In order to meet the requirements of information exchange varieties and manners in wide area protection system, a communication service model based on IEC 61850 is proposed. This service model can realize communicatio...In order to meet the requirements of information exchange varieties and manners in wide area protection system, a communication service model based on IEC 61850 is proposed. This service model can realize communication consistency and cooperation between different types of devices. Furthermore, the communication reliability and time delay performance are guaranteed to meet the requirements of relay protection from the upper layer. Message structure of generic sub-station event (GSE) and its communication mechanism are discussed. General methods to communicate digital information by generic substation status event (GSSE) and communicate analog sampling information by sampling analog value (SAV) of GSE are proposed.展开更多
Globally, traditional power systems are rapidly transforming towards the adoption of smart grid platforms. Substations which are at the center of the electric power transformation from the power plant are changing to ...Globally, traditional power systems are rapidly transforming towards the adoption of smart grid platforms. Substations which are at the center of the electric power transformation from the power plant are changing to IEC 61850 based digital substations. Therefore, within substation, there is a growing demand for the IEC 61850 based Intelligent Electronic Devices (IEDs). The operation of multiple manufacturers of IEDs in a single digital substation network increases the need for IEC 61850 communications specification conformance diagnosis to ensure interoperability for efficient data exchange between IEDs. The IEC 61850-10 presents test items for diagnosing communication specification conformance. There are many test tools available in the market today to test the compliance of the IEC 61850 communications specifications to the IED. In this paper, we propose a model-based diagnostic method for IED communication conformance testing. The proposed model-based software therefore uses the “drag and drop” technique to select the various IEC 61850 communication services (objects) required to design the test case in a user friendly Graphical User Interface (GUI). This makes the service conformance testing more flexible for test engineers and system integrators especially in situations that require test case modifications. Also, the proposed software tool makes it easy to understand the various IEC 61850 services using the friendly GUI.展开更多
This paper discourses the typical ways to access system of the battery energy storage system. To realize the battery energy storage system based on IEC 61850, hierarchical information architecture for battery energy s...This paper discourses the typical ways to access system of the battery energy storage system. To realize the battery energy storage system based on IEC 61850, hierarchical information architecture for battery energy storage system is presented, the general design and implementation methods for device information model are elaborated, and the communication methods of the architecture are proposed. Example of battery energy storage system information model based on IEC 61850 tests that the battery energy storage system information architecture established is feasible.展开更多
基金National Natural Science Foundation of China(No.50777040)
文摘In order to meet the requirements of information exchange varieties and manners in wide area protection system, a communication service model based on IEC 61850 is proposed. This service model can realize communication consistency and cooperation between different types of devices. Furthermore, the communication reliability and time delay performance are guaranteed to meet the requirements of relay protection from the upper layer. Message structure of generic sub-station event (GSE) and its communication mechanism are discussed. General methods to communicate digital information by generic substation status event (GSSE) and communicate analog sampling information by sampling analog value (SAV) of GSE are proposed.
文摘Globally, traditional power systems are rapidly transforming towards the adoption of smart grid platforms. Substations which are at the center of the electric power transformation from the power plant are changing to IEC 61850 based digital substations. Therefore, within substation, there is a growing demand for the IEC 61850 based Intelligent Electronic Devices (IEDs). The operation of multiple manufacturers of IEDs in a single digital substation network increases the need for IEC 61850 communications specification conformance diagnosis to ensure interoperability for efficient data exchange between IEDs. The IEC 61850-10 presents test items for diagnosing communication specification conformance. There are many test tools available in the market today to test the compliance of the IEC 61850 communications specifications to the IED. In this paper, we propose a model-based diagnostic method for IED communication conformance testing. The proposed model-based software therefore uses the “drag and drop” technique to select the various IEC 61850 communication services (objects) required to design the test case in a user friendly Graphical User Interface (GUI). This makes the service conformance testing more flexible for test engineers and system integrators especially in situations that require test case modifications. Also, the proposed software tool makes it easy to understand the various IEC 61850 services using the friendly GUI.
文摘This paper discourses the typical ways to access system of the battery energy storage system. To realize the battery energy storage system based on IEC 61850, hierarchical information architecture for battery energy storage system is presented, the general design and implementation methods for device information model are elaborated, and the communication methods of the architecture are proposed. Example of battery energy storage system information model based on IEC 61850 tests that the battery energy storage system information architecture established is feasible.