This paper analyses the changing rule of indoor ozone concentration and its influencing factors.A formula of indoor-outdoor concentration ratio(I/O ratio) was deduced based on the indoor ozone mass-balance equation.Th...This paper analyses the changing rule of indoor ozone concentration and its influencing factors.A formula of indoor-outdoor concentration ratio(I/O ratio) was deduced based on the indoor ozone mass-balance equation.The ozone I/O ratio in different kinds of buildings was studied.Results show that I/O ratio is much related to air-exchange rate,which is well compatible with the theoretical calculation results.展开更多
In many communities, residential wood burning is the source of a significant fraction of wintertime PM2.5 and produces exposures to nearby residents inside their homes. To evaluate the magnitude of this effect, black ...In many communities, residential wood burning is the source of a significant fraction of wintertime PM2.5 and produces exposures to nearby residents inside their homes. To evaluate the magnitude of this effect, black carbon particles were measured as a proxy for woodsmoke indoors and outdoors in a community where residential woodsmoke is the only significant particle source. Thirteen indoor/outdoor measurement pairs were obtained at 4 different residences and showed an average indoor/outdoor concentration ratio of 0.78 ± 0.21 for residences without indoor generation. In addition, a time dependent mass balance model was used in conjunction with aethalometer measurements taken over 16 nights at a single residence to estimate an average air exchange rate of 0.26 ± 0.08 h-1, an average deposition loss rate of 0.08 ± 0.03 h-1, and an average penetration factor of 0.97 ± 0.02. Using a mechanistic approach which utilizes these average values in a steady state model, the predicted average infiltration factor was 0.74 for the residence studied. The high values for both measured I/O ratio and modeled infiltration factor show that residential environments provide inhabitants with relatively little protection from recently generated wood smoke particles.展开更多
The time series of indoor and outdoor particle number concentrations in a naturally ventilated residential building in Xi'an were tested simultaneously for 7 days in summer. The relationships between indoor and outdo...The time series of indoor and outdoor particle number concentrations in a naturally ventilated residential building in Xi'an were tested simultaneously for 7 days in summer. The relationships between indoor and outdoor concentrations were examined and discussed, and linear regression analysis was employed to correlate the indoor and outdoor concentrations. The diurnal cycles of indoor and outdoor particle concentrations of different particle size ranges all showed positive correlations between indoor and outdoor number concentrations, The I/O ratios of number concentrations varied with the increase of particle size in the range of 0.89 (±0.19) to 0.99 (±0.15).展开更多
文摘This paper analyses the changing rule of indoor ozone concentration and its influencing factors.A formula of indoor-outdoor concentration ratio(I/O ratio) was deduced based on the indoor ozone mass-balance equation.The ozone I/O ratio in different kinds of buildings was studied.Results show that I/O ratio is much related to air-exchange rate,which is well compatible with the theoretical calculation results.
文摘In many communities, residential wood burning is the source of a significant fraction of wintertime PM2.5 and produces exposures to nearby residents inside their homes. To evaluate the magnitude of this effect, black carbon particles were measured as a proxy for woodsmoke indoors and outdoors in a community where residential woodsmoke is the only significant particle source. Thirteen indoor/outdoor measurement pairs were obtained at 4 different residences and showed an average indoor/outdoor concentration ratio of 0.78 ± 0.21 for residences without indoor generation. In addition, a time dependent mass balance model was used in conjunction with aethalometer measurements taken over 16 nights at a single residence to estimate an average air exchange rate of 0.26 ± 0.08 h-1, an average deposition loss rate of 0.08 ± 0.03 h-1, and an average penetration factor of 0.97 ± 0.02. Using a mechanistic approach which utilizes these average values in a steady state model, the predicted average infiltration factor was 0.74 for the residence studied. The high values for both measured I/O ratio and modeled infiltration factor show that residential environments provide inhabitants with relatively little protection from recently generated wood smoke particles.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 50578034, Grant No. 40475047)Shanghai Educational Development Foundation Titled "Shuguang Project", P.R. China (Grant No. 03SG30).
文摘The time series of indoor and outdoor particle number concentrations in a naturally ventilated residential building in Xi'an were tested simultaneously for 7 days in summer. The relationships between indoor and outdoor concentrations were examined and discussed, and linear regression analysis was employed to correlate the indoor and outdoor concentrations. The diurnal cycles of indoor and outdoor particle concentrations of different particle size ranges all showed positive correlations between indoor and outdoor number concentrations, The I/O ratios of number concentrations varied with the increase of particle size in the range of 0.89 (±0.19) to 0.99 (±0.15).