ), respectively. The relative standard deviation (R.S.D.) of measurements was less than 10%. As a means of checking performance method, water samples were spiked with known concentrations of both As (Ⅲ) and As (Ⅴ), and recovery above 94% was obtained. The proposed method was applied successfully to determine inorganic As (Ⅲ) and As (Ⅴ) in various environmental and total As in biological samples. 展开更多
关键词 arsenic speciation hydride generation atomic absorption spectrometry
下载PDF
DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION
5
作者 Shu Kun XU and Zhao Lun FANG Institute of Applied Ecology, Academia Sinica, Shenyang, 110015 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第11期915-918,共4页
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(... On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%. 展开更多
关键词 Zhang DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION hydride generation atomic ABSORPTION spectrometry WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION SQ CPG ION LINE
下载PDF
Determination of Inorganic Arsenic Species by Electrochemical Hydride Generation Atomic Absorption Spectrometry with Selective Electrochemical Reduction 被引量:1
6
作者 李勋 汪正浩 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2007年第3期295-299,共5页
A new direct procedure for the determination of inorganic arsenic species was developed by electrochemical hydride generation atomic absorption spectrometry (EcHG-AAS) with selective electrochemical reduction. The d... A new direct procedure for the determination of inorganic arsenic species was developed by electrochemical hydride generation atomic absorption spectrometry (EcHG-AAS) with selective electrochemical reduction. The determination of inorganic arsenic species is based on the fact that As(Ⅲ) shows significantly higher absorbance at low electrolytic currents than As(Ⅴ) in 0.3 mol·L^-1 