Knowledge-based engineering(KBE) has made success in automobile and molding design industry, and it is introduced into the ship structural design in this paper. From the implementation of KBE, the deterministic design...Knowledge-based engineering(KBE) has made success in automobile and molding design industry, and it is introduced into the ship structural design in this paper. From the implementation of KBE, the deterministic design solutions for both rules design method(RDM) and interpolation design method(IDM) are generated. The corresponding finite element model is generated. Gaussian process(GP) is then employed to build the surrogate model for finite element analysis, in order to increase efficiency and maintain accuracy at the same time, and the multi-modal adaptive importance sampling method is adopted to calculate the corresponding structural reliability.An example is given to validate the proposed method. Finally, the reliabilities of the structures' strength caused by uncertainty lying in water corrosion, static and wave moments are calculated, and the ship structures are optimized to resist the water corrosion by multi-island genetic algorithm. Deterministic design results from the RDM and IDM are compared with each separate robust design result. The proposed method shows great efficiency and accuracy.展开更多
Islanding refers to a condition where distributed generators(DGs)inject power solely to the local load after electrical separation from power grid.Several islanding detection methods(IDMs)categorized into remote,activ...Islanding refers to a condition where distributed generators(DGs)inject power solely to the local load after electrical separation from power grid.Several islanding detection methods(IDMs)categorized into remote,active,and passive groups have been reported to detect this undesirable state.In active techniques,a disturbance is injected into the DG’s controller to drift a local yardstick out of the permissible range.Although this disturbance leads to more effective detections even in well-balanced island,it raises the total harmonic distortion(THD)of the output current under the normal operation conditions.This paper analyzes the power quality aspect of the modified sliding mode controller as a new active IDM for grid-connected photovoltaic system(GCPVS)with a string inverter.Its performance is compared with the voltage positive feedback(VPF)method,a well-known active IDM.This evaluation is carried out for a 1 k Wp GCPVS in MATLAB/Simulink platform by measuring the output current harmonics and THD as well as the efficiency under various penetration and disturbance levels.The output results demonstrate that since the proposed disturbance changes the amplitude of the output current,it does not generate harmonics/subharmonics.Thereby,it has a negligible adverse effect on power quality.It is finally concluded that the performance of the sliding mode-based IDM is reliable from the standpoints of islanding detection and power quality.展开更多
基金the Project of Ministry of Finance andMinistry of Education of China(Nos.200512 and201335)the State Key Laboratory of Ocean Engineering Foundation of Shanghai Jiao Tong University(No.GKZD010053-10)
文摘Knowledge-based engineering(KBE) has made success in automobile and molding design industry, and it is introduced into the ship structural design in this paper. From the implementation of KBE, the deterministic design solutions for both rules design method(RDM) and interpolation design method(IDM) are generated. The corresponding finite element model is generated. Gaussian process(GP) is then employed to build the surrogate model for finite element analysis, in order to increase efficiency and maintain accuracy at the same time, and the multi-modal adaptive importance sampling method is adopted to calculate the corresponding structural reliability.An example is given to validate the proposed method. Finally, the reliabilities of the structures' strength caused by uncertainty lying in water corrosion, static and wave moments are calculated, and the ship structures are optimized to resist the water corrosion by multi-island genetic algorithm. Deterministic design results from the RDM and IDM are compared with each separate robust design result. The proposed method shows great efficiency and accuracy.
文摘Islanding refers to a condition where distributed generators(DGs)inject power solely to the local load after electrical separation from power grid.Several islanding detection methods(IDMs)categorized into remote,active,and passive groups have been reported to detect this undesirable state.In active techniques,a disturbance is injected into the DG’s controller to drift a local yardstick out of the permissible range.Although this disturbance leads to more effective detections even in well-balanced island,it raises the total harmonic distortion(THD)of the output current under the normal operation conditions.This paper analyzes the power quality aspect of the modified sliding mode controller as a new active IDM for grid-connected photovoltaic system(GCPVS)with a string inverter.Its performance is compared with the voltage positive feedback(VPF)method,a well-known active IDM.This evaluation is carried out for a 1 k Wp GCPVS in MATLAB/Simulink platform by measuring the output current harmonics and THD as well as the efficiency under various penetration and disturbance levels.The output results demonstrate that since the proposed disturbance changes the amplitude of the output current,it does not generate harmonics/subharmonics.Thereby,it has a negligible adverse effect on power quality.It is finally concluded that the performance of the sliding mode-based IDM is reliable from the standpoints of islanding detection and power quality.