H2SO4. The electrolytic current used for the determination of As(Ⅲ) without considerable interferences of As(Ⅴ) was 0.4 A, whereas the current for the determination of As(Ⅲ) and As(Ⅴ) was 1.2 A. For equal concentrations of As(Ⅲ) and As(Ⅴ) in a sample, the interferences of As(Ⅴ) during the As(Ⅲ) determination were smaller than 5%. The absorbance for As(Ⅴ) could be calculated by subtracting that for As(Ⅲ) measured at 0.4 A from the total absorbance for As(Ⅲ) and As(Ⅴ) measured at 1.2 A, and then the concentration of As(Ⅴ) can be obtained by its calibration curve at 1.2 A. The methodology developed provided the detection limits of 0.3 and 0.6 ng·mL^-1 for As(Ⅲ) and As(Ⅴ), respectively. The relative standard deviations were of 3.5% for 20 ng·mL^-1 As(Ⅲ) and 3.2% for 20 ng·mL^-1 As(Ⅴ). The method was successfully applied to determination of soluble inorganic arsenic species in Chinese medicine. 展开更多
关键词 electrochemical hydride generation atomic absorption spectrometry inorganic arsenic species
原文传递
高效液相色谱-氢化物发生-原子荧光光谱法测定富硒大豆中硒代氨基酸的含量 被引量:1
7
作者 卢鑫 张琳 +1 位作者 王铁良 周晓华 《理化检验(化学分册)》 CAS CSCD 北大核心 2024年第3期288-293,共6页
取0.1 g脱脂后富硒大豆样品于离心管中,用5 mL pH 7.5的130 mmol·L^(-1)三(羟甲基)氨基甲烷-盐酸缓冲液超声振荡30 min,用15 mg链霉蛋白酶于37℃振荡酶解5 h,离心后取上清液,过0.22μm尼龙有机滤膜。滤液中的硒代半胱氨酸(SeCys)... 取0.1 g脱脂后富硒大豆样品于离心管中,用5 mL pH 7.5的130 mmol·L^(-1)三(羟甲基)氨基甲烷-盐酸缓冲液超声振荡30 min,用15 mg链霉蛋白酶于37℃振荡酶解5 h,离心后取上清液,过0.22μm尼龙有机滤膜。滤液中的硒代半胱氨酸(SeCys)、硒代蛋氨酸(SeMet)、甲基硒代半胱氨酸(MeSeCys)在Agela MP-C_(18)色谱柱上分离,以含2%(体积分数)甲醇和0.5 mmol·L^(-1)四丁基溴化铵的40 mmol·L^(-1)磷酸氢二铵溶液(pH 7.0)进行等度洗脱,并采用氢化物发生-原子荧光光谱法测定3种硒代氨基酸的含量。结果表明,3种硒代氨基酸在7 min内可以实现基线分离,标准曲线的线性范围均为5~100μg·L^(-1),检出限依次为0.086,0.075,0.047 mg·kg^(-1)。按照标准加入法进行回收试验,回收率为85.5%~103%,测定值的相对标准偏差(n=7)不大于3.0%。方法用于分析富硒大豆中的硒代氨基酸,大豆中硒赋存形态多为SeMet,含量占总硒量的85.5%~94.5%。 展开更多
关键词 高效液相色谱-氢化物发生-原子荧光光谱法(HPLC-HG-AFS) 大豆 硒代氨基酸 硒形态
下载PDF
氢化物发生-非色散原子荧光光谱法测定粉饼化妆品中Pb,As和Hg含量
8
作者 刘萍 程磊 《日用化学工业(中英文)》 CAS 北大核心 2024年第9期1140-1144,共5页
建立并优化了氢化物发生-非色散原子荧光光谱法(HG-NDAFS)测定10种粉饼化妆品中铅(Pb),砷(As)和汞(Hg)的含量。确定了较佳载气流速为400 mL/min,屏蔽气流速为800 mL/min。优化了负高压和灯电流,确定了原子化器高度为8 mm。优化还原剂体... 建立并优化了氢化物发生-非色散原子荧光光谱法(HG-NDAFS)测定10种粉饼化妆品中铅(Pb),砷(As)和汞(Hg)的含量。确定了较佳载气流速为400 mL/min,屏蔽气流速为800 mL/min。优化了负高压和灯电流,确定了原子化器高度为8 mm。优化还原剂体系时,选择了质量分数1.5%KBH4溶液。载流选择2.4 mol/L HCl。结果显示,Pb,As,Hg的加标回收率分别为83.44%~90.32%,83.22%~86.59%,81.43%~89.94%,加标回收率良好。10种粉饼中共检出2种粉饼中含有Pb(含量0.48和0.27 mg/kg),1种粉饼中含有As(含量0.62 mg/kg),1种粉饼中含有Hg(含量0.11 mg/kg)。10种粉饼中的Pb,As,Hg含量均未超标。本研究建立的HG-NDAFS测定粉饼化妆品中Pb,As和Hg含量的方法准确度高,可用于粉饼化妆品中Pb,As和Hg含量的检测。 展开更多
关键词 氢化物发生-非色散原子荧光光谱法 粉饼 化妆品 铅元素 砷元素 汞元素
下载PDF
氢化物发生-原子荧光光谱法(HG-AFS)测达里诺尔湖流域底泥样硒
9
作者 薛舒文 苏丹 +2 位作者 张嘉璇 张营 徐苏男 《科技创新与应用》 2024年第15期83-86,共4页
氢化物发生-原子荧光光谱法(HG-AFS)是测定硒(Selenium,Se)的理想方法,能精确测定水样和含水地球化学样品(底泥)中Se的含量。由于达里湖底泥中Se含量相对较低,有机质的还原状态较高,在测量Se含量时往往因为过于复杂且低于仪器检出限而... 氢化物发生-原子荧光光谱法(HG-AFS)是测定硒(Selenium,Se)的理想方法,能精确测定水样和含水地球化学样品(底泥)中Se的含量。由于达里湖底泥中Se含量相对较低,有机质的还原状态较高,在测量Se含量时往往因为过于复杂且低于仪器检出限而不能被检测到有效值。该文应用HG-AFS测定达里诺尔湖底泥中Se的含量,使用微波消解石墨赶酸作为前处理方法,并使用HG-AFS进行Se含量的测试,采用此法测定底泥中Se元素具有快速、准确、重现性好,被确定为一种快速可靠的对底泥样品Se含量进行测定的方法。 展开更多
关键词 湖泊底泥 氢化物发生-原子荧光光谱法 微波消解 测定
下载PDF
锗元素测定方法综述
10
作者 冯均利 张庆新 +5 位作者 钟坚海 张磊 黎良伟 杨文超 何宏平 余淑媛 《中国无机分析化学》 CAS 北大核心 2024年第7期923-930,共8页
锗在国防工业、航空航天和通信等领域中具有战略性意义,锗含量的测定对于保证材料质量和满足国际标准至关重要。对锗含量测定方法的多种技术进行了综述,包括分光光度法、原子荧光光谱法、原子吸收光谱法、电感耦合等离子体原子发射光谱... 锗在国防工业、航空航天和通信等领域中具有战略性意义,锗含量的测定对于保证材料质量和满足国际标准至关重要。对锗含量测定方法的多种技术进行了综述,包括分光光度法、原子荧光光谱法、原子吸收光谱法、电感耦合等离子体原子发射光谱法、电感耦合等离子体质谱法以及滴定法等。在每种检测方法的介绍中,详细探讨了方法的原理、前处理步骤以及应用范围,并分别总结了各方法的优势和不足。最后,强调了锗含量测定方法的意义,特别是在满足出口监管和促进科学研究方面的作用。同时对锗元素的测定方法进行了展望,为未来的发展提供了参考方向。 展开更多
关键词 测定方法 分光光度法 原子荧光光谱法 电感耦合等离子体原子发射光谱法 滴定法
下载PDF
高盐食品基质中砷含量的测定 被引量:3
11
作者 戴瑞平 刘花梅 +6 位作者 舒露 唐丽君 黎申英 李彪 张梅玲 刘涛 黄宗兰 《现代食品科技》 CAS 北大核心 2024年第4期321-330,共10页
建立了一种基体匹配-动态反应池-电感耦合等离子体质谱法测定高盐食品基质中砷含量的方法,以解决高盐基体对砷测定的质谱干扰和基体干扰。研究电感耦合等离子体质谱法与氢化物发生原子荧光光谱法测定食品中总砷的技术要点,通过分析前处... 建立了一种基体匹配-动态反应池-电感耦合等离子体质谱法测定高盐食品基质中砷含量的方法,以解决高盐基体对砷测定的质谱干扰和基体干扰。研究电感耦合等离子体质谱法与氢化物发生原子荧光光谱法测定食品中总砷的技术要点,通过分析前处理消解方式、有机基质、氯含量和内标校正元素等对砷含量测定的影响,建立了高盐食品基质中砷含量的测定方法。实验结果表明,微波消解法并不太适用于氢化物发生原子荧光光谱法测定食品中总砷,有机基质和氯分别会对砷的质谱测定信号产生增敏效应和质谱干扰,74Ge比72Ge更适合作为电感耦合等离子体质谱法测定食品中总砷的内标元素。建立的检测方法定量限0.010 mg/kg,高盐基体中砷在0.010、0.025、0.20、0.50 mg/kg添加水平的回收率为91.50%~110.80%,相对标准偏差范围为0.76%~7.22%。本法和参照法对样品分析结果统计值均大于t0.90,10(1.81,双边),测定结果存在显著性差异,对实际样品测定结果表明动能歧视测定模式并不太适用于高盐食品基质样品中总砷的测定。该方法准确可靠,能用于高盐和高基体食品中砷含量的测定分析。 展开更多
关键词 高盐食品基质 氢化物发生原子荧光光谱法 电感耦合等离子体质谱法 基体匹配
下载PDF
微波消解-氢化物原子荧光光谱法测定胡萝卜硒含量
12
作者 张美琦 苏丹 +2 位作者 张嘉璇 张珍岩 铁梅 《科技创新与应用》 2024年第32期71-74,共4页
硒是人体内各种含硒酶及含硒蛋白的合成过程中必不可少的一种微量元素,能提高身体的免疫功能。硒对人体有一定的防癌作用,硒不但对肿瘤有抑制作用而且还能影响致癌物质的新陈代谢,素有“防癌之王”之称。采用人工栽培方式生产的富硒胡... 硒是人体内各种含硒酶及含硒蛋白的合成过程中必不可少的一种微量元素,能提高身体的免疫功能。硒对人体有一定的防癌作用,硒不但对肿瘤有抑制作用而且还能影响致癌物质的新陈代谢,素有“防癌之王”之称。采用人工栽培方式生产的富硒胡萝卜是一种较为理想的富硒型蔬菜。该文以胡萝卜为研究对象,利用微波消解-氢化物原子荧光光谱法测定胡萝卜中总硒的含量,探讨不同微波消解溶剂和消解条件对含硒胡萝卜消解效果的影响,并优化氢化物原子荧光光谱法测定条件。结果表明,最佳消解体系为HNO_(3)-H_(2)O_(2)体系(5 mL∶2 mL);最佳微波消解条件为,第一工步为2 min、0.2 MPa;第二工步为6 min、0.5 MPa和6 min、0.7 MPa;第三工步为5 min、1 MPa;在最优条件下,测硒的线性范围为0~50μg/L。对样品空白荧光值进行10次测定,RSD=2.24%,最低检出限为0.90μg/kg。土壤中施硒能够显著提高胡萝卜中总硒的含量,较空白对照组提高6.50%(地上)和10.30%(地下),可食用(地下)部位的最高硒含量为445.90μg/kg。 展开更多
关键词 微波消解 氢化物原子荧光光谱法 富硒 胡萝卜 含量
下载PDF
吡咯烷二硫代氨基甲酸铵螯合-浊点萃取-氢化物发生原子荧光光谱法测定饮用水中痕量汞
13
作者 刘景龙 韩倩 杨超 《理化检验(化学分册)》 CAS CSCD 北大核心 2024年第6期570-575,共6页
鉴于标准HJ 694—2014检测饮用水中汞的检出限较高,无法满足痕量汞的分析要求,提出以吡咯烷二硫代氨基甲酸铵(APDC)溶液为螯合剂,以非离子型表面活性剂Triton X-114溶液为萃取剂,通过浊点萃取的方式将饮用水中的痕量汞富集于表面活性剂... 鉴于标准HJ 694—2014检测饮用水中汞的检出限较高,无法满足痕量汞的分析要求,提出以吡咯烷二硫代氨基甲酸铵(APDC)溶液为螯合剂,以非离子型表面活性剂Triton X-114溶液为萃取剂,通过浊点萃取的方式将饮用水中的痕量汞富集于表面活性剂相,采用氢化物发生原子荧光光谱法测定痕量汞的方法。水样经过滤、酸化后,分取50 mL水样,加入2.0 g·L^(−1)APDC溶液1.5 mL,5%(体积分数)Triton X-114溶液1.5 mL,调节混合溶液酸度至pH 6,于40℃平衡5 min,以2900 r·min^(−1)转速离心10 min,冰水浴中冷却5~10 min。弃去上层水相,在表面活性剂相中加入由磷酸三丁酯与乙醇按体积比1∶1混合配制的消泡剂300μL,用5%(体积分数)盐酸溶液稀释至5 mL,上机检测。结果显示:汞的质量浓度在2.0μg·L^(−1)以内和对应的荧光强度呈线性关系,检出限为0.002μg·L^(−1)。按标准加入法进行回收试验,回收率为86.8%~97.9%,测定值的相对标准偏差(n=6)不大于8.0%。方法检出限较标准HJ 694—2014低一个数量级,能够满足饮用水等清洁水样中痕量汞分析的检出限要求。 展开更多
关键词 浊点萃取 螯合剂 氢化物发生原子荧光光谱法 预富集
下载PDF
稀酸微波消解-氢化物发生原子荧光光谱法测定蔬菜中总汞
14
作者 张晓荣 傅志丰 《中国无机分析化学》 CAS 北大核心 2024年第11期1485-1491,共7页
为践行食品检测工作“环保”的理念,以菠菜粉质控样品为研究对象,通过考察硝酸浓度、微波消解温度、赶酸条件以及其他检测条件对总汞测定的影响,建立稀酸微波消解-氢化物发生原子荧光光谱法测定蔬菜中总汞的方法,并对方法进行评价,对九... 为践行食品检测工作“环保”的理念,以菠菜粉质控样品为研究对象,通过考察硝酸浓度、微波消解温度、赶酸条件以及其他检测条件对总汞测定的影响,建立稀酸微波消解-氢化物发生原子荧光光谱法测定蔬菜中总汞的方法,并对方法进行评价,对九江市售蔬菜中汞含量进行测定。结果表明,最佳消解液组成为5 mL硝酸(20%)+1.0 mL过氧化氢、微波消解最高温度为160℃、载流为HNO_(3)(5%)、负高压280 V、KBH_(4)浓度0.5%。新建立的方法检出限为0.000 1 mg/kg,汞在0~2.0μg/L线性关系良好,加标回收率为92.0%~106%,相对标准偏差RSD为2.5%~5.5%。方法操作简便,大幅度减少了前处理过程硝酸使用量,无需赶酸,精密度、重现性好,灵敏度、准确度高,推广应用前景广阔。 展开更多
关键词 稀酸微波消解 蔬菜 总汞 氢化物发生原子荧光光谱法
下载PDF
离心管石墨消解-原子荧光光谱法测定土壤中总砷和总汞
15
作者 袁野 何丹风 易姗姗 《化学分析计量》 CAS 2024年第8期74-78,共5页
对现有国标方法(GB/T 22105.1—2008《土壤质量总汞、总砷、总铅的测定原子荧光法第1部分:土壤中总汞的测定》和GB/T 22105.2—2008《土壤质量总汞、总砷、总铅的测定原子荧光法第2部分:土壤中总砷的测定》)测量土壤中总砷和总汞的方法... 对现有国标方法(GB/T 22105.1—2008《土壤质量总汞、总砷、总铅的测定原子荧光法第1部分:土壤中总汞的测定》和GB/T 22105.2—2008《土壤质量总汞、总砷、总铅的测定原子荧光法第2部分:土壤中总砷的测定》)测量土壤中总砷和总汞的方法进行改进,建立离心管石墨消解-原子荧光光谱法测定土壤中总砷和总汞含量。称取国家一级土壤标准物质GBW 07428、GBW 07408样品于离心管中,采用王水消解,测定土壤中总砷和总汞含量。砷和汞的质量浓度在一定范围内与荧光强度具有良好的线性关系,线性相关系数均大于0.999,检出限分别为0.057、0.0043 mg/kg。测定结果的相对标准偏差为2.48%~3.82%(n=8),砷、汞的加标回收率分别为94.0%~101.4%、98.6%~103.5%。该方法检出限、精密度、准确度均能满足土壤检测的要求,样品无需过滤或放置澄清,能更好地满足日渐增加的土壤分析工作。 展开更多
关键词 土壤 王水 方法改进 原子荧光光谱法 总砷 总汞
下载PDF
微波消解-氢化物原子荧光光谱法检测食品中的砷
16
作者 刘冬青 《山东化工》 CAS 2024年第19期166-168,172,共4页
采用微波消解法进行前处理,氢化物原子荧光光谱法检测食品中的砷元素。该方法与湿法消解相比,操作简单、耗时短且样品消解更彻底。通过优化仪器参数,本方法相关系数为0.99923;在检出限、定量限水平做样品加标,回收率范围分别为81.2%~92.... 采用微波消解法进行前处理,氢化物原子荧光光谱法检测食品中的砷元素。该方法与湿法消解相比,操作简单、耗时短且样品消解更彻底。通过优化仪器参数,本方法相关系数为0.99923;在检出限、定量限水平做样品加标,回收率范围分别为81.2%~92.6%,80.5%~99.8%;相对误差、变异系数范围分别为0.0964%~2.19%,0.348%~2.49%;在定量限、2倍定量限和3倍定量限水平加标的回收率在84.2%~99.6%。通过验证,各项均满足要求,该方法适用于食品中砷的检测。 展开更多
关键词 微波消解法 氢化物原子荧光光谱法 食品
下载PDF
使用控制图法对原子荧光法测定土壤中砷进行不确定度评定
17
作者 胡家君 冉伟 姜佳伟 《科技资讯》 2024年第1期166-170,共5页
根据《检测实验室中常用不确定度评定方法与表示》(GB/T 27411-2012)中控制图法,在期间精密度测量条件下按照《土壤和沉积物汞、砷、硒、铋、锑的测定微波消解/原子荧光法》(HJ 680-2013)对土壤中砷进行重复测量,得到34组测量数据。首... 根据《检测实验室中常用不确定度评定方法与表示》(GB/T 27411-2012)中控制图法,在期间精密度测量条件下按照《土壤和沉积物汞、砷、硒、铋、锑的测定微波消解/原子荧光法》(HJ 680-2013)对土壤中砷进行重复测量,得到34组测量数据。首先计算其正态统计量(A^(2*)),并判断数据的正态性、独立性和分辨力适宜性;其次再绘制控制图,使用失控准则判断测量系统处于受控状态;最后使用t检验判断数据统计上的偏倚受控。三者均满足的情况下,可视期间精密度标准偏差为实验室土壤中砷的测量不确定度。 展开更多
关键词 不确定度评定 控制图法 土壤中砷 原子荧光法 环境检测
下载PDF
微波消解-原子荧光光谱法测定栀子中硒含量
18
作者 陈思 王姣 《食品安全导刊》 2024年第7期93-95,99,共4页
本文采用微波消解-原子荧光光谱法测定栀子中的硒元素含量。结果表明,使用8 mL硝酸和2 mL过氧化氢时,能够将0.300 0 g的栀子样品完全消解,并且荧光强度良好。方法在0~10μg·L^(-1)具有良好的线性关系,检出限为0.050 5 ng·mL^(... 本文采用微波消解-原子荧光光谱法测定栀子中的硒元素含量。结果表明,使用8 mL硝酸和2 mL过氧化氢时,能够将0.300 0 g的栀子样品完全消解,并且荧光强度良好。方法在0~10μg·L^(-1)具有良好的线性关系,检出限为0.050 5 ng·mL^(-1),精密度为3.0%,加标回收率在96.80%~100.34%。该方法具有较高的准确性和灵敏度。 展开更多
关键词 微波消解法 原子荧光光谱法
下载PDF
氢化物发生-原子荧光光谱法测定煤中锗含量的研究
19
作者 陈慧珠 《煤炭加工与综合利用》 CAS 2024年第7期104-109,共6页
研究了HG-AFS法测定煤中微量锗含量的方法。通过对原子荧光光谱仪工作条件、氢化物发生条件和样品处理的研究,初步建立了氢化物发生—原子荧光光谱法测定煤中锗含量的方法。结果表明,该方法检出限为0.18μg/L,精密度在1.97%~5.27%,加标... 研究了HG-AFS法测定煤中微量锗含量的方法。通过对原子荧光光谱仪工作条件、氢化物发生条件和样品处理的研究,初步建立了氢化物发生—原子荧光光谱法测定煤中锗含量的方法。结果表明,该方法检出限为0.18μg/L,精密度在1.97%~5.27%,加标回收率为97%~105%。说明氢化物发生—原子荧光光谱法适用于煤中锗含量的测定,且准确度和稳定性高;研究成果可为《煤中锗含量的测定》国家标准修订提供科学基础。 展开更多
关键词 原子荧光光谱法 仪器工作条件 前处理方式
下载PDF
原子荧光法和电感耦合等离子体质谱法测定地表水中砷硒锑方法比对研究
20
作者 李志林 杨春涛 +2 位作者 普学伟 赵海茜 鲁瑞梅 《广州化工》 CAS 2024年第12期95-97,共3页
建立了原子荧光光谱法与电感耦合等离子体质谱法测定地表水中砷、硒、锑的方法。在优化了的仪器和实验条件下,比较了两者的线性关系、检出限、准确度、精密度。结果表明,两种方法相关系数0.9991~0.9999,检出限为0.23~0.59μg/L,样品加... 建立了原子荧光光谱法与电感耦合等离子体质谱法测定地表水中砷、硒、锑的方法。在优化了的仪器和实验条件下,比较了两者的线性关系、检出限、准确度、精密度。结果表明,两种方法相关系数0.9991~0.9999,检出限为0.23~0.59μg/L,样品加标回收率为92.4%~107%,RSD为0.9%~6.9%,利用国家标准物质验证两种方法的可靠性与准确,测定值均在标准值允许范围内,两种方法准确度高、精密度好、灵敏度高,两种方都可以有效监测地表水中的砷、硒、锑。 展开更多
关键词 原子荧光法 电感耦合等离子体质谱法 砷、硒、锑 方法比对
下载PDF
上一页 1 2 58 下一页 到第
使用帮助 返回顶部